WAYNE SSCDU800 Submersible Sump Pump User Manual

June 16, 2024
WAYNE

WAYNE SSCDU800 Submersible Sump Pump

Product Information

Specifications

  • Construction: Submersible Sump Pump
  • Power supply requirements: 120V, 60 Hz
  • Motor: Intermittent
  • Horsepower: 1/3 HP (SPF33, CDU790, & CDU790HH)

Description
The submersible pump is designed for home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. The motor is oil filled and sealed for cooler running and designed to operate under water. A float switch is provided for automatic pump operation. Please note that this pump is not suitable for aquatic life.

General Safety Information

  • DANGER: Do not use the pump to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. It should not be used in a flammable and/or explosive atmosphere. The pump should only be used to pump clear water. Failure to comply with these instructions could result in personal injury and/or property damage.
  • NOTICE: This pump is not designed to handle salt water, brine, laundry discharge, water softener, sewage, graywater, or any other application that may contain caustic chemicals and/or foreign materials. The CDU790HH pump is capable of handling laundry discharge. Pump damage could occur if used in these applications and will void the warranty.
  • WARNING: All wiring must be performed by a qualified electrician.
  • DANGER: If the basement has water or moisture on the floor, do not walk on the wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove the pump and either repair or replace it. Failure to follow this warning could result in fatal electrical shock.
  • NOTICE: A backup system should be used. Please call 1-800-237-0987 for the backup model number.

Installation

  1. Install the pump in a sump pit with a minimum size as shown in Figure 1. The sump pit can be constructed of tile, concrete, steel, or plastic.
  2. The unit should be located and rest on a solid, level foundation. Do not place the pump directly on clay, earth, gravel, or sandy surface as these surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure.

WARNING: If a flexible discharge hose is used, make sure the pump is secured in the sump pit to prevent movement. Failure to do so may result in flood risk.

Figure 1: Sump Pit Installation

FAQ

  • Q: Can I use this pump to pump salt water?
    A: No, this pump is not designed to handle salt water. Using it for that purpose may cause pump damage and void the warranty.

  • Q: Can I use this pump for sewage or graywater?
    A: No, this pump is not suitable for sewage or graywater. Using it for those applications may cause pump damage and void the warranty.

  • Q: Can I install this pump myself?
    A: The installation of the pump should be performed by a qualified electrician to ensure proper wiring and safety.

Operating Instruction and Parts Manual

Models FLS790, FLS800, SPF33, SPF50, SSCDU800, SSPF50, CDU790, CDU790HH, CDU800 & CDU980

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! Retain instructions for future reference.

Submersible Sump Pump

Description

The submersible pump is designed for home sump applications. The unit is equipped with an 8-ft long, 3-prong grounding type power cord. Motor is oil filled and sealed for cooler running and designed to operate under water. A float switch is provided for automatic pump operation. This pump is not suitable for aquatic life.

General Safety Information

DANGER
Do not use to pump flammable or explosive fluids such as gasoline, fuel oil, kerosene, etc. Do not use in a flammable and/or explosive atmosphere. Pump should only be used to pump clear water. Personal injury and/or property damage could result.

NOTICE
This pump is not designed to handle salt water, brine, laundry discharge, water softener, sewage, graywater or any other application which may contain caustic chemicals and/or foreign materials. The CDU790HH pump is capable of handling laundry discharge. Pump damage could occur if used in these applications and will void warranty.

WARNING
All wiring must be performed by a qualified electrician.

DANGER
If the basement has water or moisture on the floor, do not walk on wet area until all power is turned off. If the shutoff box is in the basement, call an electrician. Remove pump and either repair or replace. Failure to follow this warning could result in fatal electrical shock.

NOTICE
A backup system should be used. Call 1-800-237-0987 for backup model number.

Installation

  1. Install pump in a sump pit with minimum size as shown below. Construct sump pit of tile, concrete, steel or plastic.

  2. The unit should be located and rest on a solid, level foundation. Do not place pump directly on clay, earth, gravel or sandy surface. These surfaces contain small stones, gravel, sand, etc. that may clog or damage the pump and cause pump failure.
    ! WARNING
    Flood risk. If flexible discharge hose is used, make sure pump is secured in sump pit to prevent movement. Failure to secure pump could allow pump movement and switch interference and prevent pump from starting or stopping.

  3. Thread (optional) check valve into pump body carefully to avoid stripping or cross threading.
    Do not use pipe joint sealant.

  4. Connect 1-1/4″ rigid pipe to rubber boot on check valve. Reverse boot for 1-1/2″ diameter pipe.
    Tighten hose clamps.
    ! WARNING
    Support pump and piping when assembling and after installation. Failure to do so could cause piping to break, pump to fail, etc. which could result in property damage and/or personal injury.

  5. Protect electrical cord from sharp object, hot surfaces, oil and chemicals. Avoid kinking the cord and replace damaged cords immediately.

  6. A sump pit cover must be installed to prevent debris from clogging or damaging the pump.

FLOOD ALERT MODELS (SEE FIGURE 2)
Remove battery access door and connect a 9-volt battery to battery terminal. Replace battery access door.

Operation

DANGER
Always disconnect the power source before attempting to install, service, relocate or maintain the pump. Never touch sump pump, pump motor, water or discharge piping when pump is connected to electrical power. Never handle a pump or pump motor with wet hands or when standing on wet or damp surface or in water. Fatal electrical shock could occur.

  1. A ground fault circuit interrupter (GFCI) is required (See Figure 2).
    ! WARNING
    Risk of electrical shock! This pump is supplied with a grounding conductor and grounding type attachment plug. Use a grounded receptacle to reduce the risk of fatal electrical shock.
    IMPORTANT: Never cut off the round grounding prong. Cutting the cord or plug will void the warranty and make the pump inoperable.

  2. This pump is only for use on 120 Volt (single-phase), 60 hz, 15 amp service and is equipped with a 3-conductor cord and 3-prong, grounding type plug.

  3. Insert the pump power cord plug directly into outlet (See Figure 2).

  4. Fill sump with water. The pump will start automatically when the water has filled the sump to a depth of approximately 9″. The pump will stop when the water depth is approximately 4″. The pump will recycle thereafter as required.

  5. Do not operate the pump unless it is submerged in water. Dry running causes pump failure.

  6. The motor is equipped with an automatic reset thermal protector.

  7. While the pump is draining the pit, verify that the discharge piping is carrying the water to a point several feet away from the foundation.

  8. If pump discharge line is exposed to freezing temperature, the exposed line must be pitched to drain. Trapped water will freeze and damage the pump.

FLOOD ALERT MODELS (SEE FIGURE 2)

  1. Unit should be plugged into outlet as shown in Figure 2. Do NOT plug unit in upside down. Doing so may cause pump to unplug. If your receptacle is upside down, have a qualified electrician reposition the outlet before installing the unit.
  2. Testing Alarm: Press and hold test button until alarm sounds. If alarm does not activate after 3 seconds, check and/or replace battery then repeat test.
  3. Alarm activates when water raises the water level sensor (See Figure 3).
  4. NOTE: Test water level sensor operation by lifting it until alarm activities.
  5. NOTICE Check battery once a month to ensure proper alarm operation. Replace battery every six months.

Maintenance

DANGER
Always disconnect the electrical supply before attempting to install, service, relocate or perform any maintenance. If the power source is out of sight, lock and tag in the open
(off) position to prevent unexpected power application. Failure to do so could result in fatal electrical shock. Only qualified electricians should repair this unit. Improper repair could result in fatal electrical shock.

  1. Let the pump cool for a minimum of two hours before servicing because the pump contains hot oil under pressure and the motor is hot.
  2. Disassembly of the motor prior to expiration of warranty will void the warranty. If repairs are required, see troubleshooting chart.
  3. Inlet should be kept clean and free of all foreign objects and inspect annually. A clogged inlet will damage pump.
  4. Pump should be checked monthly for proper operation.

WARNING
This pump contains cooling. This oil can be harmful to the environment. Check the state environmental laws before disposing this oil.

Part Replacement Schedule
All service and repair must be done by qualified pump repair personnel. Failure to follow the replacement schedule or use qualified pump repair personnel will void the lifetime warranty.

  • Replace pump switch every 2 years. See page 4 for replacement part number.
  • Replace float every 2 years. See page 4 for replacement part number.
  • Replace stator every 5 years. See page 4 for replacement part number.

Troubleshooting Chart

For Replacement Parts, call 1-800-237-0987

  • Please provide following information:
    • Model number
    • Serial number (if any)
    • Part description and number as shown in parts list
  • Address parts correspondence to: Wayne Water Systems
  • 100 Production Drive
  • Harrison, OH 45030 U.S.A.

Replacement Parts List

Ref. No.| Description| Part Numbers SPF33| for Models: SPF50| SSPF50| CDU790| CDU800
---|---|---|---|---|---|---
1| Float Kit| 60038-001| 60038-001| 60042-001| 60038-001| 60038-001
2| Top Cover Kit| 60017-001| 60017-001| 60040-001| 60017-001| 60017-001
3| Stator| 32064-S01| 32074-S03| 32050-S04| 32064-S01| 32074-S01
4| Lower Bracket/ Rotor Assembly| 60002-001| 60003-001| 60003-002| 60002-001| 60003-001
5| Impeller Plate| 15958| 15958| 15958| 15958| 15958
6| Impeller| 60000-001| 60001-001| 60001-001| 60000-001| 60001-001
7| Volute| 60007-001| 60007-001| 60007-001| 60039-001| 60039-001
Ref. No. Description

1  Float Kit

| Part Numbers for Models: CDU790HH

60038-001

| CDU980

60042-001

| SSCDU800

60042-001

| FLS790

60038-001

| FLS800

60038-001

---|---|---|---|---|---
2  Top Cover Kit| 60017-001| 60040-001| 60040-001| 60082-001| 60082-001
3  Stator| 32064-S01| 32050-S04| 32050-S04| 32064-S01| 32050-001
4  Lower Bracket/ Rotor Assembly| 60002-001| 60081-001| 60003-002| 60002-001| 60003-001
5  Impeller Plate| 15958| 15958| 15958| 15958| 15958
6  Impeller| 60000-001| 60001-001| 60091-001| 60000-001| 60001-001
7  Volute| 60039-001| 60039-001| 60039-001| 60039-001| 60039-001

Specifications

  • Power supply requirements . . . . . . . . . . . . . . . .120V, 60 Hz
  • Motor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Intermittent
  • Horsepower . . . . . . . . . . . . . . . . . . .1/3 HP (SPF33, CDU790, & CDU790HH)
    • 1/2 HP (FLS800, SPF50, SSCDU800, SSPF50, & CDU800)
    • 3/4 HP (CDU980)
  • Liquid temperature range . . . . . . . . . . . . . . . . 40°F to 120°F
  • Liquid temperature range (CDU790HH only) . . . . 40°F to 190°F
  • Circuit requirements . . . . . . . . . . . . . . . . . . . .15 amps (min)
  • Dimensions . . . . . . . . . . . . . . . . . . . . .111/2″ high x 93/4″ base
  • Cut-in level (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . . .9″
  • Cut-out level (factory set) . . . . . . . . . . . . . . . . . . . . . . . . . .4″

Construction

  • Motor housing . . . . . . . . . . .Glass reinforced thermoplastic
  • Volute . . . . . . . . . . . . . . . . . .Glass reinforced thermoplastic
    • (SPF33, SPF5O & SSPF50)
    • Cast Iron (CDU790, CDU790HH,
    • CDU800, CDU980 & SSCDU800)
  • Shaft . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Low Carbon Steel
  • Seals . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Buna N
  • Discharge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11/2″ NPT
  • Motor Cover . . . . . . . . . . . . .Glass reinforced thermoplastic

REMINDER: Keep your dated proof of purchase for warranty purposes! Attach it to this manual or file it for safekeeping.

Limited Warranty

For (One year on Models SPF33, SPF50) (Three years on Models FLS790, FLS800, SSPF50, SSCDU800, CDU790, CDU790HH & CDU800) from the date of purchase for the original purchaser, Wayne Water Systems (“Wayne”) will repair or replace, at its option, for the original purchaser any part or parts of its Sump Pumps or Water Pumps (“Product”) found upon examination by Wayne to be defective in materials or workmanship. Please call Wayne (800-237-0987) for instructions or see your dealer. Be prepared to provide the model and serial number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser.

LIMITED LIFETIME WARRANTY (MODEL CDU980)

  • Wayne will repair or replace, at its option, one time only, for the original purchaser any part or parts of its Sump pump found upon examination by Wayne to be defective in materials or workmanship. This warranty does not cover normal wear and tear during the life
    of the product.

  • This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, or failure to operate in accordance with Wayne’s written instructions.

  • THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO (ONE YEAR ON MODELS SPF33, SPF50 & SSPF50) (THREE YEARS ON MODELS SSCDU800, CDU790, CDU790HH AND CDU800) (LIFETIME ON MODEL CDU980) FROM THE DATE OF PURCHASE. THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSEQUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED.

  • Some states do not allow limitations on how long an implied warranty lasts, or do not allow the exclusions or limitations of incidental or consequential damages, so the above limitations might not apply to you. This limited warranty gives you specific legal rights, and you may also have other legal rights which vary from state to state.

  • In no event, whether as a result of breach of contract warranty, tort (including negligence) or otherwise, shall Wayne or its suppliers be liable for any special, consequential, incidental or penal damages including, but not limited to loss of profit or revenues, loss of use of the products or any associated equipment, damage to associated equipment, cost of capital, cost of substitute products, facilities, services or replacement power, downtime costs, or claims of buyer’s customers for such damages.

  • You MUST retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you MUST send a copy of the purchase receipt along with the material or correspondence.

  • Please call Wayne at (800-237-0987) for return authorization and instructions.

  • ATTENTION LIFETIME WARRANTY CLAIMS: Do not return the product to the store. For warranty claims or replacement parts please contact us at 1-800-237-0987.

  • DO NOT MAIL THIS FORM TO WAYNE. Use this form only to maintain your records.

  • MODEL NO.___

  • SERIAL NO.__

  • INSTALLATION DATE_____

  • ATTACH YOUR RECEIPT HERE

www.waynepumps.com
© 2006 Wayne Water Systems
For parts, product & service information
visit www.waynepumps.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals