Oregon Scientific Weather Station BAR388HGA User Manual
INTRODUCTION
Thank you for selecting this Oregon ScientificTM Wireless Weather Station with
Temperature / Humidity Display and Self-Setting Atomic Clock (BAR388HGA). This
clock is supplied with a remote sensor (THGR122N) and can support up to 3
sensors in total (additional sensors sold separately).
NOTE Please keep this manual handy as you use your new product. It contains
practical step-by-step instructions, as well as technical specifications and
warnings you should know about.
CLOCK OVERVIEW
- SNOOZE
- Weather Forecast Area
- Outdoor Temperature Area
- Indoor Temperature Area
- Clock / Alarm Area
- ALARM: View alarm status; set alarm
BACK VIEW
- Increase/decrease setting; activate/deactivate the clock reception signal.
- Change Settings display
- MODE: Switch Remote Sensor Display
- MEM: View current, maximum and minimum temperature / humidity
- PRESSURE: Select the pressure unit; set the altitude
- HEAT INDEX: Display heat index
- TEMP / HUMIDITY HI / LO: Change settings or enable/disable hi or lo temperature/humidity alarm for channel 1
- °C / °F: Select temperature unit
- RESET: Reset unit to default settings
- Battery compartment
LCD DISPLAY
Weather Forecast Area:
- Pressure trend
- Weather forecast
- Comfort zone
- Pressure icon
- Altitude icon
- Pressure/altitude unit
- Heat index icon
Outdoor Temperature Area:
- Heat index icon
- Hi / lo temperature alarm
- Sensor reception icon
- Sensor battery low
- Max/min icon
- Temperature display
- Ice warning is active
- Hi/lo humidity alarm
- Temperature trend
- Humidity trend
- Humidity display
Indoor Temperature Area:
- Indoor sensor icon
- Max/min icon
- Temperature display
- Temperature trend
- Humidity trend
- Humidity display
Clock / Alarm Area:
- Alarm set
- AM / PM icon
- Clock signal reception
- Low battery icon
- Clock
- Alarm mode icon
- Moon phase
REMOTE SENSOR (THGR122N)
-
LCD
-
LED status indicator: Blinks red during data transmission
-
Wall mount hole
-
RESET hole
-
CHANNEL switch
-
Battery compartment
GETTING STARTED
BATTERIES
Insert batteries before first use, matching the polarity (+ and -). Press RESET
after each battery change.
NOTE Do not use rechargeable batteries. We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing.
REMOTE SENSOR
The sensor collects temperature readings approx. every 40 seconds and sends
them to the main unit. The main unit can collect data from up to 3 sensors.
To set up the sensor:
- Remove the screws from the battery door.
- Insert the batteries, matching the polarity (+ / -).
- Select a channel. Make sure you use a different channel for each sensor.
- Place the sensor near the main unit. Press RESET on the sensor.
- Simultaneously press CHANNEL and MEM on the main unit to initiate signal sending between the sensor and main unit.
- Close the battery door and secure the screws.
- Place the sensor in the desired location using the table stand or wall mount.
For best results:
- Place the sensor out of direct sunlight and moisture.
- Do not place the sensor more than 30 m (100 ft) from the main (indoor) unit.
- Position the sensor so that it faces the main (indoor) unit, minimizing obstructions such as doors, walls, and furniture.
- Place the sensor in a location with a clear view to the sky, away from metallic or electronic objects.
- Position the sensor close to the main unit during cold winter months as below-freezing temperatures may affect battery performance and signal transmission.
The transmission range may vary depending on many factors. You may need to
experiment with various locations to get the best results.
Standard Alkaline batteries contain significant amounts of water. Because of
this they will freeze in low temperatures of approximately -12°C (10°F).
Disposable Lithium batteries have a much lower threshold for temperature with
an estimated freezing range of below -30°C (-22°F).
Wireless ranges can be impacted by a variety of factors such as extremely cold
temperatures. Extreme cold may temporarily reduce the effective range between
the sensor and the base station. If the unit’s performance fails due to low
temperature, the unit will resume proper functioning as the temperature rises
to within the normal temperature range (i.e. no permanent damage will occur to
the unit due to low temperatures).
SENSOR DATA TRANSMISSION
To search for a sensor:
Simultaneously, press and hold MEM and CHANNEL for 2 seconds.
NOTE If the sensor is still not found, check the batteries, obstructions, and
remote unit location.
CLOCK
CLOCK RECEPTION
This product is designed to synchronize its date and time automatically
once it is within range of the WWVB-60 signal from the atomic clock in Fort
Collins, Colorado.
The clock collects the radio signals whenever it is within 3219 km (2000
miles) of a signal.
NOTE Initial reception takes 2-10 minutes for first set up or when RESET is
pressed. Once complete, the reception icon will stop blinking. If the signal
is weak, it can take up to 24 hours to get a valid signal.
RECEPTION SIGNAL
Clock signal reception indicator:
To enable and force a signal search: Press and hold for 2 seconds.
To disable the signal reception: Press and hold for 2 seconds.
SET CLOCK
If the clock signal reception is enabled and a signal is being received the
clock does not need to be manually set.
- Press and hold MODE for 2 seconds.
- Press to change the settings.
- Press MODE to confirm.
- The settings order is: US time zone (Pacific (P), Eastern (E), Central (C) and Mountain (M)) offest, hour, minute, year, month, day and language.
NOTE The language options are English (E), German (D), French (F), Italian (I), and Spanish (S).
Press MODE to choose between the clock with seconds and clock with weekday display modes.
ALARM
To set the alarm:
- Press and hold ALARM for 2 seconds.
- Press to set hour/minute.
- Press ALARM to confirm. indicates the alarm is ON.
To enable/disable the alarm:
- Press ALARM to display alarm time.
- Press ALARM again to turn alarm ON / OFF.
To silence the alarm:
-
Press SNOOZE to silence it for 8 minutes.
OR -
Press any key except SNOOZE to turn the alarm off and activate it again after 24 hours.
BAROMETER
Barometer readings from the past 24 hours are stored by the main unit and used
to provide weather forecasts.
To select a barometer measurement unit:
Press PRESSURE to toggle between mb and inHg.
SET ALTITUDE
To ensure barometric readings are reliable set the altitude to reflect distance
from sea level at your position.
- Press and hold PRESSURE for 2 seconds.
- Use and to set the altitude in 10 m (33 ft) increments from -100 m (-328 ft) to 2500 m (8202 ft).
- Press PRESSURE to confirm.
NOTE The maximum operating altitude for the barometer and weather forecast is 2500m (8202 ft).
WEATHER FORECAST
This product forecasts the next 12 to 24 hours of weather within a 30-50 km (19-31 mile) radius based on barometric pressure trend readings.
TEMPERATURE AND HUMIDITY
-
To toggle temperature unit:
Press °C / °F. -
To view outdoor sensors temperature readings:
Press CHANNEL. -
To auto-scan between sensors:
Press and hold CHANNEL for 2 seconds.
Each sensor’s data is displayed for 3 seconds. -
To end auto-scan:
Press CHANNEL or MEM.
To toggle between current, minimum and maximum records for the selected sensor:
Press MEM repeatedly. -
To clear the records:
Press and hold MEM for 2 seconds.
TEMPERATURE, HUMIDITY AND PRESSURE TREND
The temperature, humidity and pressure trend icons are based on recent sensor
readings
ICE WARNING
If the channel 1 sensor falls between 3°C to –2°C (37°F to 28°F), flashes to
warn you that the temperature is approaching freezing.
NOTE The warning will automatically stop if the temperature goes outside the
ice-warning range.
HI / LO TEMPERATURE /HUMIDITY ALARMS
Temperature and humidity alerts can be set to sound if the sensor set to
channel 1 records above or below a temperature/humidity of your choice.
To set alarm ON / OFF:
- Press and hold TEMP / HUMIDITY HI / LO.
- Use and to select high/low temperature/humidity alarm. Press TEMP / HUMIDITY HI / LO to confirm.
- Press to set alarm ON / OFF and press TEMP / HUMIDITY HI / LO to confirm.
- If the alarm has been activated, use and to select the temperature/humidity.
- Press TEMP / HUMIDITY HI / LO to confirm.
To silence the hi/lo alarm:
Press any key. The alarm resets automatically and will resound if the hi / lo
temperature is recorded again.
HEAT INDEX
The heat index combines temperature and humidity data to describe the actual temperature felt.
WARNING | HEAT INDEX | MEANING |
---|---|---|
Extreme danger | 54.5°C / (130°F) |
or above
| Strong risk of
dehydration / sun stroke
Danger| 40.5 – 54°C
(105 – 129°F)
| Heat exhaustion
likely
Extreme caution| 32.2 – 40°C
(90 – 104°F)
| Possibility of heat dehydration
Caution| 26.6 – 31.7°C
(80 – 89°F)
| Possibility of heat exhaustion
- To display the heat index, press HEAT INDEX.
- To toggle between current/maximum/minimum readings, press HEAT INDEX, then press CHANNEL to select channel 1-3 or indoor, followed by MEM.
- To toggle between temperature/humidity and heat index display, press and hold HEAT INDEX for 2 seconds. Press HEAT INDEX again to stop this feature.
NOTE If the heat index is below 80°F / 26°C, or the desired channel is not working, the heat index will display NA .
COMFORT ZONE
The comfort zone assesses the climate based on current temperature and humidity measurements.
MOON PHASE
- When the calendar is set press or to view the moon phase for the next/previous day.
- Press and hold or to scan through the years (2001 to 2099).
RESET
Press RESET to return the unit to the default settings.
PRECAUTIONS
This product is engineered to give you years of satisfactory service if you
handle it carefully. Here are a few precautions:
- Do not subject the unit to excessive force, shock, dust, temperature or humidity, which may result in malfunction, shorter electronic life span, damaged battery and distorted parts.
- Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
- Do not clean the unit with abrasive or corrosive materials.
- Do not tamper with the unit’s internal components. Doing so will invalidate the warranty on the unit and may cause unnecessary damage. The unit contains no user-serviceable parts.
- Only use fresh batteries as specified in the user’s instructions. Do not mix new and old batteries.
- Due to printing limitations, the displays shown in this manual may differ from the actual display.
- The contents of this manual may not be reproduced without the permission of the manufacturer.
- Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
NOTE The technical specifications for this product and the contents of the user manual are subject to change without notice.
SPECIFICATIONS
L x W x H| 119 x 77 x 169 mm
(4.7 x 3.0 x 6.7 in)
---|---
Weight| 249 g (8.8 oz) without battery
Temperature unit| °C / °F
Temperature range| -5°C to 50°C (23°F to 122°F)
Resolution| 0.1°C (0.2°F)
Clock frequency| WWVB-60
Synchronization| Auto or disabled
Signal frequency| 433 MHz
Clock| Auto or manual (disabled)
Humidity range| 25% – 95%
Humidity resolution| 1%
Memory| Min / Max relative humidity and temperature
Alarm duration| 2 minutes
Snooze| 8 minutes
Clock display| HH:MM:SS
HH:MM: Day of Week
Hour format| 12 / 24 hour format
Calendar| MM / DD or DD / MM
language selectable: E, D, F, I and S
Power| 3 x UM-3 (AA) 1.5 V batteries
REMOTE UNIT
L x W x H| 92 x 60 x 20 mm
(3.6 x 2.4 x 0.8 in)
---|---
Weight| 62 g (2.22 oz)
Transmission range| 30 m (100 ft) unobstructed
Temperature range| -30°C to 60°C
(-22°F to 140°F)
Power| 2 x UM-4 (AAA) 1.5 V batteries
NOTE We recommend that you use alkaline batteries with this product for longer usage and lithium batteries in temperatures below freezing.
ABOUT OREGON SCIENTIFIC
Visit our website (www.oregonscientific.com) to learn more about Oregon
Scientific products such as digital cameras; MP3 players; children’s electronic
learning products and games; projection clocks; health and fitness gear;
weather stations; and digital and conference phones. The website also includes
contact information for our Customer Care department in case you need to reach
us, as well as frequently asked questions and customer downloads.
We hope you will find all the information you need on our website, however, if
you’re in the US and would like to contact the Oregon Scientific Customer Care
department directly, please visit:
www2.oregonscientific.com/service/default.asp
OR
Call 1-800-853-8883.
For international inquiries, please visit:
www2.oregonscientific.com/about/international.asp
FCC STATEMENT
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
WARNING Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio / TV technician for help.
DECLARATION OF CONFORMITY
- Name: Oregon Scientific, Inc.
- Address: 19861 SW 95th Ave.,Tualatin, Oregon 97062 USA
- Telephone No.: 1-800-853-8883 declare that the product
- Product No.: BAR388HGA
- Product Name: Wireless Weather Station with Temperature / Humidity Display and Self – Setting Atomic Clock
- Manufacturer: IDT Technology Limited
- Address: Block C, 9/F, Kaiser Estate, Phase 1,41 Man Yue St., Hung Hom, Kowloon, Hong Kong is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.
Download PDF:Oregon Scientific Weather Station BAR388HGA User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>