AVB 4X Self Contained Cleaning Machine
Sharon Brush/ AVB 4X
Version 08/02
USING AND MAINTENANCE MANUAL FOR THE SELF-CONTAINED CLEANING MACHINE
READ CAREFULLY BEFORE USING THE MACHINE
Generalities
The body of the carpet cleaning machine Sharon-Brush is composed by two high- density polyethylene tanks, kept together with elastic hooks. The upper tank is meant to contain the dirty water sucked from the carpet, while the lower tank is meant to contain clean water and detergent. The lower tank also contains the vacuum motor, the pump and the control panel. The vacuum head, the spray nozzle and the rotating brush are situated below the lower tank.
Safety instructions (read carefully)
Every electrical device must be used for its particular function only,
respecting the manufacturer’s instructions. Failure to adhere to the
instructions could result in serious person injury, electric shock, fire or
explosion.
The nowadays machines are normally produced according to the accident
prevention regulations and are often homologated by qualified institutes for
the safety, but nobody and nothing can save irresponsible users from danger.
Please, read carefully the following points and be sure to understand
everything before using the machines. The following information signals
potentially dangerous conditions to the operator or equipment.
WARNING: Fire or Explosion Hazard.
- Do not spray water near electrical outlets.
- Do not use the machine to spray or to suck dust, corrosive liquids (acids or bases) and explosive or inflammable liquids.
- Do not use the machine in an explosive atmosphere. This machine is not equipped with an explosion proof motor. The electric motor will spark when powered on which could cause a flash fire or explosion if machine is used in an area where flammable vapors/liquids or combustible dusts are present.
- Never use flammable liquids or operate machine in or near flammable liquids, vapors or combustible dusts.
WARNING: Electrical Hazard.
- Before putting the machine’s plug in the current socket, check that the voltage available is the same indicated on the label of the machines.
- Be sure that the electrical system is well earthed and that it has a safety differential switch.
- Verify that the cable plug is complying with the outlet.
- Do not modify plug.
- Do not use adapters or multiple sockets, without knowing the electrical input of each user.
- If any electrical extension is used, check that it corresponds to the absorbed power of the machine and that the connection of the plug with the socket is complying and sealed.
- Take care of the electrical cable. It must be integral and protected from water, tears and chemical agents. Do not repair the cable in case of tears, but replace it with a new one. The cable must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
- Do not pull the cable to drag the machine or to pull the plug out.
- Pull the plug out only when the machine is switched off.
- Do not handle the plug with wet hands.
- Unplug cable before servicing machine.
FOR SAFETY:
- Do not let the machine being used by children and people unable to understand the danger connected with the use of electrical power.
- Do not bring the end of the suction hose or one of the accessories near your face or others’, particularly near ears and eyes: the sucked air could seriously damage them.
- If the machine is used as a wet vacuum cleaner, you must check the level of water in the recovery tank, in order to prevent water from being sucked by the vacuum motor.
- If the chemical you are using produces foam, or if you are cleaning carpet previously treated with shampoo, you must put some antifoaming liquid into the recovery tank. In the long run, the foam sucked by the motor can damage it.
- In case of abnormal working (very noisy motor, not running pump, extreme temperature rise, or other suspicious signals) switch off the machine and pull the plug out.
- If foam or liquid escapes from the machine, switch machine off immediately.
- After using, store the machine, well cleaned, in a cool and dry place. The manufacturer cannot be held responsible for any damage/injury caused to persons or property, because of the incorrect use of the machine due to procedures being used which are not specified in this instruction manual.
Attention: all the electrical repairs must be performed by qualified
personal only!
PROTECT THE ENVIRONMENT
Please dispose of packaging materials and old machine components in a safe
environmentally way according to your local waster disposal regulations.
**** Always remember to recycle.
Preparation for Work
The carpet cleaning machine Sharon-Brush is designed to clean large areas of
carpet and hard floor, even without using external accessories, since the
washing device is situated below the body of the machine (see paragraph Use as
a Self-contained Machine).
It is also possible to clean upholstery, inside of cars or hard-to-reach
areas, by using additional accessories, which must be connected to the machine
with connecting hoses (see paragraph Use with Accessories).
The following steps explain the necessary operations to prepare the machine
for use:
-
Put the machine in the normal working position and regulate the height of the handle.
-
Fill in the lower tank (solution tank) with cold or warm water, through the filling hole, adding a 5% of not-foaming detergent (1/2 liter each 10 liters). Higher concentrations can be used in case of particularly dirty surfaces. Attention: wool carpet must be washed with cold water only!
While filling the lower tank, pay attention to avoid overfilling the tank and to prevent water from going outside the appropriate filling hole. Always keep in mind the dangers connected with the use of electrical device. -
Close the filling hose with the cap.
-
Insert the plug of the cable into a wall socket (see Safety Regulations).
Use as a Self-contained Machine
In this modality the machine washes and dries with the spray nozzle and the
vacuum head which are situated below the body of the machine.
