BlueMarine DC Power 1000 Energy Efficient Pump Instruction Manual

June 4, 2024
BlueMarine

DC Power 1000/2000-Energy Efficient Pump
Instruction Manual

DC Power 1000 Energy Efficient Pump

BlueMarine DC Power 1000 Energy Efficient Pump -
Overview

Safety

  1. Read the manual carefully before using it.
  2. Only suitable for indoor use.
  3. Ensure that water cannot reach the socket.BlueMarine DC Power 1000 Energy Efficient Pump - Fig 1
  4. Never let the pump run dry, keep it submerged at all times.
  5. Maximum water depth 1.5 meter
  6. The temperature of the fluid being pumped must never exceed 35° C.
  7. The pump must not be used to pump sewage, flammable, corrosive, or explosive liquids (e.g. petroleum oil, petrol, thinner), grease, oils, or foodstuffs.
  8. Unplug or switch off all appliances in the aquarium before carrying out maintenance.
  9. If damaged the supply cord cannot be replaced, the whole unit needs to be recycled.
  10. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning the use of the appliance in a safe way and understand the hazards involved. Children may not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.

Installation

  • Connect the pump to the controller’s lead, and connect the DC connector to the controller and the adapter. To make sure there is a good connection slide the 2 plugs firmly into each other.
    To make this easier you can soften the part that goes over the other plug with your fingers.

  • Put the adapter’s AC plug into the power socket and the pump will start.

  • The controller is not waterproof. Damage caused by water is not covered by warranty.

Operation

Speed up/down: Change the running speed of the pump, to adjust the flow. by turning the knob (a) left or right.BlueMarine DC Power 1000 Energy
Efficient Pump - Fig 3

Maintenance

  • Clean the pump monthly, depending on water and pollution conditions.
  • Regular cleaning extends the lifetime of the pump

Cleaning

  • clean the chamber inside with the brush;
  • clean the surfaces of the magnet and the impeller;
  • clean the shaft, bearing, and other space parts inside.

Disassembling sequence

  1. Remove the base by sliding it back and remove the front protector.BlueMarine DC Power 1000 Energy Efficient Pump - Fig 4
  2. Turn the pump head clockwise (Face the water inlet of the pump) and dismantle it.
  3. Take out the pump rotor.BlueMarine DC Power 1000 Energy Efficient Pump - Fig 6 Note: Please check whether the impeller works smoothly before installation. If not, please adjust it accordingly.

Troubleshooting

  • Stall protection: when something blocks the pump so that the rotor cannot rotate, the pump will automatically stop running after 1 sec. Switch off the pump and remove the blockage. Now the pump can be turned on again.
    • Water shortage protection: when there is too little water for the pump, it will stop running after 10 seconds. After 1 minute, the water pump will automatically start running. If there is still too little water, the pump will stop again after 10 seconds. After two of these cycles, the pump will continue in a cycle of stopping for 300 seconds and running for 10 seconds. This will ensure that the pump is not damaged. If enough water is detected during the 10-second operation of the pump, the protection is automatically released and the pump resumes normal operation. (only DC 2000)

Warranty

This warranty is valid for 2 years on materials and incorrect construction. Only units with a fully filled-in warranty slip and official receipt showing the date of purchase will be considered. You must supply the entire unit with accessories in the event of a warranty claim. We will inform you on a receipt whether the unit will be repaired or replaced. We accept no responsibility for damage as a result of incorrect use of the unit. Breakages of parts not due to defects ex-factory are not covered by this warranty.

Recycle information
The symbol of the barred bin printed on the product means that it must be collected separately from other rubbish when it will not be anymore in use. The user, at the end of the life of the product, will have to bring it to a proper rubbish collection center for electric and electrical devices. Alternatively, he can return the used product to the seller at the moment he buys a new unit, but only in proportion 1 to 1, a differentiated refuse collection is environmentally friendly and it helps with the recycling of the materials, any other collection procedure is unlawful and will be subject to the law in force.

– Always keep proof of purchase, without a purchase note no warranty!
Dealer stamp: ————————–
Date of purchase: ———————

Produced in China for:
www.aquadistri.com
Vlietweg 8 NL-4791 EZ Klundert

Documents / Resources

| BlueMarine DC Power 1000 Energy Efficient Pump [pdf] Instruction Manual
DC Power 1000 Energy Efficient Pump, DC Power 1000, Energy Efficient Pump, Efficient Pump, Pump
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals