Fast Track Troubleshooting
Publication # nwRFG297HD Revision Date 09/28/11
IMPORTANT SAFETY NOTICE – “For Technicians Only” This service data sheet is intended for use by persons having electrical, electronic, and mechanical experience and knowledge at a level generally considered acceptable in the appliance repair trade. Any attempt to repair a major appliance may result in personal injury and property damage. The manufacturer or seller cannot be responsible, nor assume any liability for injury or damage of any kind arising from the use of this data sheet.
Self Diagnosis: Press both buttons (Energy Saver– Lighting)
simultaneously (No sound when both buttons are pressed at the same time) ‟til
the display quits blinking and beeps, 8-12 seconds, then release and read
Fault Codes.
This will also cancel the Fault Mode created by self-diagnosis at power up.
Forced Mode: Press both buttons (Energy Saver– Fridge) simultaneously (No sound when both buttons are pressed at the same time)„ til it beeps and goes blank, 8-12 seconds.
Wait 5 seconds between button pushes
-
3600RPM
Press Freezer button one time at the Test Mode to Force Compressor High Speed Run, measure fan and Compressor voltages at main PCB.
-
2450RPM
Press Freezer button a second time to Force Mid Speed Run.
-
2200RPM
Press Freezer button a third time to Force Low Speed Run
-
Press Freezer button a forth time to Force Defrost of Fridge & Freezer, measure defrost voltage at main PCB
Refrigerant Charge
R134a | 5.64 oz.
Sealed System
- Compressor → Sub-condenser → Hot Pipe → Back Cluster Pipe → Dryer → R Capillary Tube → Refrigerator Evaporator → Connected Capillary → Freezer Evaporator → Suction Pipe → Compressor
- Compressor → Sub-condenser → Hot Pipe → Back Cluster Pipe → Dryer →F Capillary Tube → Freezer Evaporator → Suction Pipe → Compressor
Sales Mode, No Compressor Operation.
Press Energy Saver & Freezer temp buttons simultaneously for 3 sec ( you will
hear a “Ding Dong”) to remove or put into Sales Mode. When in the Sales Mode
the Display will show “OF” “OF”
Removing power will not cancel this mode.
Component Value Chart
Component | Resistance | Wattage | Voltage |
---|---|---|---|
Freezer Defrost Heater | 60Ω | 240 | 120vac |
Fridge Defrost Heater | 120Ω | 120 | 120vac |
French Mullion Heater | 1800Ω | 8 | 120vac |
Ice Duct Heater | 3600Ω | 4 | 120vac |
Dispenser Heater | 7200Ω | 2 | 120vac |
Water Tank Heater | 72Ω | 2 | 12vdc |
Sensors | 2.5kΩ-89kΩ | N/A | 1~4.5vdc |
Fans | N/A | N/A | 7~12vdc |
DC FAN MOTORS
Brushless DC Fan motors are used to save energy. The fans operate at two speeds. Fan speed information is read by the Main PCB. If the fan speed exceeds 600 RPM or the speed is too slow, or stopped the fan drive circuit is disabled, After 10 seconds the circuit tries again with 3 seconds of DC voltage If the fan continues this activity for 5 cycles, 10 seconds off 3 seconds on, the fan drive circuit is disabled for 10 minutes.
TO TEST THE FAN CIRCUIT VOLTAGE.
Power off and back on to check the DC voltage to the motor, wait from 10 to 60 seconds for the fan voltage to kick in, and then check fan voltage, the average reading is 9 VDC. If you get 3 seconds of voltage every 10 seconds for the 5 fan power up cycles, then the Main PCB is good.
NOTE: You may need to put unit in FORCED FREEZE mode to activate the fans/compressor.
If the fan blade is blocked by ice, then defrost and check the motor again, after removing power from the unit. If the evaporator is ice blocked and thus blocking the air flow, the fan will over RPM and is stopped. Remove ice and check the motor again. If everything is clear around the fan blade then the motor would be at fault. Continuous fan errors will be displayed on the front panel display. PLEASE NOTE: The door switches control the evaporator fan motors. Have them closed to test the motors. Delay time 10 – 60 seconds.
Heat Release Ice Makers
Heat Release Ice production Explanation
38 minutes after the water fill is complete, the control board will check the temperature of the eject Thermistor, on the Ice Maker Head, if the Thermistor reads a temperature lower than 18.5 degrees for more than 5 seconds, then the ice production process is completed. The Ice maker will harvest if the ice bucket is not sensed as full. If a Fault Mode is detected with the Ice Maker operation, the Ice Maker stops working for 3 hours. Which means, the Ice Maker checks the operation every 3 hours until it works properly.
