villastar YC-007 Pool Heater Above Ground Pool Instruction Manual
- June 17, 2024
- villastar
Table of Contents
YC-007 Pool Heater Above Ground Pool
Product Information
Specifications
- Model Number: YC-007
- Product Type: Swimming Pool Air Source Heat Pump
Packing List
No. | Name | Qty. | Remark |
---|---|---|---|
1 | Installation & Operation Manual | 1 | |
2 | Wire-controller | 1 | Wire controller box and sponge pad |
3 | 1 | (Will install on the heat pump shell) | |
4 | Wire-controller Cable (about 10m) | 1 | |
5 | Drain-pipe (2 m) | 1 | |
6 | Drain-pipe connector | 1 | |
7 | Rubber shock absorber | 4 | |
8 | Heat Pump Unit | 1 | The pipe connector has been installed on the machine |
Accessories Description
No. | Name | Qty. | Use |
---|---|---|---|
1 | Installation & Operation Manual | 1 PC | Guide users to install the system |
2 | Wire controller | 1 PC | Used for the man-machine operation interface |
3 | Wire controller connecting cable | 1 PC | Connect wired controller to heat |
pump unit
4| Drain-pipe| 1 PC| Used for draining the condensate water
5| Drain-pipe connector| 1 PC| Connect the drain pipe to the heat pump unit
6| Rubber shock absorber| 4 PCS| Reduce vibration and reduce noise
7| Heat pump unit| 1 SET| For heating water
Attention for Safety
The installation shall be done by professional persons to
prevent leaking, electric shock, or fire disaster. Confirm the
ground connection. If the ground connection is not correctly done,
it may cause electric shock.
Heat Pump Unit Working Principle
Air Source Heat Pump Working Principle
The heat pump works by absorbing heat energy from the ambient
environment and transferring it to the water. It uses a 4-way
valve, compressor, filter, gas-liquid separator, expansion valve,
condenser, and evaporator fan unit to achieve this process.
The formula for heat energy gained (Qc) is:
Qc = Qa (Compressor consumption) + Qb (Heat energy absorbed from
ambient environment)
Heat Pump Performance Curve for Variable Working Condition
The heat pump’s coefficient of performance (COP) is variable
depending on the working condition.
Installation of the Unit
Installation Space
Before installation, ensure the following indicated space for
operation and maintenance:
FAQ
-
1. Can I install auxiliary electric heaters in the system?
No, we do not recommend installing auxiliary electric heaters in
the system. If you must install them, it should be done by
specialized persons. Our company is not responsible for any
problems caused by the auxiliary electric heater.
-
1. Can the unit be used in the winter?
No, the unit is not suitable for use in the winter. The water
reserved in the pipe network system must be drained.
-
1. Is lightning protection necessary for installation?
If the unit would be installed where it is vulnerable to
lightning stroke, lightning protection measures must be carried
out.
Installation & Operation Manual
Swimming Pool Air Source Heat Pump
Model Number : YC-007
Thank you very much for purchasing our product,please keep and read this
manual carefully before you install heat pump.
Packing List
No.
Name
Qty.
1
Installation & Operation Manual
1
Remark
2
Wire-controller
1
Wire controller box and sponge pad
3
1
(Will install on the heat pump shell)
4 Wire-controller Cable (about 10m)
1
5
Drain-pipe (2 m)
1
6
Drain-pipe connector
1
7
Rubber shock absorber
4
Heat Pump Unit
8 (The pipe connector has been
1
installed on the machine)
Please keep installation manual properly, and read it carefully before using.
The unit must be installed by professional personnel, and install it based on
this manual as possible.
Special reminding: if the unit would be installed where is vulnerable to
lightning stroke, lightning protection measurements must be carried out.
Special reminding: The unit is not suitable for using in the winter, the water
reserved in the pipe network system must be drained.
Content Accessories description……………………………………………………………….4 Attention for
safety……………………………………………………………………….5 Heat pump unit working
principle………………………………………………….6 Installation of the
unit……………………………………………………………………8 Installation of the
pipeline……………………………………………………………11 Installation of optional
accessories………………………………………………13 Installation and operation of electric
devices………………………………..14 Instruction of operation ………………………………………………………………18
Adjusting and Initial operation……………………………………………………..31 Operation and
maintenance…………………………………………………………32 Fault analysis and elimination
method………………………………………….34 Technical parameter……………………………………………………………………..35
After-sale service…………………………………………………………………………35
1. Accessories description
Each unit produced by our factory is with the following accessories:
No.
Name
Qty.
Use
1 Installation & Operation Manual 1 PC Guide users to install the system
2 Wire controller
1 PC Used for the man-machine operation interface
3 Wire controller connecting cable 1 PC Connect wired controller to heat pump unit
4 Drain-pipe
1 PC Used for draining the condensate water
5 Drain-pipe connector
1 PC Connect the drain pipe to the heat pump unit
6 Rubber shock absorber
4 PCS Reduce vibration and reduce noise
7 Heat pump unit
1 SET For heating water
For function you need to purchase at least the following parts for each unit:
No.
Name
1 Water pump
2 Filter system
3 Water pipes system
Qty.
use
1 Cycle the heated water
1 Protect the heat pump from pool water
1 Connect the equipment and make circulation
NOTE
The types and quantity of the water pipes, valves, filter equipment,
sterilizing equipment which used for the swimming pool heating/circulation
pipe system, depend on the project design. We do not suggest to install
auxiliary electric heaters in the system. If must install auxiliary electric
heaters, must install the electric heaters by the specialized persons, and our
company has no responsibility for all the problem cause by the auxiliary
electric heater.
2. Attention for safety
Range of application: 1.Power supply: 220-240V/~60Hz. 2.Environment
temperature: 19.4°F109.4°F 3.Working water temperature: Min. inlet water
temperature 46°F,Max. outlet Water Temperature 104°F. If the system is always
used beyond the available water range, please contact with manufacturer.
The installation shall be done by the professional persons, to prevent
leaking, electric shock, or fire disaster. Confirm the ground connection, if
the ground connection is not correctly done, it may cause electric shock.
When install the heat pump in a small room, must keep well ventilated. Don’t
put finger or sticker into the air inlet or air outlet. Because the internal
rotor high-speed operation may cause injury. When an exception happens
(burning smell), turn off the manual power switch immediately, stop operating,
and contact with after-sale service department. If continue the abnormal
operation, it may cause electric shock or fire disaster. When the unit needs
to be removed or re-installed, please entrust after-sale service department
and specialized personnel to do it. If the installation is not well done, it
may cause unit operation failure, electric shock, fire, hurt, leaking, etc.
Must not be unauthorized reformed, otherwise it may cause electric shock or
fire.
When needs to be repaired, please entrust after-sale service department or a
specialized personnel to implement. If improper repaired, it may cause unit
operation failure, electric shock, fire, hurt, leaking, etc. Can not install
the unit in combustible gas easy-leaking places, once the combustible gas
leaks around the unit, it may cause a fire. Confirm if the installation base
is strong enough, if it is not strong and has been used for a long time, it
may cause falling and injuries. Confirm if leakage protection switch is
installed, if don’t install a leakage protection switch, may cause electric
shock or fire. When cleaning the unit, the operation should be stopped, and
power switch should be turned off.
3. Heat pump unit working principle
3.1 Heat pump working process First, the low pressure and superheated gas in
the evaporator is inhaled into the compressor then becomes the high
temperature and high pressure overheated vapour. Second, the overheated vapour
is exhausted into the condenser and exchange the heat with the water, then the
refrigerant is condensed and becomes the saturated or over cooling high
pressure and high temperature refrigerant liquid. The water is heated up by
heat pump when absorbing the heat energy which released by the refrigerant.
Third, the refrigerant liquid releases the pressure by passing the expansion
valve, then becomes the low temperature and low pressure liquid. Fourth, the
refrigerant liquid flows into the evaporator and absorb the energy from the
air, then is vaporized and became the low pressure and overheated vapour. The
refrigerant working repeatedly as described above, then the water which flows
through the condenser is heated up constantly, the temperature rise and can
get the hot water.
3.2 Air source heat pump working principle
4 way valve
Ev ap or a to r Fa n un i t
Compressor Filter
Gas-liquid separator
Filter
Expansion valve
Water inlet Condenser
Water Outlet
Figure 1
Qc (Heat energy get) =Qa (Compressor consumption) +Qb (Heat energy absorbed
from ambient environment)
3.3 Heat pump performance curve for variable working condition
COP
Figure 2 Environment temperature (°F ) Attention pipeline anti-freezing in case the environmental temperature drops to 32°F.
4. Installation of the unit
4.1 Installation attention Avoid installations in such locations with mineral
oil. Avoid installation in locations where air contains salt or other
corrosive gas. Avoid installation in locations with serious power supply
voltage fluctuation. Avoid installation in an unstable place, such as car or
cabin Avoid installation near flammable items. Avoid installation in locations
with strong electromagnetic wave. Avoid installation in locations with special
harsh environmental conditions. 4.2 Installation check Check the model,
number, name etc, avoid incorrect installation. Make sure enough space for
installation and maintenance. Make sure barrier-free for air inlet and outlet,
also dry ventilated place. Make sure the bearing surface can meet the
requirement and avoid shocks. The power supply and its capacity, wire diameter
choice should be in accordance with the electrical installation requirements.
Electrical installation must comply with the relevant technical standards of
electrical equipment, and electrical insulation work must be done. The unit
must be power on for at least eight hours before running and debugging.
4.3 Installation space Keep the following indicated space for operation and
maintenance first before installation
Figure 3 Horizontal type installation spaceunits: mm
4.4 Heat pump unit size
Figure 4 Horizontal type heat pump size
Size(mm) Model No.
YC-007
A
B
C
1011
614
357
4.5 Reserve the installation base for the heat pump
Please refer to Figure 5.
A n ch o r b o lt
Drainage tray
Heat Pump Heat Pump
D
E
F
645
183
420
Anchor bolt Screw nut/washer Shock absorb
Drainage tray Installation base
C o n cre te
Figure 5 Reserved installation base
4.6 Hoisting attention Please use four or more soft lifting belts to move the
sets Figure 6. Please use protective plate on the surface of the sets when
moving, to avoid scratch and deformation. Recheck whether the foundation is
correct before hoisting the unit. The heat pump will produce condensation
water,please consider the drainage channel when make the installation base.
Please put shock absorb on base surface.
Figure 6 Hoisting diagram
5. Installation of the pipeline
5.1 Attention Prevent air, dust and other sundries from going into the water
pipes.
Fix the whole system before install the water pipes.
Water inlet and outlet pipes shall be protected by the insulation layer.
Stable water velocity shall be ensured, so that excessive throttling can be
avoid.
When moving, water inlet and outlet pipe shall not be used for hanging, only
the holes on the beam of the base can be used, please refer to Figure 9
When connect the water inlet and outlet pipes, two pipe wrenches shall be used
to control the two parts of the pipes, and ensure the water inlet and outlet
pipes not turning around, please refer to the Figure 7
5.2 Instruction 5.2.1 Marginal data
Figure 7
5.2.2 Pipeline installation diagram
Water temp. sensor wire
Feeding water
Controller
Swimming Pool
Drainage
Heat Pump
Pump signal wire
Pump
Drainage
Figure 8 DiagramSingle unit for reference
The one-way valve is suggested for each unit, to prevent the water back flow.
The system can be combined with multiple units, but should be controlled by each unit independently.
Regarding the installation of backup pump, maintenance valve and temperature measure point, please consider it yourself.
All pipes and valves of the unit need the heat preservation.
5.2.3 Selection of the water pipes
Model No.
Inlet
Outlet
YC-007
DN50
DN50
The swimming pool heat pump adopt the titanium heat ex-changer, can connect the swimming pool directly, but must install a water filtration equipment before water go into heat pump, the filter meshes is about 40 meshes.
Main pipe diameter selection of the parallel connected multiple units (example)
Inlet/outlet pipe Inlet/outlet pipe Inlet/outlet pipe Inlet/outlet pipe Inlet/outlet pipe
YC-007 YC-007 YC-007 YC-007 YC-007
One unit Two units connection Three units connection Four units connection Five units connection
DN50 DN65 DN80 DN80 DN100
The pipe press and flow rate should be calculated before the diameter selection, the range of pressure drop is 0.30.5 kgf/cm2(35m the range of head pipe flow rate is 1 .22. 5 m/s.
The hydraulic calculation should be made after the selection of pipe diameter, if the resistance is more than pump head, then need to choose a more power pump, or choose a bigger pipe.
5.2.4 The demanded quality of water
The bad quality water will produce more scale and sand, so this kind of water should be filtered and demineralized.
The water quality should be analyzed before system running, to measure the PH value, conductivity, Chloride ion concentration and sulphate ion concentration.
The acceptable water quality standard is showed as below table.
PH value Total hardness Conductivity
Sulphate ion
78.5
< 50ppm
<200V/cm(77)
None
Sulfate ion
Silicon
Iron content
Sodium
< 50ppm
< 50ppm
< 0.3ppm
No requirement
Chlorine ion < 50ppm Ca < 50ppm
Ammonia ion None
Suggest the filter meshes is about 40 meshes.
Must install the sand filter, hair collector etc. Swimming pool special impurity filter equipment.
6. Installation of optional accessories
6.1 Selection of the water pump
The circulation pump is needed for the system, the power port is prepared for
the pump, (one phase)
NOTE
For the single phase pump, please check the circuitry diagram.
The head of circulation pump = height difference between water level and main
unit + total pipelines resistance (determined by the hydraulic calculation) +
pressure loss of main unit (see the nameplate on heat pump ).
NOTE
when multi paralleled, the water pump head is subject to the worst working
condition loop.
7. Installation of electric devices
7.1 Electrical wiring The unit should use a dedicated power supply, power
supply voltage with rated voltage. Unit power supply circuit must be ground,
power supply wire and external grounding reliable connection, and the external
grounding is effective. Wiring must be constructed by the professional
installation technicians in accordance with the circuit diagram. Power line
and signal line layout should be neat, reasonable, can not interfere with each
other, but not with the connecting pipe and the valve body contact. If the
unit is not matching the power line, please supply specifications refer to
provisions, wires connecting is not allowed. After all wiring construction is
completed, please check it before switch on the power supply carefully.
Screw out the bolt and open this front panel, will find the main control board
and terminal block.
Figure 11
PCB
Fan motor Capacitor
Compressor Capacitor
LN12
Terminal
4# Wire press buckle
G: (y ou)\YQ01-2.bmp
Figure 12 Electrical Box
7.2 Electrical Wiring Specification
Model
YC-007 Terminal
Electrical Wiring Specification
22.5 mm²+11mm² The terminal can connect the wire max. is 4 mm²
Figure 13
7.3 Circulation pump installation The heat pump only provide the signal for
circulation pump, must use an a.c. Contactor to connect the circulation pump.
