OVERVIEW
FRONT VIEW
- Solar panel
- : Remote sensor reception indicator and outdoor channel selected
- : Outdoor remote sensor battery low
- Indoor temperature (Current / Max / Min)
- Indoor humidity (Current / Max / Min)
- : Clock signal reception indicator
- AM / PM
- : Main unit batteries low / no battery
- MODE: Change settings / display
- : Increase value of the setting; activate clock reception signal; toggle between outdoor channels (1-3)
- Outdoor temperature (Current / Max / Min)
- Outdoor humidity (Current / Max / Min)
- Weather forecast
- : Time zone offset
- Calendar / Clock with weekday / second
- : Ice alert LED indicator
- LIGHT: Activate backlight
- MEM: View current, maximum and minimum indoor / outdoor temperature and humidity
- : Decrease value of the setting; deactivate clock reception signal
BACK VIEW
- Wall mount hole
- RESET: Reset unit to default settings
- EU / UK: Select the nearest radio signal (BAR806HG only)
- °C / °F: Select temperature unit
REMOTE SENSOR
- LED status indicator
- Wall mount hole
- Battery compartment
- RESET hole
- CHANNEL switch
GETTING STARTED
SOLAR PANEL
The solar panel is an energy saving feature, which is an environmentally
friendly way to provide additional power to the main unit and prolongs battery
life. However, it cannot replace battery power entirely.
INSERT BATTERIES
- Remove the battery compartment.
- Insert the batteries, matching the polarities.
- Press RESET after each battery change.
REMOTE SENSOR
The main unit can collect data from up to 3 sensors.
To set up the sensor:
- Open the battery compartment.
- Insert the battery, matching the polarities.
- Select a channel. Press RESET after each battery change.
- Close the battery door.
- Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount.
TIP Ideal placements for the sensor would be in any location on the exterior of the home at a height of not more than 1.5 m (5 ft) and which can shield it from direct sunlight or wet conditions for an accurate reading.
NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.
SENSOR DATA TRANSMISSION
To search for a sensor:
Press and hold + MODE.
The sensor reception icon in the remote sensor area shows the status:
ICON | DESCRIPTION |
---|---|
Main unit is searching for sensor(s). | |
A channel has been found. | |
The sensor cannot be found. |
TIP The transmission range may vary depending on many factors. You may need to experiment with various locations to get the best results.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its clock automatically with a clock
signal.
BAR806HG:
Slide EU / UK to select the signal received.
- EU: DCF-77 signal: within 1500 km (932 miles) of Frankfurt, Germany.
- UK: MSF-60 signal: within 1500 km (932 miles) of Anthorn, England.
BAR806HGA:
- WWVB-60 signal: within 3200km (2000 miles) of Fort Collins Colorado.
To enable / disable signal reception:
Press and hold to enable or to disable signal reception.
NOTE Reception takes 2-10 minutes. If the signal is weak, it can take up
to 24 hours to get a valid signal. If signal reception is unsuccessful, place
your unit next to a window, press and hold to force another signal search.
Clock signal reception indicator:
STRONG SIGNAL | WEAK / NO SIGNAL |
---|---|
MANUALLY SET CLOCK
To set the clock manually, disable the signal reception first.
- Press and hold MODE.
- Press or to change the settings.
- Press MODE to confirm.
The settings order is: time zone, 12/24 hr format, hour, minute, year, calendar mode (day – month / month – day), month, day and language.
BAR806HG: Time zone offset sets the clock +/- 23 hours from the received
clock signal time. If you have deactivated the clock signal reception, do not
set a value for time zone.
BAR806HGA: Select the time zone: (P) Pacific, (E) Eastern, (C) Central or
(M) Mountain.
NOTE The language options are English (E), German (D), French (F),
Italian (I), and Spanish (S), and Russian (R).
To select display mode:
Press MODE to choose between clock with seconds / weekday / calendar.
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius.
| Sunny
---|---
| Partially Cloudy
| Cloudy
| Rainy
| Snowy
TEMPERATURE AND HUMIDITY
To toggle temperature unit:
Press °C / °F.
To toggle between each outdoor sensor’s readings:
Press repeatedly.
OR
Press and hold + MEM for 2 seconds to initiate auto toggle of outdoor
channels.
To end press .
To toggle between current, minimum and maximum records:
Press MEM repeatedly.
To clear the records:
Press and hold MEM.
ICE WARNING
If the channel 1 sensor falls between 3°C to -2 °C (37°F to 28°F), LED
indicator will flash, and will stop flashing once the temperature is out of this
range.
NOTE As ice alert is only applicable to channel 1, to prevent flashing of
LED, select channel 2 or 3 on outdoor sensor.
BACKLIGHT
Press LIGHT to activate backlight for 5 seconds.
RESET
Press RESET to return to the default settings.
PRECAUTIONS
- Do not subject the unit to excessive force, shock, dust, temperature or humidity.
- Do not cover the ventilation holes with any items such as newspapers, curtains etc.
- Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
- Do not clean the unit with abrasive or corrosive materials.
- Do not tamper with the unit’s internal components. This invalidates the warranty.
- Only use fresh batteries. Do not mix new and old batteries.
- Images shown in this manual may differ from the actual display.
- When disposing of this product, ensure it is collected separately for special treatment, and not as normal household waste.
- Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.
- The contents of this manual may not be reproduced without the permission of the manufacturer.
- Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
- Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.
NOTE The technical specifications for this product and the contents of the
user manual are subject to change without notice.
NOTE Features and accessories will not be available in all countries. For
more information, please contact your local retailer.
SPECIFICATIONS
TYPE | DESCRIPTION |
---|
MAIN UNIT
L x W x H| 94 x 46 x 160 mm
(3.7 x 1.8 x 6.3 in)
Weight| 222g (7.8 oz) without battery
Temperature range| -5°C to 50°C (23°F to 122°F)
Signal frequency| 433 MHz
Humidity range| 25% – 95%
Power| 3 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT (THGN132N)
LxWxH| 96 x 50 x 22 mm (3.78 x 1.97 x 0.87 in)
Weight| 62 g (2.22 ounces)
Transmission range| 30 m (98 ft) unobstructed
Temperature range| -20°C to 60°C (-4°F to 140°F)
Humidity range| 25% – 95%
Power| 1 x UM-3 (AA) 1.5 V batteries
ABOUT OREGON SCIENTIFIC
Visit our website
(www.oregonscientific.com) to learn
more about Oregon Scientific products. If you’re in the US and would like to
contact our Customer Care department directly, please visit:
www2.oregonscientific.com/service/support.asp
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
EU-DECLARTION OF CONFORMITY
Hereby, Oregon Scientific, declares that this Solar Weather Station with Outdoor Hygrometer (Model: BAR806HG / BAR806HGA) is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request via our Oregon Scientific Customer Service.
COUNTRIES RTTE APPROVAL COMPLIED
All EU countries, Switzerland
and Norway
FCC STATEMENT
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) This device may not
cause harmful interference, and (2) This device must accept any interference
received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to operate the
equipment.
NOTE This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
The following information is not to be used as contact for support or sales.
Please visit our website at
www2.oregonscientific.com/service
for all enquiries.
We
Name: Oregon Scientific, Inc.
Address: 19861 SW 95 th Ave.,Tualatin, Oregon 97062 USA
Telephone No.: 1-800-853-8883
declare that the product
Product No.: BAR806HG / BAR806HGA
Product Name: Solar Weather Station with Outdoor Hygrometer
Manufacturer: IDT Technology Limited
Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom,
Kowloon, Hong Kong
is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
© 2009 Oregon Scientific. All rights reserved.
300102202-00001-10
2009.4.17 5:29:10 PM
Documents / Resources
|
Oregon Scientific BAR806HG Solar Weather Station with Outdoor
Hygrometer
[pdf] User Manual
BAR806HG, BAR806HGA, BAR806HG Solar Weather Station with Outdoor Hygrometer,
Solar Weather Station with Outdoor Hygrometer, Station with Outdoor
Hygrometer, Outdoor Hygrometer, Hygrometer
---|---