Hunter 19020 Hepburn Modern Glass Flush Mount Ceiling Light Installation Guide

June 17, 2024
Hunter

Hunter 19020 Hepburn Modern Glass Flush Mount Ceiling Light

Product Information

Specifications

  • Model Numbers: 19020, 19021, 19170, 19872
  • Weight: 2.4 lbs (1.09 kg)
  • Finish: Painted Modern Brass, Matte White, Matte Black
  • Glass Type: Cased White Glass

Product Usage Instructions

Preparing for Installation

  1. Ensure the power is turned off before starting the installation process.
  2. Clean the fixture gently to reduce the need for deep cleaning. Turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth.
  3. Do not spray cleaner directly onto the fixture to avoid damage.

Installation Steps

  1. Attach the mounting plate (B) to the junction box by tightening the screws (D).
  2. Refer to the specific model number for any additional installation steps:
    • Model 19020: [Additional installation steps for Model 19020]
    • Model 19021: [Additional installation steps for Model 19021]
    • Model 19170: [Additional installation steps for Model 19170]
    • Model 19872: [Additional installation steps for Model 19872]

Frequently Asked Questions (FAQ)

  • Q: How should I clean the fixture?
    A: For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Avoid spraying cleaner directly onto the fixture.

  • Q: How do I prevent chipping/breaking of the glass?
    A: To prevent chipping or breaking of the glass, do not overtighten screws during installation.

For Models:

  • 19020
  • 19021
  • 19170
  • 19872

TOOL NEEDED

Here are the tools you’ll need to complete your installation:

  • Ladder
  • Screwdriver
  • Pliers
  • Wire Strippers

1 Light Flush Mount

  • Fixture weight ±2 lbs: 2.4 lbs (1.09kg)

Hardware Service Kit

Part #

|

Model

|

Finish

 |  | Painted Modern Brass
KC04401864| 19020|
 |  | Matte White
KC04401893 | 19021 |
 |  | Brushed Nickel
__KC04401214
| 19170 |
 |  | Matte Black
__KC04401119
| 19872 __|
Glass

Part # Model

|

Type

 | 19020|
 | 19021|
 | 19170| Cased White Glass
KA28701045| 19872|

INSTALLATION INSTRUCTIONS

WARNING

  • To avoid possible electrical shock, before installing your light fixture, disconnect the power by turning off the circuit breakers to the outlet box associated with the wall switch location.
  • The lighting fixture must be grounded. If the ground wire for the installation site is not present, immediately STOP installation and consult a qualified electrician.
  • All wiring must be under national and local electrical codes ANSI/NFPA 70. If you are unfamiliar with wiring or in doubt, consult a qualified electrician.

READ AND SAVE THESE INSTRUCTIONS
These instructions are provided for your safety. They must be read carefully and completely before beginning the installation of the lighting fixture.

PREPARING FOR INSTALLATION

Carefully remove all contents from the carton. Shut off the power at the circuit breaker and completely remove the old fixture from the ceiling, including the old mounting bracket. Remove the new mounting bracket assembly from the bag. Remove cap nuts (G) from mounting screws (A). Place the mounting plate (B) over the junction box so that mounting screws (A) and nuts (C) extend out away from the ceiling. Pull the house wires through the center of the mounting plate (B). Adjust the position of mounting screws (A) so that mounting screws (A) can be exposed 5–6 mm after passing through the canopy (F) to properly fit the cap nuts. Mounting screws (A) can be adjusted by loosening nuts (C) and loosening or tightening mounting screws (A). Once the ideal position of mounting screws (A) has been confirmed, tighten nuts (C) on mounting screws (A) under the mounting plate to ensure that mounting screws (A) are in place. Secure mounting plate (B) to the junction box by tightening the screws (D).

CONNECTING THE WIRES

Have a helper support the fixture’s weight while completing the wiring. Attach the fixture wires to the power supply wires from the junction box. Connect black to black (live); white to white (neutral); grounding to grounding (green or copper). Twist the ends of the wire pairs together. Then, twist on a wire connector. Make sure all twists are in the same direction. Loop the fixture’s ground wire around the grounding screw (E) and tighten. If there is no ground wire (green or copper) from the junction box, contact a qualified electrician.

FINISHING THE INSTALLATION

  • Raise canopy (F) to mounting plate (B) and position mounting screws (A) so that they protrude through the openings of the canopy (F). Secure canopy (F) in place with cap nuts (G). lnstall light bulb (not included) under the fixture’s specifications. Do not exceed the recommended wattage.
  • Unscrew ring (I) from threads (N) and move the cover (J) back to expose the metal bracket (K). Put the metal bracket (K) into the glass (M) and adjust until both ends are in contact with the glass (M) and the flat base is parallel with the glass opening. Then tighten the ring (I) on threads (N) to secure the cover (J) and glass (M). Repeat for each fixture. Remove the glass before maintenance. Your installation is now complete. Turn on the power and test the fixture.

CLEANING TIPS

Treat the fixture gently! Regular cleaning will reduce the need for deep cleaning. For regular cleaning, turn off the light and wipe down the fixture with a clean lint-free cotton or microfiber cloth. Never spray cleaner directly onto the fixture.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals