FANIMATION FP810 Air Shadow Glass Bowl Ceiling Fan Owner’s Manual

June 17, 2024
FANIMATION

The Air Shadow™

Glass Bowl Ceiling Fan

WARNING: Support Directly From Building Structure

Net Weight 17.24 kg (38 lbs)

Model No. FP810**

OWNER’S MANUAL

READ AND SAVE THESE INSTRUCTIONS

For Canada, this fan must be secured directly to the building structure or ceiling joist.
Don’t secure this fan to an outlet box.

Important Safety Instructions

WARNING: To avoid fire, shock and serious personal injury, follow these instructions.

  1. Read your owner’s manual and safety information before installing your new fan. Review the accompanying assembly diagrams.
  2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel.
  3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off the power to the ceiling fan before servicing.
  4. Do not insert anything into the fan blades while the fan is operating.
  5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions

1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not operate fan without blades.
2. All wiring and installation procedures must satisfy National Electrical Codes (ANSI/ NFPA 70-1999) and Local Codes. The ceiling fan must be grounded as a precaution against possible electrical shock. Electrical installation should be made or approved by a licensed electrician.
3. The fan base must be securely mounted and capable of reliably supporting at least 50 lbs. (fan and accessories not to exceed 50 lbs. or 22.7 kgs.). See page 4 of owner’s manual for support requirements. Consult a qualified electrician if in doubt.
WARNING: Mount only to an outlet box marked acceptable for fan support.
4. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental contact with the fan blades.
5. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not have adequate electrical knowledge or experience, have your fan installed by licensed electrician.
6. Suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with Fan Speed Control Part No. UC7067RC, manufactured by Rhine Electronic Co., Ltd.
WARNING: TO REDUCE THE RISK OF SHOCK, THIS FAN MUST BE INSTALLED WITH AN ISOLATING WALL CONTROL/SWITCH.
WARNING: This product is designed to use only those parts supplied with this product and/or accessories designated specifically for use with this product. Using parts and/or accessories not designated for use with this product could result in personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade bracket (flange or blade holder) when installing the brackets, balancing the blades, or cleaning the fan. Do not insert foreign objects in between rotating fan blades.

LIMITED LIFETIME WARRANTY

Extends to the original purchaser of a Fanimation Fan

  1. LIMITED LIFETIME MOTOR WARRANTY – If any part of your fan motor fails, due to a defect in materials or workmanship during the lifetime of the original purchaser, Fanimation will provide the replacement part free of charge, when the defective fan is returned to our national service center. Proof of purchase is required. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement.
  2. ONE YEAR MOTOR LABOR WARRANTY – If your fan motor fails at any time within one year from the original purchase, due to defects in materials or workmanship, labor to repair the motor will be provided free of charge at our national service center. Purchaser will be responsible for labor charges after this one-year period. Customer shall be responsible for all costs incurred in the removal or reinstallation and shipping of the product for repairs or replacement.
  3. If any other part of your fan fails at any time within one year after original purchase, due to a defect in materials or workmanship, we will repair, or replace, at our option, the defective part free of charge for parts and labor performed at our national service center.
  4. Because of varying climate conditions, this warranty does not cover changes in the finish, including rusting, pitting, corroding, tarnishing, or peeling.
  5. This warranty is void and does not apply to damage from improper installation, neglect, accident, misuse, exposure to extremes of heat or humidity, or as a result of any modification to the original product.
  6. All costs of removal and reinstallation of the fan are the sole responsibility of the owner of the fan and not the store that sold the fan or Fanimation.
  7. Fanimation reserves the right to modify or discontinue any product at any time and may substitute any part under this warranty.
  8. Under no circumstances may a fan be returned without prior authorization from Fanimation. The receipt of purchase must accompany authorized returns and must be sent freight prepaid to Fanimation. The fan to be returned must be properly packed to avoid damage in transit; Fanimation will not be responsible for any damage resulting from improper packaging.
  9. It is understood that any repair or replacement is the exclusive remedy available from Fanimation. There is no other expressed or implied warranty. Fanimation hereby disclaims any and all implied warranties, including, but not limited to those of merchantability and fitness for a particular purpose to the extent permitted by law. Some states do not allow limitations on implied warranties. Fanimation will not be liable for incidental, consequential, or special damages arising out of or in conjunction with product use or performance, except as may otherwise be accorded by law. This warranty gives you special legal rights and you may also have other rights that vary from state to state.
  10. A certain amount of wobble is normal and should not be considered a problem or a defect.

This Manual is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate, and Maintain Your Ceiling Fan

Tools Needed for Assembly
  • One Phillips head screwdriver
  • One stepladder
  • One ¼˝ blade screwdriver
  • One wire stripper
  • Three wire connectors
    (supplied)

WARNING


Before assembling your ceiling fan, refer to section on proper method of wiring your fan (page 4). If you feel you do not have enough wiring knowledge or experience, have your fan installed by a licensed electrician.

Materials

Wiring outlet box and box connectors must be of type required by local code. The minimum wire would be a 3conductor (2-wire with ground) of the following size:

Installed Wire Length           Wire Size A.W.G.
Up to 50 ft.                            14
50 – 100 ft.                             12

NOTE: Place the parts from the loose parts bags in a small container to keep them from being lost. If any parts are missing, contact your local retailer.


Unpacking Instructions

For your convenience, check-off each step. As each step is completed, place a check mark. This will ensure that all steps have been completed and will be helpful in finding your place should you be interrupted.

WARNING


Do not install or use fan if any part is damaged or missing. This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Fanimation. Substitution of parts or accessories not designated for use with this product by Fanimation could result in personal injury or property damage. Contact your retail store for missing or damaged parts.

1. Check to see that you have received the following parts:

NOTE: If you are uncertain of part description, refer to exploded view illustration. (Figure 1, page 13)

  • Fan Motor assembly
    – Support Safety Cable bag

  • Light Kit / Parts assembly

  • Internal Housing

  • Adapter Switch Cup

  • Glass Bowl

  • Hanger Bracket

  • Downrod/Hanger Ball assembly

  • Ceiling Canopy

  • Motor Coupling Cover

  • C28 Remote Control

  • Receiver Unit

  • Hardware bags:
    – Two 5/32″ threaded rods
    – Two 5/32″ lockwashers
    – Two knurled knobs
    – Three 3/16″ screws
    – Three 3/16″ lockwashers
    – Seven wire nuts
    – Phillips screwdriver, 4″
    – Rubber Washer
    – Finial nut
    – Six 5/32″ screws
    – Three 5/32″ lockwashers
    – Two wire nuts

Hanger Bracket                                Ceiling Canopy

Downrod/Hanger Ball Assembly       Motor Coupling Cover

Receiver Unit                                         C28 Remote Control

Adapter Switch Cup                             Switch Cup Light Kit

Fan Motor Assembly                                  Internal Housing

Finial Nut                                               Hardware Bag

Glass Bowl (AM-Amber Glass or PT-Parrot, shown)


Electrical and Structural Requirements

Your new ceiling fan will require a grounded electrical supply line of 120 volts AC, 60 Hz, 15 amp circuit. The outlet box must be securely anchored and capable of withstanding a load of at least 22.7 kgs (50 lbs). Figure 1 depicts different structural configurations that may be used for mounting the outlet box.

WARNING


To reduce the risk of fire, electrical shock, or personal injury, mount fan to outlet box marked acceptable for fan support of 22.7 kg (50 lbs) or less. Use screws supplied with outlet box. Most outlet boxes commonly used for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult a qualified electrician if in doubt.

If your fan is to replace an existing light fixture, turn electricity off at the main fuse box at this time and remove the existing light fixture.

WARNING


Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.

Figure 1

  1. Ceiling Joists
  2. Ceiling
  3. 2″ x 4″
  4. Outlet Box

WARNING


To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.


