Introduction

Scope of the Manual
This manual provides instructions and parts lists for 67C Series Instrument Supply Regulators. Instructions and parts lists for other equipment mentioned in this instruction manual, as well as for other 67C Series Regulators, are found in separate manuals.

Product Descriptions
The 67C Series Direct-Operated Regulators are typically used to provide constantly controlled, reduced pressures to pneumatic and electro-pneumatic controllers and other instruments. They are suitable for most air or gas applications. Other applications include providing reduced pressures to air chucks, air jets and spray guns.

  • The Types 67C and 67CS are the standard instrument supply regulators without a filter or internal relief.
  • The Types 67CF and 67CFS are equipped with a filter for removing particles from the supply gas.
  • The Types 67CR and 67CSR have an internal relief valve with a soft seat for reliable shutoff with no discernible leakage.
  • The Types 67CFR and 67CFSR have a filter and internal relief valve with a soft seat for reliable shutoff with no discernible leakage.

Principle of Operation
Downstream pressure is registered internally on the lower side of the diaphragm. When the downstream pressure is at or above the set pressure, the valve plug is held against the orifice and there is no flow through the regulator. When demand increases, downstream pressure drops slightly allowing the spring to extend, moving the stem down and the valve plug away from the orifice. This allows flow through the regulator.

Specifications

The Specifications section gives some general specifications for the 67C Series Regulator. A label on the spring case gives the control spring range for a given regulator as it comes from the factory.

  • Body Size, Inlet and Outlet Connection Style 1/4 NPT
  • Maximum Inlet Pressure (Body Rating)(1)
  • All except Types 67CS and 67CSR: 250 psig / 17.2 bar
  • Types 67CS and 67CSR: 400 psig / 27.6 bar
  • Outlet Pressure Ranges See Table 1
  • Maximum Emergency Outlet Pressure(1)
  • 50 psi / 3.4 bar over outlet pressure setting
  • Wide-Open Flow Coefficients
  • Main Valve: Cg: 11.7; Cv: 0.36; C1: 32.2
  • Internal Relief Valve: Cg: 1.45; Cv: 0.045; C1: 32.8
  • IEC Sizing Coefficients
  • Main Valve: XT: 0.66; FL: 0.89; FD: 0.50

Accuracy

  • Inlet Sensitivity for Nitrile (NBR) and
  • Silicone (VMQ) Elastomers: Less than
  • 0.2 psig / 14 mbar change in outlet pressure for every
  • 25 psig / 1.7 bar change in inlet pressure
  • Inlet Sensitivity for Fluorocarbon (FKM) Elastomers:
  • Less than 0.4 psig / 28 mbar change in outlet pressure
  • for every 25 psig / 1.7 bar change in inlet pressure
  • Repeatability for Nitrile (NBR) and Silicone (VMQ)
  • Elastomers: 0.1 psig / 7 mbar(2)
  • Repeatability for Fluorocarbon (FKM) Elastomers:
  • 0.3 psig / 21 mbar(2)
  • Air Consumption: Testing repeatedly shows
  • no discernible leakage
  • Types 67CR, 67CSR, 67CFR and 67CFSR

Internal Relief Performance

  • Low capacity for minor seat leakage only; other
  • overpressure protection must be provided if inlet
  • pressure can exceed the maximum pressure rating of downstream equipment or exceeds maximum outlet pressure rating of the regulator.

Approximate Weights

  • Types 67C, 67CR, 67CF and 67CFR: 1 lb / 0.5 kg
  • Types 67CS and 67CSR: 2.5 lbs / 1.1 kg
  • Types 67CFS and 67CFSR: 4 lbs / 1.8 kg
  • Temperature Capabilities(1)
  • With Nitrile (NBR)
  • Standard bolting: -20 to 180°F / -29 to 82°C
  • Stainless steel bolting: -40 to 180°F / -40 to 82°C
  • With Fluorocarbon (FKM)(6): 0 to 180°F / -18 to 82°C
  • Stainless steel or Glass Filter (optional): 0 to 300°F / -18 to 149°C

