Lenovo 4XC7A08279 Series 32Gb Fibre Channel Adapters Think System Logic Instruction Manual

June 16, 2024
Lenovo

ThinkSystem QLogic 2770 Series 32Gb Fibre Channel Adapters
Product Guide

4XC7A08279 Series 32Gb Fibre Channel Adapters Think System

The QLogic 2770 (QL2770) Series 32 Gb Fibre Channel (FC) Host Bus Adapters (HBAs) are Generation 6 (Gen 6) FC adapters for Lenovo ThinkSystem servers. These adapters offer industry leading native FC performance with extremely low CPU usage with full hardware offloads. With performance of up to 1 million I/O operations per second (IOPS) per port, these adapters can be used to support all-flash arrays (AFAs) -Fibre hannel storage systems comprised completely of high-speed solid-state drives.
Powerful management tools automate and simplify SAN provisioning to help reduce cost and complexity, while the unmatched 32 Gbps performance eliminates potential I/O bottlenecks in today’s powerful multiprocessor, multicore servers.
The QLogic QLE2772 2-port 32 Gb Fibre Channel HBA is shown in the following figure. Lenovo 4XC7A08279 Series 32Gb Fibre Channel Adapters Think System
Logic Did you know?
QLogic 2770 Series Adapters incorporate a hardware-based Root of Trust that prevents malicious firmware from hijacking the adapters. The 2770 Series RoT enables both integrity and authenticity during adapter firmware updates by both validating firmware embedded signatures with hardware embedded keys to ensure that only validated firmware executes, and protecting firmware updates that are applied over public networks.
Click here to check for updates
ThinkSystem QLogic 2770 Series 32Gb Fibre Channel Adapters 1

Part numbers

The following table lists the ordering information for the QLogic 2770 Series 32Gb Fibre Channel HBAs.
Table 1. Part numbers and feature codes

Part number Feature code Description
4XC7A08279 BA1G ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel

Adapter
4XC7A08276| BA1F| ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel Adapter

The part numbers for the QLogic 2770 Series HBAs include the following items:

  • An FC HBA adapter with one or two 32 Gb FC SW SFP+ transceivers installed
  • 3U (full height) and 2U (low-profile) adapter brackets
  • Publications flyer

The ThinkSystem QLogic QLE2770 1-Port HBA is shown in the following figure.Lenovo 4XC7A08279 Series 32Gb Fibre Channel Adapters Think System
Logic - ThinkSystem QLogic Fiber optic cables
The following table lists the fiber optic cables that are available from Lenovo.
Table 2. Fiber optic cables

Part number I Feature code Description

LC-LC 0M3 MMF Fiber Optic Cables
00MN499| ASR5| Lenovo 0.5m LC-LC OM3 MMF Cable
00MN502| ASR6| Lenovo 1m LC-LC OM3 MMF Cable
OOMN505| ASR7| Lenovo 3m LC-LC OM3 MMF Cable
00MN508| ASR8| Lenovo 5m LC-LC OM3 MMF Cable
OOMN511| ASR9| Lenovo 10m LC-LC 0M3 MMF Cable
00MN514| ASRA| Lenovo 15m LC-LC OM3 MMF Cable
00MN517| ASRB| Lenovo 25m LC-LC 0M3 MMF Cable
00MN520| ASRC| Lenovo 30m LC-LC 0M3 MMF Cable

Key features

The QL2770 32Gb Fibre Channel HBAs have the following features:

  • Maximum performance with up to 1 million input/output operations per second (IOPS) per port (2 million IOPS in a dual-port adapter) to support larger server virtualization deployments and scalable cloud initiatives, and performance to match new multicore processors, SSDs/flash storage, and faster server host bus architectures.
  • Independent function, transmit and receive buffers, an on-chip CPU, DMA channels, and a firmware image for each port enable complete port-level isolation, prevent errors and firmware crashes from propagating across all ports, and provide predictable and scalable performance across all ports.
  • Support for NVMe over Fibre Channel (FC-NVMe). The adapters support low-latency access to scale out NVMe with full support for the FC-NVMe protocol. The adapters can simultaneously support FC-NVMe and FCP-SCSI storage traffic on the same physical port, enabling customers to migrate to NVMe at their own pace.
  • Support forward error correction (FEC) to enhance reliability of transmission and thereby performance.
  • Industry-standard class-specific control (CS_CTL)-based frame prioritization Quality of Service (QoS) helps alleviate network congestion by prioritizing traffic for time-sensitive mission critical workloads for optimized performance.
  • T10-PI data integrity with high performance offload provides end-to-end data corruption protection.
  • Support for Message Signaled Interrupts eXtended (MSI-X) improves host utilization and enhances application performance.
  • Fabric-assigned port worldwide name (FA-WWN) and fabric-based boot LUN discovery (F-BLD) pre- provisioning services allow servers to be quickly deployed, replaced, and moved across the SAN; the creation of zones, LUNs, and other services can be completed before the servers arrive on site.
  • Using the Brocade ClearLink diagnostic port (D_Port) available on the Brocade Gen 5 switches, administrators can quickly run automated diagnostic tests to assess the health of links and fabric components.
  • Read diagnostic parameters (RDP) feature provides detailed port, media, and optics diagnostics to easily discover and diagnose link-related errors and degrading conditions on any N_Port-to-F_Port link.
  • Link cable beacon (LCB) enables administrators to visually identify both ends of a physical link by flashing HBA’s LEDs, simplifying identification of the connection peers within server racks without tracing the cable.
  • Single-pane-of-glass management across generations of QLogic FC adapters with QLogic QConvergeConsole (QCC).
  • Deployment flexibility and integration with third-party management tools, including the VMware vCenter and Brocade Network Advisor.
  • Support for 32 Gb, 16 Gb and 8 Gb FC devices.
  • Comprehensive virtualization capabilities with support for N_Port ID Virtualization (NPIV).
  • A common driver model allows a single driver to support all QLogic HBAs on a given OS.
  • Reduce the number of cards, cables, and PCIe slots required.
  • Exceptional performance per watt and price/performance ratios.
  • Backward compatibility with existing 8Gb FC and 16Gb FC infrastructure, leveraging existing SAN investments.
  • Allow application of SAN best practices, tools, and processes with virtual server deployments.
  • Ensure data availability and data integrity.
  • Boot from SAN capability reduces the system management costs and increases uptime.

Note: Legacy boot (Fast!UTIL) is not supported on these adapters.

Technical specifications

  • The QLogic 2770 Series 32Gb Fibre Channel HBAs have the following specifications:

  • Based on the QLogic QLE2770 (single port) and QLE2772 (dual port) adapters

  • Host interface: PCIe 4.0 x8

  • Ports: Single-port and dual-port SFP+ based adapters

  • Link speed: Support for 32 Gb, 16 Gb and 8 Gb link speeds, which are automatically negotiated

  • Data rate: 28.05 (3200 MBps), 14.025 Gbps (1600 MBps), and 8.5 Gbps (800 MBps) autosensing (per port), with full duplex

  • Performance: Up to 2,000,000 IOPS (up to 1,000,000 IOPS per port)

  • Fibre Channel standards compliance:
    SCSI Fibre Channel Protocol-4 (FCP-4)
    Fibre Channel Tape (FC-TAPE) Profile
    Fibre Channel Generation Services-8 (FC-GS-8)
    Fibre Channel-Physical Interface-5 (FC-PI5)
    Fibre Channel-Physical Interface-6 (FC-PI6)
    Fibre Channel Link Services 4 (FC-LS-4)
    Fibre Channel Framing and Signalling-4 (FC-FS-4)
    Fibre Channel-NVMe (FC-NVMe)

  • Topology: Point-to-point and switched fabric

  • Hot-pluggable 32 Gbps Fibre Channel SFP+ short wave optical transceivers (850 nm) with LC connectors (included with the adapters). Note: Other transceivers are not supported.

  • Distance support:
    Operating at 32 Gbps:
    Up to 20 m on 50/125 µm OM2 Multi-Mode Fiber (MMF)
    Up to 70 m on 50/125 µm OM3 MMF
    Up to 100 m on 50/125 µm OM4 MMF

  • Operating at 16 Gbps:
    Up to 35 m on 50/125 µm OM2 Multi-Mode Fiber (MMF)
    Up to 100 m on 50/125 µm OM3 MMF
    Up to 125 m on 50/125 µm OM4 MMF

  • Operating at 8 Gbps:
    Up to 50 m on 50/125 µm OM2 MMF
    Up to 150 m on 50/125 µm OM3 MMF
    Up to 190 m on 50/125 µm OM4 MMF

  • Management software:
    The QLogic unified management application, QLogic QConvergeConsole (QCC), provides single-pane-of-glass management across generations of QLogic FC adapters.
    QLogic supports all major APIs for deployment flexibility and integration with third-party management tools, including the VMware vCenter and Brocade Network Advisor.

Server support

The following tables list the ThinkSystem servers that are compatible.
Table 3. Server support (Part 1 of 3)Lenovo 4XC7A08279 Series 32Gb Fibre
Channel Adapters Think System Logic - table 2Table 4. Server support (Part 2 of 3)Lenovo
4XC7A08279 Series 32Gb Fibre Channel Adapters Think System Logic -
tableTable 5. Server support (Part 3 of 3)Lenovo 4XC7A08279 Series 32Gb Fibre Channel
Adapters Think System Logic - table 1

Operating system support

The following tables list the supported operating systems for each part number:

  • ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel Adapter, 4XC7A08279
  • ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel Adapter, 4XC7A08276

Tip: These tables are automatically generated based on data from Lenovo ServerProven.
Table 6. Operating system support for ThinkSystem QLogic QLE2770 32Gb 1-Port PCIe Fibre Channel Adapter, 4XC7A08279Lenovo 4XC7A08279 Series 32Gb Fibre
Channel Adapters Think System Logic - table 3Lenovo 4XC7A08279 Series 32Gb Fibre Channel
Adapters Think System Logic - table 4 For limitation, please refer Support Tip 104278
The OS is not supported with EPYC 7003 processors.
Table 7. Operating system support for ThinkSystem QLogic QLE2772 32Gb 2-Port PCIe Fibre Channel
Adapter, 4XC7A08276
Lenovo 4XC7A08279 Series 32Gb Fibre Channel Adapters Think System Logic -
table 5Lenovo
4XC7A08279 Series 32Gb Fibre Channel Adapters Think System Logic - table
6 For limitation, please refer Support Tip 104278
The OS is not supported with EPYC 7003 processors.
SAN switches
Lenovo offers the ThinkSystem DB Series of Fibre Channel SAN switches for high-performance storage expansion. See the DB Series product guides for models and configuration options:

Warranty
The adapters carry a one-year limited warranty. When installed in a supported server, the adapters assume the server’s base warranty and any Lenovo Services warranty upgrade.
Physical specifications
The adapters have the following dimensions (approximate):

  • Low profile form factor card
  • 168 mm x 69 mm (6.60 in. x 2.7 in.)
  • Standard (3U) and low-profile (2U) brackets included

Operating environment
The adapters are supported in the following environment:

  • Temperature:
    Operating: 0 – 55 °C (32 – 131 °F)
    Storage: -20 – 70 °C (-4 – 185 °F)

  • Relative humidity:
    Operating: 10 – 90% (non-condensing)
    Storage: 5 – 95% (non-condensing)

Agency approvals

The adapters conform to the following regulations:

  • Safety:
    UL 60950-1
    CSA C22.2
    TUV EN60950-1
    TUV IEC 60950-1
    CB Certified

  • EMI and EMC (Class A)
    FCC Rules, CFR Title 47, Part 15, Subpart Class A
    Industry Canada, ICES-003: Class A
    EN55032
    EN55024
    EN61000-3-2
    EN61000-3-3
    Japan VCCI: Class A
    New Zealand and Australia AS/NZS: Class A
    Korea KC-RRA Class A
    Taiwan BSMI CNS 13438

Related publications and links
For more information, see the following resources:

Related product families
Product families related to this document are the following:

Notices
Lenovo may not offer the products, services, or features discussed in this document in all countries. Consult your ocal Lenovo representative for information on the products and services currently available in your area. Any reference to a Lenovo product, program, or service is not intended to state or imply that only that Lenovo product, program, or service may be used. Any functionally equivalent product, program, or service that does not infringe any Lenovo intellectual property right may be used instead. However, it is the user’s responsibility to evaluate and verify the operation of any other product, program, or service. Lenovo may have patents or pending patent applications covering subject matter described in this document. The furnishing of this document does not give you any license to these patents. You can send license inquiries, in writing, to:
Lenovo (United States), Inc.
8001 Development Drive
Morrisville, NC 27560
U.S.A.
Attention: Lenovo Director of Licensing
LENOVO PROVIDES THIS PUBLICATION ”AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of express or implied warranties in certain transactions, therefore, this statement may not apply to you. This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes will be incorporated in new editions of the publication. Lenovo may make improvements and/or changes in the product(s) and/or the program(s) described in this publication at any time without notice.
The products described in this document are not intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. The information contained in this document does not affect or change Lenovo product specifications or warranties. Nothing in this document shall operate as an express or implied license or indemnity under the intellectual property rights of Lenovo or third parties. All information contained in this document was obtained in specific environments and is presented as an illustration. The result obtained in other operating environments may vary. Lenovo may use or distribute any of the information you supply in any way it believes appropriate without incurring any obligation to you.
Any references in this publication to non-Lenovo Web sites are provided for convenience only and do not in any anner serve as an endorsement of those Web sites. The materials at those Web sites are not part of the materials for this Lenovo product, and use of those Web sites is at your own risk. Any performance data contained herein was determined in a controlled environment. Therefore, the result obtained in other operating environments may vary significantly. Some measurements may have been made on development-level systems and there is no guarantee that these measurements will be the same on generally available systems. Furthermore, some measurements may have been estimated through extrapolation. Actual results may vary. Users of this document should verify the applicable data for their specific environment.
© Copyright Lenovo 2023. All rights reserved.
This document, LP1307, was created or updated on October 12, 2021.
Send us your comments in one of the following ways:
Use the online Contact us review form found at: https://lenovopress.lenovo.com/LP1307
Send your comments in an e-mail to: comments@lenovopress.com
This document is available online at https://lenovopress.lenovo.com/LP1307.
Trademarks
Lenovo and the Lenovo logo are trademarks or registered trademarks of Lenovo in the United States, other countries, or both. A current list of Lenovo trademarks is available on the Web at https://www.lenovo.com/us/en/legal/copytrade/.
The following terms are trademarks of Lenovo in the United States, other countries, or both:

  • Lenovo® Lenovo
  • Services ServerProven®
  • ThinkSystem®

The following terms are trademarks of other companies:
Intel® is a trademark of Intel Corporation or its subsidiaries.
Linux® is the trademark of Linus Torvalds in the U.S. and other countries.
Microsoft®, Windows Server®, and Windows® are trademarks of Microsoft Corporation in the United States, other countries, or both.
Other company, product, or service names may be trademarks or service marks of others.

ThinkSystem QLogic 2770 Series 32Gb Fibre Channel Adapters

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Lenovo User Manuals

Related Manuals