NOTE: Here only for signal control never drive it directly
Figure 15
Figure 16
7.4 Electric wiring diagram
Figure 17
8. Instruction of operation
8.1 Control system specifications 8.1.1 Operating condition Voltage:
220V±10%,60Hz Ambient temperature:19.4109.4
8.1.2 Main function Three operation mode: heating,cooling and constant
temperature mode. Display the pool temperature and setting temperature, and
also can query the coil temperature, ambient temperature and exhaust
temperature and so on. Power cut memory function. When power cut, the clock
will still work. Timing on/off. Automatic defrosting. Forced to defrost. Large
LCD display. Has perfect protection function. The error code display and query
Key-Lock Function Anti-freezing function When there is no wire controller or
wire controller is broken, the system can recognize it, and control the heat
pump to run automatically.
8.2 Wire controller and operation
8.2.1 Controller Instruction
symbol
status
Constantly bright
heat pump is on
meaning
Extinguished
Heat pump is off
Constantly bright at cooling mode
Constantly bright at heating mode
Constantly bright
Constantly bright Extinguished
Constantly bright Extinguished
Constantly bright Flashing Flashing
Constantly bright
need repair
at AUTO mode Currently in the manual set temperature state this unit is a
water connection heat pump this unit is a refrigerant connection heat pump
heat pump is on and at defrosting Heat pump is on and at defrost delay heat
pump is off and at refrigerant recovery status
electric heater is on for quick heating
Flashing
Constantly bright Constantly bright
electric heater is on for disinfection
current water temperature in the tank set water temperature in the tank
Constantly bright current outlet water temperature
Constantly bright current inlet water temperature
display
Display actual water temperature, set water temperature and fault code
Constantly bright Currently showing Celsius temperature
display
Show real time
display
Timer function is on
display
Currently in the on-time working hours
Flashing
set start time for working time
display
Currently at boot time, non-working time
Flashing
end time of current set working time
1
Constantly bright / Timing working period 1,always on when set, at other
Extinguished
conditions are off.
2
Constantly bright / Timing working period 2,always on when set, at other
Extinguished
conditions are off.
3
Constantly bright / Timing working period 3,always on when set, at other
Extinguished
conditions are off.
Constantly bright start timing water return function
Flashing
start manual water return function
Extinguished
turn off water return (timing/manual) function
display
Currently the return water is in regular timing working period
Flashing
Current set start time of backwater working time
display
Currently the return water is in the non-working hours
Flashing
Currently set end time of water return period
1
Constantly bright / Timing zero cold water period 1, always on when setting, at
Extinguished
other conditions are off.
2
Constantly bright / Timing zero cold water period 2, always on when setting, at
Extinguished
other conditions are off.
Constantly bright The button is locked
Constantly bright The controller is connected to the router
8.2.2 Instruction of the buttons button
1
Power/exit
button
2
up
instruction
1. Press and hold for 1 second to turn on/off. 2. In the query state, click
this button to return to the main interface. 1. Press at main interface to set
the temperature. 2. Press and hold for 3 seconds in the power on/off state to
enter the query state. 3. In the query status, press and check status 4. At
parameter set status, press to modify parameters
3
down
4
Mode
button
5
time
6
set
Button
combinati
7
on
1. Press at main interface to set the temperature.
2. Press and hold for 3 seconds in the power on/off
state to enter the query state.
3. In the query status, click to status query
4. Under parameter setting state, click parameter to
modify
1. In the main interface, press and hold for 3 seconds to start (and enter
zero cold water time setting) / turn off the timing zero cold water function;
(when parameter 64=1) 2. In the main interface, short press for more than 1
second to cancel the zero cold water function in this period; (when parameter
64=1) 3. In the main interface, short press within 1 second to
activate/deactivate the manual zero cold water function. (when parameter 64=1)
4. Under the main interface, click to switch between heating and cooling
operation status (when parameter 64=0)
1. In the main interface, press to enter the clock setting, and press to
switch time “hour” and “minute”. 2. In the main interface, press and hold for
3 seconds to start (and enter the timing time setting) / turn off the timing
mode.
1. Under the main interface, press to switch between automatic/manual
temperature control mode. “AUTO” is displayed in the automatic mode and is not
displayed when manual 2. In the main interface, press and hold for 3 seconds
to enter the parameter interface.
”
“+” at main interface when ON, press and hold for 3
seconds to turn on/off quick heating ”
at main interface when ON, press and hold for 3
”
“+” seconds to turn on/off defrosting
” ” “+” Within 5 minutes after power-on, at the main interface of shutdown, press and hold for 10 seconds to
”
enter/exit refrigerant charging or recycling mode
” “+” Under the main interface, press and hold for 10
“+”
” seconds to turn on/off the “sterilization” function
manually (Parameter 66=1 is valid)
” “+” “+” Within 5 minutes after power-on, press and hold for 5
seconds to restore the factory parameter settings.
“+”
”
8.2.3 Operation Instruction 1)Turn ON/OFF the heat pump
When the controller is in the normal display state, press ” ” button for more
than 1 second to
switch the controller to the power on or off state. When heat pump is ON,” ”
lights up and is
normally controlled. When heat pump is off,” “does not light up and the
controller stops controlling
output. The controller can display and operate normally in the power on state
and off state. When the controller is powered on for the first time, it is in
the off state. Then from the 2nd time, the state will be same as last time
before power off.
2)Set the temperature control mode: When the controller is in normal display
state, press the “M” key to switch between manual temperature control mode and
automatic temperature control mode; The “AUTO” symbol lights up in the
automatic temperature control mode, And the “AUTO” symbol does not light up in
the manual temperature control mode; In the manual mode, the heating/cooling
water temperature is controlled according to the manual temperature setting
value; In the automatic mode, the hot water temperature is automatically
adjusted according to the ambient temperature for control;
3)Set the water temperature: In manual mode, press”” or “” key to enter the
water temperature setting state. Then starts to display the setting symbol and
display the corresponding water temperature set according to the current
cooling or heating mode. When the water temperature is set, press the “” or “”
button to increase or decrease the water temperature setting value; Press and
hold the “” or “” button for more than 1 second to quickly increase or
decrease the water temperature setting. Press and release the ” ” button
immediately or no button operation in 5 seconds, controller will exits the
modification and return to the normal display state. When the parameter value
is modified, it will flash for 2 seconds and then return to the normal display
state. In the automatic mode, press the “” or “” key to enter the automatic
temperature adjustable parameter deviation setting state. Then start to
display the setting symbol and display the corresponding deviation setting
value. Press “” or “” to increase or decrease the deviation setting value;
press “” or “” for more than 1 second to quickly adjust or decrease the
deviation setting value; press and Immediately release the ” ” button or no
button operation in 5 seconds to exit the modification and return to the
normal display state. When the parameter value is modified, it flashes for 2
seconds and then returns to the normal display state.
4)Real time clock settings: In the main interface, click the ”
” button to enter the real-time clock setting interface; In the
real-time clock interface, press the ” ” button, the hour part of the number
flashes, press “” or “”, you can Set the hour of the clock; when the hour part
is set, press the “Time” button again, the number of minutes will flash, press
“” or “” to set the minute of the real time clock; After the
minute part is set, press the ” ” button again to confirm the real-time clock
setting and return to the main interface; In the real-time clock setting
interface, if there is no button operation for 5 seconds, the current real-
time clock setting value is confirmed, and the main interface is returned; In
the real-time clock setting interface, press the ” ” button to confirm the
current real-time clock setting value and return to the main interface.
5)Timing work settings:
Press and hold the ”
” button for 3 seconds in the main interface to enable or disable the timed
working mode. When the timed working mode is enabled, enter the timed period setting. Press and
release ” ” to switch the hour and minute of the start time and end time of
the three time slots in
sequence., The value is flashing when switching to the corresponding value of
the certain time slot. At the same time, “ON” or “OFF” symbol flashes, Press
“” or “” to increase or decrease the corresponding value. After setting the
timed period, press and immediately releasing the “switch” button or no button
operation in 15 seconds, the changes can be saved and returned to the normal
display state. When the timing control mode is enabled, the corresponding
symbols are displayed in the working period (ON) and the non-working period
(OFF) respectively. In the power-on state, heating/cooling is performed only
during the set working period, and the rest of the time is not
heating/cooling. When the start time and end time of a certain working period
are the same, it is regarded as canceling the timing period. When all timed
periods are cancelled, it is considered to be in working hours throughout the
day. If the start time of a certain working period is greater than the end
time, the end time is considered to be the next day. The three time periods
default to 05:00~07:00, 16:00~18:00, 20:00~00:00.
6)Set the cooling/heating mode:
With the controller in normal display, press ”
” to switch between cooling or heating mode.
When switching to the cooling or heating mode, the cooling or heating symbol flashes quickly for 3
seconds and then returns to the normal display state. When switching to the cooling mode, the
temperature judgment automatically selects “manual mode”, and the water temperature can be set at
this time. When the cooling/heating mode is switched, the compressor is allowed to start running
after at least 3 minutes of stopping.
-
Forced speed heating: When following conditions are met at the same time: the controller is in the normal display state and heat pump is in the power-on state. Heat pump needs to be in the working period after the timing control is enabled. The current heating mode is met and the temperature condition for continuing heating is satisfied, No other alarms that do not allow “speed heating” occur. Press”M” + “” button at the same time for more than 5 seconds, the “speed hot” function can be activated or deactivated. When the “speed heat” is running, the symbol lights up. If the heat pump is in cooling mode, “speed heat”is not allowed.
-
Forced defrosting: When following conditions are met at the same time: the controller is in the normal display state and heat pump is in the power-on state. Heat pump needs to be in the working period after the timing control is enabled. The current heating mode is set and the set defrosting time is not zero and the temperature condition of the defrosting is continued, No other alarms that do not allow “frost” occur. Press”M” + “” button at the same time for more than 5 seconds to activate or deactivate the “Defrost” function. The symbol is illuminated when the “Defrost” is running. If heat pump is in cooling mode, “defrosting” operation is not allowed.
9)Forced sterilization: If the controller is in the normal display state and
it is currently in the heating mode, press the “M”+””+”” button at the same
time for more than 5 seconds to activate or deactivate the
“sterilization” function. The flashes at this manual “sterilization”
operation. When heat pump is in cooling mode, “sterilization” operation is not
allowed.
- Return time setting: (Fluorine cycle unit is valid; parameter 64=1)
Press and hold the ”
” button for 3 seconds in the main interface to enable or cancel the timed
water return mode. When the timed water return mode is enabled, the timed return time setting is
entered. Press”
” to switch the start time of the two time slots in turn, the hour part, the minute
part, the hour part of the end time. The corresponding parts are flashed when the corresponding value is switched. The corresponding time period is displayed and the”ON” or”OFF” symbol is flashing. Press “” or “” to up or down and flashing to display the corresponding value. After
setting the timed period, press and immediately release the ” ” button or no
button operation in 15
seconds, the changes can be saved and returned to the normal display state.
When the timing control mode is enabled, the corresponding symbols are
displayed separately during the working period and the non-working period. In
the power-on state, the water is automatically returned only during the set
working period, and the remaining time is not returned. When the start time
and end time of a certain working period are the same, it is regarded as
canceling the timing period. When all timed periods are cancelled, it is
considered to be in an
untimed return time period throughout the day. If the start time of a certain working period is greater than the end time, the end time is considered to be the next day. The factory default return water time is as follows: A, time period 1 opening time: 6:30 B, time period 1 closing time: 7:30 C, time period 2 opening time: 18:30 D, time 2 closed time: 22:30
11)Query running status: When the main interface of the power on or off is displayed, press and hold the “” or “” button for more than 3 seconds to enter the running status query interface; press and immediately release the
“” or “” button to check each operating condition; press and immediately release the ”
”
button or automatically return to the normal display state without any button operation in 30 seconds.
After entering the view mode, the last viewed data code (the default is “00” after power-on) and its corresponding value are displayed. After each press and immediately release the “” button, the following table can be displayed in order:
name Fluorine cycle/water cycle heat pump High pressure switch Low pressure switch Water flow switch EEV value Evaporator coil sensor ambient temperature sensor absorption temperature sensor exhaust temperature sensor inlet water temperature(tank water temperature) outlet water temperature(return water temperature) compressor 4-way valve high-speed fan low-speed fan circulation water pump electric heater
code
00
01 02 03 04 05 06
07
08
09
10
11 12 13 14 15 16
remark
0water cycle1fluorine cycle
0disconnect1close 0disconnect1close 0disconnect1close
Measured value Measured value Measured value Measured value
Measured value Display value = measured value +
compensation value
Display value = measured value + compensation value
0stop1running 0stop1running 0stop1running 0stop1running 0stop1running
0stop1running
12)Key lock:
When the controller is in the normal display state, the button is locked when
there is no button operation for more than 60 seconds. Press any button at
this time to unlock.
8.2.4 Control Output 1) Water temperature control Normal water temperature
control can be performed when the controller is turned on. Heating mode: When
the water tank (inlet water) temperature set temperature return difference,
heating begins; When the water tank (inlet water) temperature the set
temperature, the heating is stopped; Cooling mode: When the water tank (inlet
water) temperature set temperature + return difference, the cooling starts;
When the water tank (inlet water) temperature the set temperature, the cooling
stops.
2) Circulating pump control (water circulation heat pump): When defrosting,
water pump is forced to run. When cooling or heating, it is turned on 10
seconds before the compressor and stops 30 seconds after the compressor.
Antifreeze mode: When the controller is powered on, whether heat pump is off
or on, when the ambient temperature is too low, water pump will enter
antifreeze mode to prevent the circulation line or the water tank from
freezing. The specific conditions for enabling and disabling the environment
for low temperature antifreeze are as follows: a. When the ambient temperature
is 35 , and the duration of the circulating water pump is off for more than 30
minutes, the circulating water pump is forcibly started for 60 seconds; b.
Exit the antifreeze mode when the ambient temperature rises to 39 . c. When
the ambient temperature sensor is faulty, it is mandatory to start the
circulating water pump periodically, and run for 60 seconds every 30 minutes.
8.2.5 The Alarm 1) Low pressure fault: After the compressor running for 5
minutes, if the low pressure switch is detected to be in the off state for 10
consecutive seconds, the compressor immediately stops running. At this time,
the controller displays the low pressure fault alarm code “04E”. If the low
pressure switch is restored, error code does not occur. If no other protection
or locking occurs, the compressor is restarted after 3 minutes. If low
pressure fault protection appears 3 times within 1 hour, the controller will
lock the protection. And the compressor will lock in the shutdown protection
state. At this time, only the shutdown and restarting can unlock the
compressor. The low pressure switch is not detected during the defrosting.
2) High pressure failure: After the compressor is started, if the high
pressure switch is detected to be in the off state for 10
seconds, the compressor immediately stops running. At this time, the
controller displays the high pressure fault alarm code “03E”. If the high
pressure switch is restored, error code will not occur. And if no other
protection or locking occurs, the compressor is restarted after 3 minutes. If
high pressure fault protection appears 3 times within 1 hour, the controller
will lock the protection, and the compressor will be locked in the shutdown
protection state. At this time, only the shutdown and restarting can unlock
the compressor. 3) High exhaust temperature failure: After the compressor
starts running for 1 minute, when the exhaust gas temperature is detected to
be higher than or equal to the exhaust high temperature protection value by
230 for 10 consecutive seconds, an high exhaust temperature alarm occurs and
the compressor stops. At this time, controller shows high temperature fault
alarm code “02E”. When the exhaust temperature drops back to 194, the alarm is
released and the normal temperature control function is restored. If high
temperature fault protection appears 3 times within half an hour, the
controller will lock the protection. And the compressor will be locked in the
shutdown protection state. At this time, only the shutdown and restarting can
unlock the compressor.
4) Water flow failure (water cycle model): After the circulating water pump
starts, it detects that the water flow switch is in the off state for 10
seconds, then heat pump stops. At this time, the controller displays the water
flow switch fault alarm code “01E”.Periodically (1 minute) restarts the water
pump and 10 seconds later, the flow switch is detected. If water flow switch
is closed, heat pump will goes to normal running. If the fault occurs 3 times
within 1 hour, the fault is locked and heat pump will not starts.
6) Low ambient temperature protection: When the ambient temperature is 15.8,
the compressor is prohibited from running. When the ambient temperature is
19.4, normal operation is resumed, This protection has no fault display.
7) Water temperature too low protection at cooling mode(water cycle heat pump)
In the cooling mode with compressor running for 5 minutes, if detects that the
outlet water temperature is <41 for continuous 5 seconds, heat pump enters
subcooling protection. The compressor and the fan stop running, And the water
pump operates normally. When the outlet water temperature is detected to be
44.6 , heat pump exits the subcooling protection and enters normal operation.
8) Water temperature too high protection at heating mode (water cycle heat
pump) In the heating mode, after compressor running for 5 minutes, if the
water temperature is detected by continuous 5S 149, it is judged that the
outlet water temperature is too high. It will shutdown heat pump for
protection and when the outlet water temperature is detected to be 140 , the
protection is withdrawn. 9) Temperature sensor failure: Heat pump will stop
once the water tank temperature sensor or outlet water temperature sensor or
ambient temperature sensor is faulty. When absorb or exhaust or evaporator
coil or water return temperature sensor is faulty, electric heater is allowed
to operate.
When the return water temperature sensor fails, the return pump is allowed to run (do not judge the return water temperature) When the water tank or ambient temperature sensor are faulty, electric heating operation is not allowed. “11E”, “12E”, “13E” “, “14E”, “15E”, “17E”, “18E”, “19E”. are correspondingly displayed when the coil temperature sensor, ambient temperature sensor, exhaust temperature sensor, inlet water temperature sensor/tank temperature sensor, absorb temperature sensor, and outlet water temperature sensor/return water temperature sensor are faulty.
- Other: “09E” is displayed when the communication between the main control board and the wire controller is abnormal or the data line is not connected normally. “–:–” is displayed when the valid clock cannot be obtained. And the communication indicator of the main control board flashes. The buzzer sounds when an alarm occurs. Press any key to silence the alarm. The fault code table is as follows:
Error code
name
01E
Water flow switch disconnected(water cycle heat pump)
02E
Exhaust temperature too high
03E
High pressure switch failure
04E
Low pressure switch failure
09E
Communication failure
11E
Evaporator coil temperature sensor failure
12E
Ambient temperature sensor failure
13E
Exhaust temperature sensor failure
14E
Water inlet temperature sensor failure
15E
Tank temperature sensor failure
16E
17E
Absorb temperature sensor failure
18E
Water outlet temperature sensor failure
19E
Return water temperature sensor failure
20E
Outlet water temperature too high protection(water cycle heat pump)
21E
Outlet water temperature too low protection(water cycle heat pump)
9. Adjusting and Initial operation
9.1 Attention Within 12 hours after running, please connect the circuit
breaker, and make the crankcase heater be pre-heated. Open the valve of water
system, and the valve of assistant tank, inject water into the system, and
exhaust air inside. Do adjustment after electrical safety inspection. After
the power is switched on, start the test running of heat pump, to see if it
can function well. Forced operation is forbidden, because it is very dangerous
to work without protector. 9.2 Preparation Before Adjustment The system is
installed correctly. Tubes and lines are putted in the right place.
Accessories are installed. Ensure the smooth drainage. Ensure the perfect
insulation. Correct connection of ground lead. The supply voltage can meet the
requirement of rated voltage. Air inlet and outlet function can work well.
Electrical leakage protector can work well. 9.3 Adjustment Process Check if
the switch of the line controller can work well. Check if the function keys of
the line controller can work well. Check if the indicator light can work well.
Check if the drainage system can work well. Check if the system can work well
after starting up. Check if the water outlet temperature is acceptable. Check
if there is vibration or abnormal sound when the system is functioning. Check
if the wind, noise and condensate water produced by the system affect the
environment around. Check if there is refrigerant leakage. If any fault
occurs, please check the instructions first, to analyze and remove the fault.
10. Operation and maintenance
10.1 Personals shall possess professional knowledge or operate according to
professionals from our company. To ensure the well functioning, the system
shall be checked and maintained after a period of time. During the
maintenance, please pay attention to some points below:
Control and protect the equipment, please do not adjust any settings
discretely.
Pay close attention to whether all the operation parameters is normal during
system working.
Examine regularly whether the electrical connection is loose, if yes, fasten
it on time.
Examine regularly the reliability of the electrical components, change all the
failed or unreliable components on time.
There will be calcium oxidized or other mineral substance deposition on the
surface of water heat ex-changer copper coil after long period of operation,
which will influence the heat exchange performance and lead to high electrical
consumption, discharge pressure increasing and air suction pressure drop, unit
hot water volume produced is less. We can adopt formic acid, citric acid,
acetic acid or other organic acid to clean.
The dirt retention on the surface of evaporator fin should be blowed by more
than 0.6Mpa compressor air, brushed by fine copper wire, or flushed by high
pressurized water, usually one time per month; if too much dirt, we can use
paintbrush dipping gasoline to clean.
After long downtime, if we restart the equipment, we should make following
preparations: examine and clean the equipment carefully, clean the water
pipeline system, examine the water pump, and fasten all the wire connections.
Replacement parts must use our company original accessories, can not be
replaced by other similar accessories.
10.2 Refrigerant filling
Examine the refrigerant filling condition through reading the data of liquid
level from display screen, also the air suction and exhaust pressure. If there
is leakage or changing components of the refrigeration circulation system, we
have to make air tightness examination first.
10.3 Leak detection and air tightness experiment:
During leak detection and air tightness experiment, never let the
refrigeration system filling oxygen, ethane or other flammable harmful gas, we
can only adopt compressed air, fluoride or refrigerant for such experiment.
10.4 To remove the compressor, please follow the following steps
Turn off the power supply
Exhaust the refrigerant from the low pressure end, attention to reduce the
exhaust speed, and avoid frozen oil leakage.
Remove the compressor air suction and exhausting pipe.
Remove the compressor power cables.
Remove the compressor fixing screws.
Remove the compressor.
10.5 Conduct regular maintenance according to the user manual instruction, to
make sure the unit running in good condition.
Fire prevention: if there is a fire, please turn off the power switch
immediately, put the fire out with fire extinguisher.
To prevent flammable gas: the unit working environment should stay away from
gasoline, ethyl alcohol and other flammable materials, to avoid explosion
accident.
Malfunction: if malfunction occurs, should find out the reason, eliminate it
and then reboot the unit. Never boot the unit forcibly if the malfunction has
not been eliminated. If refrigerant leakage or frozen liquid leakage, please
turn off all the power switch, if the unit can not stop buy controlling
switch, please turn off the general power switch.
Never short connect the wire for protection required device, or else, in case
unit malfunction, it can not be protected normally and will damage the unit.
11. Fault analysis and elimination method
12. Technical parameter
Air-source Swimming Pool Heat Pump
Model
Heating capacity (Btu/h)
80 Air 80 Water 63% RH
Power input (Btu/h)
Cop
Heating capacity (Btu/h)
50 Air 80 Water 63% RH
Power input (Btu/h)
Cop
Power supply
Max power input(Btu/h)
Max current(A)
Setting temperature range(Heating)
Setting temperature range(Cooling)
Running (Air) temperature range
Refrigerant type/quantity (Oz)
Air side heat exchanger
Water side heat exchanger
Water flow(gpm)
Net dimension LxWxH(inch)
Packing dimension LxWxH(inch)
Net Weight(lbs)
Packing Weight(lbs)
Maximum working pressure of heat exchanger
Maximum working pressure of exhaust side
Maximum working pressure of suction side
Noise
YC-007 3000 5087 5.9
19500 4850 4.02
208~230V/60Hz 6850 11
46~104 46~82
19.4~109.4 R410A/38.8Ozs Hydrophilic fin exchanger Titanium tube exchanger
15.4 40x17x24 44x19x30
154 174 4.4Mpa 4.4Mpa 2.5Mpa 55dB(A)
After-sale service
If your hot water heater can not operate normally, please turn off the unit
and cut off the power supply at once, then contact with our service center or
technical department.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>