BW Technologies BWC2-M Clip Single Gas CO Monitor User Guide

June 16, 2024
BW Technologies

BWC2-M Clip Single
Gas CO Monitor
User Guide

BWC2-M Clip Single Gas CO Monitor

BW Technologies BWC2-M Galbert Extreme CO (CO)

The BWC2-M BW Clip Single Gas CO Monitor is a two-year maintenance gas detector that helps keep industrial workers safe in hazardous environments. This single gas monitor keeps an accurate log of the 35 most recent gas detection events to ensure easy, maintenance-free record tracking. It is also portable and compatible with the MicroDock III and the InteliDoX instrument management systems.

Meets or Exceeds Class I, Div. 1, Gr. A, B, C, D, Class I, Zone 0, Group IIC, CE 0539 II 1G Ex ia IIC T4 Ga IP66/67 DEMKO 14 ATEX 1356

Features and Specs:

  • Maintenance-free: no sensor or battery changes necessary
  • Compact, lightweight design with one-button operation
  • Designed for a range of harsh environments and extreme temperatures
  • Hibernation mode with case accessory or IntelliDoX
  • Automated self-test of battery, sensor and electronics
  • Default Alarm Setpoints at 35 ppm and 200 ppm
  • Alarm Setpoint range of 5 ppm to 200 ppm
  • Detector measuring range of 0-300 ppm carbon monoxide
  • Wide-angle flash, which alerts simultaneously with audible and vibrating alarm
  • Automatic logging of the 35 most recent gas events and bump test results
  • Compatible with MicroDock II and Fleet Manager II software
  • Ip 66/67- can be submerged up to 1 meter
  • Affordable, with low cost of ownership

BW Clip Specifications:

  • Weight: 0.6 lbs.
  • Temperature: -40 to 122°F
  • Humidity: 5 – 95 percent RH (non-condensing)
  • Alarms: Visual, vibrating, and audible
  • Typical Battery Life: Two years

Honeywell CLIPHB-CASE BW Clip Hibernation Case (Optional)

CLIPHB-CASE Features:

  • Alarm type: Audible Visual Vibrating
  • Battery Run Time: 2hours
  • The BW Clip Series of single-gas detectors provides up to three years maintenance
  • Free operation: Just turn on the device and it runs continuously
  • No need for calibration sensor replacement battery replacement or battery charging.
  • For Use With: BW Clip
  • Gas Type: H2S CO O2 LEL SO2
  • Maximum Temperature: 50degree Celsius
  • Minimum Temperature: -40degree Celsius

Gas Meters are not eligible for returns or exchanges

Documents / Resources

| BW Technologies BWC2-M Clip Single Gas CO Monitor [pdf] User Guide
BWC2-M Clip Single Gas CO Monitor, BWC2-M, Clip Single Gas CO Monitor, Single Gas CO Monitor, Gas CO Monitor, CO Monitor
---|---

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals