villastar YC-005 Mini Pool Heat Pump Instruction Manual

June 17, 2024
villastar

villastar YC-005 Mini Pool Heat Pump

villastar-YC-005-Mini-Pool-Heat-Pump-PRO

Product Information

Specifications

  • Model: YC-005
  • Heating Capacity: 16036 Btu/h (80’F Air, 80’F Water, 63% RH)
  • Power Input: 3599 Btu/h
  • COP: 4.45
  • Power Supply: 110-120V/60Hz
  • Max Power Input: 4623 Btu/h
  • Max Current: 7.1A
  • Noise Level: 50dB(A)
  • Net Weight: 59 lbs
  • Maximum Working Pressure of Heat Exchanger: 4.4 MPa
  • Maximum Working Pressure of Exhaust Side: 4.4 MPa
  • Maximum Working Pressure of Suction Side: 2.5 MPa

Product Usage Instructions

  • Material Preparation Before Installation
    Ensure all necessary materials are ready and follow the installation guidelines provided.

  • Installation Steps
    Follow the step-by-step instructions in the manual to properly install the heat pump in the recommended location.

  • Electrical Wiring
    Refer to the wiring diagram provided in the manual and ensure proper electrical connections are made. Ground the unit for safety.

  • Operation
    Once installed, power on the heat pump and set the desired temperature range for heating or cooling as needed.

  • Maintenance
    Regularly check for any faults or error codes displayed on the unit. Clean filters and ensure proper airflow for efficient operation.

FAQ

Q: What should I do if there is no display on the LED wire controller?

  • Observation: LED wire controller shows no display.
  • Reason: No power supply.
  • Solution: Check the cable connection and circuit breaker to ensure they are properly connected.

Thank you very much for purchasing our product, please keep this installation manual carefully and read this manual carefully before you install heat pump.

If you have any questions, you can contact us through the following ways
Website: www.villastarheatpump.com
E-mail: sales@villastarheatpump.com

Product Introduction

villastar-YC-005-Mini-Pool-Heat-Pump- \(1\)

Dimension

Packing List

villastar-YC-005-Mini-Pool-Heat-Pump- \(3\)

After unpacking, please check the appearance sheet metal of the unit, whether the fan blades and evaporator are damaged, and whether the accessories are complete. If there is any problem, please contact the aftersales service for replacement.

Installation Location and Specifications

WARNING

  1. The heat pump must be installed outdoors. Do not install it indoor.villastar-YC-005-Mini-Pool-Heat-Pump- \(4\)
  2. The unit needs to be kept a certain distance from the surrounding.

If you have to set power supply outside, you must install an outdoor cover with waterproof IPX6 for power plug.
Power Specifications: 120V/60Hz

Please disconnect the water hoses and drain water out to prevent the unit from freezing damage during winter time.villastar-YC-005-Mini-Pool-Heat-Pump-
\(7\)

Typical installaton for above ground pool
Note: The heat pump unit needs to be installed on a flat platform, such as a concrete floor, to ensure that the unit operates on a horizontal platform .villastar-YC-005-Mini-Pool-Heat-Pump- \(8\)

Material preparation for above-ground swimming pool installation: In addition to the swimming pool host, the following materials should also be purchased for the installation of the unit;

  1. Piping parts: Three or more piping parts need to be purchased respectively. It is recommended to use plastic hose 1-1/2″ (DN40)according to the below diagram. The heat pump unit is installed within 10ft of the swimming pool, the farther away from the swimming pool, the greater the heat loss;
  2. The pipe connection needs customer to purchase 6 (DN40) hose clamps, which are respectively installed at each nozzle position;
  3. Swimming pool and swimming pool cover; (for dustproof and heat preservation, the effect of adding a swimming pool cover will be better during the heating process.)
  4. It is necessary to purchase a swimming pool water pump with hair treatment, the flow rate is ≥12gpm;
  5. Other equipment for swimming pools, such as chlorinators, can be purchased as needed;
  6. Tools need Phillips screwdriver and pipe wrench.

Typical installaton for in- ground pool
Material preparation for underground swimming pool installation: In addition to the swimming pool host, the following materials should also be purchased for the installation of the unit;villastar-YC-005-Mini-Pool-Heat-
Pump- \(9\)

  1. Piping parts: PVC 1-1/2″ (DN40) piping parts are required respectively. Refer to the installation diagram 2. The length of the pipe should be selected according to the specific location of the site. It is recommended that the heat pump unit be installed within 10ft of the swimming pool, away from the swimming pool. The farther away, the greater the heat loss;
  2. It is necessary to purchase 6 PVC (DN40) joints and 3 valves for the connection of pipeline parts, and the number of additional equipment shall be purchased according to the needs of the site;
  3. Swimming pool cover; (for dustproof and heat preservation, it will be better to add a swimming pool cover during the heating process.)
  4. It is necessary to purchase a swimming pool water pump with hair treatment, the flow rate is ≥12gpm;
  5. Other equipment for the swimming pool, such as chlorinators, filter sand tanks, etc., can be purchased as needed;
  6. Tools need Phillips screwdriver and pipe wrench, PVC paste glue.

Installation Steps

  1. When the swimming pool heat pump main unit, pipe fittings and supporting materials, water pump materials, and swimming pool are ready, please place them in a reasonable position. The heat pump main unit needs to be installed on a flat platform and cannot be skewed; it is recommended that the heat pump unit be installed within 10ft of the swimming pool. The further away the pool, the greater the heat loss;
  2. According to the connection system diagram, connect the pipe fittings and hose clamps in sequence;
  3. Add water to the swimming pool. The water volume of the swimming pool should be greater than the water inlet and outlet of the swimming pool. Make sure that the water pump, heat pump host and pipe fittings are filled with water;
  4. To turn on the water pump, it is necessary to ensure that the water flow is normal;
  5. The swimming pool heat pump plug is connected to the power supply, and the power specification is 120V/60HZ;
  6. Press the switch key of the heat pump main unit to start the machine. When the unit is running, there will be a normal sound and the condensed water will be discharged from the bottom hole. The condensed water must be drained;
  7. The heat pump unit controller operates as follows:
    • Control panel introductionvillastar-YC-005-Mini-Pool-Heat-Pump- \(10\)
    • Power On: Press “ ” to turn on/off the heat pump.
    • Mode switch: Press “ ” to change mode, cooling “ ”, heating “ ” and AUTO “ ” + “ ”.
    • Temperature adjustment: Press “ ”or “ ” directly to adjust the desired water temperature, the data will be saved in 3 seconds.

Fault Codes and Solutions

Error code on the LED controller

Malfunction Code Reason Solution
Water temperature sensor failure P1 Water temperature sensor open circuit or
short circuit. 1.  Check the sensor wiring.

2.  Replace the new water temperature sensor.

Piping temperature sensor failure| P3| Piping temperature sensor open circuit or short circuit.| 1.  Check the sensor wiring.

2.  Replace the new piping temperature sensor.

Ambient temperature sensor failure| P5| Ambient temperature sensor open circuit or short circuit.| 1.  Check the sensor wiring.

2.  Replace the new water temperature sensor.

Too low or too high ambient temperature protection| E0| 1. Ambient temperature is out of operating range: 23°F~109.4°F.

2.  Controller failure.

| 1.  Wait the ambient temperature recover the operation range.

2.  Replace the new controller.

Water flow failure| E3| 1.  Insufficient or no water flow.

2.  The wiring for water flow switch is in loose situation.

3.  Malfunction of water flow switch

| 1.  Check the water pump or water piping system.

2.  Check the wiring of water flow switch.

3.  Replace a new water flow switch

Other malfunctions and solutions (No display on LED wire controller)

Malfunction Observing Reason Solution
Heat pump is not running LED wire controller no display. No power supply

Check cable and circuit breaker if it is connected
LED wire controller displays the actual water temperature.| 1.  Water temperature is reaching to setting value, HP under constant temperature status.

2.  Heat pump just starts to run.

| 1.  Verify water temperature setting.

2.  Start up heat pump after a few minutes.

Short running| LED displays actual water temperature, no error code displays.| 1.  Fan NO running.

2.  Air ventilation is not enough.

| 1.  Check the cable connections

between the motor and fan, if necessary, it should be replaced.

2.  Check the location of heat pump unit and eliminate all obstacles to make good air ventilation.

Water stains| Water stains on heat pump unit.| 1.  Concreting.

2.  Water leakage.

| 1.  No action.

2.  Check the titanium heat exchanger carefully if it is any defect.

Note: If the above contents could not solve the problem you are faced with, please feedback on this website: http://mail.villastarheatpump.com After receiving your feedback, we will follow up and respond back with the answers in time.

Electrical Wiring

Swimming pool heat pump wiring diagram:villastar-YC-005-Mini-Pool-Heat-Pump-
\(18\)

NOTE:

  1. Above electrical wiring diagram only for your reference, please subject machine posted the wiring diagram.
  2. The swimming pool heat pump must be connected to ground wire well, although the unit heat exchanger is electrically isolated from the rest of the unit. Grounding the unit is still required to protect you against short circuits inside the unit. Bonding is also required.
    Disconnection: A disconnection means (circuit breaker, fused or un-fused switch) should be located within sight of and readily accessible from the unit. This is common practice on commercial and residential heat pumps. It prevents remotely-energizing unattended equipment and permits turning off power at the unit while the unit is being serviced.

Technical Parameter

Technical data pool heat pumps

  • Below data is subject to modification without prior notice:

Air-source Swimming Pool Heat Pump

Model| YC-005
80’F Air 80’F Water 63% RH| Heating capacity (Btu/h)| 16036
Power input (Btu/h)| 3599
COP| 4.45
50’F Air 80’F Water 63% RH| Heating capacity (Btu/h)| 10747
Power input (Btu/h)| 3070
COP| 3.50
Power supply| 110-120V/60Hz
Max power input (Btu/h)| 4623
Max current (A)| 7.1
Setting temperature range (Heating)| 59°F~104°F
Setting temperature range (Cooling)| 46°F~82°F
Running (Air) temperature range| 23°F~109.4°F
Refrigerant type/quantity (Oz)| R410A/15.90 Ozs
Air-side heat exchanger| Hydrophilic fin exchanger
Water-side heat exchanger| Titanium tube heat exchanger
Water flow (gpm)| 9.3
Net dimension L×W×H (inch)| 16.5×14.2×17.8
Packing dimension L×W×H (inch)| 18.9×17.1×19.0
Net weight (lbs)| 59
Packing weight (lbs)| 66
Maximum working pressure of heat exchanger| 4.4 MPa
Maximum working pressure of exhaust side| 4.4 MPa
Maximum working pressure of suction side| 2.5 MPa
Noise| 50dB(A)

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals