KING CANADA KCG-7501GE 7500W Gasoline Generator Instruction Manual

June 16, 2024
KING CANADA

KING CANADA KCG-7501GE 7500W Gasoline Generator

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-1

Specifications

  • Brand: King Canada
  • Model: KCG-7501GE
  • Power Output : 7500W
  • Starting Method: Electric Start
  • Additional Features: Wheel Kit

Product Usage Instructions

Safety Precautions

  • Read and understand the safety, operation, and maintenance instructions before operating the generator.
  • Do not use the generator in your house.
  • Do not use the generator in wet conditions.
  • Do not connect the generator to a household circuit.
  • Keep flammable materials away from the generator.
  • Stop the engine before refueling.
  • No smoking around the generator.
  • Avoid spilling gasoline.
  • Avoid touching the engine or muffler while they are still hot.

Basic Safety Information

  • Ensure there is sufficient fuel in the tank before operating the generator.
  • Ground the generator properly.

Specific Safety Information

  • Do not attempt to connect the generator directly to the electrical system of any building structure.
  • Backfeeding electricity through a building’s electrical system to outside utility feed lines can be dangerous.
  • Use a double throw transfer switch when connecting to a structure’s electrical system to avoid damage to appliances and voiding the manufacturer’s warranty.
  • Never backfeed electricity through a structure’s electrical system.
  • When connecting to a structure’s electrical system, always have a Double-Throw Transfer Switch installed by a qualified electrician and in compliance with local ordinances.
  • Ensure the engine muffler has cooled down before touching it.
  • Avoid operating the generator in rain, wet, icy, or flooded conditions.
  • Operate the generator in a clean, dry, well-ventilated area.
  • Ensure your hands are dry before touching the generator.

FAQ

  • Where can I find replacement parts for the generator?
    Replacement parts for this generator are available at authorized King Canada generator service centers across Canada. Please call the toll-free number provided in the manual to get servicing instructions and ensure you have your proof of purchase if you are claiming warranty work.

  • What is the warranty period for this generator?
    King Canada Tools offers a 1-year limited warranty for non-commercial use. Please keep your dated proof of purchase for warranty and servicing purposes.

  • Can I use this generator in my house?
    No, it is not recommended to use this generator in your house.

WARRANTY & SERVICE INFORMATION

1-YEAR LIMITED WARRANTY
FOR THIS 7500W GASOLINE GENERATOR
BEFORE CALLING THE ABOVE TOLL-FREE NUMBER, PLEASE READ THIS MANUAL, SPECIFICALLY THE SAFETY PRECAUTIONS, THE INSPECTION BEFORE OPERATION AND THE TROUBLESHOOTING GUIDE.
DO NOT RETURN THE DEFECTIVE PRODUCT TO THE RETAILER.

WARRANTY INFORMATION

PROOF OF PURCHASE
Please keep your dated proof of purchase for warranty and servicing purposes.

REPLACEMENT PARTS
Replacement parts for this generator are available at our authorized KING CANADA generator service centers across canada. For servicing, call the above toll free number to get servicing instructions and be sure to have your proof of purchase if you are claiming warranty work.

LIMITED TOOL WARRANTY
KING CANADA makes every effort to ensure that this product meets high quality and durability standards. KING CANADA warrants to the original retail consumer a 1-year limited warranty as of the date the product was purchased at retail and that each product is free from defects in materials.

THIS WARRANTY IS NOT TRANSFERABLE AND DOES NOT COVER

  • Damage or liability caused by shipping, improper handling, improper installation, improper maintenance, improper modification, or the use of accessories and/or attachments not specifically recommended.

  • Repairs necessary because of operator abuse or negligence, or the failure to install, operate, maintain, and store
    the product according to the instructions in the owner’s manual.

  • Damage caused by cold, heat, rain, excessive humidity, corrosive environments and materials, or other contaminants.

  • Expendable items that become worn during normal use such as fuel filters, air cleaners, spark plugs, and engine oil.

  • Cosmetic defects that do not interfere with product functionality.

  • Freight costs from customer to an authorized warranty service location.

  • Repair and transportation costs of products or parts determined not to be defective.

  • ANY INCIDENTAL, INDIRECT OR CONSEQUENTIAL LOSS, DAMAGE, OR EXPENSE THAT MAY RESULT FROM ANY DEFECT, FAILURE OR MALFUNCTION OF THE PRODUCT.

  • RETAIN THE ORIGINAL CASH REGISTER SALES RECEIPT AS PROOF OF PURCHASE FOR WARRANTY WORK.
    KING CANADA shall in no event be liable for death, injuries to persons or property or for incidental, special or consequential damages arising from the use of our products. Shipping and handling charges may apply. If a defect is found, KING CANADA will either repair or replace the product.
    KING CANADA TOOLS INC. MONTREAL, QUEBEC, CANADA H9P 2Y4

BASIC & SPECIFIC SAFETY PRECAUTIONS

BE CAREFUL!

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-2

WHEN REFUELING;

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-3

BASIC SAFETY INFORMATION
  • EXHAUST FUMES ARE DANGEROUS
    Never operate the engine in a closed area or it may cause unconsciensness and death within a short time. Operate in a well ventilated area.

  • FUEL IS HIGHLY FLAMMABLE AND POISONOUS

    • Always turn off the engine when refueling.
    • Never refuel while smoking or in the vicinity of an open flame.
    • When operating or transporting this generator, be sure to keep it upright. If it tilts, fuel may leak from the carburetor or fuel tank.
  • ENGINE AND MUFFLER MAY BE HOT

    • Place the generator in an appropriate location, away from children and pedestrians.
    • Avoid placing any flammable materials near the exhaust outlet during operation.
    • Keep a 4ft. clearance from buildings or other equipment around the generator to prevent overheating.
  • ELECTRIC SHOCK PREVENTION

    • Never operate in rain or snow.
    • Never touch the generator with wet hands or electric shock will occur.
    • Be sure to ground (earth) the generator.
  • ELECTRICAL CONNECTION NOTES

    • Avoid connecting the generator to commercial power outlet.
    • Avoid connecting the generator in parallel with any other generator.
      WARNING! The engine muffler will be very hot after use, avoid touching the engine or muffler while they are still hot.
  • FUEL
    Make sure there is sufficient fuel in the tank.

  • GROUNDING
    Make sure to ground the generator.

  • SPECIFIC SAFTEY INFORMATION

    • Attempting to connect generator directly to the electrical system of any building structure.
    • Back feeding electricity through a building’s electrical system to the outside utility feed lines could endanger repair persons attempting to restore service.
    • Failure to use a double throw transfer switch when connecting to a structure’s electrical system can damage appliances and WILL VOID the manufacturer’s warranty.
    • Never backfeed electricity through a structure’s electrical system. To connect to a structure’s electrical system in a safe manner, always have a Double-Throw Transfer Switch installed by a qualified electrician and in compliance with local ordinances. (When installing a Double-Throw Transfer Switch, a minimum of 10 gauge wiring must be used).

OPERATION OF GENERATOR IN RAIN, WET, ICY, OR FLOODED CONDITIONS.

  • Water is an excellent conductor of electricity! Water which comes in contact with electrically charged components can transmit electricity to the frame and other surfaces, resulting in electrical shock to anyone contacting them.
  • Operate generator in a clean, dry, well ventilated area. Make sure hands are dry before touching unit.

TAMPERING WITH FACTORY SET ENGINE SPEED SETTINGS.

  • Engine speed has been factory set to provide safe operation.
  • Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire.
  • Never attempt to “speed-up” the engine to obtain more performance.
  • Both the output voltage and frequency will be thrown out of standard by this practice, endangering attachments and the user.

IMPROPER CONNECTION OF ITEMS TO GENERATOR.
Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheating of some items or their attachment wiring resulting in fire or electrical shock. Make sure that the sum total of electrical loads for all attachments does not exceed the load rating of the generator.

ATTEMPTING TO FILL THE FUEL TANK WHILE THE ENGINE IS RUNNING.

  • Gasoline and gasoline vapors can become ignited by coming in contact with hot components such as the muffler, engine exhaust gases, or from an electrical spark.
  • Turn engine off and allow it to cool before adding fuel to the tank. Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires.

SPARKS, FIRE, HOT OBJECTS

  • Cigarettes, sparks, fires, or other hot objects can cause gasoline or gasoline vapors to ignite.
  • Add fuel to tank in well ventilated area. Make sure there are no sources of ignition near the generator.

INADEQUATE VENTILATION FOR GENERATOR

  • Materials placed against or near the generator or operating the generator in areas where the temperature exceeds 40° C ambient (such as storage rooms or garages) can interfere with its proper ventilation features causing overheating and possible ignition of the materials or buildings.
  • Operate generator in a clean, dry, well ventilated area a minimum of four feet from any building, object or wall. DO NOT OPERATE UNIT

INDOORS OR IN ANY CONFINED AREA. RISK OF BREATHING – INHALATION HAZARD

  • Operate generator in clean, dry, well ventilated area. Never operate unit in enclosed areas such as garages, basements, storage, sheds, or in any location occupied by humans or animals.
  • Keep children, pets and others away from area of operating unit.
  • Breathing exhaust fumes will cause serious injury or death. Gasoline engines produce toxic carbon monoxide exhaust fumes.

OPERATION OF VOLTAGE SENSITIVE APPLIANCES WITHOUT A VOLTAGE SURGE PROTECTOR.

  • Any gasoline operated household generator will incur voltage variations causing damage to voltage sensitive appliances or could result in fire.
  • Always use a U.L./CSA listed voltage sensitive surge protector to connect voltage sensitive appliances (TV, computer, stereo, etc.).
  • Failure to use a U.L./CSA listed voltage surge protector will void the warranty on your generator.
    Notice: A multiple outlet strip is not a surge protector. Make sure you use a U.L./CSA listed voltage surge protector.

USE OF WORN, DAMAGED, UNDERSIZED OR UNGROUNDED EXTENSION CORDS.

  • Contact with worn or damaged extension cords could result in electrocution. Use of undersize extension cords could result in overheating of the wires or attached items, resulting in fire. Use of ungrounded extension cords could prevent operation of circuit breakers and result in electrical shock.
  • Inspect extension cords before use and replace with new cord if required. Use proper size (wire gauge) extension cords for application as shown below. Always use a extension cords having a grounding wire with an appropriate grounding plug. DO NOT use an ungrounded plug. An extension cord that is hot to the touch is overloaded. Repair or replace damaged extension cords immediately.

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-4

GETTING TO KNOW YOUR GENERATOR

IMPORTANT
To obtain max wattage, use the standard 120V receptacles together with 120V L5-30 Nema receptacle as shown below. (Max 46A). *120V L5-30 Nema cable and plug not included.

Product Overview

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-5

  1. Fuel level indicator window with float gauge.
  2. Fuel cap. Make sure the fuel cap is always screwed on tightly.
  3. Fuel tank. Unleaded gasoline only! 25 Liter capacity.
  4. 1 of 2 Duplex AC 120V outlets. Plug up to 2-120V appliances or a power bar, make sure the amps requirement does not exceed max amps or else the AC breaker will automatically shut-off the power output.
  5. 20 Amp Reset. Resets the corresponding dual 120V AC outlet.
  6. AC Breaker. The AC breaker turns off automatically when the load exceeds the generator rated output. Reduce the load to within specified generator rated output if AC breaker turns off.
  7. Grounding terminal. This generator must be grounded, see grounding instructions.
  8. 10” Wheels.
  9. AC 120V/240V Twist lock outlet. This NEMA L14-30 twist lock outlet allows 120V or 240V operation, see instructions further in this manual.
  10. 20 Amp Reset. Resets the corresponding dual 120V AC outlet.
  11. Oil gauge dipstick. Check the oil level using this oil gauge dipstick.
  12. Frame supports.
  13. Low oil warning indicator light. This generator detects and shuts off automatically when the oil level is too low. In case of an auto shut-off and the indicator light is ON, check oil level with dipstick (#11) and fill to recommended level with SAE 10W30 engine oil.
  14. Electric Start Power ON Key Switch. To turn engine on, first turn key to ON, make sure low oil warning light does not come on, turn key further and hold until engine starts and release. Move switch to Off position to stop generator.
  15. Transport Pivot Handle.
  16. AC 120V Twist lock outlet. This NEMA L5-30 twist lock outlet allows 120V operation only, see instructions further in this manual.
  17. 30 Amp Reset. Resets the corresponding 120V AC NEMA L5-30 twist lock outlet.
  18. 1 of 2 Duplex AC 120V outlets. See #4 above.
  19. 30 Amp Reset. Resets the corresponding 120/240V AC NEMA L14-30 twist lock outlet.
  20. Recoil starter. Starts the engine.
  21. Air cleaner element/cover. Periodically the air cleaner filter must be checked and maintained, see maintenance section.
  22. Carburetor throttle lever (choke). Once the engine is started, it is necessary to gradually push in the carburetor throttle lever to the “OPEN” position, see instructions futher in this manual.
  23. Fuel Shut-off Valve. Regulates the flow of fuel to the engine. The fuel shut-off valve must be fully opened before starting the engine.
  24. 12V Battery. Powers the electric start.

Product Specification

  • MODEL KCG-7501GE
  • Peak Wattage (starting) 7500W
  • Running Wattage 5500W
  • AC current (120V/240V) 46Amp/23Amp
  • Engine (OHV) 13 HP
  • No load speed 3,600 RPM
  • Displacement (cc) 389
  • Fuel Unleaded Gasoline
  • Fuel tank (L) 25
  • Oil capacity (L) 1.1
  • Run time 7-8 hrs.
  • Noise level 74 dB(A)
  • Dimensions (LxWxH) 29-1/2” x 29” x 27”
  • Weight 214 lbs

ASSEMBLY & PRE-START CHECK

WARNING! To prevent permanent damage to generator or any appliances, you MUST check oil level, fuel level, air cleaner filter and unplug any load from the generator before starting.

ASSEMBLY

Remove all the contents from the carton and proceed to the following assembly steps;

Pivot handles
Install the pivot handles (A) Fig.1A to the left side of the frame using 2 hex. bolts and hex. nuts.

Wheels and Frame Supports
To install the wheels (B) Fig.1A to the right end of the frame, install the wheel shafts to the front and back of the frame first and secure them in place using hex. nuts. Slide each wheel onto the wheel shafts and secure the wheels by inserting a cotter pin (C) into the end of the wheel shafts, then seperate and bend the cotter pin outwards. Now that the wheels are installed, the last assembly step is to install the frame supports (D) to the frame using hex. bolts and hex. nuts.

Battery
To install the battery (E) Fig.1A, place the battery into the battery tray and secure it in place using the retaining plate (F). Once the battery is secure, connect the red positive (+) battery cable (G) to the positive post. Then connect the black negative (-) battery cable (H) to the negative post of the battery.
Note: Actual battery may appear different than the one shown in Fig.1A, but the installation instructions remain the same, always connect the red positive (+) battery cable to the positive post, connect the black negative (-) battery cable to the negative post of the battery.

PRE-START CHECK

OIL LEVEL
WARNING! This generator has been shipped from the factory without oil or very
little oil in the crankcase. Operating the unit without the correct amount of oil can damage the engine. Oil crankcase capacity: 1.1 litres.

Always check the oil level before starting the generator, make sure the genarator is on a level surface. To check oil level;

  1. Turn the oil gauge dipstick (A) Fig.1B counterclockwise, remove it and clean it with a clean cloth.

  2. Fully reinsert the oil gauge dipstick and pull it out to check the oil level.

  3. If the oil level is halfway up the dipstick or below, refill with SAE 10W30 oil through the dipstick hole until the oil level reaches 3/4 up the dipstick or until it reaches the bottom lip of the dipstick hole as shown in illustration below.

  4. Reposition the oil gauge dipstick and tighten it by turning clockwise.

FUEL LEVEL
WARNING! Make sure there is enough fuel in the fuel tank before operating.

  1. Check the fuel level indicator window (A) Fig.2, if the orange float gauge is all the way up, it is not necessary to add fuel. If you do not see or hardly see the orange float gauge, it is necessary to add fuel.
  2. If it is necessary to add fuel, first make sure the engine is OFF, then open the fuel cap (B) Fig.2 by turning it counterclockwise.
  3. Make sure the fuel filter cup (C) is positioned inside the tank opening before refueling.
  4. When refueling, keep in mind all safety precautions and make sure to add enough fuel based on usage. A full tank will give you 7-8 hours of operation. Use clean unleaded gasoline with a minimum of 87 octane. Do not mix oil with gasoline. Fuel tank capacity: 25 Litres.

PRE-START CHECK & STARTING PROCEDURES

PRE-START CHECK

AIR CLEANER FILTERS
The air cleaner filters should be checked before every start-up and after prolonged storage, the following steps should be done when checking air cleaner filters;

  1. Snap the top and bottom clips (A) Fig.3 backwards and remove the air cleaner cover (B).
  2. Remove the air cleaner filters (C & D), wash filters in kerosene, squeeze kerosene out, soak filters in engine oil and squeeze engine oil out.
  3. Replace filters and replace the air cleaner filter cover.
STARTING PROCEDURES

GROUNDING
WARNING! BEFORE STARTING, YOUR GENERATOR MUST BE GROUNDED!
Before operating make sure to ground the generator. A ground terminal identified by the ground symbol (Fig.4) can be found on the front control panel of the generator, attach a metal spike to a wire, attach the wire to the ground terminal and ground the metal spike into the earth. Your local electrical company or certified electrician should be able to help you with this information. See Fig.4.

STARTING YOUR GENERATOR
WARNING! Do not adjust or attempt maintenance of engine without consulting an authorized service center. Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas! Make sure all electrical appliances are unplugged before attempting to start generator!
To safely start your generator, follow the steps 1 through 8 in Fig.5 below.

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-13

Note: No choke is required on warm engines. Pull the recoil starter handle until resistance is felt, then pull it out with a rapid full arm stroke. Let the starter rope rewind slowly, repeat if necessary. Allow generator to run at no load for 5 minutes upon each initial start-up to allow engine and generator to stabilize. IF ENGINE OIL LEVEL IS TOO LOW, ENGINE WILL NOT START. CHECK OIL LEVEL AND ADD IF NECESSARY.

STOPPING PROCEDURES & ELECTRICAL CONNECTIONS

STOPPING YOUR GENERATOR
Make sure all electrical appliances are unplugged before stopping the generator!

  1. Turn breaker (B) Fig.6 “OFF” by lowering it.
  2. Turn the key in the engine power switch (A) to the “OFF” position by turning the key counterclockwise.
  3. Close the fuel shut-off valve (C) by bringing it upwards.

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-14

ELECTRICAL CONNECTIONS

CONNECTING ELECTRICAL LOADS
Attempting to connect generator directly to the electrical system of any building structure. Back feeding electricity through a building’s electrical system to the outside utility feed lines could endanger repair persons attempting to restore service. Failure to use a double throw transfer switch when connecting to a structure’s electrical system can damage appliances and WILL VOID the manufacturer’s warranty. Never backfeed electricity through a structure’s electrical system. To connect to a structure’s electrical system in a safe manner, always have a Double-Throw Transfer Switch installed by a qualified electrician and in compliance with local ordinances. (When installing a Double-Throw Transfer Switch, a minimum of 10 gauge wiring must be used).

IMPROPER CONNECTION OF ITEMS TO GENERATOR
Exceeding the load capacity of the generator by attaching too many items, or items with very high load ratings to it could result in overheating of some items or their attachment wiring resulting in fire or electrical shock. Make sure that the sum total of electrical loads for all attachments does not exceed the load rating of the generator.

WARNING! Failure to connect and operate equipment in the sequence below can cause damage to equipment and will void the warranty.

  1. Let engine run and warm up for five minutes after starting with no electrical load. Connect loads in the following manner:
  2. Connect “inductive” load equipment first, inductive loads consist of refrigerators, freezers, water pumps, air conditioners, or small hand tools. Connect the items that require the most wattage first.
  3. Connect the lights next.
  4. Voltage sensitive equipment should be the last equipment connected to the generator. Plug voltage sensitive appliances such as TV’s, VCR’s, microwaves, ovens, computers, and cordless telephones into a UL/CSA listed voltage surge protector, then connect the UL/CSA listed voltage surge protector to the generator.
    Overloading the generator will cause power fluctuations and can damage equipment and appliances. King Canada will not be responsible for equipment damaged as a result of voltage surges, improper operation or improper installation of the generator.
CONTROL PANEL

120V AC DUPLEX RECEPTACLES & RESETS
For normal 120V operation, plug your appliance or power bar into one of the two duplex 120V receptacles (A & C) Fig.7. Each receptacle has its own reset button (B & D) placed directly above.

120V AC TWIST LOCK RECEPTACLE (NEMA L5-30)
This twist lock receptacle (E) Fig.7 is a NEMA L5-30 twist lock receptacle and requires a NEMA L5-30 plug to make the connection. If you are unsure about the use of this twist lock receptacle or how to wire the appropriate plug, contact a qualified electrician for more information. This receptacle has its own reset button (F) placed directly above.

DUAL 120V/240V AC TWIST LOCK RECEPTACLE
This twist lock receptacle is equipped with a neutral to split the 240V into 2-120V. This 120/240V twist lock receptacle (G) is a NEMA L14-30 twist lock receptacle and requires a NEMA L14-30 plug to make the connection. If you are unsure about the use of this twist lock receptacle or how to wire the supplied plug, contact a qualified electrician for more information. This receptacle has its own reset button (H) placed directly above.

RESETS AND CIRCUIT BREAKER
The control panel contains 4 reset buttons (20 amp resets (B & D) for the duplex 120V receptacles, 30 amp resets (F & H) for the twist lock receptacles) and a main circuit breaker (I). If an overload occurs (reached maximum capacity), the corresponding reset button and the circuit breaker will “trip” to their “Off” position, causing the generator to automatically shut off. Disconnect all electrical items from the control panel. Press the tripped reset button, then position the circuit breaker to the On position and restart the generator. If the reset and circuit breaker continues to “trip”, the electrical item or items are exceeding the amperage capacity of this generator, reduce electrical charge or use a more powerful generator.

WATTAGE CALCULATIONS

WATTAGE CALCULATIONS
IMPORTANT! Never exceed the rated capacity of your generator. Serious damage to the generator or appliance could result from an overload.

  1. “Starting” and “Running” wattage requirements should always be calculated when matching a generators wattage capacity to the appliance or tool.
  2. There are two types of electrical appliances that can be powered by your generator;
    • Items such as radios, light bulbs, televison sets, and microwaves have a “resistive load”. Starting wattage and running wattage are the same.
    • Items such as refrigerators, air compressors, washer, dryer and hand tools that use an electrical motor have an “inductive load”. Inductive load appliances and tools require approx. 2 to 3 times the listed wattage for “starting” the equipment. This initial load only lasts for a few seconds on start-up but is important when figuring your total wattage to be used.
      Always start your largest electric motor first, and then plug in other items, one at a time.
      NOTE: On 120-volt loads the maximum starting wattage should NOT exceed one half of the rated generator wattage.
      Example: a 7500 rated wattage generator = 5500 maximum starting wattage.
      Wattage Requirement Chart below- This is only a guideline, each appliance or electrical device needs to be checked for its specific operating load.

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-16

DETERMINING WATTAGE REQUIREMENTS
Note: Volts X Amps = Watts
Example: 120V X 10 Amps = 1200 Watts
Before operating this generator, list all of the appliances and/or tools that are going to operate at the same time. (Then determine the starting wattage requirements and the running wattage requirements by following the example below;

  1. Add the total amount of the running wattage of all appliances and/or tools that will be operated at the same time.
    Example 1A:

    • Lights = 100 Watts (Running)
    • Television = 300 Watts (Running)
    • Coffee maker = 1750 Watts (Running)
    • TOTAL = 2150 Watts (Running)
  2. Next add the total amount of the starting wattage of any appliances and/or tools that will start and stop during operation.
    Example 1B:

    • Small Refrigerator = 700 Watts (Running) 2200 Watts (Starting)
    • Fan = 200 Watts (Running) 600 Watts (Starting)
    • TOTAL = 900 Watts (Running) 2800 Watts (Starting)
  3. The running wattage of examples 1A & 1B totals 3050 watts. The starting wattage totals 2800 watts which is 1900 watts more than the running watts. Take this difference of 1900 starting watts and add to the total running watts of 3050. Therefore:
    1900 Starting Watts + 3050 Running Watts = 4950 Total Watts The generator required to operate the items in example 1A & 1B must have a minimum capacity of at least 4950 starting watts.

MAINTENANCE & STORAGE

MAINTAINING YOUR GENERATOR

Engine Oil Replacement
Engine oil should be replaced after the first 20 hours of operation or after the first month of use, it should be replaced every 100 hours or 6 months after. To replace engine oil;

  1. Loosen the oil gauge dipstick (A) Fig.8.

  2. Place an oil pan underneath drain hex. bolt (B), remove hex. bolt (B) and drain oil.

  3. Once all the oil has completely drained, retighten the hex. bolt (B).
    Recommended Engine Oil
    It is recommended to use SAE 10W30 4-stroke gasoline engine oil. For cold weather (below -15ºC) use SAE 5W30.

  4. Fill with clean engine oil through the oil gauge dipstick hole, fill then check oil level until the oil level reaches 3/4 up the dipstick or until it reaches the bottom lip of the dipstick hole.

Inspecting, Replacing or Cleaning Spark Plug (F7TC or equivalent)
The spark plug should be checked every 100 hours of operation or every 6 months. To replace or clean spark plug;

  1. Dismantle the spark plug cap (A) Fig.9 by pulling it off the spark plug (B). Using the supplied spark plug wrench, undo the spark plug by turning it counterclockwise.
  2. Check to see if there is carbon sediment build-up, if so just remove it. If the carbon sediment is excessive, replace the spark plug.
  3. Measure the electrodes clearance. See Fig.10. The spark plug electrode clearance should be between 0.7-0.8mm. If the clearance exceeds 0.8mm, replace the spark plug with an LD F7TC or equivalent (NGK BP6ES, Champion N9Y).
  4. Reinstall spark plug in the reverse order.

Fuel Filter Maintenance
In order to clean the fuel filter inside the fuel cock, it is necessary to drain all gasoline from the tank and the carburetor, see section “Generator Storage” below for complete instructions.

  1. Once the tank and carburetor are drained of all gasoline, disconnect the fuel hose (A) Fig.11 from the fuel cock and then dismantle the fuel cock nut (B) from the tank.
  2. Remove the fuel cock from the tank to expose the fuel filter (C). Clean the fuel filter.
  3. Reinstall all parts in the reverse order.

GENERATOR STORAGE
If you plan on storing your generator for an extended period of time, the following steps should be followed;

  1. Add fuel stabilizer to fuel tank to minimize the formation of fuel gum deposits during storage.
  2. Run engine at least 5 minutes after adding stabilizer to allow it to enter the fuel system. NOTE: If a fuel stabilizer is not used, all gasoline must be drained from the tank and carburetor to prevent gum deposits from forming on these parts and causing possible malfunction of the engine. To drain gasoline;
  3. Turn fuel shut-off valve (A) Fig.12 to the “OFF” position.
  4. Disconnect the fuel hose (B) from the fuel cock.
  5. Turn fuel shut-off valve to the “ON” position and drain fuel from tank. Pivot the fuel cock outwards to simplify the task as shown in Fig.12.
  6. Remove drain hex. bolt (D) from the carburetor (C) and drain the rest of the fuel found inside the carburetor and hose.
  7. Reposition the carburetor drain hex. bolt and fuel cock hose once the fuel is complete-ly drained.
  8. Drain engine oil from engine as described in “Engine Oil Replacement”.
  9. Pull the recoil starter handle gently until resistance is felt.

TROUBLESHOOTING

KING-CANADA-KCG-7501GE-7500W-Gasoline-Generator-FIG-21

PARTS DIAGRAM & PARTS LISTS
Refer to the Parts section of the King Canada web site for the most updated parts diagram and parts list.