guardian technologies AC4825 Air Cleaning System Instruction Manual

June 17, 2024
guardian technologies

USE & CARE INSTRUCTIONS

AC4825 Air Cleaning System

Air Cleaning System
Model No. AC4825, AC5000 Series
3 (AC4825), 5 (AC5000) – Year Limited Warranty
Customer Service
1.866.603.5900
www.guardiantechnologies.com

Date Purchased month ____ year _____
English E – 1
Use GENUINE Guardian Technologies replacement parts only.
REV0920

READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may result in electric shock or serious injury.
This product should be used only in accordance with the specifications outlined in this manual. Usage other than what has been specified here may result in serious injury.

When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:

  • Read all instructions before using appliance.

  • IMPORTANT – This appliance has a polarized plug (one blade is wider than the other).
    To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature.

  • To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.

  • Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.

  • To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.

  • Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.

  • Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.

  • NEVER drop or insert any object into any openings.

  • DO NOT run cord under carpeting.

  • DO NOT cover cord with throw rugs, runners, or similar coverings.

  • DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.

  • DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.

  • Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.

  • DO NOT use outdoors.

  • DO NOT place anything on top of unit.

  • NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.

  • DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts.
    All servicing should be performed by qualified personnel only.

  • WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.

  • WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before replacing lamp or servicing.
    Replace Lamp With Lamp Manufactured by Guardian Technologies.

  • Always unplug the unit before before cleaning or servicing in any way.

  • CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
    The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m chamber.

The product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-hour period. The Health Canada Guideline 2010 recommends that the maximum exposure limit, based on averaging time of 8 hours,
is 0.020 ppmv or less when tested in a sealed, controlled room approximately 30 m³
WARNING: Cancer or Reproductive Harm.
For more information go to www.P65Warnings.ca.gov.

LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup 1-866-284-4010
This product earned the ENERGY STAR label by meeting strict energy efficiency guidelines set by the U.S. EPA. Room air cleaners have demonstrated the potential for improving air quality and providing health benefits. EPA does not endorse manufacturer claims regarding the degree to which a specific product will produce healthier indoor air. The energy efficiency of this ENERGY STAR certified model is measured based on a ratio between the model’s CADR for Smoke and the electrical energy it consumes, or CADR/Watt.

PRODUCT SPECIFICATIONS AND PARTS

REPLACEMENT PARTS

Filter Replacement Program ™
www.guardiantechnologies.com
IMPORTANT: Use Guardian Technologies GENUINE Replacement Parts only.
To Purchase Contact Customer Service

AIR CLEANING SYSTEM

Improve your indoor air quality with your new germguardian® Air Cleaning System. Multiple levels of cleaning include a combination filter that captures allergens, and Charcoal filter to remove odors.
UV-C light technology enhances germ-killing.
Pre-Filter – Captures initial dust and allergen particles.
Activated Carbon Filter – Charcoal/Activated Carbon contributes to the control and prevention of the growth of bacteria, germs and mold.
UV-C Light – UV-C light technology works with Titanium Dioxide (TiO ) to enhance the elimination of airborne germs. TiO2  is activated by the UV-C light to decompose remaining odor molecules caused by smoking, cooking and pets.
*Pre-Filter and Carbon Filter are combined into one layer that attaches to the Filter.

AIR CLEANING LAYERS

AC5000 SERIES

OPERATING INSTRUCTIONS

BEFORE OPERATING THE AIR PURIFIER:

  1. Carefully remove your air purifier from box and bag.
  2. Select a firm, level and at location for the air purifier .
  • For proper air flow, locate the unit at least 1 foot from any wall or furniture.
  • Make sure none of the grills are blocked. 3. Plug the power cord into a 120V AC outlet.

IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.

OPERATING INSTRUCTIONS

OPERATING THE AIR PURIFIER:

  1. Turn the air purifier ON by rotating POWER KNOB clockwise.
  2. Upon turning the air purifier ON, the power indicator will be lit (green) and the unit will be in LOW mode ( ).
  3. Rotate the POWER KNOB clockwise to set the air purifier to MEDIUM ( ) or High mode ( ).
  4. To activate the UV-C Bulb, press the UV button. Press the button again to turn OFF the UV-C Bulb.
  5. To turn the unit OFF, rotate the POWER KNOB counter-clockwise to OFF mode (•).

CHANGE FILTER INDICATOR

FILTER REPLACEMENT
The green power light on the air cleaner will turn red and flash continuously indicating that it is time to replace the filter. Replace the filter according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light will turn back to green. Depending on usage, filter will last approximately 6 months.

