MyWeigh R1 Ultra Ship Scale Digital Instruction Manual
- June 16, 2024
- MyWeigh
Table of Contents
MyWeigh R1 Ultra Ship Scale Digital
ULTRASHIP®-R1 User Manual
Welcome
Thank you for purchasing the My Weigh® UltraShip®-R1 digital scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service. For more information please visit www.myweigh.com.
Never load the scale with more than the maximal capacity. Although the UltraShip®-R1 is designed to be extremely durable with extra overload protection built into the case, overloading will permanently damage it! Avoid any exposure to extreme heat or cold, your scale works better when operated at normal room temperature. Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air currents and/or proximity to other electronic equipment can all hurt the reliability and accuracy of your scale. Handle with care. Gently shock and are sometimes destroyed. This happens with all digital scales. We design our scales to be as resistant to shock or drops as possible, however, there is no way for us to protect 100% against load cell or sensor damage. Failure to follow these instructions will void your warranty.
Always allow the scale to acclimate to normal room temperature for at least one hour before use. Give your scale sufficient warm-up time. Usually, 30-60 seconds before calibration to give the internal components a chance to stabilize.
Batteries
Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers and 60% of them are battery-related problems. This sounds silly but it’s true! A scale will perform poorly when it has low batteries. Use good quality batteries & replace them often ( Remove the batteries if you plan to store the scale for longer than 14 days). If your scale simply won’t turn on while on battery power, it is often caused by loose battery connections. Battery prongs (terminals) are made of metal and they have to be in contact with the batteries. You can use a paperclip to slightly bend the battery prongs to have a better connection. Some poorly designed batteries have recessed or partially obstructed battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead of the metal of the battery terminal.
Battery Installation
- Press and lift open the battery cover located at the bottom of the unit.
- Insert the batteries and make sure the polarity is correct (+) and (-).
- Close the battery cover until it clicks shut.
- Note: It is time to replace the battery if the display shows “Lo” when powered on and then it will turn off automatically.
Operation Instructions
Weighing Procedures
- Press [ON/OFF] to turn on the scale. When the power is turned on, the scale will countdown for a few seconds and “0” will appear on the display.
- Select the weighing unit with the [UNIT] key. Press [UNIT] to select a weighing unit e.g., kg, oz, lb, lb:oz. Once the unit has been selected, the selected unit will be displayed next to the weight value.
- Start weighing. Verify the reading is “0”. Place objects on the weighing platform to weigh. When the reading becomes stable, the stable indicator is displayed.
Features
- Overload Indicator: When the display shows “O _ LD”, this indicates an overload. Remove excessive load immediately. Remember: you can permanently damage the scale and void your warranty by overloading it!
- Negative Value: Any tared value will be displayed as a negative number once all weight is removed, press [TARE / ZERO] to re-zero the scale.
- Auto Off/ Backlight Setting: An auto shut-off feature is provided to conserve battery power. The scale will automatically turn off after 2 minutes of inactivity. To adjust the auto-off & backlight settings follow these instructions:
- Press and hold [HOLD] and power on the scale with [ON/OFF], then release both keys.
- The display will now show “oFF 0” (auto-off disabled), “oFF 1” (automatic turn off after about 2 minutes – Default setting), or oFF 2” (automatic turn off after about 5 minutes. Press [HOLD] to toggle and [TARE/ZERO] to confirm and enter backlight settings.
- The display will now show “BL 0” (backlight disabled), “BL 1” (backlight always on – Default setting), or “BL 2” (backlight automatically turns on when the scale is in use). Press [HOLD] to toggle the settings.
- Press [TARE/ZERO] to confirm your selection. The scale will now return to normal weighing mode.
Removable Display Operation
- Push the release button and slide the panel to the right.
- Pull the panel towards you.
- The display is separated and ready to use.
FAQ
- What should I do if my scale displays ‘Lo’?
- It indicates that the battery is low and needs to be replaced.
- How do I perform a calibration on the UltraShip®-R1?
- Follow the calibration instructions in the Operation Instructions section of this manual.
- Can I use the scale immediately after turning it on?
- Allow the scale to acclimate to room temperature for at least one hour before use and 30-60 seconds for internal components to stabilize.
For more detailed information and troubleshooting, please refer to the user manual or visit www.myweigh.com.
CAPACITIES
- 0-1kg X lg/ 1-18kg X 5g
- 0-21b x 0.1oz/ 2-401b x0.2oz
- 0-1kg x 2g /1-27kg x 5g
- 0-21b x 0.1oz/ 2-601b x0.2oz
- 0-2kg X Sg / 2-36kg X 10g
- 0-41b x 0.2oz / 4-8D lb x 0.5oz
Thank you for purchasing the My Weigh• UltraShip”- R1 digital scale. Please
read all operating instructions carefully before use. This electronic scale is
a precision instrument. With normal care and proper treatment, it will provide
years of reliable service. For more information please visit
www.myweigh.com.
Never load the scale with more than the maximal capacity. Although the
UltraShip”-R1 is designed to be extremely durable with extra overload
protection built into the case, overloading will permanently damage it! Avoid
any exposure to extreme heat or cold, your scale works better when operated at
normal room temperature. Keep your scale in a clean environment. Dust, dirt,
moisture, vibration, air currents and/or proximity to other electronic
equipment can all harm the reliability and accuracy of your scale. Handle with
care. Gently apply all items to be weighed onto the tray top. Avoid shaking,
dropping or otherwise shocking the scale. Scales are delicate instruments and
unlike cellular phones, scales have delicate sensors that determine how much
an item weighs. If you drop or shock your scale, these sensors”feel” the shock
and are sometimes destroyed. This happens with all digital scales. We design
our scales to be as resistant to shock or drops as possible, however, there is
no way for us to protect 100% against load cell or sensor damage.
Failure to follow these instructions will void your warranty.
Always allow the scale to acclimate to normal room temperature for at least
one hour before use. Give your scale sufficient warm-up time.
Usually, 30-60 seconds before calibration to give the internal components a
chance to stabilize.
BATTERIES
Low Batteries & bad battery connections are the #1 cause of scale malfunction and inaccuracy! We test all of our scale returns from consumers and 60% of them are battery-related problems. This sounds silly but it’s true! A scale will perform poorly when it has low batteries. Use good quality batteries & replace them often ( Remove the batteries if you plan to store the scale for longer than 14 days). If your scale simply won’t turn on while on battery power, it is often caused by loose battery connections. Battery prongs (terminals) are made of metal and they have to be in contact with the batteries. You can use a paperclip to slightly bend the battery prongs to have a better connection. Some poorly designed batteries have recessed or partially obstructed battery terminals. This may cause your prongs to be touching the plastic housing of the battery instead of the metal of the battery terminal.
Battery installation
- Press and lift open the battery cover located atthe bottom of the unit.
- Insert the batteries and make sure the polarity is correct(+) and ( – ).
- Close the battery cover until it clicks shut.
Note: It is time to replace the battery if the dispaly shows”Lo” when powered on and then it will turn off automatically.
OPERATION INSTRUCTIONS
Weighing Procedures
-
Press [ ] to turn on the scale. When the power is turned on, the scale will countdown for a few seconds and “O” will appear on the display.
-
Select the weighing unit with the [UNIT] key. Press [UNIT] to select a weighing unit g, kg, oz, lb, lb: oz.
Once the unit has been selected, the selected unit will be displayed next to the weight value. -
Start weighing
Verify the reading is “O”. Place objects on the weighing platfonn to weigh. When the reading becomes stable, the stable indicator is displayed.
TARE
Tare can be used to eliminate the weight value of an empty container. Place an
empty container on the scale and press [TARE/ZERO]. Then place the items to be
weighed in the container. NOTE: When all weight is removed from the weighing
tray, the tared value of a container will be displayed as a negative number.
Press [TARE/ZERO] again to return the scale to zero.
CALIBRATION
Calibration may be required when the scale is first set up for use, or if the scale is moved to a different altitude or new location. This is necessary because the weight of a mass in one location is not necessarily the same in another location. Also, with time and use, mechanical deviations can occur.
- Turn the scale OFF and place it on a flat, very stable surface.
- Press and hold both [UNIT] and [ ] to turn on the scale and then release the keys, wait for the display to show”CL.xx”(xx number is the required calibration weight), you can press the [UNIT] key to change the calibration unit between “Lb” and “kg”.
- Press the [HOLD] key to change the value of ten digits, press the [TARE/ZERO] key to change the value of the unit digit, and then press the [ ] key to confirm the calibration weight. The display will flash”CL.xx~ If the required weight is too small or over the range, it will display”Err.
- Place the calibration weight(s) needed on the center of the tray, then press [TARE/ZERO]. The display will show”CAI.’; and then the display will show”PASS~ Calibration is complete. After a few seconds, the scale will return to normal weighing mode. Remove the weight from the tray and turn the scale Off.
FEATURES
Overload Indicator
When the display shows” O_LD: this indicates an overload. Remove excessive
load immediately.
Remember: you can permanently damage the scale and void your warranty by
overloading it!
Negative Value
Any tared value will be displayed as a negative number once all weight is
removed, press [TARE/ ZERO] to re-zero the scale.
Auto Off/ Baddight Setting
An auto shut-off feature is provided to conserve battery power. The scale will
automatically turn off after 2 minutes of inactivity.
To adjust the auto-off & backlight settings follow these instructions:
- Press and hold [HOLD] and power on the scale with [ ], then release both keys.
- The display will now show”oFF O” (auto-off disabled), “oFF 1″ (automatic turn off after about 2 minutes – Default setting), or oFF 2” (automatic turn off after about 5 minutes. Press [HOLD] to toggle and [TARE/ZERO] to confirm and enter backlight settings.
- The display will now show”BL O” (backlight disabled), “BL 1″ (backlight always on – Default setting), or”BL 2” (backlight automatically turns on when the scale is in use). Press [HOLD] to toggle the settings.
- Press [TARE/ZERO] to confirm your selection. The scale will now return to normal weighing mode.
Hold
Press the [HOLD] to hold the current weight reading, and press [HOLD]
again to cancel.
REMOVABLE DISPLAY OPERATION
- Push the release button and slide the panel to the right.
- Pull the panel towards you.
- The display is separated and ready to use.
DISPLAY SYMBOLS
SPECIFICATIONS
- Units: kg, g, Ib: oz, lb
- Auto-OFF: 0-5 minutes
- Scale dimension: 228mm x 205mm x 71mm
- Tray dimension: 188mm x 178mm x 9mm
- Scale weight: 950g
- Operating temperature: Optimum 10-40°C (50-104°F)
- Power Source: 6 x AA Batteries – Adapter 5V-9V/100mA
- Tare Range: Up to scales maximum capacity