BlueMarine 4000 DC Power Pump Instruction Manual

June 11, 2024
BlueMarine

BlueMarine 4000 DC Power Pump

Overviews

Overviews

Safety

  1. Read manual carefully before usage.
  2. Only suitable for indoor use.
  3. Ensure voltage shown on the label match to the mains supply voltage.
  4. Never let the pump run dry, keep it submerged at all times.
  5. Maximum water depth 1.5 meter
  6. The temperature of the fluid being pumped must never exceed 35° C.
  7. The pump must not be used to pump sewage, flammable, corrosive or explosive liquids (e.g. petroleum oil, petrol, thinner), grease, oils or foodstuffs.
  8. Unplug or switch off all appliances in the aquarium before carrying out maintenance.
  9. If damaged the supply cord cannot be replaced, the whole unit needs to be recycled
  10. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instructions concerning the use of the appliance in a safe way and understand the hazards involved. Children may not play with the appliance. Cleaning and user maintenance shall not be done by children without supervision.

Installation

  • Connect one cable from the controller to the pump cable and the other to the adapter cable. To make sure there is a good connection slide the 2 plugs firmly into each other. To make this easier you can soften the part that goes over the other plug with your fingers.
  • Put the adapter’s AC plug into the power socket, the pump controller’s LED display will light up and the pump will start.
  • The controller is not waterproof and has to be well amounted on the wall or the cabinet with a screw. Damage caused by water is not covered by warranty.

Operation

  • Speed up/down: Change the running speed of the pump, to adjust the flow. The pump has 9 speed modes, corresponding displayed as 01-09′ in the LED display.09′ Is the maximum speed of the pump.
  • Feeding ON/OFF: Press this button to stop the pump for 10 minutes. After 10 minutes, the pump will operate automatically. This function gives you the time to feed your fish without getting food in the filter. If you press the button again the pump will work again.

Maintenance

  • Clean the pump monthly, depending on water and pollution conditions.

  • Regular cleaning extents the lifetime of the pump.
    Disassembling sequence · Remove the base, turn the pump head counterclockwise (Face the water inlet of pump) and dismantle it.

  • Take out the pump rotor.
    Note: Please check whether the impeller works smoothly before installation. If not, please adjust it accordingly.
    Cleaning · Clean the chamber inside with the brush; · Clean the surfaces of the magnet and the impeller. · Clean the shaft, bearing and other space parts inside.

Troubleshooting

  • No water protection: When the pump is out of the water for more than 1 minute, the protection function starts and the pump stops running. At the same time, the LED display shows `E0′. The pump will try to resume work 9 times (each time for 1 minute), If after 9 times the problem still is not solved the pump will not automatically resume. You need to cut off the power supply and solve the problem before it can start working normally again.
  • Under voltage protection / overvoltage protection: When the pump input voltage is below or above the standard voltage and holds for more than 1 second, the system will automatically enable protection to stop the pump. After the input voltage has returned to normal and holds for more than 3 seconds, the system will automatically restart the pump. When the under voltage protection is activated, the LED display shows EL’, when the over voltage protection is activated, the LED display showsEH’.
  • Overload protection: When the pump is running and the pump load exceeds the rating the system identifies it as pump overload. The overload protection function is activated after about 1.5 seconds after the pump has stopped running. This protection function has the Inverse-time characteristic, the higher the overload, the faster the trigger. Starts automatically after the pump stops for 1 second, and the system will repeat the protection process until the overload is eliminated. When the overload protection is triggered, the LED display shows `EF’.
  • Over-temperature protection: The pump automatically stops running when the controller temperature exceeds 80°C, the LED display shows `EC’. The pump automatically starts running again when the controller temperature returns to 65°C or less.

Technical details

Model| Dimentions| Voltage| Power| Flow| Jet| In- and outlet| Noise
---|---|---|---|---|---|---|---
DC Power 4000| 145 x 70 x 110 mm| DC 24V| 43 W| 4000 L/h| 4.2| ø 20&25 mm| <42 dB
DC Power 6000| 0 145 x 70 x 110 mm| DC 24V| 72 W| 6000 L/h| 6.0| ø 20&25 mm| <42 dB
DC Power 8000| 167 x 80 x 120 mm| DC 24V| 85 W| W 8000 L/h| 5.0| ø 25&32 mm| <42 dB

Dealer stamp

  • Always keep proof of purchase, without purchase note no warranty!