FRESCA FMC011530-L 15 X 30 Inch Rectangular Recessed Surface Frameless
Medicine Cabinet With LED Light
IMPORTANT SAFETY INSTRUCTIONS
When using an electrical furnishing, basic precautions should always be followed, including the following:
DANGER
READ AND FOLLOW ALL INSTRUCTIONS BEFORE USING THIS CABINET.
WARNING
To reduce the risk of burns, fire, electric shock or injury to persons. Use
this furnishing only for its intended use as described in these instructions.
Do not use attachments not recommended by the manufacturer. Never drop or
insert any object into any opening. Do not use outdoors.
WARNING
Risk of electric shock. Connect this furnishing to a properly grounded circuit
only. See Grounding instructions.
CAUTION
Total/Maximum shelf load 34lbs/15.4kg
GROUNDING INSTRUCTIONS
This product must be connected to a grounded metal, permanent wiring system,
or an equipment-grounding conductor must be run with the circuit conductors
and connected to the equipment-grounding terminal or lead on the product.
WARNING
An Electrical option cabinet must be wired to a 20 Amp GFI (Ground Fault
Interrupter) protected circuit when used in bathrooms and all other locations
required by the National Electric Code.
PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
TOOLS REQUIRED FOR ASSEMBLY
PARTS
DIMENSIONS
- A – Cabinet’s width
- B – Cabinet’s Height
- C – Cabinet’s Depth
NOTE: Determine overall medicine cabinet dimensions. If recessing the medicine cabinet, determine rough-in dimensions.
- ALL DIMENSIONS & SPECIFICATIONS ARE APPROXIMATE AND SUBJECT TO CHANGE WITHOUT NOTICE.
- RISK OF PROPERTY DAMAGE. USE ANCHORS RATED FOR THE LOADED WEIGHT OF THE PRODUCT. REFER TO THE ANCHOR MANUFACTURER’S INSTRUCTIONS.
BEFORE MOUNTING
- Remove Door/s Before mounting your cabinet. Start with unplugging the door from the cabinet.
- While supporting the door release the lever under the hinge arm (See Illustration 2A). Slide the door off the frame.
ELECTRIC CONNECTIONS
ALL WIRING SHOULD BE DONE BY A QUALIFIED LICENCED ELECTRICIAN
WARNING: Shut off power before wiring the cabinet.
WARNING: An Electrical option cabinet must be wired to a 20 Amp GFI
(Ground Fault Interrupter) protected circuit when used in bathrooms and all
other locations required by the National Electric Code.
CAUTION: This product must be connected to a grounded, metal permanent
wiring system or an equipment-grounding conductor must be run with the circuit
conductors and connected to the equipment grounding terminal or lead on the
product.
CAUTION: Requires 120 VAC 20 Amp GFI protected circuit.
RECESS-MOUNT INSTALLATION
- Make a Rough Opening and Frame on all sides. Reference your Cabinet Model Dimensions and Rough in dimensions on Page 3. Make sure the cabinet door has a clearance of at least l” from the top of the faucet and 1″ from the ceiling.
- Electric wiring: Be sure to provide enough wire to make the proper and safe connection to the Field/Power. Place cabinet in rough-in and make sure the cabinet is square, level and plumb. Secure the cabinet with the mounting screws into the framing studs.
- Draw the perimeter of the medicine cabinet on the wall.
- Cut the marked perimeter with the appropriate tool.
- Frame the cutout opening.
- Place and hold the medicine cabinet in the cutout opening.
- Level, then secure the medicine cabinet with the screws through the mounting holes into the framing studs.
- Choose the position for your shelves, then push and twist the snap-in pins into place.
OPTIONAL DOOR ADJUSTMENT
- Doors may need to be adjusted after the initial shipping of the cabinet. The cabinet doors have a three-way adjustment feature.
- Height, side-to-side, level and depth can be adjusted.
- With the hinge slightly closed you can access the middle screw for up/down adjustment.
- With the hinge fully extended you can access the front and back screws. These screws will move the door side to side and in and out.
SURFACE-MOUNT INSTALLATION
- Level and mark the medicine cabinet’s location on the wall from point A to point b
- Attach the bottom Level and mark. bracket (E) to the wall.
- IMPORTANT: Bottom mounting brackets must be attached to furring strip/channel or wall studs.
- Insert the top mounting bracket (D) into the top of the cabinet (A).
- With assistance, rest the medicine cabinet (A) on the bottom mounting bracket (E) and hold it in place.
- You can slide top mounting brackets (D) to the left or right to achieve a desired position.
- IMPORTANT: Top mounting brackets must be attached to furring strip/channel or wall studs.
- Attach the top mounting brackets to the wall using a drill.
- Attach mirrored side panels (B) to the medicine cabinet using a screwdriver and provided screws (J).
- Insert clear snap-in shelf clips (F) into holes on the sides of the cabinet.
- Insert clear plugs (H) into the remaining/unused holes of the cabinet.
- Connect the glass shelves (C) to the cabinet by pushing the side of the shelf in the left or right clip and snapping the shelf down.
- NOTE: For more details on the shelf installation please refer to Page 5, Step 7.
MOUNTING BRACKETS INSTALLATION DETAILS
- Slide top brackets into the channel at the top of the cabinet.
- Make sure the top brackets are locked in the grooves.
- IMPORTANT: Top mounting brackets must be attached to furring strip/channel or wall studs.
- IMPORTANT: Make sure the cabinet is levelled and fully inserted into the grove of the bottom bracket.
- Test the fit of the cabinet before Final assembly.
ELECTRIC WIRING: Be sure to provide enough wire to make the proper and safe connection to the Field/Power (see Page 5 for electrical connection instructions).
FINAL ASSEMBLY
- Slide the doors into place by pinching the end of the hinge
- Plug the door into the cabinet.
- Insert clear snap-in shelf clips (F) into holes on the sides of the cabinet (A).
- Push the side of the shelf (C) in the left or right clip and snap the shelf (C) down.
- Insert clear plugs (H) into the remaining or unused holes, then cover screw heads with the screw cups (G).
How to use Defogger Switch and Dimmer Switch
- Touch the Demoger swit to turn the sling colour off. Press and hold the dimmer switch to dim or brighten the task lights.
- The dimmer switch stores the current light level intensity when switched off and on.
How to set your digital clock
- Press and hold the button on the side of the door for two seconds to enter programming mode When entering programming mode the device will cycle through all 4 number fields once with a 3 second interval in between. Press the side button again while the number is flashing to set the time.
- After the cycle completes the clock resumes normal function within 10 seconds.
Use and Maintenance
CAUTION: Maximum total shelf load 34 LBS
Cabinets and doors are constructed of mirrored glass and aluminium. Use a damp
cloth to clean your cabinet and mirrors. Do not use any abrasive material as
it may damage the surface and finish of the cabinet. A mild detergent may be
used to clean the surfaces of the cabinet. When cleaning spray the cloth, not
the cabinet, mirrors or surrounding surfaces.
CONTACT
- For service and parts information please email:
- general@frescabath.com
- For installation questions contact
- RGM Distribution, Inc.
- 800.514.2143
- FMC 011530-L/011530-R/ 012430/013030/013630/014030/014830
©2018 FRESCA’™ All rights reserved. This material may not be reproduced, displayed, modified or distributed without the express prior written permission of the copyright holder.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>