MyWeigh STEELE Kitchen Scale User Manual
- June 12, 2024
- MyWeigh
Table of Contents
MyWeigh STEELE Kitchen Scale
USER MANUAL
Thank you for purchasing the My Weigh® STEELE kitchen scale. Please read all operating instructions carefully before use. This electronic scale is a precision instrument. With normal care and proper treatment, it will provide years of reliable service. For more information please visit www.myweigh.com. Never load the scale with more than the maximal capacity. Although the My Weigh® STEELE is designed to be extremely durable with extra overload protection built into the case, overloading will permanently damage it! Avoid any exposure to extreme heat or cold, your scale works better when operated at normal room temperature. Keep your scale in a clean environment. Dust, dirt, moisture, vibration, air currents and/or a close proximity to other electronic equipment can all cause an adverse effect on the reliability and accuracy of your scale. Handle with care. Gently place all items to be weighed onto the tray top. Avoid shaking, dropping or otherwise shocking the scale. Scales are delicate instruments and unlike cellular phones, scales have delicate sensors that determine how much an item weighs. If you drop or shock your scale, these sensors “feel” the shock and are sometimes destroyed. This happens with all digital scales. We design our scales to be as resistant to shock or drops as possible, however there is no way for us to protect 100% against load cell or sensor damage. Failure to follow these instructions will void vour warranty. Always allow the scale to acclimate to normal room temperature for at least one hour before use. Give your scale sufficient warm up time. Usually 30-60 seconds before calibration to give the internal components a chance to stabilize.
Batteries
Low Batteries & bad battery connections are the #1 cause of scale malfunction
and inaccuracy! We test all of our scale returns from consumers and 60% of
them are battery related problems. This sounds silly but it’s true! A scale
will perform poorly when it has low batteries. Use good quality batteries &
replace them often ( Remove the batteries if you plan to store the scale for
longer then 14 days). We include good quality batteries with all of our scales
but they can run low in storage. If your scale simply won’t turn on while on
battery power, it is often caused by loose battery connections. Battery prongs
(terminals) are made of metal and they have to be in contact with the
batteries. Some poorly designed batteries have recessed or partially
obstructed battery terminals. This may cause your prongs to be touching the
plastic housing of the battery instead of the metal of the battery terminal.
Battery installation
- Press and lift open the battery cover located at the bottom of the unit.
- Insert the batteries and make sure the polarity is correct (+) and (-).
- Close the battery cover until it clicks shut.
OPERATION INSTRUCTIONS
Weighing Procedures
- Press [ON/OFF] to turn on the scale, wait for a few seconds and “O” will appear on the display.
- Press [UNIT] to select a weighing unit g, kg, oz, lb.
- Start weighing. Verify the reading is “O”. Place objects on the weighing platform to weigh.
Tare
Tare can be used for eliminating the weight value of an empty container. Place
an empty container on the scale and press [Z/T]. Then place the items to
be weighed in the container. NOTE: When all weight is removed from the
weighing tray, the tared value of a container will be displayed as a negative
number. Press [Z/T] again to return the scale to zero.
FEATURES
Timer
It is possible to set the timer for a maximum of 99 minutes and 59 seconds:
- Press [T-SET] to start the timer setting.
- Use the [UNIT] and [Z/T] keys to set the digit value and [T-SET] to go to the next digit.
- After the last digit is set, press [T-SET] again to start the timer.
- When the timer gets to “00.00” an alarm will beep 60 times and the scale will shut off automatically.
To cancel the timer before it ends, press any key except [ON/OFF] or the scale will turn off.
Thermometer
Current temperature is shown on the top left corner of the LCD. This ranges
from 0°C ~ 40°C or from 32°F ~ 104 °F. Users can select between Celsius and
Fahrenheit on the scale.
Extra Large Mixing Bowl
The STEELE is provided with a stainless steel bowl. This bowl is large to
accommodate usual food items and is washable with water or in a dishwasher.
Negative Value
Any tared value will be displayed as a negative number once all weight is
removed, press [Z/T] to re-zero the scale.
Auto-Off
An auto shut off feature is provided to conserve battery power. The unit will
automatically turn off after 2 minutes of inactivity.
Overload Indicator
When the display shows “Err”, this indicates an overload. Remove excessive
load immediately. Remember: you can permanently damage the scale and void your
warranty by overloading it!
Power Up Segment Test
When first turning the unit on, the scale will run a quick diagnostic and it
will display a countdown. This display will remain for a few seconds and then
reset to zero.
Low Battery Indicator
If the display shows the low battery symbol, it indicates low batteries. The
batteries needs to be replaced for the scale to function properly.
KEYPAD FUNCTIONS
SÍMBOLOS DISPLAY
SPECIFICATIONS
Capacity| 5kgx 1g| Units| g/kg, oz/lb
Auto-Off| 2 min.
Scale Dimension| 190mm x 190mm x 50mm
Tray Dimension| 0117mm
Scale Weight| 387g
Operating Temperature| Optimum: 10~40°( (50~104°F)
Power Source| 2 x AAA -Batteries
Tare Range| Up to the scale’s maximum capacity