NATIONAL INSTRUMENTS NI SMB-2145 Source Measure Unit User Guide
- June 17, 2024
- NATIONAL INSTRUMENTS
Table of Contents
- NATIONAL INSTRUMENTS NI SMB-2145 Source Measure Unit
- Conventions
- What You Need to Get Started
- Related Documentation
- Parts Locator
- Installing Cables
- Connecting Signals
- Cleaning the Accessory
- Specifications
- Compliance and Certifications
- Technical Support Resources
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
NATIONAL INSTRUMENTS NI SMB-2145 Source Measure Unit
Shielded Signal Accessories for NI 5751/5752 Adapter Modules
The NI SMB-2145/2146/2147/2148 (NI SMB-214x) devices are shielded signal accessories for NI FlexRIO™ digitizer adapter modules (NI 5751 and NI 5752). NI SMB-214x accessories provide easy connections to other devices for testing and debugging. The following table describes each of the accessories.
Table 1. NI 214x Signal Accessories
Accessory | Description |
---|---|
NI SMB-2145 | NI 5752 analog input accessory |
NI SMB-2146 | NI 5752 digital I/O accessory |
NI SMB-2147 | NI 5751 analog input accessory |
NI SMB-2148 | NI 5751 digital I/O accessory |
This guide explains how to set up and use NI SMB-214x signal accessories with NI 5751/5752 adapter modules.
Conventions
The following conventions are used in this manual:
-
This icon denotes a note, which alerts you to important information.
-
This icon denotes a caution, which advises you of precautions to take to avoid injury, data loss, or a system crash. When this symbol is marked on a product, refer to the Specifications section for information about precautions to take.
-
italic
Italic text denotes variables, emphasis, a cross-reference, or an introduction to a key concept. Italic text also denotes text that is a placeholder for a word or value that you must supply. -
monospace
Text in this font denotes text or characters that you should enter from the keyboard, sections of code, programming examples, and syntax examples. This font is also used for the proper names of disk drives, paths, directories, programs, subprograms, subroutines, device names, functions, operations, variables, filenames, and extensions.
What You Need to Get Started
To set up and use the NI SMB-214x, you need the following items:
- NI 5751R or NI 5752R, installed in a PXI/PXI Express or CompactPCI chassis
Note The NI 5751R and NI 5752R are comprised of an NI FlexRIO FPGA module and an NI FlexRIO adapter module (NI 5751 or NI 5752).
The appropriate cable assembly for your adapter module:
Table 2. NI SMB-214x Cables
Adapter Module/Signal | Cable Description | Part Number |
---|---|---|
NI 5751 Analog | SHC68-C68-D4 | 196275A-01 |
NI 5751 Digital | SHC68-C68-D4 | 196275A-01 |
NI 5752 Analog | SHC68-C68-D3 | 188143B-01 |
NI 5752 Digital | SHC68-C68-D4 | 196275A-01 |
At least one 50 Ω cable with SMB connectors
Related Documentation
You may find the following documents helpful as you use the NI SMB-214x.
- NI 5751R User Guide and Specifications
- NI 5752R User Guide and Specifications
- NI FlexRIO FPGA Module Installation Guide and Specifications
These printed documents provide the specifications for your adapter module and your FPGA module. These documents are also available at ni.com/manuals.
Parts Locator
Figures 1-4 show the connectors on each of the NI SMB-214x accessories.
Installing Cables
Caution Disconnect power from the adapter module, accessory, and any other connected hardware before connecting the cable to prevent personal injury or damage to the hardware. NI is not liable for damage resulting from improper connections.
Complete the following steps to install the cable and any 50 Ω SMB cables.
-
Install the NI 5751R or NI 5752R by following the installation procedure described in the NI FlexRIO FPGA Module Installation Guide and Specifications.
-
Remove power from the adapter module by powering down the PXI/PXI Express or CompactPCI chassis or by programmatically removing power from the adapter module. Power down any external hardware intended for connection to this system.
-
Attach either end of the cable assembly to the VHDCI connector on the front panel of the adapter module and secure the cable with the captive screws on the cable connector.
Note Do not use cables other than the cables listed in Table 2 with these accessories. -
Attach and secure the other end of the cable assembly to the VHDCI connector of the NI SMB-214x and secure them together with the captive screws on the cable connector.
Figures 5 and 6 show how to connect your NI SMB-214x accessory to your NI FlexRIO system.
- 1 PXI Chassis with NI 5752R
- NI SMB-2145
- NI SMB-2146
- SHC68-C68-D4 Cable Assembly
- SHC68-C68-D3 Cable Assembly
Figure 5. Connecting the NI 5752R to the NI SMB-2145 and NI SMB-2146
-
PXI Chassis with NI 5751R
-
NI SMB-2147
-
NI SMB-2148
-
SHC68-C68-D4 Cable Assemblies
Figure 6. Connecting the NI 5751R to the NI SMB-2147 and NI SMB-2148 -
Make signal connections by connecting SMB cables to NI SMB-214x signal terminals. Refer to the Connecting Signals section for more information.
Note To ensure a solid ground connection, tighten the SMB connectors by gently snapping them into place. -
Apply power to the adapter module by powering on the PXI/PXIe or Compact PCI chassis or by programmatically applying power to the adapter module.
-
Power on any external hardware intended for use with this system.
Connecting Signals
- The NI SMB-214x provides signal connectivity to the NI 5751/5752 adapter module. You can connect to these signals from the labeled SMB connectors on the NI SMB-214x.
- Caution Connections that exceed any of the maximum ratings for the NI SMB-214x or the NI 5751/5752 adapter module can damage the device and the computer. Maximum input ratings are provided in the specifications document that shipped with the adapter module. NI is not liable for any damages resulting from such signal connections.
- Figures 7 through 10 show the pinouts of the VHDCI connectors of NI SMB-214x accessories. The analog inputs, digital inputs, and digital outputs are connected to corresponding pins on the NI SMB-214x. Refer to Table 3 for the pin descriptions.
Table 3. VHDCI Connector Pinout Descriptions
Pin | Signal Description |
---|---|
AI <0..31> | Analog input channels 0 through 31 |
DI <0..15> | Digital input channels 0 through 15 |
DO <0..15> | Digital output channels 0 through 15 |
GND | Ground reference for signals |
RSVD | Reserved for system use. Do not connect signals to these channels. |
NI SMB-2145
NI SMB-2146
NI SMB-2147
NI SMB-2148
Note For additional shielding, you can connect the shield ground connector on the NI SMB-214x to earth/hard ground. This terminal is connected to the shielded enclosure ground. The shield ground lug is shown in Figures 1 through 4.
Cleaning the Accessory
Disconnect all cables to the NI SMB-214x before cleaning. To remove light dust, use a soft, nonmetallic brush. To remove other contaminants, use alcohol wipes. The unit must be completely dry and free from contaminants before returning to service.
Specifications
These specifications are characteristic at 25 °C unless otherwise noted.
NI SMB-2145
Analog Input
- Analog input channels………………………. 16, single-ended
- Typical propagation delay through NI SMB-2145 ……………………… 1.2 ns
- Typical channel-to-channel skew……….. ±35 ps
- Typical trace characteristic impedance …………………… 50
- Maximum voltage rating…………………… 5.5 V or the maximum input voltage of the NI 5752 analog inputs, whichever is less
Physical
- Dimensions……………………………………… 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.)
- Weight ……………………………………………. 1,380 g (48.7 oz.)
- I/O connectors ………………………………….One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector
NI SMB-2146
Digital I/O
- Digital output channels ………………………16, single-ended
- Digital input channels ………………………..2, single-ended
- Typical propagation delay through NI SMB-2146……………………….1.2 ns
- Typical channel-to-channel skew………..±35 ps
- Typical trace characteristic impedance…………………….50
- Maximum voltage rating ……………………5.5 V or the maximum input voltage of the NI 5752 digital inputs, whichever is less
Physical
- Dimensions ………………………………………30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.)
- Weight …………………………………………….1,380 g (48.7 oz.)
- I/O connectors…………………………………..One 68-pin VHDCI connector, 18 SMB jack connectors, one banana-style connector
NI SMB-2147
Analog Input
- Analog input channels ……………………….16, single-ended
- Typical propagation delay through NI SMB-2147……………………….1.2 ns
- Typical channel-to-channel skew………..±35 ps
- Typical trace characteristic impedance…………………….50
- Maximum voltage rating ……………………5.5 V or the maximum input voltage of the NI 5751 analog inputs, whichever is less
Physical
- Dimensions……………………………………… 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.)
- Weight ……………………………………………. 1,380 g (48.7 oz.)
- I/O connectors ………………………………….One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector
NI SMB-2148
Digital I/O
- Digital input channels ………………………. 8, single-ended
- Digital output channels …………………….. 8, single-ended
- Typical propagation delay through NI SMB-2148 ……………………… 1.2 ns
- Typical channel-to-channel skew……….. ±35 ps
- Typical trace characteristic impedance …………………… 50
- Maximum voltage rating…………………… 5.5 V or the maximum input voltage of the NI 5751 digital inputs, whichever is less
Physical
- Dimensions……………………………………… 30.5 cm × 4.5 cm × 26.5 cm (12.0 in. × 1.77 in. × 10.43 in.)
- Weight ……………………………………………. 1,380 g (48.7 oz.)
- I/O connectors ………………………………….One 68-pin VHDCI connector, 16 SMB jack connectors, one banana-style connector
Compliance and Certifications
Environmental Management
National Instruments is committed to designing and manufacturing products
in an environmentally responsible manner. NI recognizes that eliminating
certain hazardous substances from our products is beneficial to the
environment and NI customers. For additional environmental information, refer
to the NI and the Environment Web page at
ni.com/environment. This page contains the
environmental regulations and directives with which NI complies, as well as
other environmental information not included in this document.
Waste Electrical and Electronic Equipment (WEEE)
EU Customers At the end of the product life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers, National Instruments WEEE initiatives, and compliance with WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit ni.com/environment/weee.
RoHS
National Instruments RoHS
ni.com/environment/rohs_china
(For information about China RoHS compliance, go to
ni.com/environment/rohs_china.)
Technical Support Resources
The National Instruments Web site is your complete resource for technical
support. At ni.com/support you have access to
everything from troubleshooting and application development self-help
resources to email and phone assistance from NI Application Engineers.
National Instruments corporate headquarters is located at 11500 North Mopac
Expressway, Austin, Texas, 78759-3504.
National Instruments also has offices located around the world to help address
your support needs. For telephone support in the United States, create your
service request at ni.com/support and follow the
calling instructions or dial 512 795 8248. For telephone support outside the
United States, contact your local branch office:
- Australia 1800 300 800, Austria 43 662 457990-0,
- Belgium 32 (0) 2 757 0020, Brazil 55 11 3262 3599,
- Canada 800 433 3488, China 86 21 5050 9800,
- Czech Republic 420 224 235 774, Denmark 45 45 76 26 00,
- Finland 358 (0) 9 725 72511, France 01 57 66 24 24,
- Germany 49 89 7413130, India 91 80 41190000,
- Italy 39 02 41309277, Japan 0120-527196, Korea 82 02 3451 3400,
- Lebanon 961 (0) 1 33 28 28, Malaysia 1800 887710,
- Mexico 01 800 010 0793, Netherlands 31 (0) 348 433 466,
- New Zealand 0800 553 322, Norway 47 (0) 66 90 76 60,
- Poland 48 22 328 90 10, Portugal 351 210 311 210,
- Russia 7 495 783 6851, Singapore 1800 226 5886,
- Slovenia 386 3 425 42 00, South Africa 27 0 11 805 8197,
- Spain 34 91 640 0085, Sweden 46 (0) 8 587 895 00,
- Switzerland 41 56 2005151, Taiwan 886 02 2377 2222,
- Thailand 662 278 6777, Turkey 90 212 279 3031,
- United Kingdom 44 (0) 1635 523545
LabVIEW, National Instruments, NI, ni.com, the National
Instruments corporate logo, and the Eagle logo are trademarks of National
Instruments Corporation. Refer to the Trademark Information at
ni.com/trademarks for other National Instruments
trademarks. Other product and company names mentioned herein are trademarks or
trade names of their respective companies. For patents covering National
Instruments products/technology, refer to the appropriate location: Help»
Patents in your software, the patents.txt file on your media, or the National
Instruments Patent Notice at ni.com/patents.
© 2010 National Instruments Corporation. All rights reserved.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>