How to Assemble Your Ceiling Fan

1. Prior to assembly, set aside and save the hardware bag(s) packed in the packing.

2. Remove the Hanger Ball by loosening the setscrew in the Hanger Ball until the ball falls freely down the Downrod. (Figure 1) Remove the Pin from the Downrod, then remove the Hanger Ball. Retain the Pin and Hanger Ball for reinstallation in Step 8.

3. The fan comes with blue, black, gray and white 80″ wires. Separate and untwist the wires. Route the wires through the Downrod.

NOTE: You will be using either the 6″ downrod supplied with your fan or an optional downrod purchased separately.

4. Position Fan/Motor Assembly on styrofoam pedestal, for ease of assembly.

5. Loosen the two setscrews in the Downrod Support. Align the Clevis Pin holes in the Downrod with the holes in the Downrod Support. Install the Clevis Pin and secure with the Hairpin Clip. (Figure 2) Be sure to push the straight leg of the hairpin clip through the hole near the end of the clevis pin until the curved portion of the hairpin clip snaps around the clevis pin. The hairpin clip must be properly installed to prevent the clevis pin from working loose. Pull on the Downrod to make sure the clevis pin is properly installed. (Figure 2)

Figure 1

  1. Setscrew
  2. Pin
  3. Hanger Ball

Figure 2

  1. Downrod Support
  2. Motor Coupling Cover
  3. Hairpin Clip
  4. Clevis Pin
  5. Setscrew (2)

6. Route wires through opening in Motor Coupling Cover. Position Motor Coupling Cover on fan shown with open side facing down. (Figure 2)

7. Route wires through opening in Canopy. Position Canopy on fan shown with open side facing up. (Figure 3)

8. Reinstall the Hanger Ball (Figure 3) on the Downrod as follows. Route the three 80″ wires through the Hanger Ball. Position the Pin through the two holes in the Downrod and align the Hanger Ball so the Pin is captured in the groove in the top of the Hanger Ball. Pull the Hanger Ball up tight against the pin. Securely tighten the setscrew in the Hanger Ball. A loose setscrew could create fan wobble.

WARNING


It is critical that the clevis pin in the downrod support is properly installed and the setscrews are securely tightened. Failure to verify that the pin and setscrews are properly installed could result in the fan falling.

9. While pulling up on the hanger ball, securely tighten the two 3/16-24 x 3/8″ setscrews in the downrod support. (Figure 2)

NOTE: The setscrews must be properly installed as described above, or fan-wobble could result.

10. Slide the Motor Coupling Cover down until it touches the top of the Housing. (Figure 3)

11. The fan comes with blue, black, gray and white leads. Before installing fan, measure up approximately 6-9 inches above top of Downrod/Hanger Ball Assembly. Cut off excess wire and strip back insulation ½” from end of wire.

12. You have now completed the assembly of your new ceiling fan. You can now proceed with the hanging and the electrical wiring of your fan.

Figure 3

  1. Downrod/Hanger Ball Assembly
  2. Ceiling Canopy
  3. Motor Coupling Cover

How to Hang Your Ceiling Fan

WARNING


To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before hanging.
NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.

WARNING


The fan must be hung with at least 7′ of clearance from floor to blades (Figure 1)

WARNING


The outlet box must be securely anchored and capable of withstanding a load of at least 50 lbs. Hanger bracket must seat firmly against outlet box. If the outlet box is recessed, remove wallboard until bracket contacts box. If bracket and/or outlet box are not securely attached, the fan could wobble or fall.

1. Using the ⅜” x 2″ lag bolt and flat washer, attach safety cable to ceiling joist or wood structural member. The lag bolt will pass through the flat washer, safety cable loop, the junction box and into the building structure (Figure 2). You will first drill a ¼” pilot hole into the building structure to prevent splitting or cracking.

2. Securely attach the hanger bracket to ceiling junction box acceptable for ceiling support.

NOTE: Ceiling support cable cannot be secured to junction box only, it must be directly secured to ceiling joist or structural member using the ⅜” x 2″ lag bolt and flat washer. (Figure 2).

