U-LINE ARI121 Ice Maker Mini Refrigerator User Guide
- June 4, 2024
- U-Line
Table of Contents
U-LINE ARI121 Ice Maker Mini Refrigerator
Safety and Warning
NOTICE
- Please read all instructions before installing, operating, or servicing the appliance.
- Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide:
SAFETY ALERT DEFINITIONS
- Throughout this guide are safety items labeled with a Danger, Warning, or Caution based on the risk type:
- Danger means that failure to follow this safety statement will result in severe personal injury or death.
- Warning means that failure to follow this safety statement could result in serious personal injury or death.
- Caution means that failure to follow this safety statement may result in minor or moderate personal injury, property, or equipment damage.
- Caution: risk of fire, flammable refrigerant and blowing gas used.
GENERAL PRECAUTIONS
- Use this appliance for its intended purpose only and follow these general precautions with those listed throughout this guide.
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience or knowledge, unless they have been given supervision or instruction concerning
- use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with this appliance.
- Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for building-in.
- Please accord to local regulations regarding disposal of the appliance for its flammable refrigerant and blowing gas. Before you scrap the appliance, please remove the doors to prevent child entrapment.
- Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
- Do not use mechanical devices or other means to accelerate the defrosting process, other than those recommended by the manufacturer.
- Do not damage the refrigerating circuit.
- Do not use electrical appliances inside the food/ice storage compartments unless they are of the type recommended by the manufacturer.
- DO NOT use medical devices or other means to accelerate the defrosting process other than those recommended by the manufacturer. DO NOT use an ice pick or other sharp instrument to help speed up defrosting. These
- instruments can puncture the inner lining or damage the cooling unit. DO NOT use any type of heater to defrost. Using a heater to speed up defrosting can cause personal injury and damage to the inner lining.
NOTICE
- Do not lift unit by door handle.
- Never install or operate the unit behind closed doors. Be sure front grille is free of obstruction. Obstructing free airflow can cause the unit to malfunction and will void the warranty.
- Failure to clean the condenser every six months can cause the unit to malfunction. This could void the warranty.
- Allow unit temperature to stabilize for 24 hours before use.
- Do not block any internal fans.
- Use only genuine U-Line replacement parts. Imitation parts can damage the unit, affect its operation or performance and may void the warranty.
- This appliance is intended to be used in household and similar applications such as:
- Staff kitchen areas in shops, offices and other working environments.
- Farm houses and by clients in hotels, motels and other residential type environments.
- Bed and breakfast type environments.
- Catering and similar non-retail applications.
Disposal and Recycling
RISK OF CHILD ENTRAPMENT. Before you throw away your old refrigerator or
freezer, take off the doors and leave shelves in place so children may not
easily climb inside.
If the unit is being removed from service for disposal, check and obey all
federal, state, and local regulations regarding the disposal and recycling of
refrigeration appliances, and follow these steps completely:
- Remove all consumable contents from the unit.
- Unplug the electrical cord from its socket.
- Remove the door(s)/drawer(s).
Environmental Requirements
This model is intended for indoor/interior applications only and is not to be
used in installations that are open/exposed to natural elements.
This unit is designed to operate between 50°F (10°C) and 100°F (38°C). Higher
ambient temperatures may reduce the unit’s ability to reach low temperatures
and/or reduce ice production on applicable models. For best performance, keep
the unit out of direct sunlight and away from heat generating equipment.
In climates where high humidity and dew points are present, condensation may
appear on outside surfaces. This is considered normal. The condensation will
evaporate when the humidity drops.
CAUTION
Damages caused by ambient temperatures of 40°F (4°C) or below are not
covered by the warranty.
Electrical
WARNING
- S HOCK HAZARD — Electrical Grounding Required. Never attempt to repair or perform maintenance on the unit until the electricity has been disconnected.
- Never remove the round grounding prong from the plug and never use a two-prong grounding adapter.
- Altering, cutting or removing power cord, removing power plug, or direct wiring can cause serious injury, fire, loss of property and/or life, and will void the warranty.
- Never use an extension cord to connect power to the unit.
- Always keep your working area dry.
NOTICE
Electrical installation must observe all state and local codes. This unit
requires connection to a grounded (three-prong), polarized receptacle that has
been placed by a qualified electrician. The unit requires a grounded and
polarized 115 VAC, 60 Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit breaker is
recommended. A GFCI (ground fault circuit interrupter) is usually not required
for fixed location appliances and is not recommended for your unit because it
could be prone to nuisance tripping. However, be sure to consult your local
codes. See CUTOUT & PRODUCT DIMENSIONS for recommended receptacle location.
Cutout & Product Dimensions
PREPARE SITE
Your U-Line product has been designed for either freestanding or built-in
installation. When built-in, your unit does not require additional air space
for top, sides, or rear. However, the front grille must NOT be obstructed, and
clearance is required for an electrical connection in the rear.
CAUTION
Unit can NOT be installed behind a closed cabinet door.
CUTOUT DIMENSIONS
PRODUCT DIMENSIONS
REAR
FRONT
TOP
SIDE
Water Hookup
PREPARE PLUMBING
The water valve uses a standard 1/4″ (6.35 mm) compression fitting. U-Line
recommends using accessory water hook up kit – part # 80-54674-00. The kit
includes a 10′ (3 m) braided flexible water supply line and a brass hose
fitting.
CAUTION
Plumbing installation must observe all state and local codes. All water and
drain connections MUST BE made by a licensed/qualified plumbing contractor.
Failure to follow recommendations and instructions may result in damage and/or
harm.
Water Supply Connection
When connecting the water supply, please note the following:
- Before installing the unit and connecting to the cold water supply, review the local plumbing codes.
- The water pressure should be between 20 and 120 psi (138 and 827 kPa).
- The water line MUST have a shut-off valve in the supply line.
- The water line should be looped into 2 coils. This will allow the unit to be removed for cleaning and servicing. Make certain that the tubing is not pinched or damaged during installation.
WARNING
- Connect to potable water supply only.
- Do not use any plastic water supply line. The line is under pressure at all times. Plastic may crack or rupture with age and cause damage to your home.
- Do not use tape or joint compound when attaching a braided flexible water supply line that includes a rubber gasket. The gasket provides an adequate seal – other materials
- could cause blockage of the valve.
- Failure to follow recommendations and instructions may result in damage and/or harm, flooding or void the product warranty.
- Use new hose set. Do not reuse old hose set.
- Turn off water supply and disconnect electrical supply to unit prior to installation.
Use caution when handling back panel. The edges could be sharp.
- Turn off water supply and disconnect electrical supply to product prior to attempting installation.
- . Remove the back panel.
- Locate water valve inlet.
- Break away filler feature in bushing with flat screwdriver.
- Thread water line through back panel hole (with bushing).
- Locate water valve inlet and connect to valve.
- Turn on water supply and check for leaks.
- Reinstall back panel.
- Install retaining clip.
General Installation
LEVELING INFORMATION
NOTICE
Because these units do not have leveling legs, it is extremely important that
they sit on a level surface. If they are not level, the ice mold will not fill
evenly. Use a level to confirm the unit is level. Level should be placed along
top edge and side edge as shown.
INSTALLATION
- Plug in the power/electrical cord.
- Gently push the unit into position. Be careful not to entangle the cord or water line.
- Re-check the leveling, from front to back and side to side. Make any necessary adjustments.
- Remove interior packing material and wipe out the inside of the unit with a clean, water-dampened cloth.
Grille Installation
REMOVING AND INSTALLING GRILLE
WARNING
- Disconnect electric power to the unit before removing the grille.
- When using the unit, the grille must be installed.
Removing the grille
Note: Grille and display are attached. The length of the display wire is
sufficient to allow access to the front base components.
- Disconnect power to the unit.
- Remove the two screws (1).
- Remove grille (2) from unit.
Installing the grille
- Align cabinet and grille holes and secure, but do not over tighten grille screws (1).
- Reconnect power to the unit.
Door Swing
Units have a zero clearance for the door to open 90°, when installed
adjacent to cabinets.
Stainless Steel models require 2-1/8″ (54 mm) door clearance to accommodate
the handle if installed next to a wall.
First Use
Initial startup requires no adjustments. When plugged in, the unit will begin
operating under the factory default settings. If the unit was turned off
during installation, simply press and the unit will immediately switch on. To
turn the unit off, press
NOTICE
Temperature displayed reflects actual temperature inside unit. If the
temperature displayed is different than selected, the unit is progressing
towards the selected temperature. Time to reach set point varies based upon
ambient temperature, temperature of product loaded, door openings, etc. U-Line
recommends allowing the unit to reach set points before loading.
Control Operation
CONTROL FUNCTION GUIDE
This unit is Star-K certified. See www.star-k.org
for more details.
DOOR ALERT NOTIFICATION
When the door is left open for more than 5 minutes:
- A tone will sound for several seconds every minute
- will appear in display
- Close door to silence alert and reset
Ice
ICE MAKER OPERATION
When the ice bucket is full, the ice making mechanism will shut off. However,
the refrigeration system will continue to cool and maintain the ice supply.
NOTICE
Do not place cans or bottles in the ice compartment because they will
freeze.
To turn off ice production: Raise the bin arm into an upright and locked position. The unit will preserve temperature for ice storage.
NOTICE
If not intending to use the ice maker, turn the water supply valve off. It
is also important to raise the bin arm of the ice maker (see above). Failure
to raise the bin arm may result in damage to the water valve.
Certain sounds are normal during the unit’s operation. You may hear the
compressor or fan motor, the water valve, or ice dropping into the ice bucket.
CAUTION
NEVER use an ice pick, knife or other sharp instrument to separate cubes.
Shake the ice bucket instead.
During periods of limited use or high ambient temperatures, it is common for
cubes to fuse together. Gently shake the bucket to break apart cubes. If not
using the ice maker regularly, empty the ice bucket periodically to ensure
fresh cubes.
It is normal for cubes to appear cloudy. The cause is air trapped in the water
because of fast freezing. It is not caused by the health, taste or chemical
make up of the water. It is the same air that is in every glass of water you
drink.
Remove the ice bucket for emptying and cleaning. To remove the ice bucket,
raise the bin arm and remove the bucket from the ice compartment. Use the ice
bucket for ice storage only.
ICE MAKER ADJUSTMENT
Ice Cube Thickness Adjustment
Interval – As Required
On ice maker equipped models, adjust the cube size by changing water amount injected into the ice maker assembly as follows:
-
Remove the ice maker assembly cover (1).
-
Find the adjusting screw on the ice maker assembly control box (2). The adjusting screw is just below the minus (-) and plus (+) signs on the control box.
CAUTION
Too large of an adjustment to the screw can cause the water to overflow the ice maker and can cause property damage. -
Turn the adjusting screw toward the minus (-) sign (clockwise) for smaller cubes or toward the plus (+) sign (counterclockwise) for larger cubes.
-
Install the ice maker assembly cover.
ADJUSTING ICE HARVEST
- Remove the front grille (see GRILLE INSTALLATION).
- Using a flat tip screwdriver, turn the adjusting screw (3) a small increment clockwise for a COLDER setting (slower ice production) or counterclockwise for a WARMER setting (faster ice production).
Reinstall the front grille (two screws).
Airflow and Product Loading
AIRFLOW
External
- Do not block the front grille – no additional clearance around sides, top or rear of unit is needed for ventilation
- Do not install behind a closed door
Internal
When loading, leave space between internal fans, vents, and side walls to allow air to circulate freely
PRODUCT LOADING
Bottles and cans come in many shapes and sizes. Not all bottles and cans will
fit on every shelf and wine rack. Larger diameter champagne and Magnum bottles
only fit on wine racks when noted on the product specifications. When
determining capacities U-Line uses typical 12 oz. cans, 12 oz. bottles, 750 mL
white wine and red wine bottles shown below.
NOTICE
Restricting airflow may result in poor product performance, product failure,
and uneven internal temperatures and may freeze contents.
Cleaning
Stainless Models
- Stainless door panels and handles can discolor when exposed to chlorine gas, pool chemicals, saltwater or cleaners with bleach.
- Keep your stainless unit looking new by cleaning with a good quality all-in-one stainless steel cleaner and polish monthly. For best results use Claire® Stainless Steel Polish and Cleaner. Comparable products are acceptable.
- Frequent cleaning will remove surface contamination that could lead to rust. Some installations may require cleaning weekly.
- Do not clean with steel wool pads.
- Do not use stainless steel cleaners or polishes on any glass surfaces.
- Clean any glass surfaces with a non-chlorine glass cleaner.
- Do not use cleaners not specifically intended for stainless steel on stainless steel surfaces (this includes glass, tile and counter cleaners).
- If any surface discoloring or rusting appears, clean it quickly with Bon-Ami® or Barkeepers Friend Cleanser® and a nonabrasive cloth. Always clean with the grain. Always finish with Claire® Stainless Steel Polish and Cleaner or
- comparable product to prevent further problems.
- Using abrasive pads such as Scotchbrite™ will cause the graining in the stainless steel to become blurred.
- Rust not cleaned up promptly can penetrate the surface of the stainless steel and complete removal of the rust may not be possible.
- Integrated Models
- To clean integrated panels, use household cleaner per the cabinet manufacturer’s recommendation.
INTERIOR CLEANING
- Disconnect power to the unit.
- Clean the interior and all removed components using a mild nonabrasive detergent and warm water solution applied with a soft sponge or non-abrasive cloth.
- Rinse the interior using a soft sponge and clean water.
- Do not use any solvent-based or abrasive cleaners. These types of cleaners may transfer taste to the interior products and damage or discolor the lining.
DEFROSTING
- Under normal conditions this unit does not require manual defrosting. Minor frost on the rear wall or visible through the evaporator plate vents is normal and will melt during each off cycle.
- If there is excessive build-up of 1/4″ (6 mm) or more, manually defrost the unit.
- Ensure the door is closing and sealing properly.
- High ambient temperature and excessive humidity can also produce frost.
CAUTION
DO NOT use an ice pick or other sharp instrument to help speed up
defrosting. These instruments can puncture the inner lining or damage the
cooling unit. DO NOT use any type of heater to defrost. Using a heater to
speed up defrosting can cause personal injury and damage to the inner lining.
NOTICE
The drain pan was not designed to capture the water created when manually
defrosting. To prevent water from overflowing the drain pan and possibly
damaging water-sensitive flooring, the unit must be removed from the
cabinetry.
To defrost:
- Disconnect power to the unit.
- Remove all products from the interior.
- Prop the door in an open position (2 in. [50 mm] minimum).
- Allow the frost to melt naturally.
- After the frost melts completely clean the interior and all removed components. (See INTERIOR CLEANING).
- When the interior is dry, reconnect power and turn unit on.
Cleaning Condenser
INTERVAL – EVERY SIX MONTHS
To maintain operational efficiency, keep the front grille free of dust and
lint, and clean the condenser when necessary. Depending on environmental
conditions, more or less frequent cleaning may be necessary.
WARNING
- Disconnect electric power to the unit before cleaning the condenser.
- DO NOT touch the condenser fins. The condenser fins are SHARP and can be easily damaged.
NOTICE
DO NOT use any type of cleaner on the condenser unit.
- Remove the grille. (See GRILLE-PLINTH INSTALLATION).
- Clean the condenser coil using a using a soft brush with a “combing” action or vacuum cleaner. Do not touch the condenser coil.
- Install the grille.
Extended Non-Use
VACATION/HOLIDAY, PROLONGED SHUTDOWN
The following steps are recommended for periods of extended non-use:
- Remove all consumable content from the unit.
- . Disconnect the power cord from its outlet/socket and leave it disconnected until the unit is returned to service.
- Turn off the water supply.
- If ice is on the evaporator, allow ice to thaw naturally.
- Clean and dry the interior of the cabinet. Ensure all water has been removed from the unit.
- Disconnect the water and drain line (if applicable) making sure all water is removed from the lines.
- The door must remain open to prevent formation of mold and mildew. Open door a minimum of 2” (50 mm) to provide the necessary ventilation.
WINTERIZATION
If the unit will be exposed to temperatures of 40°F (5°C) or less, the steps
above must be followed. In addition, P60 drain pumps in clear ice machines
must be drained according to the following procedure:
- Remove the drain pump from the ice machine.
- Drain the water in the pump’s reservoir by turning the pump upside down and allowing the water to drain through the pump’s inlet and vent tube fittings.
- After water is drained, reinstall the drain pump and reattach all connections.
For questions regarding winterization, please call U- Line at
414.354.0300.
CAUTION
Damage caused by freezing temperatures is not covered by the warranty.
Do not put anti-freeze in your unit.
Wire Diagram
U-Line Corporation (U-Line) Limited Warranty
One Year Limited Warranty
For one year from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by U-Line under the above warranty must be performed by a
U-Line factory authorized servicer, unless otherwise specified by U-Line.
Service provided during normal business hours.
Two Year Limited Warranty (5 Class Product)
For two years from the date of original purchase, this warranty covers all
parts and labor to repair or replace any part of the product that proves to be
defective in materials or workmanship. For products installed and used for
normal residential use, material cosmetic defects are included in this
warranty, with coverage limited to 60 days from the date of original purchase.
All service provided by U-Line under the above warranty must be performed by a
U-Line factory authorized servicer, unless otherwise specified by U-Line.
Service provided during normal business hours.
Available Second & Third Year Limited Warranty
In addition to the standard one and two year warranties outlined above, U-Line
offers a one year extension of the warranties from the date of purchase, free
of charge. To take advantage of this extension, you must register your product
with U-Line within 60 days from the date of purchase at u-line.com and provide
proof of purchase.
Five Year Sealed System Limited Warranty
For five years from the date of original purchase, U-Line will repair or
replace the following parts, labor not included, that prove to be defective in
materials or workmanship: compressor, condenser, evaporator, drier, and all
connecting tubing. All service provided by U-Line under the above warranty
must be performed by a U-Line factory authorized servicer, unless otherwise
specified by U-Line. Service provided during normal business hours.
Terms
These warranties apply only to products installed in any one of the fifty
states of the United States, the District of Columbia, or the ten provinces of
Canada. The warranties do not cover any parts or labor to correct any defect
caused by negligence, accident or improper use, maintenance, installation,
service, repair, acts of God, fire, flood or other natural disasters. The
product must be installed, operated, and maintained in accordance with your
product’s User Guide.
The remedies described above for each warranty are the only ones that U-Line
will provide, either under these warranties or under any warranty arising by
operation of law. U-Line will not be responsible for any consequential or
incidental damages arising from the breach of these warranties or any other
warranty, whether express, implied, or statutory. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. These warranties give you
specific legal rights, and you may also have other rights which vary from
state to state.
Any warranty that may be implied in connection with your purchase or use of
the product, including any warranty of merchantability or any warranty fit for
a particular purpose is limited to the duration of these warranties and only
extends to five years in duration for the parts described in the section
related to the five-year limited warranty above. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitations
may not apply to you.
- The warranties only apply to the original purchaser and are non-transferable.
- The second, third, and five-year warranties cover products installed and used for normal residential or designated marine use only.
- The warranties apply to units operated outside only if designed for outdoor use by model and serial number.
- U-Line Commercial products are covered by the one-year and 5-year limited warranties and are not eligible for the second and third-year limited warranties.
- Replacement water filters, light bulbs, and other consumable parts are not covered by these warranties.
- The start of U-Line’s obligation is limited to four years after the shipment date from U-Line.
- In-home instruction on how to use your product is not covered by these warranties.
- Food, beverage, and medicine loss are not covered by these warranties.
- If the product is located in an area where U-Line factory authorized service is not available, you may be responsible for a trip charge or you may be required to bring the product to a U-Line factory authorized service location at your own cost and expense.
- Units purchased after use as floor displays, and/or certified reconditioned units, are covered by the limited one year warranty only and no coverage is provided for cosmetic defects.
- Signal issues related to Wi-Fi connectivity are not covered by these warranties.
For parts and service assistance, or to find U-Line factory authorized service near you, contact U-Line: 8900 N. 55th Street, Milwaukee, WI 53223 • u-line.com • onlineservice@u-line.com • +1.414.354.0300
Copyright © 2020 U-Line Corporation. All Rights Reserved. | Publication Number 30379 | 11/2020 Rev. O
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>