CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module Instructions
- June 17, 2024
- Corning
Table of Contents
**CORNING DHRU-G2-17 HRU Digital High Power Amplifier Module Instructions
**
Case
2×2 MIMO Case
2TO1 2×2 MIMO Case
4TO1 2×2 MIMO Case
Refer to the table below for Everon™ 6000 Parameters.
Everon™ 6000 Parameters_Build 9_V1.
Release Version
SN | Unit | Version |
---|---|---|
1 | RIU-TDD | 23.4.1.11_Everon_6000_RIU_P2.V01.00.00.11 |
2 | RIU-FDD | 23.4.1.11_Everon_6000_RIU_P2.V02.00.00.05 |
3 | DEU-25G | 23.4.1.11_Everon_6000_DEU_P2.V01.00.03.87 |
4 | DEU-10G | 23.4.1.11_Everon_6000_DEU_P2.V02.00.03. |
5 | DCU | 23.4.1.11_Everon_6000_DCU_P2.V01.00.03.83 |
6 | dLRU-3.5 | 23.4.1.11_Everon_6000_dLRUH_P2.V01.00.04.92 |
7 | dLRU-M | 23.4.1.11_Everon_6000_dLRUM_P2.V02.00.04.06 |
8 | dLRU-L | 23.4.1.11_Everon_6000_dLRUL_P2.V02.00.04.03 |
9 | dMRU-3.5 | 23.4.1.11_Everon_6000_dMRUH_P2.V01.00.03.51 |
10 | dMRU-FDD | 23.4.1.11_Everon_6000_dMRUF_P2.V02.00.00.46 |
11 | dHRU-FDD | 23.4.1.11_Everon_6000_dHRUF_P2.V01.00.01.68 |
12 | System Version | 23.4.1.11_Everon_6000_SYSTEM_P2.V01.04.03.38 |
LED Functionality and Color Definition
Optical LED definition
| | Green| Amber
---|---|---|---
( SYNC )| (LOS)
SFP Plug out| SFP Plug out| OFF| OFF
Optic Link Fail| 1. Optic cable disconnected| OFF| ON
| 2. SFP fail| OFF| ON
| 2.1 SFP fault| OFF| ON
| 2.2 SFP warning| OFF| ON
| 2.3 SFP alarm| OFF| ON
| 3. CPRI link down| OFF| ON
Optic Link OK| 1. Optic cable connected| ON| ON
| 2. SFP OK| ON| ON
| 3. CPRI link down| ON| ON
CPRI Link OK| 1. Optic cable connected| ON| OFF
| 2. SFP OK| ON| OFF
| 3. CPRI link up| ON| OFF
ALM/RUN/Power LED definition
LED | Description | Color |
---|---|---|
____ ALM | 1. Alarm | Red |
2. Device detect (Identify and is controlled from DCU) | Red Flash (1Hz, 10s) | |
3. No alarm | OFF | |
__ RUN | 1. The system is up and running | Green Flash(1Hz) |
2. Software or hardware failure | OFF | |
__ Power | 1. Power on | Green |
2. Power off | OFF |
Caution message: The device is restricted use of unauthorized antennas,
cables, and/or coupling devices which may cause device not conforming with
ERP/EIRP limit and rf exposure requirement.
Warning : this device is license operation and not support home/personal
use.
Warning! Each individual antenna used for this transmitter must be
installed to provide a minimum separation distance as below or more from all
persons and must not be co-located with any other antenna for meeting RF
exposure requirements.
Warning! Antenna gain should not exceed as below.
Model No. | distance | antenna gain |
---|---|---|
dHRU-G2-6 | 5.7m | 12.5dBi |
dHRU-G2-7 | 7.7m | 12.5dBi |
dHRU-G2-85 | 5.3m | 10dBi |
dHRU-G2-19 | 5.4m | 12.5dBi |
dHRU-G2-17 | 6.6m | 12.5dBi |
dHRU-G2-23 | 3.8m | 12.5dBi |
WARNING ACCORDING TO PART 20
WARNING! This is NOT a CONSUMER device. It is designed for installation by FCC
LICENSEES and QUALIFIED INSTALLERS. You MUST have an FCC LICENSE or express
consent of an FCC Licensee to operate this device. Unauthorized use may result
in significant forfeiture penalties, including nalties in excess of $100,000
for each continuing violation.
Corning Optical Communications LLC • 4200 Corning Place • Charlotte, NC 28216 USA 800-743-2675 • FAX: 828-325-5060 • International: +1-828-901-5000 • www.corning.com/opcomm Corning Optical Communications reserves the right to improve, enhance, and modify the features and specifications of Corning Optical Communications products without prior notification. A complete listing of the trademarks of Corning Optical Communications is available at www.corning.com/opcomm/trademarks. All other trademarks are the properties of their respective owners. Corning Optical Communications is ISO 9001 certified. © 2023 Corning Optical Communications. All rights reserved. LAN-3091-AEN / January 2023
References
- Corning Optical Communications | Fiber Optic Connectivity Solutions | Corning
- Legal Notices | Corning.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>