3. Make sure the electrical supply wires, including the hanger bracket grounding wire and safety cable are pulled through the downrod, between the hanger bracket and the junction box so that electrical connections can be made later.

4. Carefully lift the fan and seat the downrod/hanger ball assembly on the hanger bracket that was just attached to the ceiling joist. Be sure the groove in the ball is lined up with tab on the hanger bracket. (Figure 3)

5. Attach the safety cable to ceiling support cable. Slide cable clamp onto safety cable (from fan). Place the end of cable through the loop of ceiling support cable. Pull as much cable through loop as possible. Feed end of cable into clamp hole and firmly tighten screw (Figure 3). Cut off excess safety cable.

WARNING


Failure to seat tab in groove could cause damage to electrical wires and possible shock or fire hazard.

WARNING


To avoid possible shock, do not pinch wires between the downrod/hanger ball assembly and the hanger bracket.

F igure 1

  1. No less than 7 ft
  2. Floor

F igure 2

  1. Wood Member
    (2″ x 4″ Approx.)

  2. Ceiling Joist

  3. Junction Box

  4. Hanger Bracket

  5. Ceiling Support Cable

  6. Ceiling

F igure 3

NOTE: Supply wires and fan wires omitted for clarity

  1. Downrod/Hanger Ball Assembly
  2. Tab
  3. Attach Safety Cable to Ceiling Support Cable

How to Wire Your Ceiling Fan – C28 Remote Control

If you feel that you do not have enough electrical wiring knowledge or experience, have your fan installed by a licensed electrician.

WARNING


To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring.
NOTE: If you are not sure if the outlet box is grounded, contact a licensed electrician for advice, as it must be grounded for safe operation.

1. Setting the Code: The remote unit has 16 different code combinations. It may be necessary to test a couple frequency code settings to improve signal reception and/or eliminate interference from other remote control household items. Multiple fans should have different code settings to allow independent fan control. To set the code, perform these steps.

  • Transmitter: remove battery cover. Press firmly below arrow and slide battery cover off. Slide code switches to your choice of up or down position. Factory setting is all up. Do not use this position. With a small screwdriver or ball point pen slide firmly up or down (Figure 1a). Replace battery cover on the transmitter.
  • Receiver: Slide code switches to the same positions as set on your transmitter (Figure 1b).

2. Installing Receiver in Hanger Bracket:

  • Slide remote Receiver into the Hanger Bracket (Figure 2).
  • Connect wires as indicated: (Figure 3)
  • Green Hanger Bracket & Hanger Ball wires to BARE (ground) wire.
  • BLACK Receiver Unit wire (AC IN L) to BLACK supply wire.
  • WHITE Receiver Unit wire (AC IN N). to WHITE supply wire.
  • WHITE Receiver Unit wire (TO MOTOR N) to WHITE fan wire.
  • BLACK Receiver Unit wire (TO MOTOR L) to BLACK fan wire.
  • BLUE Receiver Unit wire (FOR LIGHT DOWN) to BLUE light wire.
  • GRAY Receiver Unit wire (REVERSE MODULE) to GRAY wire.
  • Position all connected wires and receiver antenna to allow installation of ceiling canopy.
  • Using canopy screws threaded into the hanger bracket install ceiling canopy. (see page 8)

3. After making the wire connections, the wires should be spread apart, turned upward and pushed carefully up into the outlet box, with the grounded conductor and the equipment-grounding conductor on one side of the outlet box and the ungrounded conductor on the other side of the outlet box.

F igure 1a                          Figure 1b

  1. Remote Transmitter Unit Detail
  2. 9V Battery
  3. Reciever Unit Detail

NOTE: If fan or supply wires are different colors than indicated, have this unit installed by a qualified electrician.

F igure 2

NOTE: Receiver wires omitted for clarity.

  1. Ceiling
  2. Receiver Unit
  3. Bracket (Open End)

F igure 3

  1. GRN from hanger ball
  2. GRN from bracket
  3. GRN or BARE GROUND
  4. WH-TO MOTOR N
  5. BLK-TO MOTOR L
  6. GRAY-REVERSE MODULE
  7. BLUE-FOR LIGHT DOWN
  8. WH-AC IN N
  9. BL-AC IN L
  10. BLK-ANT
  11. 120 VAC SUPPLY
    (User Supplied)

WARNING


Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until the blades is in place. Noise and fan damage could result.


How to Operate Your C28 Remote Control

1. Operating & Using Remote Transmitter (Figure 1): Install 9 volt battery (If not using for long periods of time, remove battery to prevent damage to transmitter). Store the transmitter away from excess heat or humidity.

  • HI Push Button – high fan speed
  • MED Push Button – medium fan speed
  • LOW Push Button – low fan speed
  • OFF Push Button – fan off
  • REV Push Button – toggles between air upflow and air downflow
  • *Demo Push Button – on/off auto demo mode
  • Light Push Button – on/off and brightness control for optional down light.

To control either light hold down key to increase or decrease brightness. Tap key quickly to turn light on or off. The light keys have auto resume and will stay at the same brightness as the last time it was turned off.

F igure 1

*Demo mode is initiated by pressing the Demo button on the remote, lights will flash 3 times. Fan runs for 2½ minutes then shuts off for ½ minute. The 2 ½ / ½ minute run cycles continue until any other button is pressed on the remote control.


Installing the Canopy Housing

NOTE: This step is applicable after the necessary wiring is completed. (see page 7)

WARNING


To avoid possible fire or shock, make sure that the electrical wires are completely inside the canopy housing and not pinched between the housing and the ceiling.

1. Screw in two threaded rods into the Hanger Bracket (Figure 1a).

NOTE: The threaded rods in the hanger bracket serve as guides for easier installation.

2. Securely attach the Canopy Housing to the Hanger Bracket using the external lockwashers and knurled knobs supplied with your fan (Figure 1b).

F igure 1a                            Figure 1b

NOTE: Supply wires and fan wires omitted for clarity.


Maintenance

Periodic cleaning of your new ceiling fan is the only maintenance that is needed.
When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish.
Abrasive cleaning agents are not required and should be avoided to prevent damage to finish.

CAUTION

Do not use water when cleaning your ceiling fan. It could damage the motor or the finish and create the possibility of electrical shock.


Blade Cleaning

Periodic light dusting of the blades is recommended.
A feather duster will work best.

Avoid using water, cleansers, or harsh rags, which can warp and ruin the blade and the finish.


Trouble Shooting

WARNING

For your own safety turn off power at fuse box or circuit breaker before trouble shooting your fan.
Trouble| Probable Cause| Suggested Remedy
---|---|---
1. FAN WILL NOT START| 1. Fuse or circuit breaker blown.

2. Loose power line connections to the fan, or loose switch wire connections in the switch housing.

3. Dead battery in remote control.

| 1. Check main and branch circuit fuses or circuit breakers.

2. Check line wire connections to fan and switch wire connections in the switch housings.

CAUTION: Make sure main power is turned off !

3. Replace with fresh battery.

2. FAN SOUNDS NOISY| 1. Loose screws in motor housing.

2. Wire connectors inside housing rattling.

3. Motor noise caused by solid state variable speed control.

4. Screws holding blades to blade holders are loose.

5. Lower housing support set screw loose.

| 1. Check to make sure all screws in motor housing are snug (not over- tight).

2. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing.

CAUTION: Make sure main power is turned off !

3. Some fan motors are sensitive to signals from solid-state variable speed controls. Solid-state controls are not recommended, choose an alternative control method.

4. Tighten screws securely.

5. Tighten set screw securely.

3. FAN WOBBLES EXCESSIVELY| 1. Setscrew in downrod support is loose.

2. Setscrew in downrod/hanger ball assembly is loose.

3. Screws securing fan blade holders to motor hub are loose.

4. Hanger bracket and/or ceiling outlet box is not securely fastened.

| 1. Tighten both setscrews securely in downrod support.

2. Tighten the setscrew in the downrod/hanger ball assembly.

3. Check to be sure screws which attach the fan blade holders to the flywheel are tight.

4. Tighten the hanger bracket screws to the outlet box, and secure outlet box.

4. NOT ENOUGH AIR MOVEMENT| | 1. If possible, consider using a longer downrod. For example, use a 12” downrod instead of the 6” downrod that comes with your fan.


Installing the LK810**

CAUTION

Turning off wall switch is not sufficient. To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. All wiring must be in accordance with National and Local codes and the ceiling fan must be properly grounded as a precaution against possible electrical shock.
WARNING

To avoid fire or shock, follow all wiring instructions carefully. Any electrical work not described in these instructions should be done or approved by a licensed electrician.

F igure 1

1. Locate accessory mounting plate on bottom of fan.

F igure 2

2. Mount internal housing unit on accessory mounting plate with 3 screws and 3 lockwashers provided, in bag labeled “Housing to Motor Assembly”.

F igure 3

3. Install switch cup adapter on the internal housing unit with 3 screws and 3 lockwashers provided.

F igure 4

4. Locate white and blue wires labeled “FOR LIGHT”. Connect white-to- white and blue-to-black wires with wire nuts supplied.

F igure 5

5. Install light fixture to adapter with 3 screws provided.

F igure 6

6. Install five-60 watt candelabra bulbs (not included).

F igure 7

INSTALLATION NOTE

HEAVY! Requires 2 people to hang the glass bowl.

7. Assemble and install glass bowl with rubber washer, and finial nut, do not over-tighten.

Parts List

Model #FP810**

Ref. #

| Description|

Part #

---|---|---
| Retractable Fan Assembly – Glass Bowl|

FP810**

FAN MOTOR ASSEMBLY — MAR20CY

5

| Retractable Fan Motor Assembly|

10

| Control Receiver|

RECCAN57DEMO

11

| Remote Control|

C28

| Support Cable Bag Containing:|
Ceiling Support Cable
Cable Clamp
Flat Washer
Lag Bolt, ⅜” x 2”

GLASS BOWL LIGHT KIT ASSEMBLY — LK810**

6

| Internal Housing|

P81070WH

7

| Adapter Switch Cup|

P81085BL

8

| Switch Cup Light Assembly|

AP81056WH

1

| Hanger Bracket Assembly|

APG610BL

2

| Ball/Downrod Assembly|

ADR1x6**

3

| Ceiling Canopy|

PG165**

4

| Motor Coupling Cover|

P81090**

9

| Glass Bowl, (PT-Parrot, shown) or (AM-Amber Glass)|

8

| Hardware Bag(s) Containing:|

HDWLK810**

Rubber Washer
Wire Nut (7)
Finial Nut
Canopy Hardware Bag Containing:
5/32” Threaded Rods (2)
5/32” External Lockwasher (2)
Knurled Knobs (2)
Housing Mount Hardware Bag Containing:
3/16” Pan Head Screw (3)
3/16” External Lockwasher (3)
Phillips Screwdriver, 4”
Adapter Mounting Hardware Bag Containing:
5/32” Pan Head Screw (6)
5/32” External Lockwasher (3)
Wire Nut (2)

**Insert FINISH CODES (Refer to fan model number located on downrod support)

Before discarding packaging materials, be certain all parts have been removed

How To Order Parts

Contact your retail store for repair parts.
When ordering repair parts, always give the following information.

  • Part Number
  • Part Description
  • Fan Model Number
The Air Shadow Fan FP810**

Exploded-View

F igure 1

NOTE: The illustration shown is not to scale or its actual configuration may vary

10983 Bennett Parkway
Zionsville, IN 46077
888-567-2055
FAX866-482-5215
Outside U.S. call317-733-4113
Visit Our Websitewww.fanimation.com

Copyright 2007 Fanimation                                             2007/01

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

FANIMATION User Manuals

Related Manuals