Heat Release I/M Test Mode
Press and hold the ICE TEST S/W for at least 1.5sec, the harvest function will start. If the ice maker Thermistor is below 0 degrees the Ice maker heater turns on for about 2 minutes. If the temperature exceeds 0 degrees, Ice maker heater turns on for 30 seconds. After the Ice maker heater turns on for 30 seconds, the heater turns off and then Ice maker harvest motor turns on. The motor will rotate in right direction for about 3 minutes, after this, water supply valve is turned on, then the valve is turned off, the test mode is completed. If the above operation is not carried out within 6 minutes, it will go into a fault mode.
FREEZER TEMPERATURE CONTROL BY THE ICE MAKER
Interior Temperature of the freezer will be set to -14 degrees Fahrenheit until the ice bucket is full. When the ice bucket is full, the freezer will maintain original set temperature. Also, whenever the ice is used, the freezer will again set to -14 degrees Fahrenheit. Selecting “Ice Off” will allow the freezer to be controlled by the set temperature. If water is not hooked up, the freezer will always be at –14 unless “Ice Off” is selected.
Temperature/Resistance/Voltage Chart for Samsung Refrigerators Sensors
Temp.| (Ω)| Volts| | Temp.| (Ω)| Volts| |
Temp.| (Ω)| Volts| | Temp.| (Ω)| Volts
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---
-29.2°F| 64227| 4.326| | 1.4°F| 28021| 3.685| | 32.0°F| 13290| 2.853| | 62.6°F| 6771| 2.019
-27.4°F| 61012| 4.296| | 3.2°F| 26760| 3.64| | 33.8°F| 12749| 2.802| | 64.4°F| 6521| 1.974
-25.6°F| 57977| 4.264| | 5.0°F| 25562| 3.594| | 35.6 °F| 12233| 2.751| | 66.2°F| 6281| 1.929
-23.8°F| 55112| 4.232| | 6.8°F| 24425| 3.548| | 37.4 °F| 11741| 2.7| | 68.0°F| 6052| 1.885
-22.0°F| 52406| 4.199| | 8.6°F| 23345| 3.501| | 39.2 °F| 11271| 2.649| | 69.8°F| 5832| 1.842
-20.2°F| 49848| 4.165| | 10.4°F| 22320| 3.453| | 41.0°F| 10823| 2.599| | 71.6°F| 5621| 1.799
-18.4°F| 47431| 4.129| | 12.2°F| 21345| 3.405| | 42.8°F| 10395| 2.548| | 75.2°F| 5225| 1.716
-16.6°F| 45146| 4.093| | 14.0°F| 20418| 3.356| | 44.6°F| 9986| 2.498| | 77.0°F| 5000| 1.675
-14.8°F| 42984| 4.056| | 15.8°F| 19537| 3.307| | 46.4°F| 9596| 2.449| | 78.8°F| 4861| 1.636
-13.0°F| 40938| 4.018| | 17.6°F| 18698| 3.258| | 48.2°F| 9223| 2.399| | 80.6°F| 4690| 1.596
-11.2°F| 39002| 3.98| | 19.4°F| 17901| 3.208| | 50.0°F| 8867| 2.35| | 86.0°F| 4218| 1.483
-9.4°F| 37169| 3.94| | 21.2°F| 17142| 3.158| | 51.8°F| 8526| 2.301| | 87.8°F| 4072| 1.447
-7.6°F| 35433| 3.899| | 23.0°F| 16419| 3.107| | 53.6°F| 8200| 2.253| | 89.6°F| 3933| 1.412
-5.8°F| 33788| 3.858| | 24.8°F| 15731| 3.057| | 55.4°F| 7888| 2.205| | 91.4°F| 3799| 1.377
-4.0°F| 32230| 3.816| | 26.6°F| 15076| 3.006| | 57.2°F| 7590| 2.158| | 95.0°F| 3547| 1.309
-2.2°F| 30752| 3.773| | 28.4°F| 14452| 2.955| | 59.0°F| 7305| 2.111| | 96.8°F| 3428| 1.277
-0.4°F| 29350| 3.729| | 30.2°F| 13857| 2.904| | 60.8°F| 7032| 2.064| | 100.4°F| 3204| 1.213
Error Code| Item| Trouble contents
---|---|---
1 E| FZ SENSOR ERROR| The respective sensor is read as open or shorted,
check the wiring connections in the respective compartment and at the Main PCB
2 E| R SENSOR ERROR
4 E| FZ DEF SENSOR ERROR
5 E| R DEF SENSOR ERROR
6 E| AMBIENT-SENSOR ERROR
7 E| FLEX SENSOR ERROR
13 E| HUMIDITY-SENSOR ERROR| The Humidity sensor is read as open or
shorted, check the wiring connections in the respective compartment and at the
Main PCB
14 E| IM SENSOR ERROR| The respective sensor is read as open or shorted,
check the wiring connections in the respective compartment and at the Main PCB
15 E| ICE RM SENSOR ERROR
21 E| FZ FAN ERROR| The Freezer Fan motor is read as not connected or
the fan has stopped, check the wiring connections in the freezer and at the
Main PCB
22 E| R FAN ERROR| The Ref. Fan motor is read as not connected or the
fan has stopped, check the wiring connections in the freezer and at the Main
PCB
23 E| C-FAN ERROR| The Comp. Fan motor is read as not connected or the
fan has stopped, check the wiring connections in the freezer and at the Main
PCB
24 E| FZ DEF FUNCTION ERROR| The freezer defrost heater is read as open
or the heater has been heating continuously for more than 80 minutes.
25 E| R DEF FUNCTION ERROR| The refrigerator defrost heater is read as
open or the heater has been heating continuously for more than 80 minutes.
39 E| IM FUNCTION ERROR| The Icemaker release heater reads as open
circuit
40 E| ICE-ROOM-FAN ERROR| The Ice Room Fan motor is read as not
connected or the fan has stopped, check the wiring connections in the freezer
and at the Main PCB
41 E| MAIN<->LCD COMM ERROR| The Main PCB and the LCD display are not
communicating properly verify the wiring at both PCB’s
81 E| COMP STARTING FAILURE| The compressor did not start properly,
check for an overload condition
82 E| COMP IPM FAULT ERROR| Inverter power control issue, Check the
Inverter Drive PCB
83 E| COMP ABNORMAL CURRENT DETECTION| Excessive current detected at the
Compressor check the compressor windings for shorts
84 E| COMP MOTOR LOCKED OVER RPM ERROR| Compressor Over speed error
check for low refrigerant levels
85 E| COMP UNDER VOLTAGE| Low voltage to the compressor Check the DC
supply from the Main PCB
86 E| COMP OVER VOLTAGE| Over voltage to the compressor Check the DC
supply from the Main PCB
Compressor & System Operation Testing
The Time Divided Multi-cycle (TDM) System (Stepper Valve) is used to switch
refrigerant flow . This improves temperature control and energy efficiency.
If it fails in the all evaporator mode, it should work properly, using
slightly more energy. If it fails in the Freezer evaporator only mode, there
will be a Fridge no cool Force on the Fridge with the “Power Cool” option.
Monitor the Fridge evaporator(s) temp by using the Defrost Sensor(s). If the
temp doesn’t decrease, then suspect the Main PCB is not supplying signal to
switch the diverter valve.
TEST BEFORE INTERPRETING LED BLINKING FREQUENCY
Compressor not running
- Activate Forced Compressor Operation, wait 2 minutes (in case of high head pressure)
- If compressor doesn’t start, check CN75 for 2.5vdc (if not there replace Main PCB)
- If voltage is OK, remove power, disconnect CN03 (Inverter PCB) and check resistance to the windings. Approximately 10 ohms. If not correct , inspect wire harness, if OK replace compressor.
- Disconnect CN02 (SMPS PCB), check resistance to Overload , if open replace overload.
Protection Functions| LED Blinking Frequency| Test|
Replace
---|---|---|---
Starting Failure| | Check the Inverter PCB & Comp Relay Connectors| Connectors
OK,replace Inverter PCB, if same, replace compressor
SPM Fault| | If blinking after reset,| Check System for restriction &
refrigerant, if OK replace Inverter, if same, replace compressor
Detecting Position Failure| | Check Inverter Connectors,| Connectors measure
OK, replace compressor, if same, replace Inverter PCB
Motor Locked| | Compressor Locking| Compressor
Low Voltage| | Compressor Locking, check input voltage| Replace
Inverter PCB, if same, replace Compressor
Over Voltage| | Compressor Locking, check input voltage| Replace
Inverter PCB, if same, replace Compressor