PRODUCT

Product Information

The XenonTM XP 1952g/1952g-BF CCB01-010BT/CCB01-010BT-BF CCB-H-010BT/CCB-H -010BT-BF Cordless Area-Imaging Scanner and Charge Bases is a versatile scanning device that allows you to scan barcodes wirelessly. It comes with different base options for connectivity, including USB, Keyboard Wedge, RS232 Serial Port, and RS485. The scanner has a viewfinder that projects an aiming beam to ensure accurate scanning. It also features a Locked Link Mode to prevent other scanners from being linked to the base.

Specifications

  • Model: XenonTM XP 1952g/1952g-BF CCB01-010BT/CCB01-010BT-BF CCB-H-010BT/CCB-H-010BT-BF
  • Connectivity: Cordless
  • Scanner Options: USB, Keyboard Wedge, RS232 Serial Port, RS485
  • View Finder: Yes
  • Locked Link Mode: Yes

FAQ

  • Do I need to order the power supply separately?
    • The power supply must be ordered separately if needed.
  • What should I do if the scanner beeps 3 times when scanning a barcode?
    • If the scanner beeps 3 times, it means that the link has not been established. Ensure that the scanner is properly placed in the base to establish a link.
  • How do I reset the scanner to its standard product defaults?
    • Scan the barcode labeled “Standard Product Defaults” to reset the scanner to its default settings.
  • How do I program the scanner for a specific interface?
    • Refer to the User Guide for your product to find the appropriate barcode to scan and program the scanner for a specific interface.

Agency Model: 1952/1952-BF/ CCB-H-010BT/ CCB-H-010BT-BF

Note: Refer to your User Guide for information about cleaning your device.

Getting Started

  • Turn off computer’s power before connecting the scanner, then power up the computer once the scanner is fully connected.
  • When the base is connected and powered up, put the scanner in the base to establish a link. The green LED on the base flashes to indicate the scanner’s battery or charge pack is charging.

Power Supply Assembly (if included)

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-1

Note: The power supply must be ordered separately, if needed.

Connecting the Scanner USB

Note: If you are charging the scanner using the USB cable, the current available for charging is reduced and charge times are increased. Charging via the power supply is faster.

CCB01-010BT or CCB01-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-2

CCB-H-010BT or CCB-H-010BT-BF Base:

Keyboard Wedge

CCB01-010BT or CCB01-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-4

CCB-H-010BT or CCB-H-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-5

RS232 Serial Port:

CCB01-010BT or CCB01-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-6

CCB-H-010BT or CCB-H-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-7

RS485:

CCB01-010BT or CCB01-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-8

CCB-H-010BT or CCB-H-010BT-BF Base:

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-9

Reading Techniques

  • The view finder projects an aiming beam that should be centered over the bar code, but it can be positioned in any direction for a good read.

Note: If the scanner beeps 3 times when scanning a bar code, the link has not been established. If the scanner beeps once, the link has been established.

Standard Product Defaults

The following bar code resets all standard product default settings.

RS485 Interface

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-13

  • The RS485 interface defaults to port 5B. If you have an IBM POS terminal using port 9B, scan the appropriate code below to program the terminal, then power cycle the cash register.

Note

  • For additional RS485 interface selections, see the User Guide for your product.

USB Serial

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-14

  • If you are using a Microsoft® Windows® PC, you must download a driver from the Honeywell website. The driver will use the next available COM Port number.
  • Scan the following code to program the scanner to emulate a regular RS232-based COM Port. Apple® Macintosh computers recognize the scanner as a USB CDC class device and automati- cally use a class driver.

Note: No extra configuration (e.g., baud rate) is necessary.

USB PC Keyboard

  • Scan the following code to program the scanner for a USB PC Keyboard.

Keyboard Country

Scan the appropriate country code below to program the key- board layout for your country or language. By default, national character replacements are used for the following characters: #$@[\]^‘{|}~ Refer to the ISO 646 Character Replacements chart in your User Guide to view the character replacements for each country.

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-16 Honeywell-
CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-17

Note: For a complete list of country codes, see the User Guide for your product.

Locked

If you link a scanner to a base using the Locked Link Mode, other scanners are blocked from being linked if they are inadvertently placed into the base. If you do place a different scanner into the base, it will charge the scanner, but the scanner will not be linked. To use a different scanner, you need to unlink the original scanner by scanning the Unlink Scanner bar code.

Override Locked Scanner

If you need to replace a broken or lost scanner that is linked to a base, scan the Override Locked Scanner bar code with a new scanner, and place that scanner in the base. The locked link will be overridden; the broken or lost scanner’s link with the base will be removed, and the new scanner will be linked.

Unlinking the Scanner

  • If the base has a scanner linked to it, that scanner must be unlinked before a new scanner can be linked.
  • Once the previous scanner is unlinked, it will no longer communicate with the base. Scan the Unlink Scanner bar code to unlink a scanner.

Trigger

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-21

  • The following bar codes will allow you to use the scanner in Manual Trigger – Normal Mode (need to press the trigger to read) or Presentation mode (the scanner is activated when it “sees” a bar code).

Note

  • Presentation Mode continuously draws power, so use of the external power supply is recommended for this mode.

Streaming

  • When in Streaming Presentation mode, the scanner leaves the scan illumination on all the time and continuously searches for bar codes.

Suffix

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-23

  • If you want a carriage return after the bar code, scan the Add CR Suffix bar code.
  • To add a tab after the bar code, scan the Add Tab Suffix bar code. Otherwise, scan the Remove Suffix bar code to remove the suffixes.

Add Code ID Prefix to all Symbologies

  • Scan the following bar code if you wish to add a Code ID prefix to all symbologies at once.

Note: For a complete list of Code IDs, see the User’Guide for your product.

Function Code Transmit

When this selection is enabled and function codes are contained within the scanned data, the scanner transmits the function code to the terminal. Charts of these function codes are provided in your User Guide. When the scanner is in keyboard wedge mode, the scan code is converted to a key code before it is transmitted.

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-
FIG-25

Charge Pack Status

Charge Pack Status – Xenon XP 1952gBF only

The following charge status feedback is provided by a Xenon XP 1952fBF scanner when the scanner is out of the base and has been idle for 5 seconds.

Scanner LED| Scanner Beep| Charge

Level

| Approximate Expected
---|---|---|---
Yellow 3 sets of flashes| 2 short beeps per flash| 30%| 100
Red 3 sets of flashes| 2 short beeps per flash| 10%| 50

EZConfig-Scanning

  • To access additional features for the scanner, use EZConfig- Scanning, an online configuration software tool, available from our website.

Support

  • To search our knowledge base for a solution or to log into the Technical Support portal and report a problem, go to www.hsmcontactsupport.com.

Product Documentation

Limited Warranty

Patents

Product documentation is available at: www.honeywellaidc.com.

Publicly downloadable certificates are available at www.honeywellaidc.com/compliance.

FCC STATEMENT

FCC Part 15 Subpart B Class B

This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radiocommunications. However, there is noguarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the theequipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio or television technician for help.

If necessary, the user should consult the dealer or an experienced radio/television technician for additional suggestions. Honeywell International Inc. is not responsible for any radio or television interference caused by unauthorized modifications of this equipment or the substitution or attachment of connecting cables and equipment other than those specified by Honeywell International Inc.. The correction is the responsibility of the user.

RF Exposure

  • The equipment complies with FCC RF exposure limits set forth for an uncontrolled environment.
  • The equipment must not be co-located or operating in conjunction with any other antenna or transmitter

Caution: Any changes or modifications made to this equipment not expressly approved by Honeywell International Inc. may void the authorisation operate this equipment.

Canadian Compliance

This Class B digital apparatus complies with Canadian RSS-247. Operation is subject to the following conditions:

  1. This device may not cause harmful interference.
  2. This device must accept any interference received, including interference that may cause undesired operation.

IC RF Radiation Exposure

  • Radiation Exposure Statement
    • This equipment complies with IC radiation exposure limits set forth for an uncontrolled environment

TÜV R Statement

  • TÜV R listed: UL 60950-1, Second Edition and CSA C22.2
  • No.60950-1-07, Second Edition.

Use only shielded data cables with this system. This unit has been tested with cables less than 3 meters. Cables greater than 3 meters may not meet class A performance.

For patent information, refer to www.hsmpats.com.

Product Environmental Information

Class II

  • Frequency: 2402-2480 MHz
  • Maximum power: 20dBm

CAUTION: Improper battery replacement or incompatible device usage may result in risk of burns, fire, explosion, or another hazard. Dispose of batteries according to local regulations.

This document was prepared and executed in the English language. In the event this document is translatedinto another language and a conflict arises between the English version and a non-English version, the English version shall prevail, it is recognized and acknowledged that the English language version most clearly expresses the intent of the parties. Any notice or communication given in connection with this document must include a version in the English language.

For warranty information, go to www.honeywellaidc.com and click Get Resources

Product Warranty.

The following statements may not apply to products assembled in Mexico:

  • CB Scheme
    • Certified to CB Scheme IEC 62368- 1 and IEC 60950-1, Second Edition.

LED Safety Statement

  • LEDs have been tested and classified as“EXEMPT RISK GROUP” to the standard: IEC 62471:2006.

Honeywell International Inc., hereby declares that the radioequipment type, non-specific SRD, is in compliance with the following directives:

  • 2014/53/EU Radio Equipment
  • 2011/65/EU RoHS (Recast) The full text of the EU declaration of conformity is available at the following internet address: www. honeywellaidc.com/compliance.

European contact

  • Honeywell Productivity Solutions BV
  • Lagelandseweg 70
  • 6545CG Nijmegen The Netherlands

If the following label is attached to your product, the product meets Korean agency approval:

  • This product is EMC B grade equipment, intended for residential use.
  • This equipment can be used in any area.

(Model): 1952

(Names and Content of Hazardous Substances in the Product)

(Parts Name) (Hazardous Substances)
(Pb) (Hg)
(2D Imager) x
(PCB) x
(Housing) o
(Cables) o
(battery model) o

Disclaimer

Honeywell International Inc. (“HII”) reserves the right to make changes in specifications and other information contained in this document without prior notice, and the reader should in all cases consult HII to determine whether any such changes have been made. The information in this publication does not represent a commitment on the part of HII.

HII shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance, or use of this material. HII disclaims all responsibility for the selection and use of software and/or hardware to achieve intended results. This document contains proprietary information that is protected by copyright. All rights are reserved. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent of HII.

Copyright© 2019 Honeywell International Inc. All rights reserved.

Agency Model: 1952

Honeywell-CCB01-010BT-BF-Cordless-Area-Imaging-Scanner-and-Charge-Bases-