To switch on the machine you must act on the switches on the control panel:
- Set to position “I” the switch of the vacuum motor.
- Set to position “I” the pump switch. In this way the solution pump works only while you rotate the hand grip of the machine.
- To clean carpets, rotate the lever on the vacuum head towards the right side. To clean hard floors, rotate it towards the left side.
- To activate the rotating brush switch on the power brush motor, act on the correspondent luminous switch, located in the nearby of the vacuum head.
Attention: Do not use the machine as a vacuum cleaner!
Do not let the pump function without water! Check periodically the level of
water in the lower tank, while using the machine. As soon as it becomes empty
you must switch off the machine, empty the upper tank (which then will be
full) and fill again the lower tank before activating the pump.
Attention: Keep an adequate distance from other people. Pay attention to
any object that could hit by the machine. Never leave the machine unguarded.
Use with Accessories
In this modality the machine works as a classical extractor, for which you
clean a surface by using accessories which are external to the machine body.
After filling the tanks with solution and inserting the plug in the wall
outlet (see the Paragraph Preparation for work), you need to perform the
following operations:
- Connect the machine to the wand or to the hand-tool using the solution and the vacuum hoses. To connect the hoses to the machine, remove the vacuum hose, which connects the upper tank to the vacuum head, and the solution hose, which connects the pump to the spraying nozzle, situated under the machine. By doing so, Sharon-Brush becomes a classical carpet extractor. At this point it is possible to connect the accessories to the machine, through the special connecting hoses.
- Switch on the vacuum motor by setting their switch to position “I”, and the pump by setting the switches to position “II”. In this way the solution pump always works and it is not necessary to keep pressed the control lever situated on the control panel.
- To spray water you need to press the lever situated on the handle of the accessory.
Working method
As regards the use as a self-contained machine, considering a rectangular surface, we suggest you to proceed in parallel stripes, spraying and sucking the solution at the same time. Proceed at a speed suitable with the dirt of the surface. In case of persistent spots, you can apply locally a pure detergent. There are also spray bottles on market, with detergents, which are specific for a particular kind of spot. Choose high-quality detergents only in order to avoid any damage to the surface. Always make a test in an area where an eventual damage is less visible.
Maintenance
The model Sharon-Brush is a professional machine. The warranty on these
machine is of 1 year and regards the faults due to manufacturing defects. The
faults due to improper use are not covered by warranty. For further details
regarding warranty, contact the distributor supplying the machine.
For a good preservation and a long duration of the machine, observe the
following advice:
- After every use, before storing the machine, remove all the water from the solution and the recovery tank. Put some liters of clean water into the solution tank and use the pump only, pressing the lever of the solution valve. This operation is useful to clean the internal parts of the pump, of the couplings and nozzles, removing the detergent residues.
- After every use, store the machine in a cool and dry place with the cover open, to avoid that humidity inside the recovery tank can condensate on the internal parts of the vacuum motor, therefore damaging it. The damage provoked by humidity that condenses on the motor (like the damage caused by the foam sucked by the motor) is not covered by warranty.
- Periodically clean the water filter, extracting it from the machine and rinsing it under current water.
- Check and periodically clean the filters of the vacuum motor, that are located in the transparent cover of the recovery thank.
- Eliminate the lime that in time deposits inside the hydraulic circuit of the machine, by putting some anti-lime solution in the solution tank and leave it for some hours. Then empty the tank and rinse. It is enough to perform this operation every 6-8 months.
- Periodically check the consume of the carbon brushes of the vacuum motor and of the brush motor. This check should be done after 500 working hours. Consumed carbon brushed may result in a damage to vacuum motor or pump, which are not covered by warranty. The check of carbon brushes should be done by technical personnel.
- Periodically check that the brush rotates without problems, eliminating the causes which prevent a free rotation. In case of difficulties, contact the technical assistance.
DECLARATION OF CONFORMITY
We :
SANTOEMMA srl
Via Piave 22/C
20016 PERO (Milano)
declare under our responsibility that the product
Spray extractor for carpet and hard floor SHARON-BRUSH
To which this documentation relates is in conformity with the following
European Directives and their modifications: EC 2006/42; 2006/95; 2004/108.
The European regulations in force are:: EN60335-1:2008; EN60335-2-69:2009; EN
60704-3; EN55014-1:2008 + EN55014-2:1998 + A1:2008 + EN61000-3-2:2006 +
EN61000-3-3:1995 + A1:2001 + A1:2005 + EN50366 + EN30366/A1.
Ing. Nicola Santoemma
Owner Manual Page 36 of 36
Via Piave, 22/C – 20016 PERO (Milano) – Italy
Tel. +39.02.3391 2487 Fax +39.02.3391 2538
www.santoemma.com
E-mail:santoemma@santoemma.com
Milano, 01/02/2010
Documents / Resources
|
NACECARE AVB 4X Self Contained Cleaning
Machine
[pdf] User Manual
AVB 4X Self Contained Cleaning Machine, AVB 4X, Self Contained Cleaning
Machine, Cleaning Machine, Machine
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>