LUX PSP511A Smart Temp Electronic Thermostat Instruction Manual
- June 16, 2024
- LUX
Table of Contents
- LUX PSP511A Smart Temp Electronic Thermostat
- Product Information
- COMPATIBILITY
- FEATURES
- INSTALLATION
- OPERATING INSTRUCTIONS
- PROGRAMMING
- ADVANCED FEATURES
- SETUP OPTIONS
- BATTERIES AND MAINTENANCE
- TECHNICAL ASSISTANCE
- WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
- 1 Phillips screwdriver (small)
- 1 Phillips screwdriver (small)
LUX PSP511A Smart Temp Electronic Thermostat
Product Information
Specifications
- Model: PSP511A / PSP511LA SERIES
- Manufacturer: LUX PRODUCTS CORPORATION
- Location: Mt. Laurel, New Jersey, USA
- Compatibility: Can be used with most single-stage 24-volt gas, oil or electric heating and air conditioning systems, single-stage heat pumps, or gas millivolt heating systems. Cannot be used with 3-wire zone valves, 120-volt heating systems, or multi-stage heat pumps.
- Features:
- Backlit Display (PSP511LA only)
- Easy Programming
- Programmable Weekday and Weekend Programs
- Temperature Hold and Override
- Fan Auto/On
- Heat/Cool Mode Switch
- Fahrenheit/Celsius Temperature Display
- 12/24 Hour Clock Display
- Adjustable Temperature Differential / Cycle Rate
- 5/2 minute selectable minimum Run/Off time for short cycle and compressor protection
- System or Battery Powered
- Illuminated Display (PSP511LA only)
Installation Instructions
Please read all instructions carefully before beginning installation.
Compatibility
The PSP511A/PSP511LA can be used with most single-stage 24-volt gas, oil or
electric heating and air conditioning systems, single-stage heat pumps, or gas
millivolt heating systems. It cannot be used with 3-wire zone valves, 120-volt
heating systems, or multi-stage heat pumps. Please consult your dealer for
other LUX thermostats suitable for controlling those systems.
Caution
The PSP511A/PSP511LA is protected against normal static electric discharges.
To minimize the risk of damaging the unit in extremely dry weather, touch a
grounded metal object before touching your thermostat.
Installation
- Turn off the electricity to the appliance before installing or servicing the thermostat or any part of the system. Do not turn the electricity back on until work is completed.
- Do not short (jumper) across electric terminals on the furnace or air conditioner to test the system. This may damage the thermostat and void your warranty.
- All wiring must conform to local codes and ordinances. The thermostat should be limited to a maximum of 1.5 amps; a higher current may cause damage to the thermostat.
- Your thermostat is a precision instrument. Please handle it with care.
Tools Required
-
1 Phillips screwdriver (small)
- Drill with 3/16-in. (4.8mm) bit
- Wire stripper/cutter
Thermostat Location
On replacement installations, mount the new thermostat in place of the old one
unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below:
- Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often.
- Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall.
- Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window.
- Do not locate in a damp area. This can lead to corrosion that may shorten thermostat life.
FAQ
-
Q: What systems are compatible with the PSP511A/PSP511LA?
A: The thermostat is compatible with most single-stage 24-volt gas, oil or electric heating and air conditioning systems, single-stage heat pumps, or gas millivolt heating systems. It cannot be used with 3-wire zone valves, 120-volt heating systems, or multi-stage heat pumps. Please consult your dealer for other LUX thermostats suitable for controlling those systems. -
Q: Can the PSP511A/PSP511LA be used with battery power?
A: Yes, the thermostat can be powered by either the system or batteries. -
Q: Does the PSP511LA have a backlit display?
A: Yes, the PSP511LA model features a backlit display. -
Q: How do I override the programmed temperature?
A: To temporarily override the programmed temperature, use the Temperature Hold function. -
Q: How do I adjust the temperature differential or cycle rate?
A: The temperature differential or cycle rate can be adjusted using the appropriate settings on the thermostat. -
Q: What should I do if the thermostat is not functioning properly?
A: If you are experiencing issues with the thermostat, please refer to the troubleshooting section of the user manual or contact customer support for assistance.
SMART TEMP® ELECTRONIC THERMOSTAT
WARNING:
Use Energizer® or DURACELL® Alkaline Batteries Only. Energizer® is a
registered trademark of Eveready Battery Company, Inc. DURACELL® is a
registered trademark of The Gillette Company, Inc.
IMPORTANT!
Please read all instructions carefully before beginning installation. Save
them for future reference. Before removing any wiring from your existing
thermostat, its wires must be labelled with their terminal designations.
Ignore the colour of the wires since they may not comply with any standard.
Thank you for your confidence in our product. To obtain the best results from your investment, please read these instructions and acquaint yourself with your purchase before installing your new thermostat. Then follow the installation pro-cedures, one step at a time. This will save you time and minimize the chance of damaging the thermostat and the systems it controls. These instructions may contain information beyond that required for your particular installation. Please save for future reference.
COMPATIBILITY
The PSP511A/PSP511LA can be used with most single-stage 24-volt gas, oil or electric heating and air conditioning systems, single-stage heat pumps, or gas millivolt heating systems. It cannot be used with 3-wire zone valves, 120-volt heating systems, or multi-stage heat pumps. Ask your dealer for other LUX thermostats to control those systems.
FEATURES
- Heating and Cooling
- Contractor Grade
- Armchair Programmable
- One Year Warranty
- On Screen Low Battery Indicator
- Default Energy Star® Approved Programs
- Attractive design
- Exclusive LUX Speed Dial®
- 5/2 Programming
- Energy Star Compliant
- 4 Periods Per Day
- Battery Free Memory For All Programs And Settings
- Temporary Temperature Override
- Temperature Hold
- F/C Temperature Display
- 12/24 Hr Clock Display
- Adjustable Temperature Differential / Cycle Rate
- 5/2 minute selectable minimum Run/Off time provides short cycle and compressor protection
- System or Battery Powered
- Illuminated Display (PSP511LA only)
CAUTION
The PSP511A/PSP511LA is protected against normal static electric discharges.
To minimize the risk of damaging the unit in extremely dry weather, touch a
grounded metal object before touching your thermostat.
INSTALLATION
Please read all instructions carefully before beginning installation.
CAUTION
Turn off the electricity to the appliance before installing or servicing the
thermostat or any part of the system. Do not turn the electricity back on
until work is completed.
- Do not short (jumper) across electric terminals on the furnace or air conditioner to test the system. This may damage the thermostat and void your warranty.
- All wiring must conform to local codes and ordinances.
- The thermostat should be limited to a maximum of 1.5 amps; a higher current may cause damage to the thermostat.
- Your thermostat is a precision instrument. Please handle it with care.
TOOLS REQUIRED
-
1 Phillips screwdriver (small)
- Drill with 3/16-in. (4.8mm) bit
- Wire stripper/cutter
THERMOSTAT LOCATION
On replacement installations, mount the new thermostat in place of the old one
unless the conditions listed below suggest otherwise. On new installations,
follow the guidelines listed below.
- Locate the thermostat on an inside wall, about 5 ft. (1.5m) above the floor, and in a room that is used often.
- Do not install it where there are unusual heating conditions, such as: in direct sunlight; near a lamp, television, radiator, register, or fireplace; near hot water pipes in a wall; near a stove on the other side of a wall.
- Do not locate in unusual cooling conditions, such as: on a wall separating an unheated room; or in a draft from a stairwell, door, or window.
- Do not locate in a damp area. This can lead to corrosion that may shorten thermostat life.
- Do not locate where air circulation is poor, such as: in a corner an alcove; or behind an open door.
- Do not install the unit until all construction work and painting has been completed.
CAUTION
- Read the instructions carefully before removing any wiring from the existing thermostat.
- Wires must be labelled before they are removed.
- Do not allow wires to touch each other or parts on the thermostat.
- When removing wires from their terminals, ignore the colour of the wires since they may not comply with any standard.
REMOVING THE OLD THERMOSTAT
-
Switch electricity to the furnace and air conditioner OFF; then proceed with the following steps.
-
Remove the cover from the old thermostat. Most are snap-on types and simply pull off. Some have locking screws on the side. These must be loosened.
-
Note the letters printed near the terminals. Attach labels (enclosed) to each wire for identification. Remove and label wires one at a time. Make sure the wires do not fall back inside the wall.
-
Loosen all screws on the old thermostat and remove it from the wall.
MOUNTING THE PSP511A/PSP511LA -
Strip insulation leaving 3/8 in. (9.5mm) bare wire ends and clean off any corrosion.
-
Fill wall openings with non-combustible insulation to prevent drafts from affecting the thermostat. CAUTION
Be careful not to drop the unit or disturb electronic parts. Leave the door closed while the body is being removed from the base. -
Remove the body from the thermostat’s base by pressing the thumb latch at the bottom centre of the unit and swinging the body away.
NOTE
If you are mounting the base to soft material like plasterboard or if you are using the old mounting holes, the screws may not hold. Drill a 3/16 in. (4.8mm) hole at each screw, and insert the plastic anchors provided. -
Hold the base against the wall. Route the wires through the hole below the terminal block. Position the base for best appearance (to hide any marks from an old thermostat). Attach the base to the wall with the two screws provided.
CONNECTING THE WIRES -
Loosen wire clamp screws just enough to slide wire under the top black part of the clamp.
-
Using your label, and diagrams below determine appropriate wiring for your system.
-
If you are unsure or need assistance, call the LUX Technical Assistance Dept.(see TECHNICAL ASSISTANCE).
-
Slide proper wire between the brass back and black top clamp.
-
Tighten each screw securely.
- Dashed lines are optional.
- An optional common wire allows the system to power the thermostat.
- If “Y” and “C” are both present, then “C” is a common wire.
- If a “B” wire in your system is a common wire then connecting it to the B terminal may cause damage to your system.
- Use “B” or “O” in heat pump systems. Generally, neither is required in a conventional system.
These diagrams are provided for new installations or unreferenced wires.
- Dashed lines are optional.
- Optional common wire allows the system to power the thermostat.
- If “Y” and “C” are both present, then “C” is a common wire.
- If a “B” wire in your system is a common wire then connecting it to the B terminal may cause damage to your system.
- Use “B” or “O” in heat pump systems. Generally, neither is required in a conventional system.
COMPLETING YOUR INSTALLATION
-
See Setup Options to configure jumpers.
-
Install two new Energizer or DURACELL “AA” size alkaline batteries at this time. For instructions, see BATTERIES/MAINTENANCE.
NOTE
Remove the sticker from the display. -
Install your PSP511A/PSP511LA on its base. To do this hang the top of the unit by the tabs on the base, then snap the bottom of the unit into place. Do not use unnecessary force. If the body does not snap into place easily, remove the body, re-hang it from the tabs and try again.
-
Turn the power back on to your heating and/or air conditioning system.
-
Verify that the system and its fan are operating properly. When set to a high temperature, the heating system should provide warm air after a short time. Likewise, a cooling system should provide cool air after a short time. Usually sound from the furnace and air conditioning units can be heard while they are running. The rush of moving air should be heard within a short time after either has been started.
-
Your installation is now complete.
NOTE
If you have an electric system and the blower does not operate after
installation, find the electric/gas heat jumper on the back of the body. Move
the jumper to the ELEC position. No reset is required.
OPERATING INSTRUCTIONS
-
The PSP511A/PSP511LA alternately displays the current time and the room temperature, and the day of the week. The current program period, MORN, DAY, EVE or NITE is indicated by an arrow at the left edge of the screen. Set temperatures are indicated in the right side of the display.
With batteries installed, you can make a program or setting changes with the thermostat body on the wall, or conveniently remove it from its base plate. -
TEMPERATURE CONTROL MODES:
The Mode switch has three positions HEAT, OFF, and COOL. In the winter, set the system switch to HEAT to control your heating system. In the summer, set the switch to COOL to control your air conditioner. In spring and fall or when the windows are open, you can set the switch OFF. -
UP/DOWN/CHANGE KEYS:
UP/DOWN keys are just right of the unit’s display. They are used to adjust set temperatures and change other settings. -
CHANGING TEMPERATURE AND OTHER SETTINGS:
If there are many choices for a value, usually that setting will automatically advance by holding the Up or Down key. Some settings though, must be changed one press at a time. -
DISPLAY ILLUMINATION:
Press any key to illuminate (PSP511LA only) the display. Pressing any key will keep the display illuminated until no button has been pressed for approximately 20 seconds. -
FAN MODES:
The fan switch has two positions; AUTO will automatically run your system’s fan as required for heating and cooling only. ON runs your system’s fan continu-ously.
NOTE
The FAN switch works only if your system provides a wire for the
PSP511A/PSP511LA’s “G” terminal.
SETTING THE TIME AND DAY:
Open the door on the front of the thermostat. Rotate the dial to the SET
DAY/TIME position. You should see the display pictured below with a day of the
week flashing.
- Press UP to change the day of the week.
- Press NEXT to set the time; it will flash.
- Press UP or DOWN to change the time of day.
- When you are finished setting the day and time, rotate the dial to RUN to return to normal operation or to another position to continue programming.
HARDWARE RESET
This button will read option jumper positions before the unit begins normal
operation. It is located inside on the rear of the unit’s circuit board. It is
a small square component with a white button at it’s center. Pressing Hardware
Reset will allow the unit to read the new jumper settings without losing your
program.
SOFTWARE RESET
Use this front panel RESET to return all software settings and programs to
their default values. Option jumpers will be read and operation will
correspond to their current positions. To assist in reprogramming, copy your
programs into the chart provided before using SOFTWARE RESET.
PROGRAMMING CHART
DAY | PERIOD | HEAT | COOL |
---|---|---|---|
TIME | TEMP. | TIME | TEMP. |
MON. THRU FRI. | MORN | ||
DAY | |||
EVE | |||
NIGHT |
SAT.
and SUN.
| MORN| | | |
DAY| | | |
EVE| | | |
NIGHT| | | |
PROGRAMMING
The PSP511A/PSP511LA provides two separate programs, one for heating the other for cooling. Each program has separate settings for weekdays and weekends. Every day a program cycles through four independent periods. You can use the default programs or alter them to suit your schedule.
DEFAULT ENERGY STAR® TEMPERATURE PROGRAM
As supplied from the factory, the following ENERGY-approved program will be
used for temperature control in RUN mode. This program and all other software
settings may be restored to their default values via a SOFTWARE RESET.
PERIOD | HEAT MODE | COOL MODE |
---|---|---|
Morning | 6:00 AM 70 ° F (21 ° C) | 6:00 |
AM 78 ° F (26 ° C)
Day| 8:00 AM 62 ° F (17 ° C)| 8:00 AM
85 ° F (29 ° C)
Evening| 6:00 PM 70 ° F (21 ° C)| 6:00 PM
78 ° F (26 ° C)
Night| 10:00 PM 62 ° F (17 ° C)| 10:00
PM 82 ° F (28 ° C)
EDITING HEAT OR COOL PROGRAMS
You can review or change any preset times and/or temperatures to suit your
schedule for each day of the week. The four periods each day are
Morning(MORN), Day,(DAY) Evening(EVE), and Night(NITE).
WEEKDAY PROGRAMMING
- Select HEAT or COOL with the mode switch.
- Rotate the dial to SET WEEKDAY PROGRAMS. You will see the display shown here:
- All 5 weekday abbreviations will be displayed indicating that this program will cycle once each of these days,
- The HEAT or COOL set temperature will be displayed on the right side of the display. The start time for the displayed period will flash to show that this may be changed.
- Use the Up and Down keys. One period ends at the start time of the next period. The beginning of that period may not be any closer to the beginning of the next period than one 15-minute increment.
- Press NEXT to accept the displayed start time and advance to edit the SET TEMPERATURE.
- Use the UP and Down keys to change the flashing HEAT or COOL set temperature to the temperature you desire.
- Press NEXT to accept the displayed set temperature and advance to edit the start time for the next period. It will be flashing.
- Repeat for each of the four periods. When all the periods for the weekday program have been set, the start time for the morning will again be displayed flashing so that it may be edited.
- Rotate the dial back to RUN to accept all current values and end the weekday programming session.
WEEKEND PROGRAMMING
- To review or change the weekend program, select HEAT or COOL and rotate the dial to SET WEEKEND PROGRAMS. You will see a display similar to that shown here:
- Use steps 4 – 10 described in WEEKDAY PROGRAMMING to program on Saturday and Sunday.
TEMPERATURE OVERRIDE
OVERRIDE allows you to change the current SET TEMPERATURE in HEAT or COOL
until the next program period without changing your temperature control
programs.
- Press an arrow key once.
- While the Set Temperature is flash-ing; press an UP or DOWN key to adjust the set temperature by one degree in the associated direction.
- Holding the key will automatically advance the setting in the associated direction.
- The OVERRIDE will be canceled at the start of the next program period, and the temperature setting will return to its programmed value.
- An OVERRIDE may be terminated by rotating the dial, switching the mode to OFF, or initiating a HOLD.
- Adjusting the set temperature to its program value will also cancel an OVERRIDE.
TEMPERATURE HOLD
HOLD may be used for manual temperature control. HOLD is the simplest means to
set and maintain a fixed temperature. It allows you to set and maintain a
temperature Set Point indefinitely in Heat or Cool without concern for
programming. To initiate a HOLD:
- Press and release HOLD.
- After the Set Temperature begins to flash, adjust the temperature as desired with UP or DOWN keys.
- The temperature setting will not change until the HOLD is cancelled.
- To cancel a HOLD, press and release HOLD again, rotate the dial, or switch mode to OFF.
ADVANCED FEATURES
TEMPERATURE SWING
A thermostat works by turning your heating or cooling system on or off
whenever the room temperature varies from the set-point temperature. This
variation is the “swing.” Your system should cycle on about 3 to 6 times per
hour. A smaller swing number increases the number of cycles, so room
temperature is more constant. A larger swing number decreases the number of
cycles, but saves energy in most cases.
SWING SETTING
- With the Dial in its RUN position, simultaneously press NEXT & HOLD.
- Use the UP and DOWN keys to change the swing.
- Choices are 1 through 9. The default is 1.
- Rotate the dial to the RUN position or press NEXT to finish.
SETUP OPTIONS
-
JUMPER SETTINGS
There are three jumpers and one switch. Each controls a setting corresponding to its position. -
5MIN/2MIN MINIMUM RUN TIME – JP3
The position of J3 sets the minimum length of time that the thermostat must remain with Heat or Cool either on or off before it will automatically switch to the alternate On or Off state. This feature prevents short cycling and provides compressor protection for cooling units. Choices are 2 or 5 minutes. -
TEMPERATURE DISPLAY FORMAT °F/C – JP2
The position of this jumper controls whether the temperature is displayed in degrees F° or C° -
TIME DISPLAY FORMAT 12/24 HR CLOCK – JP1
The position of this jumper controls whether the time is displayed in a 12-hour or 24-hour Military Time format. -
REPOSITIONING JUMPERS
To change a setting, the jumper must be repositioned and a HARDWARE RESET must be performed. Note that as long as you press the Hardware Reset button (inside) and not the Software Reset button (front), you will change settings and not lose your program. These jumpers are located inside the thermostat on the rear of its circuit board. To access them, remove the unit from the wall by pressing up on the thumb latch at the bottom of the thermostat and swinging the body out and away. -
GAS/ELECTRIC SWITCH
This switch controls whether the thermostat requests the system fan to run when it is in HEAT mode with the fan set to AUTO. Then with the switch set to GAS, the fan is controlled by the heating system itself and the terminal will remain inactive. With the gas switch set to Electric (ELEC), the fan is controlled by the thermostat. The table pictured below is also printed on the circuit board. The closed or shorted position is that which covers both jumper pins. To prevent its loss in the open posi-tion, a jumper may be placed over one pin only. After jumpers have been changed, press the HARDWARE RESET button for the changes to take effect. See HARDWARE RESET
BATTERIES AND MAINTENANCE
WARNING
Use Energizer® or DURACELL® Alkaline Batteries Only.
INSTALLING BATTERIES/MAINTENANCE
When battery-powered, your PSP511A/PSP511LA requires battery replacement at
least once a year or when the battery “LO BATT” indicator is visible in the
display.
- Switch the electricity to the furnace and air conditioner OFF.
- To access your units batteries: Open the door.
- Using the groove at its top dead centre, remove the battery holder by rotating it outward from the top.
- Remove the used batteries from the rear.
- Install two new Energizer® or DURACELL® “AA” size ALKALINE batteries in the battery compartment. Observe the polarity marking shown in the compartment.
- Place the notches at the battery door’s bottom into the corresponding tabs inside the battery compartment
- Rotate the battery holder back into the thermostat body, snapping it into place.
- Turn the power back on to your heating and/or air conditioning system. If this is the first time you are installing batteries, the thermostat will display “SUN 12:00 AM”. Within 90 seconds the thermostat will begin to display the room temperature alternately with the time. To correct the display, see “Setting the TIME and DAY,” after you set the programs.
NOTE
When replacing batteries, you have approxi-mately 1 to 2 minutes before time
and day settings will be lost. All other settings will remain in memory.
With the batteries installed, this thermostat is “armchair programmable.” You can make any program or setting changes with the thermostat body off or on the wall thermostat base.
TECHNICAL ASSISTANCE
If you have any problems installing or using this thermostat, please reread the instruc-tions carefully or visit our online technical support at www.luxproproducts.com. Technical assistance is available through our Technical Service Number. If you require assistance, please call our office between 8:00 a.m. and 4:30 p.m. Eastern Standard Time, Monday through Friday. The number is 856-234-8803.
WARRANTY
Limited Warranty: If this unit fails because of defects in materials or workmanship within one year of the date of original purchase, LUX will, at its option, repair or replace it. This warranty does not cover damage by accident, misuse, or failure to follow installation instructions. Implied warranties are limited in duration to one year from the date of the original purchase. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Please return malfunctioning or defective units to the participating retailer from which the purchase was made along with proof of purchase. Please refer to “Technical Assistance” before returning your thermostat. Purchaser assumes all risks and liability for incidental and consequential damage resulting from the installation and use of this unit. Some states do not allow the exclusion of inci-dental or consequential damages, so the above exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state to state. Applicable in the U.S.A. only.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>