Mercedes-Benz A0009060407 Wallbox with Fixed Charging Cable Instruction Manual

June 16, 2024
Mercedes-Benz

A0009060407 Wallbox with Fixed Charging Cable

Mercedes-Benz Wallbox

Specifications

  • Mercedes-Benz product identification number: A0009060407,
    A0009060607

  • ABL model number: 3W11M1, 3W22M3

Product Information

The Mercedes-Benz Wallbox is a charging station for electric
vehicles. It is designed to provide a safe and efficient charging
experience for Mercedes-Benz electric vehicles.

About this Manual

This manual is included with the Mercedes-Benz Wallbox and
provides detailed instructions for installation, operation, and
troubleshooting. It is important to carefully read and follow all
safety notices and instructions in this manual.

Safety Notices

This manual contains important safety notices that must be
adhered to for safe operation of the wallbox. Please pay close
attention to these notices and follow all recommended safety
measures.

Product Usage Instructions

1. Introducing the Product

Before installing the wallbox, it is important to familiarize
yourself with the product. Unpack the wallbox and verify that all
components are included.

Unpacking and Components Included

When unpacking the wallbox, ensure that the following components
are included:

  • Wallbox unit
  • Mounting plate
  • Power supply cable
  • Installation manual

Identifying Your Model Variant

The model variant of the wallbox can be identified by the
product labels on the wallbox. These labels state the Mercedes-Benz
product identification number and the ABL model number. Make sure
that your model variant matches the one described in this
installation manual.

2. Installation Preparations

Prior to installation, it is important to ensure that the
installation site meets the general requirements specified in this
manual. Additionally, make sure that the power supply meets the
necessary requirements.

General Requirements of the Installation Site

The installation site should meet the following
requirements:

  • Accessible location
  • Proper ventilation
  • Adequate space for the wallbox unit and cables

Requirements for the Power Supply

The power supply should meet the following requirements:

  • Correct voltage and current capacity
  • Grounding according to local electrical codes

3. Mechanical Installation

The wallbox unit needs to be securely mounted on a mounting
plate. Follow the steps below for proper mechanical
installation:

Mechanical Installation of the Mounting Plate

  1. Choose a suitable location for the wallbox unit and mounting
    plate.

  2. Securely mount the mounting plate on the wall using appropriate
    screws and anchors.

  3. Attach the wallbox unit to the mounting plate using the
    provided screws.

4. Taking the Wallbox into Operation

After completing the mechanical installation, follow the steps
below to take the wallbox into operation:

Taking the Wallbox into Operation

  1. Connect the power supply cable to the wallbox unit and the
    power supply.

  2. Ensure that all connections are secure.

  3. Switch on the power supply.

  4. The wallbox is now ready for use.

5. Error Detection and Solutions

If you encounter any disruptions or error codes during the
operation of the wallbox, refer to the following sections for
solutions:

Disruptions to the Operation of the Wallbox and Solutions

If the wallbox is not functioning properly, follow these
steps:

  1. Check all connections and ensure they are secure.

  2. Reset the wallbox by switching off the power supply for a few
    seconds and then switching it back on.

  3. If the issue persists, refer to the error codes section for
    further troubleshooting.

Error Codes and Solutions

If an error code is displayed on the wallbox unit, refer to the
error codes section in this manual for a list of common error codes
and their solutions.

6. Taking the Product out of and back into Operation

If you need to temporarily disable or re-enable the wallbox,
follow these steps:

Taking the Product out of Operation

  1. Switch off the power supply.

Taking the Product back into Operation

  1. Switch on the power supply.
  2. The wallbox will resume normal operation.

7. Returning Your Wallbox

If you need to return your wallbox, follow the instructions
provided in this manual for proper packaging and shipping.

FAQ

Q: Can I install the wallbox myself?

A: It is recommended to hire a specialist electrical contractor
for the installation of the wallbox to ensure proper installation
and compliance with local electrical codes.

Q: Can the wallbox be used with non-Mercedes-Benz electric

vehicles?

A: The wallbox is specifically designed for use with
Mercedes-Benz electric vehicles. Compatibility with
non-Mercedes-Benz electric vehicles may vary.

Q: What should I do if the wallbox displays an error code?

A: Refer to the error codes section in the manual for a list of
common error codes and their solutions. If the issue persists,
contact your local Mercedes-Benz technical support.

Mercedes-Benz Wallbox
Installation manual for specialist electrical contractors

Search

Important addresses

Contact

Daimler AG Mercedesstraße 137 70327 Stuttgart, Germany

In case of technical questions, please contact your local Mercedes-Benz technical support.

This manual, in its entirety or in parts, must not be reproduced, stored electronically or otherwise transmitted electronically, electrically, mechanically, optically, chemically, by photocopy or as an audio recording without express written permission.

Version 1.1, MB-IM-Wallbox-2017-03-06 ii

Search

Article No. 0301482_c

Contents

Important addresses

ii

Important information

1

Preface

1

About this manual

1

Safety notices in this manual

1

Safety notices on the device

2

General safety information

2

General product information

3

Notes regarding installation

4

Preparations, installation and

taking into operation

5

Introducing the product

5

Unpacking and components

included

5

Identifying your model variant

5

General requirements of the

installation site

6

Requirements for the power supply 7

Mechanical installation of the

mounting plate

7

Taking the wallbox into operation 12

Error detection and solutions 13 Disruptions to the operation of

the wallbox and solutions

13

Error codes and solutions

13

Setup and testing modes

16

Taking the product out of and

back into operation

20

Returning your wallbox

20

Appendix

21

Technical specifications

21

Scale drawings and dimensions 22

Contact chart Type 1/Type 2

23

Guidelines & Norms

24

CE certification and declaration

of compliance

24

Glossary & Definitions

25

Trademarks

25

Intellectual Property & Copyright 25

Disposal advice

26

Mains Connection Schemes

27

Search

Mercedes-Benz Wallbox

iii

iv

Search

Important information

Preface

This manual describes the mechanical and electrical installation of the Mercedes-Benz Wallbox. The working steps described in this manual must only be carried out by qualified specialist personnel (mechanical installation) and qualified specialist electrical contractors (electrical installation), who, on the basis of their specialist training, knowledge and experience as well as their knowledge of the relevant regulations, can assess and carry out the working steps described in this installation manual and recognize potential hazards.

The model variants of the Mercedes-Benz Wallbox can be identified by the product labels on the wallbox. These labels state the Mercedes-Benz product identification number (exterior underside) as well as the ABL model number (interior electronic components cover), but are identical regarding technical specifications. Always make sure before installation that your model variant is the one described in this installation manual!

The following wallbox model variants are described in this manual:

Mercedes-Benz product identification number
A0009060407 A0009060607

ABL model number
3W11M1 3W22M3

About this manual
This manual is included with the Mercedes-Benz Wallbox and documents the steps and settings required for installing the wallbox, taking it into operation as well as for resolving malfunctions during operation. For quick and easy reference, certain sections of this manual are specially formatted.
· Descriptions listing equally valid options (as is the case here) are indicated by bullet points. · Descriptions that describe performing a function are shown in the form of numerical lists indicating the order of the indi-
vidual working steps. Please make sure you read this manual carefully and ensure in particular that you follow all safety notices given in this manual.
All measurements in this manual are in millimeters. Where necessary, the scale is indicated for different illustrations.
Please note that all technical details, specifications and design characteristics of the product may be changed without prior notice.

Safety notices in this manual
In particular, the warnings and safety measures in this manual that are marked as follows must be adhered to. The symbols carry the following meanings:
DANGER! Sections marked with this symbol draw attention to electrical voltages that represent a danger to life and limb: Actions contrary to these safety notices may lead to severe injury and death. Actions marked with this symbol must not be carried out under any circumstances.
CAUTION! Sections marked with this symbol draw attention to further hazards that may lead to damage to the wallbox itself or to other electric devices. Actions marked with this symbol must be carried out with special care.

Mercedes-Benz Wallbox | Important information

1

Search

PLEASE NOTE! Sections marked with this symbol draw attention to further important information and special features that are necessary for the reliable operation of the device. Actions marked with this symbol should be carried out as required.
Safety notices on the device
Further operational and safety notices are provided on the label on the right side of the housing and on the cover of the electronic components inside the wallbox. These symbols carry the following meanings:
WARNING! Please ensure that you first read the instruction manual included with the Mercedes-Benz Wallbox, especially before you open the housing cover of your wallbox.
WARNING! Please ensure that you first read the installation manual (this document) before you open the electronic components cover inside the wallbox.
DANGER! After opening the housing, dangerous voltages may be present on the inside of the wallbox as well as on components you are able to touch.
General safety information
Please pay attention to the following points: · Read this manual carefully. · Heed all warnings. · Follow all instructions. · The Mercedes-Benz Wallbox is available with a range of country-specific specifications. Please use the identification on the
name plate located on the underside of the wallbox to check whether the wallbox has been approved to be installed and operated in your country. · The wallbox must be installed, connected and approved for operation according to local rules and regulations by a qualified specialist electrical contractor. · The wallbox does not contain a residual current circuit breaker (RCCB). It must be installed in the upstream power supply and exclusive to the supply cable for the wallbox. All Mercedes-Benz Wallbox model variants described in this document have integrated DC fault current protection for which an RCCB with Type A tripping characteristic is generally sufficient. However, country- specific and local regulations must always be observed. These may prescribe an RCCB with a different tripping characteristic (e.g. Type B). · Please ensure that minimum clearances of 50 cm are kept on all sides of the wallbox during and after installation. · Only use accessories intended and sold for the device by Mercedes-Benz. · Do not operate this wallbox in close vicinity to running water or water jets: However, the Mercedes Benz Wallbox is sufficiently protected against water splashes and sprays according to IP54 (model variant A0009060407) or IP44 (model variant A0009060607). · The Mercedes-Benz Wallbox must not be installed in areas subject to flooding. · The Mercedes-Benz Wallbox must not be installed in explosive atmosphere areas (EX areas). · The Mercedes-Benz Wallbox must not be covered with stickers or other objects or materials so that sufficient air circulation is ensured at all times.
2

Search

· No liquids, or objects or receptacles containing liquids, must be placed on the housing.
· Please note that additional overvoltage protection may be required depending on the connected vehicle and/or by national regulations.
· Please note that, in some countries, a different tripping characteristic (e.g. Type B) for the upstream residual current circuit breaker (residual current device, in the following called RCCB, see also “Glossary & Definitions” on page 25) may be required.
· Please note that operating a radio transmitter in the immediate vicinity (< 20 cm) of the wallbox may lead to malfunctions and should therefore be avoided.
· This device is not intended to be used by persons with limited physical, sensory or mental abilities (including children) and/ or lacking knowledge, unless they are supervised by someone responsible for their safety or have received instructions from such a person on how to use the device.
· Children must be supervised so that they do not play with the device.
· Please note that the Mercedes-Benz Wallbox may be installed and operated at elevations of max. 2,000 meters AMSL (above mean sea level).
General product information
This Mercedes-Benz Wallbox represents the current state of technology and fulfills all current technical safety requirements, guidelines and standards. The safety notices in this manual serve to ensure the proper and safe installation as well as subsequent operation of the device. Disregard of or actions contrary to the safety information and instructions contained in this manual may lead to electric shock, fire, severe injury and/or death.
The Mercedes-Benz Wallbox must be installed by a qualified specialist electrical contractor, connected according to local regulations and norms and subsequently checked and approved for operation.
Malfunctions affecting the safety of persons, connected vehicles or the device itself must be repaired by an authorized specialist electrical contractor only.
Should a malfunction occur with your wallbox, please first read the sections regarding “Error detection and solutions” on page 13. Should the fault or malfunction recur and still not be able to be resolved, please contact your local Mercedes-Benz technical support.
Always contact Mercedes-Benz technical support if:
· the housing has been damaged mechanically,
· the housing cover has been removed or can no longer be closed or locked,
· sufficient protection against splashing water and/or foreign objects is obviously no longer evident,
· there is functional or visible damage to the charging socket or external charging cable
· or the wallbox does not function properly or has been otherwise damaged.
DANGER! Should you detect damage to the housing, charging socket or charging cable, you must immediately discontinue installation or take the already installed wallbox out of operation via the upstream miniature circuit breaker(s) (in the following called MCB(s), see also “Glossary & Definitions” on page 25) in your domestic power supply and the RCCB: No further use of the wallbox is permitted in this case! Please contact your local Mercedes-Benz technical support!

Mercedes-Benz Wallbox | Important information

3

Search

Notes regarding installation
Please observe the following instructions for the installation of your Mercedes-Benz Wallbox: · The device must always be connected to the protective earth conductor of your electricity supply. The protective earth con-
nection will be made and checked by the installing contractor. After installation, only specialist electrical contractors may make changes. · At all times comply with local safety regulations for the country in which you operate the wallbox. · For proper operation, the power supply for the wallbox must be protected in the domestic power supply with suitable MCB(s) and RCCB. · To disconnect the wallbox completely from the electricity grid, the power supply must be interrupted using the upstream MCB(s) and RCCB. · Ensure that the rated voltage and rated current of the device comply with the parameters of your local electricity grid and that the rated output is not exceeded during the charging procedure. · The wallbox should not be installed in areas of high pedestrian traffic. Installation along thoroughfares and marked escape routes should be especially avoided. · Never install the wallbox in a confined space. In particular, you must ensure that the vehicle can be parked at a suitable distance from the wallbox for charging and connected without any strain on the charging cable. The distance between vehicle and wallbox should be at least 50 cm and no more than 5 m. You may deviate from this recommendation depending on the model variant of the wallbox (length of charging cable) and local conditions. · You must not under any circumstances make any changes to the housing or the internal wiring of the wallbox: Any disregard of this instruction represents a safety risk, fundamentally breaches the guarantee provisions and may void the warranty with immediate effect.
4

Search

Preparations, installation and taking into operation

Introducing the product
The Mercedes-Benz Wallboxes are entirely manufactured in Germany and at all times comply with the regulations and norms for the charging of electric vehicles applicable throughout Europe according to IEC 61851-1, Mode 3 ­ please also refer to the section on”Guidelines & Norms” on page 24. According to their requirements, users may select from models with charging socket or fixed charging cable, which are designed for domestic and also for semi-public applications.
We place the highest value on user safety in all our products. To this end, your wallbox provides integrated DC fault current detection, ensuring the proper functioning of upstream RCCBs in case of DC fault currents.
The wallbox is especially easy to operate during everyday use: Three LED lights in the lower part of the housing cover allow you to check the current operating status at any time. Should a malfunction occur, you can identify the cause by its specific LED error code without having to open the housing. After being taken into operation by a specialist contractor, the MercedesBenz Wallbox is ready for charging at any time, while each charging process must be separately authorized via the integrated key switch.

Unpacking and components included

The Mercedes-Benz Wallbox package includes a range of accessory components needed for installation and proper operation. Therefore, please check immediately after unpacking (together with the customer, if required) whether the following components are included:

Component

Quantity Description

Wallbox

1

Charging station, consisting of plastic housing with lockable cover and separate mounting plate.

Quick start guide

1

Quick start guide including safety notices in printed form

Installation kit

1

Set of fixings for wall mounting, consisting of 2 x 4 screws as well as matching wall plugs, triangular key, key for the key switch (2 pcs), strain relief including screws (2 pcs), sealing grommets for openings at the back of the housing (3 pcs)

Should one or more of the components listed above be missing after unpacking, please contact your local Mercedes-Benz partner immediately.

Identifying your model variant
The Mercedes-Benz Wallbox is available in a range of model variants that are mechanically and electrically tailored to different application profiles.
An additional product label with the specific Mercedes-Benz product identification number for the wallbox is located on the underside of the wallbox. For identification, the model code (A000 906 XX XX) as well as the power supply ratings (voltage, frequency, current) indicated below it are especially relevant.

Mercedes-Benz Wallbox | Preparations, installation and taking into operation

5

Search

When you open the housing cover for installation, you will find behind it an additional product information label on the lower part of the electronic components cover, which will also carry the ABL model number.

3W22M300001

Using the Mercedes-Benz product identification number or the ABL model number, please always ensure before installation that your wallbox model variant is the one whose installation is described in this document. You can find a list of the wallbox model variants described in this manual and the correlations between Mercedes-Benz product identification numbers and ABL model numbers in the table below.

The following wallbox model variants are described in this manual:

Mercedes-Benz product ABL model number
identification number

A0009060407

3W11M1

A0009060607

3W22M3

Grid connection Model Variant

230 / 400 V 50 Hz 16 A 230 / 400 V 50 Hz 32 A

Fixed charging cable according to IEC 62196-2 Type 2, ca. 6 m; charging output 11 kW Integrated charging socket with shutter according to IEC 62196-2, Type 2 for separately available Mode 3 charging cable; charging output 22 kW

CAUTION!
The information and technical specifications contained in this manual relate exclusively to the model variants mentioned in this manual and must not be transferred to other wallbox models. These variants include specific instruction manuals where necessary. Should your wallbox model variant not be described in this manual, please contact your local Mercedes-Benz technical support: Do not under any circumstances install the wallbox in this case, as this could lead to damage to the wallbox, to injury and/or death.

General requirements of the installation site

Your Mercedes-Benz Wallbox is an electrical device and is therefore subject to particular requirements for indoor and outdoor installation. In selecting the installation site, you must consider the following points:

· Consider all local regulations for electrical installations, fire protection and accident prevention.

· The wallbox must be installed where it is freely accessible to all authorized users.

· A parking spot must also be planned for in front of the wallbox so that the vehicle can at all times be reached with the integrated or with an external charging cable.

· The recommended installation height is 120 to 140 cm from the floor to the lower edge of the housing. This recommendation may be adjusted upwards or downwards depending on local conditions. Sufficient air circulation must be ensured at the installation site so that the wallbox is cooled during operation: Always observe the allowed operating temperatures (see “Technical specifications” on page 21).
· The mounting area must have an even surface that provides sufficient stability for installing the wallbox.

120 to 140 cm

· The required mounting area for the Mercedes-Benz Wallbox is at least 512 x 429 mm (H x W). All of the mounting plate of the wallbox must be in contact with the mounting surface.

· To ensure the safe operation of the wallbox, minimum clearances of 50 cm must be kept on all sides of the housing.

6

Search

· In general, the Mercedes-Benz Wallbox is engineered for operation in high ambient temperatures. However, it must be ensured that the maximum operating temperature is not exceeded through external influences such as direct sunlight or similar.
· The wallbox meets the requirements for outdoor installation. Outdoors, the wallbox should only be installed in covered locations that provide sufficient protection from weather-related pollution.

Requirements for the power supply
The following standards must always be considered for the electrical installation of the Mercedes-Benz Wallbox:
· All regulatory requirements for low voltage installations according to IEC 60364-1 and IEC 60364-5-52 apply.
· Model variants A0009060407 and A0009060607 are intended for rated voltages of 230 V (phase-neutral) or 400 V (phasephase) at 50 Hz.
· The installation site must offer a sufficiently dimensioned power supply according to HD 60364-7-722:2012 (see also “Guidelines & Norms” on page 24): This power supply must be reserved exclusively for the wallbox and must not be used to supply other electrical devices.
· If necessary, a separate power supply must be installed that is intended exclusively for connecting the wallbox and complies with the general requirements for cabling and building infrastructure.
· Depending on the desired rated power, the installation of the wallbox may need to be registered with and/or approved by the local electricity grid operator. Please consult the local regulations of your electricity grid operator.
· Cable dimensions must be adjusted according to the desired rated power and other aspects (such as cable length, material, cabling method etc.). The terminal blocks in the wallbox are designed for cable dimensions of up to 16 mm2.
· The power supply cables may be installed above or below the wall surface: The mounting plate provides alternative cable inlets at the top and at the rear.
· The power supply for the wallbox must always be protected by its own MCB and RCCB (at least Type A): Please always observe current national regulations regarding the selection of MCB and RCCB. Depending on the country, an RCCB with a different tripping characteristic (e.g. Type B) may be prescribed.
· The wallbox does not have a dedicated ON/OFF switch: If you want to take the wallbox out of operation, you must always switch the upstream domestic MCB(s) and RCCB to the 0 (OFF) position.
· Please always ensure that the installation requirements listed in this manual are complied with. Disregard or actions to the contrary may lead to severe injury by electric shock or even death. In addition, in case of contravention of the notices given, the proper operation of the wallbox cannot be guaranteed.
PLEASE NOTE! In some countries, the above mentioned requirements are different from the prerequisites for connecting to the local power grid. In this case, the wallbox must be connected in accordance with the respective type of mains power connection for the country of installation. You can find an overview of country-specific mains connection schemes on page 27 in this manual or on the www.yourwallbox.de website using the following link: www.yourwallbox.de/Mains_Connection_Schemes

Mechanical installation of the mounting plate
After determining the mounting site for the wallbox, you can begin with mechanical installation. For installation you will need the following components: · Power drill or cordless drill (not included) · Drill bit Ø 10 mm, appropriate for the wall substrate (not included) · Screwdriver with flat head (2.5 mm blade width), Phillips head (PH1) and torx head (TX40, TX25, TX20, TX10) bits

Mercedes-Benz Wallbox | Preparations, installation and taking into operation

7

Search

· Mounting plate (included) · Pliers or cutter for breaking or cutting out the cable inlet in the mounting plate (not included) · Four 8 x 60 wafer head (TX40 bit) screws for fixing the mounting plate (included) · Four 6 x 25 (TX25 bit) screws for fixing the wallbox housing to the mounting plate (included) · If required: Wall plugs suitable for the mounting substrate (included: 10 x 50 nylon wall plugs) · Spirit level if required (not included)
DANGER! Always observe the 5 golden rules of electrical installation: 1. Cut off all voltage sources 2. Secure all cut-off devices 3. Verify absence of voltage 4. Ground and short-circuit 5. Cover or bar access to adjacent components under voltage Always deactivate the MCB(s) and RCCB allocated to the wallbox in the domestic power supply before you begin installation. Also ensure that the MCB(s) and RCCB cannot be reactivated during installation. Otherwise, there is a risk of severe injury through electric shock or even death!
Proceed as follows to drill the holes using the mounting plate: 1. Ensure that a sufficiently dimensioned power supply is available at the desired installation site. Otherwise, a power supply
must be installed especially.
83
2. The mounting plate has pre-molded cable inlets for the power supply on its upper edge as well in the middle of its surface. According to the power supply at the installation site (and as required), please remove one of the plastic tongues intended for the power supply cable with a suitable pair of pliers, a cutter or drill.
3. Place the mounting plate on the chosen mounting surface: Use a spirit level if required. Mark the drill holes.
8

Search

4. Drill the mounting holes as marked (Ø 10 mm). Insert the supplied wall plugs for the mounting screws if required.
5. Fix the mounting plate in position with a screwdriver (TX40 bit) and the wafer head screws (8 x 60) included. PLEASE NOTE: In case the power supply enters from the rear, you must first thread the cable through the opening in the connection area in the lower third of the mounting plate before screwing the plate into position.
6. For the cable to enter from the top, you must install the power supply such that it is inserted into the connection area from above and can be fixed using its allocated strain relief. PLEASE NOTE: The strain relief is not required if the power supply enters from the rear.
7. Now open the housing cover of the wallbox using the triangular key supplied and flip it towards the front. PLEASE NOTE: Take special care with this and protect the housing cover against scratching and other external damage. If possible, only remove the protective film from the housing cover just before completing installation.
8. Use the screwdriver to loosen the TX20 screw holding the internal electronic components cover in place and remove it. Keep the screw in a safe place.

Mercedes-Benz Wallbox | Preparations, installation and taking into operation

9

Search

9. The wallbox includes three custom sealing membranes for the openings in the lower part of the wallbox: Insert these and cut a slit into the large sealing membrane: Now insert the supply cable through this opening.
10. Hang the wallbox onto the mounting plate by inserting the screw in the centre of the upper part at the rear into the respective opening in the mounting plate: this already protects the wallbox from falling.
11. Now fix the wallbox to the mounting plate using the screwdriver (TX25 bit) and the four 6 x 25 screws included. The wallbox is now securely fastened to the mounting plate.
12. If using a power supply with flexible wires, ensure that the stripped ends are fitted with wire end ferrules. Loosen the lower screws in the terminal blocks, insert the wires into their respective terminal and tighten with a torque of 2.5 to 3 Nm. The wiring sequence is shown in the following diagram and table.

10

Search

The supply cable for the 3-phase model variants A0009060407 and A0009060607 is connected as follows:

Designation

Wire colors

Connection coding

Current-carrying conductor phase 1

Brown

L1

Current-carrying conductor phase 2

Black

L2

Current-carrying conductor phase 3

Gray

L3

Neutral

Blue

N

Protective earth

Green-Yellow

PE

DANGER!
Please note that the electronic components of your wallbox will be damaged if you apply a voltage above 250 V between the L1 current-carrying conductor and neutral.

PLEASE NOTE!
If desired, the 3-phase model variants can also be connected and operated on a single phase at terminal L1: However, in this case the rated output for the wallbox will not be achieved. In case of an unbalanced load on the supply grid, please observe the technical requirements for installation in force locally.

PLEASE NOTE!
In some countries, the requirements mentioned in this manual differ from the prerequisites for connecting to the local power grid. In this case, the wallbox must be connected in accordance with the respective type of mains power connection for the country of installation. You can find an overview of country-specific mains connection schemes on page 27 in this manual or on the www.yourwallbox.de website using the following link: www.yourwallbox.de/Mains_Connection_Schemes

PLEASE NOTE!
The Mercedes-Benz Wallbox is preset for a charging current of 16 A by the factory. Should your domestic power supply provide a lower or higher charging current, you must reset the preset current for the wallbox accordingly before you replace the electronic components cover and then take the wallbox into operation. This is described in detail in section “Setup and testing modes” on page 16 and following. Please note that the rated current indicated on the product label and configured in the firmware must under no circumstances be exceeded.

13. Replace the electronic components cover inside the housing and fix it with its torx screw (TX20 bit).

14. Flip the housing cover upwards so that it clicks into the housing and lock it with the triangular key supplied.

Mercedes-Benz Wallbox | Preparations, installation and taking into operation

11

Search

Taking the wallbox into operation

After mechanical and electrical installation, you must check the correct functioning of the Mercedes-Benz Wallbox for operation and resolve any malfunctions or installation errors that may have occurred.
Proceed as follows to take the Mercedes-Benz Wallbox into operation:
1. Switch on all upstream MCB(s). 2. In addition, switch on the external RCCB (connection of the wallbox to the electricity grid is established). When the wallbox is reconnected to the electricity grid, it will initiate the start-up procedure: This includes an internal test of the electronics to ensure correct functioning.
The internal check routine is indicated by the LEDs on the front of the Mercedes-Benz Wallbox as follows.

LED display

Description

All three LEDs flash once …

… and then go out.
Then, the blue LED (ancillary version) and the green LED (main version) flash to indicate the current version of the firmware (only relevant for error detection). On completion the blue LED flashes every 5 seconds, the green LED and the red LED go out. The vehicle can now be connected for charging. The charging procedure itself is described in the operating manual included.
PLEASE NOTE! To complete electrical installation, the protective devices of the wallbox must be checked in testing mode for correct functioning. Testing mode is described in section “Setup and testing modes” on page 16 and following.

12

Search

Error detection and solutions
Should a malfunction occur during operation of the Mercedes-Benz Wallbox, this is shown by the indicator LEDs on the lower part of the housing cover as an error code. To indicate certain operating states, the LEDs may…

… be illuminated (continuous ON)

… flash

… be extinguished (continuous OFF).

The following chapter describes how you recognize operating states as well as error codes and which measures you can take to resolve them.

Disruptions to the operation of the wallbox and solutions

For secure operation, the Mercedes-Benz Wallbox must be protected by external MCB(s) and RCCB in the domestic power supply. To take suitable measures and restore operation in case of malfunction, you must first clearly identify the type of error. The following errors may occur:

Type of error

Possible cause

Suggested solution

The wallbox does not have a power supply.

The power supply is interrupted within the domestic electrical infrastructure: Check the upstream MCB(s) and RCCB and switch them back on if required. If the error repeats or occurs permanently, contact your local Mercedes-Benz technical support.

LEDs are not functioning.

The wallbox has not been connected in accordance with the respective type of mains power connection for the country of installation.

Check your mains connection scheme using the overview of country-specific mains connection schemes on page 27 in this manual or on the www.yourwallbox.de website using the following link: www.yourwallbox.de/Mains_Connection_Schemes If necessary, please change your mains connection scheme according to this overview.

An internal fault has occurred in the wallbox.

The wallbox must be replaced. In this case, please always contact your local Mercedes-Benz technical support.

The electric vehicle is not recognized.

The charging cable is not properly plugged into the vehicle or the wallbox.

Remove the charging connectors from the vehicle and the wallbox and plug them back in: Should the error persist, check the Mode 3 charging cable and contact your local Mercedes-Benz technical support.

The indicator LEDs show an error message.

The Mercedes-Benz Wallbox detects a malfunction.

Please reinitiate the charging procedure: If the error repeats or occurs permanently, take the wallbox out of operation (see “Taking the product out of and back into operation” on page 20) and contact your local Mercedes-Benz technical support.

PLEASE NOTE!
Should the power supply be faulty, please take the wallbox out of operation (see “Taking the product out of and back into operation” on page 20) and contact your local Mercedes-Benz technical support.

Error codes and solutions
To represent certain errors, the indicator LEDs will illuminate and flash in a specific, repeating pattern. Error codes F1 to F10 are displayed at 200 ms intervals: LEDs may be illuminated or extinguished permanently, or may flash for 200 ms. You can find the correlations between visual display and errors in the following list:

Mercedes-Benz Wallbox | Error detection and solutions

13

Search

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The green LED flashes four times, the blue LED is OFF, the red LED is continuously ON.

Error F1: The main contactor of the wallbox does not open.

The green LED flashes three times, then the blue LED flashes once, the red LED is continuously ON.

Error F2: The firmware has detected a disallowed operating state during the initial or periodic self-test.

Solution: In both cases, switch the power supply off and then back on again. If the error continues to occur, take the wallbox out of operation (see “Taking the product out of and back into operation” on page 20) and contact your local MercedesBenz technical support.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The green and blue LEDs alternately flash twice each, the red LED is continuously ON.

Error F3: The internal DC fault current module has detected a DC fault current.

Solution: If the error occurs for the first time, the charging procedure is interrupted for 30 seconds and then restarted automatically. If the error occurs again immediately, the charging procedure is terminated: a new charging procedure is only possible after disconnecting the vehicle from the wallbox.

There is possibly an electrical fault in the charging system of the vehicle. Do not charge the vehicle and immediately contact a qualified specialist repairer. In addition, always consider the notices provided in the operating manual of the vehicle.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The blue LED flashes four times, the green LED is OFF, the red LED is continuously ON.

Error F5: This error is only relevant for model variants with charging socket (A0009060607) and indicates that the connector of the Mode 3 charging cable could not be locked inside the charging socket of the wallbox.

The green LED flashes twice, then the blue LED flashes twice, the red LED is continuously ON.

Error F6: This error is only relevant for model variants with charging socket (A0009060607) and indicates that the electrical current coding of the Mode 3 charging cable is faulty.

Solution: The wallbox automatically reinitiates the charging procedure every 60 seconds: Should the error continue to occur, check the position of the connector in the charging socket or unplug it and plug it back in. If the error continues to occur, check the Mode 3 charging cable itself. If the cable itself does not show signs of damage, the wallbox might have to be replaced: Please contact your local Mercedes-Benz technical support.

14

Search

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description
Error F7: The vehicle demands a charging procedure with ventilation.
The blue LED flashes twice, the green LED is OFF, the red LED is continuously ON. Solution: The wallbox automatically reinitiates the charging procedure every 60 seconds: If the error continued to occur, please contact your local Mercedes-Benz technical support. Charging vehicles that require ventilation during the charging procedure is not possible with the Mercedes-Benz Wallbox.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The green LED flashes twice, the blue LED is OFF, the red LED is continuously ON.

Error F8: A short circuit has been detected between the pilot contact CP and the protective earth PE or the communication interface of the vehicle is faulty.

Solution: The wallbox automatically reinitiates the charging procedure every 60 seconds: If the error continues to occur, check the Mode 3 charging cable. If the cable does not show signs of damage, the vehicle must be checked: Please contact a qualified specialist repairer.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The green LED flashes four times, every fourth time the blue LED also flashes, the red LED is continuously ON.

Error F9: The electrical current monitoring module has detected that the charging current is exceeding the preset maximum current.

Solution: The wallbox automatically reinitiates the charging procedure every 60 seconds: If the error continues to occur, the Mode 3 charging cable or the vehicle must be checked: Please contact a qualified specialist repairer.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The green LED flashes four times, the blue LED also flashes every third and fourth time and the red LED is continuously ON.

Error F10: The temperature monitor has detected a temperature above 80° Celsius inside the housing.

Solution: The temperature monitor interrupts the charging procedure.

· After 10 minutes, the charging procedure is automatically reinitiated if the temperature inside the housing has fallen to below 70° Celsius.

· The charging procedure is reinitiated immediately as soon as the temperature inside the housing falls to below 60° Celsius.

If the error repeats or persists, the wallbox must be cooled and/or shaded more effectively at the installation site. If the error continues to occur, the vehicle must be checked: Please contact a qualified specialist repairer.

Mercedes-Benz Wallbox | Error detection and solutions

15

Search

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The blue and the green LED are continuously ON, the red LED flashes twice.

Error F16: Data transfer to the integrated electrical current monitor is disrupted. The maximum charging current is limited to 10 A while this error occurs.

Solution: Charging operations can continue, but the charging output will be reduced. If the error repeats or occurs permanently, take the wallbox out of operation (see “Taking the product out of and back into operation” on page 20) and contact your local Mercedes-Benz technical support.

200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms 200 ms Description

The blue and the green LED are continuously ON, the red LED flashes twice.

Error F17: The temperature monitor has detected a temperature above 60° Celsius inside the housing. The maximum charging current will be limited to 6 A.

Solution: Charging operations can continue, but the charging output will be reduced. If the error repeats or persists, the wallbox must be cooled and/or shaded more effectively at the installation site. If the error continues to occur, the vehicle must be checked: Please contact a qualified specialist repairer.

CAUTION!
If the wallbox continues to or permanently displays error messages, take the wallbox out of operation (see “Taking the product out of and back into operation” on page 20) and contact your local Mercedes-Benz technical support. Repairs may have to be carried out before charging procedures can resume.

Setup and testing modes
If a lower or higher charging current is provided by the domestic power supply, the factory preset for the Mercedes-Benz Wallbox (16 A) can be altered in setup mode via the internal rotary encoders. However, the rated current indicated on the product label must not be exceeded under any circumstances.
Setup mode
To make adjustments via the rotary encoder, you must first remove the internal electronic components cover of the wallbox: This is described in steps 7 and 8 page 9 of section “Mechanical installation of the mounting plate”.
DANGER! After opening the cover for the electronic components, dangerous voltages may be present on the inside of the wallbox as well as on components you are able to touch. ALWAYS switch off the MCB(s) and RCCB for the wallbox in the domestic power supply first, and before you continue in setup or testing mode. Always observe the 5 golden rules of electrical installation:
1. Cut off all voltage sources 2. Secure all cut-off devices 3. Verify absence of voltage 4. Ground and short-circuit 5. Cover or prevent access to adjacent parts under voltage.
Otherwise there is a risk of severe injury or even death through electric shock!

16

Search

Two rotary encoders (S1 and S3) are located on the main circuit board of the Mercedes-Benz Wallbox. For normal operations, these must be set to the 0 position. Only the S1 encoder (located on the left hand side of the plan) is relevant for changing the maximum charging current. Always leave the S3 rotary encoder in the 0 position.

S1 S3

Please follow these steps to change the maximum charging current setting of your Mercedes-Benz Wallbox:

Working step
1. Switch off the power supply for the wallbox via the upstream MCB(s) and RCCB.
2. Remove the internal electronic components cover. Set the desired value using the S1 rotary encoder (see table on page 16).
3. Replace the internal electronic components cover. Close and lock the housing cover. Switch the power supply back on via the upstream MCB(s) and RCCB.

LED status

Note

On the S1 rotary encoder, select the position for the desired electrical current. Leave the S3 rotary encoder in the 0 position.
The wallbox will now restart in setup mode and register the settings of the two rotary encoders.

4. The wallbox now restarts in setup mode. ca. 10 minutes

If the settings have been successfully saved after approx. 10 seconds, all LEDs will be on.

5. Switch off the power supply via the upstream MCB(s) and RCCB.
6. Remove the internal electronic components cover. Set the S1 rotary encoder to the 0, 1 or F position.
7. Replace the internal electronic components cover. Close and lock the housing cover. Switch the power supply back on via the upstream MCB(s) and RCCB.


Ensure that the S3 rotary encoder remains set to the 0 position.
During start-up, the wallbox will load the new settings from the memory and then return to normal operating mode (see page 12 and following).

In some circumstances, an error may occur when changing the preset charging current, which will be indicated by the LED display after you have switched the power supply to the wallbox back on in step 3.

Error description · The settings could not be saved in the memory.

LED status

· The wallbox was set to an electrical current that is not allowed for this model variant: The preset current is therefore not altered.
In both cases, please continue with step 6 in order to then restart the wallbox for normal operations.

Mercedes-Benz Wallbox | Error detection and solutions

17

Search

Testing mode

During initial setup and during later operation, you can check the settings of the Mercedes-Benz Wallbox in testing mode if there is no vehicle available. To do so, proceed as follows:

Working step
1. Switch off the power supply for the wallbox via the upstream MCB(s) and RCCB.
2. Remove the internal electronic components cover. Set the S1 rotary encoder to the 2, 4 or E position (see table on the next page).
3. Replace the internal electronic components cover. Close and lock the housing cover. Switch the power supply back on via the upstream MCB(s) and RCCB.
4. The wallbox will now start up in testing mode.

LED status

Note Leave the S3 rotary encoder in the 0 position.

DANGER!
During testing mode, dangerous currents are applied to the charging contacts of the wallbox, which present a danger to life and limb: do not touch these contacts under any circumstances and proceed with the following actions using extreme caution. Otherwise, there is a risk of severe injury through electric shock or even death!

5. With the wallbox in testing mode, you can now measure the voltage at each phase of the charging socket (A0009060607) or the charging connector (A0009060407). Measuring the signal at the CP contact (against PE), the frequency, as well as the duty cycle are also possible.

ca. 10 minutes

6. To terminate testing mode, switch off the power supply of the wallbox via the upstream MCB(s) and RCCB.
7. Remove the internal electronic components cover. Set the S1 rotary encoder to the 0, 1 or F position.
8. Replace the internal electronic components cover. Close and lock the housing cover. Switch the power supply back on via the upstream MCB(s) and RCCB.

The flashing LEDs indicate that the wallbox is switched on and a voltage is applied to the charging contacts. Therefore proceed with extreme caution!
After approx. 10 minutes, the voltage is switched off automatically (all LEDs are illuminated).

Ensure that the S3 rotary encoder remains set to the 0 position.
During start-up, the wallbox will load the new settings from the memory and return to normal operating mode.

18

Search

Settings for the S1 and S3 rotary encoders

The following settings can be selected using the S1 rotary encoder on the left:

0

Normal operation

Setting for normal charging operations

1

no function

2

Testing mode

Measuring voltage (contactor closed) and communications (CP) possible at the charging contacts in order to test functionality without a vehicle

3

Setting device ID

Device ID input possible via S3 rotary encoder (see next page)

4

Testing mode

See position 2

5

8 A

6

10 A

7

13 A

8

16 A

9

Setting the maximum charging current 20 A

A

30 A

B

32 A

C

64 A

D

Return to factory setting (16 A)

E

Testing mode

See position 2

F

Normal operation

Setting for normal charging operations

The following settings can be selected using the S3 rotary encoder on the right:

Position MODBUS device ID

Explanation

0

Normal operation

Setting for normal and testing operations

1

0x01

2

0x02

3

0x03

4

0x04

5

0x05

6

0x06

7

0x07

8

0x08

9

0x09

When the S1 rotary encoder is set to position 3 (see above) you can allocate the wallbox a different device ID using the positions of the S3 encoder. Changing the device ID is intended for future applications and currently does not affect the operation of the wallbox. It is therefore recommended not to make any changes and to generally leave the S3 rotary encoder in the 0 position.

A

0x0A

B

0x0B

C

0x0C

D

0x0D

E

0x0E

F

0x0F

Mercedes-Benz Wallbox | Error detection and solutions

19

Search

Taking the product out of and back into operation
If required, you can take your Mercedes-Benz Wallbox out of operation. To take the wallbox out of operation, please proceed as follows:
1. Switch off the external RCCB (connection to the electricity grid is interrupted). 2. In addition, switch off the upstream MCB(s). 3. Always observe the five golden rules of electrical installation! Now, no charging procedure can be carried out with the Mercedes-Benz Wallbox and it can be uninstalled if required.
To take the wallbox back into operation at a later time, please proceed as follows:
1. Switch on the upstream MCB(s). 2. In addition, switch on the external RCCB (connection to the electricity grid is established). When the Mercedes-Benz Wallbox is reconnected to the electricity grid, it will reinitiate the start- up procedure: As described in section “Taking the wallbox into operation” on page 12 , the vehicle can now be connected for charging.
Returning your wallbox
Should your wallbox display error messages permanently during installation or subsequent operation, or if it does not function properly, contact your local Mercedes-Benz technical support. If the error can still not be resolved, repairs must be carried out. For this purpose, you must take the wallbox out of operation, uninstall it and return it via Mercedes-Benz technical support.
In addition to the wallbox itself, you must include the ‘Checklist for returns’ document with the parcel. Please ensure that the data entered in the document are correct and complete, and that the document has been signed by the customer as well as the installing technician. Otherwise, repairs cannot be carried out.
You can find the ‘Checklist for returns’ document on the www.yourwallbox.de website by following this link: www.yourwallbox.de/RMA-document

20

Search

Appendix

Technical specifications

Model Variant
Compliance Grid connection Rated voltage Rated current Rated frequency Max. output Charging outlet Circuit-protection devices Control / Customization Operating temperature Storage temperature Relative humidity Class of protection Overvoltage category Degree of pollution Degree of protection (housing) Impact strength Dimensions incl. mounting plate Dimensions w/o mounting plate Mounting plate dimensions Maximum elevation Weight per unit incl. mounting plate Weight per unit w/o mounting plate

A0009060407

A0009060607

IEC 61851-1 / 61439-7

for supply cable sizes of max. 5 x 16 mm²

230 / 400 V

16 A, 3-phase

32 A, 3-phase

50 Hz

11 kW

22 kW

Type 2 charging cable, ca. 6 m

Type 2 charging socket with shutter

DC-RCM electronic DC fault current detector, In d.c. 6 mA internal RS485 and USB interfaces (no user/installer access)

-30°C to 50°C

-30°C to 85°C

5 to 95% (no condensation)

I

III

3

IP54

IP44

IK08

492 x 400 x 194 mm (H x W x D)

492 x 400 x 162 mm (H x W x D)

477.9 x 376.4 x 32 mm (H x W x D)

2,000 m AMSL (above mean sea level)

ca. 14 kg

ca. 5.7 kg

ca. 13 kg

ca. 4.7 kg

Search

Mercedes-Benz Wallbox | Appendix

21

Scale drawings and dimensions
The Mercedes-Benz Wallbox is delivered fully assembled and checked. All dimensions as well as the mounting points are indicated in the scale drawings below. Mounting plate Plan and elevation (all dimensions in mm)
376,4
83

3 2 477,9

200 254

Wallbox with charging socket (Shutter)

Plan and elevation (all dimensions in mm)

194

400

492 134

22

Search

Wallbox with fixed charging cable

Plan and elevation (all dimensions in mm)

194

394

492 134

143

Contact chart Type 1/Type 2

PE

CP

PP

L1

L2/N

N

L1 CS

CP

L3

L2

Type2

PE
Type1

Search

Mercedes-Benz Wallbox | Appendix

23

Guidelines & Norms
The Mercedes-Benz Wallbox complies with the following standards and protection ratings:

General guidelines

Guideline
2014/30/EU 2011/65/EU 2012/19/EU 2014/35/EU ElektroG

Explanation
EMC Guideline RoHS 2 guideline WEEE Guideline Low voltage directive Electrical and Electronic Device Statute

Device safety standards
Standard
IEC 61851-1 Ed 2.0:2010 IEC/TS 61439-7:2014
DIN EN 61851-1: 2012-01 E DIN EN 61851-22:2011-04 HD 60364-7-722:2012

Explanation
Conductive charging systems for electric vehicles ­ Part 1: General requirements Part 7: Switching device combinations for specific applications such as marinas, campgrounds, market squares, charging stations for electric vehicles Conductive charging systems for electric vehicles ­ Part 1: General requirements Conductive charging systems for electric vehicles ­ Part 22: AC charging station for electric vehicles Low voltage installations ­ Part 7-722: Power supply for electric vehicles

Classes of protection & Degrees of protection

Class of protection / Degree of protection

Explanation

The device complies with IEC protection class 1.

IP 44 IP 54

Degree of protection of the device: Protection against the intrusion of solid particles more than 1 mm in diameter and against splashing water (model variant: A0009060607).
Degree of protection of the device: Protection against touch, dust in harmful quantities and protection from splashing water (model variant: A0009060407)

CE certification and declaration of compliance
The Mercedes-Benz Wallbox carries the CE mark. The associated compliance declaration is available for download in electronic format at www.yourwallbox.de.

24

Search

Glossary & Definitions

In the following, important abbreviations and terms used in this manual are explained.

DC DC-RCM LED MCB RCCB

Direct Current Direct Current Residual Current Monitor Light Emitting Diode Miniature Circuit Breaker Residual Current operated Circuit-Breaker

Direct current Monitoring device for detecting DC fault currents Light- emitting diode Residual current circuit breaker FI residual current circuit breaker

Trademarks
All trademarks mentioned in this manual including those that may be protected by third parties are, without restriction, subject to the regulations of the respectively applicable trademark law and the property rights of the respective registered owners.
All trademarks, trading names or company names marked here as such are or may be trademarks or registered trademarks of their respective owners. All rights not explicitly granted here are reserved.
The absence of explicit identification of trademarks used in this manual must not lead to the conclusion that a name is free from the rights of third parties.

Intellectual Property & Copyright
Copyright © 2017
Version 1.1, MB-IM-Wallbox-2017-03-06
All rights reserved.
Any information in this manual may be changed without prior notice and does not represent any obligation on the part of the manufacturer.
Illustrations in this manual may show designs different from the delivered product and do not represent any obligation on the part of the manufacturer.
The manufacturer does not take responsibility for any loss and/or damages that occur because of the data or possible misinformation contained in these instructions.
This manual, in its entirety or in parts, must not be reproduced, stored electronically or otherwise transmitted electronically, electrically, mechanically, optically, chemically, by photocopy or as an audio recording without the written permission of the manufacturer.

Search

Mercedes-Benz Wallbox | Appendix

25

Disposal advice
For the preservation and protection of the environment, the prevention of pollution and in order to improve the recycling of resources, the European Commission has issued a guideline (WEEE-Guideline 2002/96/EC and EAG-VO) according to which electrical and electronic devices are taken back by the manufacturer in order to have them properly disposed of or recycled.
Therefore, devices marked with this symbol may not be disposed of as part of unsorted domestic waste inside the European Union: Please inquire with your local authorities regarding proper disposal.
The materials are recyclable as marked. By re-using, recycling or through other forms of processing obsolete devices, you make an important contribution to environmental protection.

26

Search

Mains Connection Schemes

Country

Local

Local voltage

Phase L1 Phase L2 Phase L3 Neutral

frequency (domestic applications)

Albania

50 Hz

230 / 400 V

L1

L2

L3

N

Argentina

50 Hz

220 / 380 V

L1

L2

L3

N

Australia

50 Hz

230 / 400 V

L1

N

Azerbaijan

50 Hz

230 / 400 V

L1

L2

L3

N

Bahrain

50 Hz

230 / 400 V

L1

L2

L3

N

110 / 220 V

L1

L2

220 / 400 V

L1

N

Brazil

60 Hz

127 / 220 V

L1

L2

220 / 380 V

L1

L2

L3

N

Cayman Islands

60 Hz

120 / 240 V

L1

L2

Chile

50 Hz

220 / 380 V

L1

L2

L3

N

China

50 Hz

127 / 220 V 220 / 380 V

L1

L2

L1

L2

L3

N

Colombia

60 Hz

110 / 220 V

L1

L2

Eurasian Customs Union (Belarus, Kazakhstan, Russia)

50 Hz

230 / 400 V

L1

L2

L3

N

French Polynesia (Tahiti) 60 Hz

220 V

L1

N

Hong Kong

50 Hz

220 / 380 V

L1

L2

L3

N

220 / 380 V

India

50 Hz

230 / 400 V

L1

L2

L3

N

240 / 415 V

Indonesia

50 Hz

127 / 220 V 220 / 380 V

L1

L2

L1

L2

L3

N

Israel

50 Hz

230 / 400 V

L1

L2

L3

N

Jamaica

50 Hz

110 / 220 V

L1

L2

Japan

50 / 60 Hz

200 V

L1

L2

Jordan

50 Hz

220 / 380 V

L1

L2

L3

N

Kuwait

50 Hz

240 / 415 V

L1

L2

L3

N

Laos

50 Hz

230 / 400 V

L1

L2

L3

N

Lebanon

50 Hz

220 / 380 V

L1

L2

L3

N

Malaysia

50 Hz

240 / 415 V

L1

L2

L3

N

Macedonia

50 Hz

230 / 400 V

L1

L2

L3

N

New Zealand

50 Hz

230 / 400 V

L1

N

Oman

50 Hz

220 / 380 V 240 / 415 V

L1

L2

L3

N

Pakistan

50 Hz

230 / 400 V

L1

L2

L3

N

1-ph 3-ph
x x x x x x x x x x x x x x
x
x x
x
x x x
x x
x x x x x x x
x
x

Search

Mercedes-Benz Wallbox | Appendix

27

Country
Panama Qatar Saudi Arabia
Singapore South Africa South Korea Sri Lanka Taiwan
Thailand Ukraine United Arab Emirates
Vietnam

Local frequency
60 Hz

Local voltage (domestic applications)
220 V

Phase L1 Phase L2 Phase L3 Neutral

L1

L2

50 Hz

240 / 415 V

L1

L2

L3

N

127 / 220 V

L1

L2

60 Hz

220 / 380 V

L1

N

50 Hz

240 / 415 V

L1

N

50 Hz

230 / 400 V

L1

L2

L3

N

60 Hz

220 / 380 V

L1

N

50 Hz

230 / 400 V

L1

L2

L3

N

110 / 220 V

L1

L2

60 Hz

220 / 440 V

L1

N

50 Hz

220 / 380 V

L1

L2

L3

N

50 Hz

230 / 400 V

L1

L2

L3

N

50 Hz

220 / 380 V 240 / 415 V

L1

L2

L3

N

50 Hz

127 / 220 V 220 / 380 V

L1

L2

L1

L2

L3

N

1-ph 3-ph
x x
x x x
x x
x x x
x x
x
x x

Local

Local voltage

Region Country

Phase L1 Phase L2 Phase L3 Neutral

frequency (domestic applications)

Europe 50 Hz
(without Norway and UK)

230 / 400 V

L1

N

L1

L2

L3

N

Norway

50 Hz

110 V 230 / 400 V

L1

N

L1

L2

L3

N

UK

50 Hz

240 / 415 V

L1

N

1-ph 3-ph
x x
x x
x

28

Search

Search

Mercedes-Benz Wallbox | Appendix

29

The manufacturer may have made minor technical modifications to the product after publication of this instruction manual. This may also have led to minor discrepancies in the appearance of the product. Any color differences are a result of the printing process.
Daimler AG, Mercedesstr. 137, 70327 Stuttgart, Germany

Search