sunlite 85526-SU Round LED Commercial Outdoor Fixture Instruction Manual

June 16, 2024
sunlite

sunlite 85526-SU Round LED Commercial Outdoor Fixture

Introduction

Please read and understand this entire manual before attempting to assemble, operate or install the product.

WARNING: Avoid fire or electric shock. If any part is missing or damaged, do not attempt to assemble, install, or operate this fixture. This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Min 75″C supply conductor.
CAUTION: Turn off the power at fuse or circuit breaker box before installation and maintenance to avoid electric shock.Before installing the fixture, ensure that all parts are present and same as the· part list. Can not use the electric generator to test this lamp, Proper earth grounding is required to ensure safety. Mal<e the fixture facing downward vertically after installation.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful inferences, and (2) this device must accept any inference received, including that may cause undesired operation.
Retain these instructions for future maintenance reference.

Installation

STEP 1. Rotate the lamp body 90 degree to make sure light facing downward. (Fig 1)
Installation
STEP 2. Tighten screws on both sides of the bracket to fix the lamp body. Installation is finished when the lamp body is fixed without shaking. (Fig 2)
Installation
STEP 3. Loosen the screws by wrench. (Fig 3)
Installation
STEP 4. Connect the lamp to utility power according to the wiring standard, and make sure there is good joint protective measures. (Fig 4)
Installation
STEP 5. Install the lamp to the pole, adjust the viewing angle, then tighten the screw. (Fig 5)
Installation

Wiring Diagram & Mounting Condition Diagram

Wiring Diagram & Mounting Condition Diagram

Instruction for Photocell

When the photocell function is required, photocell should be installed on the back of lamp, otherwise please install the shorting cap.

Field-Adjustable CCT

The end users may adjust the color temperature by the switch buttons integrated into the lamp. Press back to open and get the desired color temperature

Structure of Motion Sensor

Structure of Motion Sensor

Setting: By selecting the com.bi nation on the DIP switch, sensor data can be precisely set for each specific application

DETECTION AREA

Detection area can be reduced by selecting the combination on the DIP switches to fit precisely each app li cation.
Factory Setting: I

| | 1| 2|
---|---|---|---|---
I| ON| ON| 100%
II| ON| –| 75%
III| –| ON| 50%
IV| –| –| 25%

STAND-BY PERIOD

Refers to the time period the lamp remains at a low light level before it completely switches off in the long absence of people. When set to Disable mode, the low light is maintained until motion is detected.
Factory Setting: I

| | 6| 7| 8|
---|---|---|---|---|---
I| ON| ON| ON| OS
II| –| ON| ON| 5S
III| ON| –| ON| 5min
IV| –| –| ON| 10min
V| ON| ON| –| 30min
VI| –| ON| –| 1h
VII| –| –| –| +00

DAYLIGHT SENSOR

The sensor can be set to only allow the lamp to illuminate below a defined ambient brightness threshold. When set to Disable mode, the daylight sensor will switch on the lamp when motion is detected regardless of ambient light level.100 lu x, 100lux, 50lux:
twilight operation, 10 lux, 5lux: darkness operation only. Note that daylight sensor is active only when lamp totally switches off.
Factory Setting: VII

| | 3| 4| 5| 6|
---|---|---|---|---|---|---
I| ON| ON| ON| ON| 5 lux
II| –| ON| ON| ON| 15 lux
III| ON| –| ON| ON| 30 lux
IV| –| –| ON| ON| 50 lux
V| ON| ON| –| ON| 100 lux
VI| ON| ON| ON| –| 150 lux
VII| –| –| –| –| Disable

HOLD TIME

Refers to the time period the lamp remains at 100% illumination after no motion detected.
Factory Setting: VI

| | 3| 4| 5|
---|---|---|---|---|---
I| ON| ON| ON| 5s
II| –| ON| ON| 30s
III| ON| –| ON| 90s
IV| –| –| ON| 3min
V| ON| ON| –| 20min
VI| –| –| –| +00

STAND-BY DIMMING LEVEL

The low light level you would like to have after the hold time in the long absence of people.
Factory Setting: I

| | | |
---|---|---|---|---
I| ON| ON| 50%
II| –| ON| 30%
III| ON| –| 20%
IV| –| –| 10%

CUSTOMER SUPPORT

Sunshine Lighting Company
744 Clinton Street Brooklyn, NY 11231, USA
T. 718.768.7000
F. 718.768.0970
www.sunlite.comSymbolLogo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

sunlite User Manuals

Related Manuals