guardian technologies AC4825 Air Cleaning System Instruction Manual
- June 17, 2024
- guardian technologies
Table of Contents
- AC4825 Air Cleaning System
- PRODUCT SPECIFICATIONS AND PARTS
- AIR CLEANING SYSTEM
- AIR CLEANING LAYERS
- OPERATING INSTRUCTIONS
- CHANGE FILTER INDICATOR
- CHECKING AND MAINTAINING FILTER
- INSTALLING & REMOVING UV-C BULB
- TROUBLESHOOTING GUIDE
- LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
USE & CARE INSTRUCTIONS
AC4825 Air Cleaning System
Air Cleaning System
Model No. AC4825, AC5000 Series
3 (AC4825), 5 (AC5000) – Year Limited Warranty
Customer Service
1.866.603.5900
www.guardiantechnologies.com
Date Purchased month ____ year _____
English E – 1
Use GENUINE Guardian Technologies replacement parts only.
REV0920
READ AND SAVE THESE INSTRUCTIONS
WARNINGS
Failure to comply with the warnings listed below may result in electric shock
or serious injury.
This product should be used only in accordance with the specifications
outlined in this manual. Usage other than what has been specified here may
result in serious injury.
When using electrical appliances, basic precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
-
Read all instructions before using appliance.
-
IMPORTANT – This appliance has a polarized plug (one blade is wider than the other).
To reduce the risk of electric shock, this plug is intended to fit in a polarized outlet only one way. If the plug does not fit fully in the outlet, reverse the plug. If it still does not fit, contact a qualified electrician. Do not attempt to defeat this safety feature. -
To avoid fire or shock hazard, plug the appliance directly into a 120V AC electrical outlet.
-
Keep the cord out of heavy traffic areas. To avoid fire hazard, NEVER put the cord under rugs, near heat registers, radiator, stoves or heaters.
-
To protect against electrical hazards, DO NOT immerse in water or other liquids. Do not use near water.
-
Extreme caution is necessary when any appliance is used by or near children or people with disabilities and whenever the appliance is left operating unattended.
-
Always unplug the air purifier before moving it, opening the grill, changing filters, cleaning or whenever the air purifier is not in use. Be sure to pull by the plug and not the cord.
-
NEVER drop or insert any object into any openings.
-
DO NOT run cord under carpeting.
-
DO NOT cover cord with throw rugs, runners, or similar coverings.
-
DO NOT route cord under furniture or appliances. Arrange cord away from traffic area and where it will not be tripped over.
-
DO NOT operate any appliance with a damaged cord or plug, if motor fan fails to rotate, after the appliance malfunctions, or if it has been dropped or damaged in any manner. Call Customer Service at 1.866.603.5900 for assistance.
-
Use appliance only for intended household use as described in this manual. Any other use not recommended by the manufacturer may cause fire, electric shock or injury to persons.
-
DO NOT use outdoors.
-
DO NOT place anything on top of unit.
-
NEVER block the air openings, grills/outlets or place on a soft surface such as a bed or sofa, as this could cause the unit to tip over, blocking the air intake or outtake opening.
-
DO NOT attempt to repair or adjust any electrical or mechanical functions on this unit. Doing so will void your warranty. The inside of the unit contains no user serviceable parts.
All servicing should be performed by qualified personnel only. -
WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
-
WARNING: Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before replacing lamp or servicing.
Replace Lamp With Lamp Manufactured by Guardian Technologies. -
Always unplug the unit before before cleaning or servicing in any way.
-
CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the unit while cleaning as they will damage the product. NEVER use alcohol or other solvents.
The 8 hour TWA Ozone for this product is 0.001 ppmv when tested in a 30 m chamber.
The product complies with the maximum allowable concentration of ozone of
0.050 parts per million by volume (ppmv) in a 24-hour period. The Health
Canada Guideline 2010 recommends that the maximum exposure limit, based on
averaging time of 8 hours,
is 0.020 ppmv or less when tested in a sealed, controlled room approximately
30 m³
WARNING: Cancer or Reproductive Harm.
For more information go to
www.P65Warnings.ca.gov.
LAMP CONTAINS MERCURY
Manage in accordance with Spills, Disposal and Site Cleanup Requirements. In
case of breakage, follow clean-up procedures provided by contacts below.
www.epa.gov/cflcleanup
1-866-284-4010
This product earned the ENERGY STAR label by meeting strict energy efficiency
guidelines set by the U.S. EPA. Room air cleaners have demonstrated the
potential for improving air quality and providing health benefits. EPA does
not endorse manufacturer claims regarding the degree to which a specific
product will produce healthier indoor air. The energy efficiency of this
ENERGY STAR certified model is measured based on a ratio between the model’s
CADR for Smoke and the electrical energy it consumes, or CADR/Watt.
PRODUCT SPECIFICATIONS AND PARTS
REPLACEMENT PARTS
Filter Replacement Program ™
www.guardiantechnologies.com
IMPORTANT: Use Guardian Technologies GENUINE Replacement Parts only.
To Purchase Contact Customer Service
AIR CLEANING SYSTEM
Improve your indoor air quality with your new germguardian® Air Cleaning
System. Multiple levels of cleaning include a combination filter that captures
allergens, and Charcoal filter to remove odors.
UV-C light technology enhances germ-killing.
Pre-Filter – Captures initial dust and allergen particles.
Activated Carbon Filter – Charcoal/Activated Carbon contributes to the control
and prevention of the growth of bacteria, germs and mold.
UV-C Light – UV-C light technology works with Titanium Dioxide (TiO ) to
enhance the elimination of airborne germs. TiO2 is activated by the UV-C
light to decompose remaining odor molecules caused by smoking, cooking and
pets.
*Pre-Filter and Carbon Filter are combined into one layer that attaches to the Filter.
AIR CLEANING LAYERS
AC5000 SERIES
OPERATING INSTRUCTIONS
BEFORE OPERATING THE AIR PURIFIER:
- Carefully remove your air purifier from box and bag.
- Select a firm, level and at location for the air purifier .
- For proper air flow, locate the unit at least 1 foot from any wall or furniture.
- Make sure none of the grills are blocked. 3. Plug the power cord into a 120V AC outlet.
IMPORTANT: When moving the air purifier, always lift unit by the carrying handle located on back.
OPERATING INSTRUCTIONS
OPERATING THE AIR PURIFIER:
- Turn the air purifier ON by rotating POWER KNOB clockwise.
- Upon turning the air purifier ON, the power indicator will be lit (green) and the unit will be in LOW mode ( ).
- Rotate the POWER KNOB clockwise to set the air purifier to MEDIUM ( ) or High mode ( ).
- To activate the UV-C Bulb, press the UV button. Press the button again to turn OFF the UV-C Bulb.
- To turn the unit OFF, rotate the POWER KNOB counter-clockwise to OFF mode (•).
CHANGE FILTER INDICATOR
FILTER REPLACEMENT
The green power light on the air cleaner will turn red and flash continuously
indicating that it is time to replace the filter. Replace the filter according
to the directions then press the UV control button and hold for 5 seconds to
restart the system. The light will turn back to green. Depending on usage,
filter will last approximately 6 months.
REPLACE FILTER
| |
---|---|---
- Turn off and unplug the unit.
- Press the Lock & Release Button and remove the Rear Cover from the unit.
- Remove the used Combination Filter.
- Insert new Combination Filter into the unit. Consult the arrow on the filter for correct installation direction.
- Reattach the Rear Cover of the unit and securely latch into place.
- Push and hold UV Control Button for 5 seconds to reset Filter Change Indicator.
CHECKING AND MAINTAINING FILTER
Maintain the filter by checking it frequently.
Depending on air quality conditions, you may need to replace it more
frequently.
Vacuum the carbon filter layer as needed to remove loose debris and dust and
to help prolong the life of your filter.
To check the status of the filter, peel back the carbon layer to expose the
pleated filter.
If the filter is no longer white and is covered in grey dust/dirt it should be
replaced.
IMPORTANT: Do NOT try to wash and re-use the Combination Filter.
IMPORTANT: Use Guardian Technologies GENUINE Replacement Parts only.
INSTALLING & REMOVING UV-C BULB
CHANGE BULB INDICATOR
The blue light on the front of air cleaner will begin to flash continuously
when it is time to replace the UV-C bulb. Replace the bulb according to the
directions then press the UV control button and hold for 5 seconds to restart
the system. The light should remain a constant blue.
REPLACE BULB
Continue reading below for remaining instructions on how to Install & Remove the UV-C Bulb for the AC4825 Series and the AC5000 Series.
-
Remove the Rear Cover of the unit by pushing Lock & Release Button.
-
After removing the Rear Cover from the unit, remove the Combination Filter.
AC4825 SERIES Bulb is NOT visible until the UV-C METAL SHIELD has been removed. -
After removing the Combination Filter, use a Philips head screw driver to remove two (2) screws and detach the UV-C Metal Shield.
-
The UV-C Bulb is removed by carefully grasping the bulb with a clean cloth or tissue and pulling the bulb straight out of the unit.
-
The UV-C Bulb is reinstalled by sliding it, horizontally, back into the slots at the top of the unit.
-
Push and hold UV Control Button for 5 seconds to reset UV Bulb Change Indicator.
AC5000 SERIES
3.After removing the Combination Filter, use a Philips head screw driver to
remove four (4) screws and detach the UV-C Metal Shield.
4. The UV-C Bulb is removed by carefully grasping the bulb with a clean
cloth or tissue and twisting the bulb 1/4 turn. Remove from unit.
5. The UV-C Bulb is reinstalled by reversing the process in Step 4.
6. Push and hold UV Control Button for 5 seconds to reset UV Bulb Change
Indicator.
IMPORTANT: The UV-C Bulb should be replaced every 10 – 12 months
depending on use.
TROUBLESHOOTING GUIDE
PROBLEM | SOLUTION |
---|---|
Unit does not operate. | Check that the unit is plugged in. |
Check that filter is in place.
Confirm that filter is Genuine Replacement Filter
Call Customer Service.
Unit shuts off unexpectedly.| Check that unit is plugged into a working
electrical outlet.
Check that filter is firmly in place.
Check that the Rear Cover is latched firmly in place.
Call Customer Service.
No air circulating from unit.| Unplug unit. Check Pre-/Carbon and filters.
Clean Pre-/Carbon Filter if necessary.
Replace filter if necessary.
Increase in noise level.| Make sure the filters are clean. Replace if
necessary.
Power light is red and flashing.| Replace filter and reset system.
Blue UV-C light is flashing.| Replace Bulb and reset.
What is CADR?
CADR stands for “Clean Air Delivery Rate,” which indicates the volume of
filtered air delivered by an air purifier. CADR ratings show the effectiveness
of how efficient the air purifier is at capturing fine particles from things
like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at
suggested room size. Then refer to the Clean Air Delivery Rate (CADR) numbers.
The higher the number, the faster the unit filters the air.
Refer to website for individual model CADR numbers.
LIMITED WARRANTY
To the consumer, Guardian Technologies LLC warrants this product to be free of
defects in materials or workmanship commencing upon the date of the original
purchase. In order to be eligible for this Limited Warranty, an original sales
receipt or comparable substitute proof of purchase bearing the date of
original purchase is required. Refer to the original product carton or
specific product/model page on the Guardian Technologies website for warranty
length for your particular model. This warranty applies only to the original
purchaser of this product from the original date of purchase. This warranty
covers product purchased from authorized distributors only.
This warranty applies to repair or replacement of product found to be
defective in materials or workmanship.
This warranty does not apply to damage resulting from unusual wear,
commercial, abusive, unreasonable use or supplemental damage. This warranty
does not cover damage from unauthorized repairs or from any use not in
accordance with the instruction manual. Defects that are the result of normal
wear and tear will not be considered manufacturing defects under this
warranty.
If this product should become defective within the warranty period, we will
repair or replace any defective parts free of charge. All warranty repairs
must be completed by Guardian Technologies LLC. This warranty gives you
specific legal rights and you may also have other rights (other rights may
vary from state to state in the U.S.A.)
To submit product under warranty the complete machine must be delivered pre-
paid to Guardian Technologies LLC. Please include complete information
including: the problem, the model number of the product, the day of purchase,
and a copy of the original sales receipt along with your name, address, and
telephone (email optional). Address returns to the attention of: Customer
Service, at the address below. Additional questions or comments can be made
toll free to the number listed below.
USA and Canada
Guardian Technologies LLC
26251 Bluestone Blvd.
Euclid, Ohio 44132
1.866.603.5900
www.guardiantechnologies.com
Please go to
www.guardiantechnologies.com to
register your product. We consider the registration process important to
ensuring superior service to our customers, however submitting the warranty
registration is optional and does not affect your rights to utilize this
warranty according to the conditions stated above.
Additional copies of the instruction manual can be obtained by accessing and
printing directly from our website or calling customer service.
©2016 Guardian Technologies LLC
References
- Cleaning Up a Broken CFL | US EPA
- Lasko, GermGuardian, B-Air, BlueDri | Fans, Heaters, Air Purifiers – GuardianTechnologies
- P65Warnings.ca.gov
- Manual-Hub.com – Free PDF manuals!
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>