REPLACE FILTER

| |
---|---|---

  1. Turn off and unplug the unit.
  2.  Press the Lock & Release Button and remove the Rear Cover from the unit.
  3. Remove the used Combination Filter.
  4. Insert new Combination Filter into the unit. Consult the arrow on the filter for correct installation direction.
  5. Reattach the Rear Cover of the unit and securely latch into place.
  6. Push and hold UV Control Button for 5 seconds to reset Filter Change Indicator.

CHECKING AND MAINTAINING FILTER

Maintain the filter by checking it frequently.
Depending on air quality conditions, you may need to replace it more frequently.
Vacuum the carbon filter layer as needed to remove loose debris and dust and to help prolong the life of your filter.
To check the status of the filter, peel back the carbon layer to expose the pleated filter.
If the filter is no longer white and is covered in grey dust/dirt it should be replaced.
IMPORTANT: Do NOT try to wash and re-use the Combination Filter.
IMPORTANT: Use Guardian Technologies GENUINE Replacement Parts only.

INSTALLING & REMOVING UV-C BULB

CHANGE BULB INDICATOR
The blue light on the front of air cleaner will begin to flash continuously when it is time to replace the UV-C bulb. Replace the bulb according to the directions then press the UV control button and hold for 5 seconds to restart the system. The light should remain a constant blue.

REPLACE BULB

Continue reading below for remaining instructions on how to Install & Remove the UV-C Bulb for the AC4825 Series and the AC5000 Series.

  1. Remove the Rear Cover of the unit by pushing Lock & Release Button.

  2. After removing the Rear Cover from the unit, remove the Combination Filter.
    AC4825 SERIES Bulb is NOT visible until the UV-C METAL SHIELD has been removed.

  3. After removing the Combination Filter, use a Philips head screw driver to remove two (2) screws and detach the UV-C Metal Shield.

  4. The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.

  5. The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.

  6. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.

AC5000 SERIES

3.After removing the Combination Filter, use a Philips head screw driver to remove four (4) screws and detach the UV-C Metal Shield.
4. The UV-C Bulb is removed by carefully grasping the bulb with a  clean cloth or tissue and twisting the bulb 1/4 turn. Remove from unit.
5. The UV-C Bulb is reinstalled by reversing the process in Step 4.
6. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.
IMPORTANT: The UV-C Bulb should be replaced every 10 – 12 months depending on use.

TROUBLESHOOTING GUIDE

PROBLEM SOLUTION
Unit does not operate. Check that the unit is plugged in.

Check that filter is in place.
Confirm that filter is Genuine Replacement Filter
Call Customer Service.
Unit shuts off unexpectedly.| Check that unit is plugged into a working electrical outlet.
Check that filter is firmly in place.
Check that the Rear Cover is latched firmly in place.
Call Customer Service.
No air circulating from unit.| Unplug unit. Check Pre-/Carbon and filters.
Clean Pre-/Carbon Filter if necessary.
Replace filter if necessary.
Increase in noise level.| Make sure the filters are clean. Replace if necessary.
Power light is red and flashing.| Replace filter and reset system.
Blue UV-C light is flashing.| Replace Bulb and reset.

What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of filtered air delivered by an air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.

LIMITED WARRANTY

To the consumer, Guardian Technologies LLC warrants this product to be free of defects in materials or workmanship commencing upon the date of the original purchase. In order to be eligible for this Limited Warranty, an original sales receipt or comparable substitute proof of purchase bearing the date of original purchase is required. Refer to the original product carton or specific product/model page on the Guardian Technologies website for warranty length for your particular model. This warranty applies only to the original purchaser of this product from the original date of purchase. This warranty covers product purchased from authorized distributors only.
This warranty applies to repair or replacement of product found to be defective in materials or workmanship.
This warranty does not apply to damage resulting from unusual wear, commercial, abusive, unreasonable use or supplemental damage. This warranty does not cover damage from unauthorized repairs or from any use not in accordance with the instruction manual. Defects that are the result of normal wear and tear will not be considered manufacturing defects under this warranty.
If this product should become defective within the warranty period, we will repair or replace any defective parts free of charge. All warranty repairs must be completed by Guardian Technologies LLC. This warranty gives you specific legal rights and you may also have other rights (other rights may vary from state to state in the U.S.A.)
To submit product under warranty the complete machine must be delivered pre- paid to Guardian Technologies LLC. Please include complete information including: the problem, the model number of the product, the day of purchase, and a copy of the original sales receipt along with your name, address, and telephone (email optional). Address returns to the attention of: Customer Service, at the address below. Additional questions or comments can be made toll free to the number listed below.

USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to www.guardiantechnologies.com to register your product. We consider the registration process important to ensuring superior service to our customers, however submitting the warranty registration is optional and does not affect your rights to utilize this warranty according to the conditions stated above.
Additional copies of the instruction manual can be obtained by accessing and printing directly from our website or calling customer service.

©2016 Guardian Technologies LLC

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

guardian technologies User Manuals

Related Manuals