APC MONDO PLUS Wi-Fi Access Control Keypad With Card Reader User Manual
- June 16, 2024
- APC
Table of Contents
- APC MONDO PLUS Wi-Fi Access Control Keypad With Card Reader
- Product Information
- Product Usage Instructions
- FAQ
- Description
- Features
- Specifications
- Wiring Output
- Indicators
- Installation
- Programming
- APP Configuration
- Edit Temporary Code
- Setting
- APC WARRANTY
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
APC MONDO PLUS Wi-Fi Access Control Keypad With Card Reader
Product Information
Specifications
- Working Voltage: DC12-18V
- Card Reading Distance: 13cm
- Working Temperature: -40 to 60 degrees Celsius
- Lock Output Load: 2A Maximum
- Standby Current: 60mA
- Capacity: 1000 users
- Working Humidity: 10% – 90%
- Door Relay Time: 0-99 seconds (adjustable)
Description
The MONDO+PLUS is a Wi-Fi Access Control Keypad with a card reader. It features ultra-low power consumption and a Wiegand interface. The keypad has a backlight for easy operation at night and allows users to generate temporary codes through an app. It supports access methods such as card, pin code, and card & pin code. Users can change codes by themselves and delete lost cards using the keypad.
Features
- Ultra-low power consumption
- Wiegand interface
- Backlight keypad
- Temporary code generation through app
- Multiple access methods (card, pin code, card & pin code)
- Independent code assignment
- Code change and deletion by users
Product Usage Instructions
Quick Wiring and Programming for Automatic Gates
Refer to Page 4 of the user manual for quick wiring and programming instructions for automatic gates.
Quick Wiring and Programming for Electric Strikers
Refer to Page 5 of the user manual for quick wiring and programming instructions for electric strikers.
Adding Standard Users
A standard user can be added with or without an ID number. It is recommended to use the ID number method as it simplifies deleting a user in the future. If you do not assign an ID number, you may need to delete all users when removing a user.
Adding Standard Users with an ID number
To add a standard user with an ID number:
- Enter the master code followed by “#”. (Default factory master code is 123456)
- Enter the ID number (4 digits) followed by “#”.
- Enter the pin code followed by “#”.
Adding Standard Users without an ID number
To add a standard user without an ID number:
- Enter the master code followed by “#”. (Default factory master code is 123456)
- Enter the card followed by “Add card”.
- Enter the pin code followed by “Add Pin”.
Deleting Users
To delete users:
- Enter the master code followed by “#”. (Default factory master code is 123456)
- For deleting cards, enter “Delete card”.
- For deleting pin codes, enter “Delete Pin code”.
- For deleting ID numbers, enter “Delete ID number”.
- For deleting all users, enter “Delete ALL users”.
Setting the Usage Method
The system can be set to be used by card OR PIN code (Default), CARD ONLY, or Card and Pin together (Dual Authentication).
- To set the system to be used by card only, enter the master code followed by “#”, “4”, and “1”.
- To set the system to be used by card and PIN code, enter the master code followed by “#”, “4”, and “2”.
- To set the system to be used by card or PIN code, enter the master code followed by “#”, “4”, and “4”.
FAQ
Q: What is the default factory master code?
A: The default factory master code is 123456.
Q: What is the card reading distance?
A: The card reading distance is 13cm.
Wi-Fi Access Control Keypad with card reader
Quick Wiring and Programming for Automatic Gates on Page 4 Quick Wiring and Programming for Electric Strikers on Page 5
Description
The APC Automation Systems ® MondoPlus is a standalone access control keypad with a Swipe card reader as well as control by APP from anywhere in the world. Both Fail Secure and Fail Safe locks can be used and also allow the integration of exit buttons and allow the user to generate a temporary code remotely through the APP.
Features
Ultra-low Power Consumption | Standby current is less than 60mA at 12~18V DC |
---|---|
Wiegand Interface | Wg26 ~34 bits input and output |
Searching time | Less than 0.1s after reading card |
Backlight keypad | Operate easily at night |
Temporary code | User can generate a Temporary code through APP |
Access Methods | Card, Pin code, Card & Pin code |
Independent codes | Use codes without related card |
Change codes | Users can change codes by themselves |
Delete users by card No. | The lost card can be delete by keypad |
Specifications
Working Voltage:DC12-18V | Standby Current: ≤60mA |
---|---|
Card Reading Distance:1~3cm | Capacity:1000 users |
Working Temperature:-40℃~60℃ | Working Humidity:10%~90% |
Lock output load:2A Maximum | Door Relay time 0~99S (Adjustable) |
Wiring Output
Color | ID | Description |
---|---|---|
Green | D0 | Wiegand Input(Wiegand Output in Card Reader Mode) |
White | D1 | Wiegand Input(Wiegand Output in Card Reader Mode) |
Yellow | OPEN | Exit Button input terminal |
Red | +12V | 12-18V + DC Regulated Power Input |
Black | GND | 12-1-8V DC Regulated Power Input |
Blue | NO | Relay Normally-Open |
Brown | COM | Relay Common |
Grey | NC | Relay Normally Closed |
Indicators
Operate Status | LED Light Color | Buzzer |
---|---|---|
Standby | Red | |
Keypad Touch | Beep | |
Operation Successful | Green | Beep- |
Operation Failed | Beep-Beep-Beep | |
Entering into Programming | Flash Red Slowly | Beep- |
Programmable Status | Orange | Beep |
Exit Programming | Red | Beep- |
Door Opening | Green | Beep- |
Installation
- Fix the mounting plate as per the two holes (A and C) on the plate to the surface in which the keypad will be installed.
- Feed the keypad cable through the hole B insuring that any unused wires are isolated from one another.
- Fit the keypad to the mounting plate and fix in place using the phillips screw underneath.
Programming
Adding Standard Users
A standard user can be added with and without a ID number, it is recommended to use the ID number method as it will simplify deleting a user in the future. If you do not use the assign the ID number you may need to delete all users when needing to remove a user.
APP Configuration
APP Install and Registration (All Users)
- Download Tuya Smart from the APP Store on your Android/Apple Device.
- Open the App and register an account ensuring you select “Australia” as the country
- Login after registration. NOTE: Each user must register there own account.
APP Preparation (Home Owners Device)
Adding the Keypad to the Administrator (Home Owners) Device
Sharing with another User(Administrator/ordinary member)
Note: Then member that you shared to must be register to Tuya App First.
Manage Members
Note: The Owner (Super Master) can decide effective time (Permanent or Limited) to the members.
Manage Members
Note: The Owner (Super Master) can decide effective time (Permanent or Limited) to the members.
ADD Users PINCODE via APP support.
Note: Can add a Pin code by desired number or generate a random number. can copy the Number and forward to the user.
ADD Users Card via APP support.
Note: Can add a swipe Card via App support with following procedure. Swipe card must be presented near the keypad during this process.
Delete users pin code/ Card
Note: Using same process we can delete CODE or Card from the user.
Temporary Code
- Temporary Code can be created or Randomly generated using APP and can be shared with the guest/Users by ( whatsapp, skype, emails and wechat )
- Two types of Temporary code can be created CYCLICITY and ONCE.
- CYCLICITY: Code can be created for a particular period, particular day and Particular Time.
- For example, Valid at 9:00 am ~ 5:00 pm every Monday~Friday during May~August.
- ONCE: One-time Code can be created, valid for 6 hours and can only be used Once.
CYCLICITY:
ONCE:
Note: One-time Code can be created, valid for 6 hours and can only be used Once.
Edit Temporary Code
Temporary code can be deleted, edited or renamed in the valid period.
Timer/ Door keep Open
Setting
-
Remote unlock setting
Default is on. Once turn off, all the mobile users will not be able to access the lock by APP Permission se ng
Default is Permission all. Can be set Permission admin only. -
Passage set
Default is Public. All mobile users have the passage permission. Once turn off, we can give the passage permission to specific mobile users. -
Automa c Lock
Default is on. Automa c Lock on: Pulse Mode Automa c Lock off: Latch Mode -
Auto lock me
Default is 5 seconds. It can be set from 0~100 seconds. -
Alarm me
Default is 1 minute. It can be set from 1 ~3 minutes. -
Doorbell volume
It can set device buzzer volume Mute, Low , Middle and High
Log(including open History and Alarms)
Log open history and Alarms can be viewed by clicking on the Notification icon as shown in the picture
Remove Device & Reset Wifi Blinding
Note:
Disconnect is just removing the device from the APP. The users (card/
fingeprirnt /code) are s ll retained. (If Super Master Disconneted, all other
memebers will have no access to the device)
Disconnect and wipe data is unbinding the device and reset WiFi.
(Means this device can be connected by other new users)
Method 2 to reset the WiFi
* {Master Code)# 9 {Master Code)#
(To change the Master Code, please refer to another user manual)
APC WARRANTY
APC warrants the original purchasers or the APC system for a period of twelve
months from the date of purchase (not installation), the product shall be free
of defects in materials and workmanship under normal use.
During the warranty period, APC shall, as its option, repair or replace any
defective product upon return of the product to its factory, at no charge for
labour and materials.
Any replacement and/or repaired parts are warranted for the remainder of the
original warranty,
The original owner must promptly notify APC in writing that there is defect in
material or workmanship, such written notice must be received in all events
prior to expiration of the warranty.
International Warranty
APC shall not be responsible for any freight fees, taxes or customs fees.
Warranty Procedure
To obtain service under this warranty, AND AFTER CONTACTING APC, please return
the item(s) in question to the point of purchase.
All authorized distributors and dealers have a warranty program, anyone
returning goods to APC must first obtain an authorization number. APC will not
accept any shipment for which prior authorization has not been used.
Conditions to Void Warranty
This warranty applies only to defects in pairs and workmanship relating to
normal use. It does not cover:
- Damage incurred in shipping or handling
- Damage caused by disaster such as fire, flood, wind, earthquake or lightning
- Damage due to causes beyond the control of APC such as excessive voltage, mechanical shock or water damage
- Damage caused by unauthorized attachment, alterations, modifications, or foreign objects.
- Damage caused by peripherals (unless such peripherals were supplied by APC)
- Defects caused by failure to provide a suitable installation environment for the products
- Damage caused by usage of the products for purpose other than those for which it was designed.
- Damage from improper maintenance
- Damage arising out of any other abuse, mishandling, and improper application of the products.
Under no circumstances shall APC be liable for any special, incidental, or consequential damages based upon breach of warranty, breach of contract, negligence, strict liability, or any other legal theory. Such damages include, loss of profits, loss of the product or any associated equipment, cost of capital, cost of substitute or replacement equipment, facilities or services, down time, purchaser’s time, the claims of third parties, including customers, and injury to property.
Disclaimer of Warranties
This warranty contains the entire warranty and shall be in lieu of any and all
other warranties, whether expressed or implied (including all implied
warranties of merchantability or fitness for a particular purpose). And of all
other obligations or purporting to act on its behalf to modify or to change
this warranty, nor to assume for it any other warranty or liability concerning
this product.
Out of Warranty Repairs
APC will at its option repair or replace out-of-warranty products which are
returned to its factory according to the following conditions. Anyone
returning goods to APC must first obtain an authorization number.
APC will not accept any shipment whatsoever for which prior authorization has
not been obtained. Products which APC determines to be repairable will be
repaired and returned. A set fee which APC has been predetermined and which
may be revised from time to time will be charged for each unit repaired.
Products which APC determines not repairable will be replaced by the nearest
equivalent product available at that time. The current market price for the
replacement product will be charged for each replacement unit.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>