Temperature Capabilities(1)(continued)

  • With Silicone (VMQ)(3)
  • Diaphragm and Low Temperature bolting:
  • -60 to 180°F / -51 to 82°C
  • With Gauges: -40 to 180°F / -40 to 82°C
  • Arctic/Extreme Low Temperature Construction(3)(8)
  • Low Temperature Silicone (VMQ)/
  • Fluorosilicone (FVMQ)/Nitrile (NBR) and
  • Low Temperature bolting: -76 to 140°F / -60 to 60°C
  • Smart Bleed™ Check Valve Setpoint
  • 6 psi / 0.41 bar differential
  • Types 67CF, 67CFR, 67CFS and 67CFSR
  • Filter Capabilities
  • Free Area: 12 times pipe area
  • Micron Rating: Polyethylene Filter(5) (standard): 5 microns
  • Glass Fiber Filter (optional): 5 microns
  • Stainless steel Filter (optional): 40 microns
  • Drain Valve and Spring Case Vent Location
  • Aligned with inlet standard, other positions optional

Pressure Registration

  • Handwheel adjusting screw
  • Inlet screen
  • NACE MR0175 or NACE MR0103 construction(4)
  • Panel mount (includes spring case with 1/4 NPT vent, handwheel and panel mounting nut)
  • Closing cap (available on spring case with 1/4 NPT vent)
  • Fluorocarbon (FKM) elastomers for high temperatures and/or corrosive chemicals
  • Silicone (VMQ) elastomers for cold temperatures
  • Fixed Bleed Restriction
  • Triple scale outlet pressure gauge (Brass or Stainless steel)
  • Stainless steel stem on the valve plug
  • Tire valve or pipe plug in second outlet
  • Types 67CFR and 67CFSR only
  • Smart Bleed internal check valve(7)
  • Large dripwell with manual or automatic drain
  • Types 67CF and 67CFR only
  • Stainless steel drain valve
  1. The pressure/temperature limits in this Instruction Manual and any applicable standard or code limitation should not be exceeded.
  2. Repeatability is the measure of the regulator’s ability to return to setpoint consistently when traveling from steady state to transient to steady state.
  3. Silicone (VMQ) is not compatible with hydrocarbon gas.
  4. Product complies with the material requirements of NACE MR0175. Environmental limits may apply.
  5. Do not use in high aromatic hydrocarbon service.
  6. Consult factory for applications where the Smart Bleed unit will be at process temperatures above 180°F / 82°C for an extended period.
  7. The Smart Bleed internal check valve is bubble tight at temperatures down to -40°F / -40°C. Leakage from P1 to P2 is possible at temperatures below -40°F / -40°C.
  8. The arctic/extreme low temperature construction passed Emerson laboratory testing for lockup and external leakage down to -76°F / -60°C. Some internal relief valve venting may occur at
    temperatures below -58°F / -50°C.Emerson-Fisher-67CFR-Air-Filter-Regulator-
FIG- \(1\)

Internal Relief (Types 67CR, 67CSR, 67CFR and 67CFSR)
If for some reason, outside of normal operating conditions, the downstream pressure exceeds the setpoint of the regulator, the force created by the downstream pressure will lift the diaphragm until the diaphragm is lifted off the relief seat. This allows flow through the token relief. The relief valve on the Type 67CR, 67CSR, 67CFR or 67CFSR is an elastomer plug that prevents leakage of air from the downstream to atmosphere during normal operation, thereby conserving plant air.

Smart Bleed™ Airset

Recommended for fail-safe actuators, no bleed applications and dead-end service. In some cases, it is desired to exhaust downstream pressure if inlet pressure is lost or drops below the setpoint of the regulator. For example, if the regulator is installed on equipment that at times has no flow demand but is expected to backflow on loss of inlet pressure. The Types 67CFR and 67CFSR can be ordered with the Smart Bleed option which includes an integrated soft seat check valve. During operation, if inlet pressure is lost or decreases below the setpoint of the regulator, the downstream pressure will back flow upstream through the regulator and check valve.

This option eliminates the need for a fixed bleed downstream of the regulator, thereby conserving plant air. In addition, the soft seat feature of the check valve eliminates leakage while the airset is in the lock-up position, preventing pressure build-up that could trip safety loop functions on valves. Overpressure Protection The 67C Series Regulators have maximum outlet pressure ratings that are lower than their maximum inlet pressure ratings. A pressure relieving or pressure limiting device is needed if inlet pressure can exceed the maximum outlet pressure rating.

Types 67CR, 67CSR, 67CFR and 67CFSR have a low capacity internal relief valve for minor seat leakage only. Other overpressure protection must be provided if the maximum inlet pressure can exceed the maximum pressure rating of the downstream equipment or exceeds the maximum outlet pressure rating of the regulator.’

Table 1. Outlet Pressure Ranges and Control Spring Data

__

TYPE

| __

OUTLET PRESSURE RANGE

| CONTROL SPRING DATA
---|---|---
__

Color

| __

Material

| __

Part Number

| Wire Diameter| Free Length
psig| bar| In.| mm| In.| mm
| 0 to 20| 0 to 1.4| Green stripe| | GE07809T012| 0.135| 3.43| 1.43| 36.2
| 0 to 35| 0 to 2.4| Silver| Music| T14059T0012| 0.156| 3.96| 1.43| 36.2
67C, 67CR,

67CF and 67CFR

| 0 to 60

0 to 125

| 0 to 4.1

0 to 8.6

| Blue stripe Red stripe| Wire| T14058T0012 T14060T0012| 0.170

0.207

| 4.32

5.26

| 1.43

1.43

| 36.2

36.2

0 to 35| 0 to 2.4| Silver stripe| | T14113T0012| 0.156| 3.96| 1.43| 36.2
| 0 to 60| 0 to 4.1| Blue| Inconel®| T14114T0012| 0.172| 4.37| 1.43| 36.2
| 0 to 125| 0 to 8.6| Red| | T14115T0012| 0.207| 5.26| 1.43| 36.2
| 0 to 20| 0 to 1.3| Green| | 10C1729X012| 0.135| 3.43| 1.50| 38.1
67CS, 67CSR,

67CFS and 67CFSR

| 0 to 35

0 to 60

0 to 125

| 0 to 2.4

0 to 4.1

0 to 8.6

| Silver stripe

Blue Red

| __

Inconel®

| T14113T0012

T14114T0012 T14115T0012

| 0.156

0.172

0.207

| 3.96

4.37

5.26

| 1.43

1.43

1.43

| 36.2

36.2

36.2

| 0 to 150| 0 to 10.3| Black| | 10C1730X012| 0.250| 6.35| 1.77| 44.9

Installation

Note
If the regulator is shipped mounted on another unit, install that unit according to the appropriate Instruction Manual.

WARNING
Personal injury, property damage, equipment damage or leakage due to escaping gas or bursting of pressure-containing parts may result if this regulator is over pressured or is installed where service conditions could exceed the limits given in the Specifications section or where conditions exceed any ratings of the adjacent piping or piping connections. To avoid such injury or damage, provide pressure-relieving or
pressure-limiting devices (as required by the appropriate code, regulation or standard) to prevent service conditions from exceeding those limits.

The internal relief valve of the Type 67CR,67CSR, 67CFR or 67CFSR does not provide full overpressure protection. The internal  relief valve is designed for minor seat leakage only. If maximum inlet pressure to
the regulator exceeds maximum pressure ratings of the downstream equipment or exceeds maximum allowable outlet pressure of the regulator, additional overpressure protection is required.

A regulator may vent some gas to the atmosphere. In hazardous or flammable gas service, vented gas may accumulate and cause personal injury, death or property damage due to fire or explosion. Vent a regulator in hazardous gas service to a remote, safe location away from air intakes or any hazardous area. The vent line or stack opening must be protected against condensation or clogging. Before installing a Type 67C, 67CR, 67CS, 67CSR, 67CF, 67CFR, 67CFS or 67CFSR Regulator, be sure the installation complies with the following installation guidelines:

  1. Regulator operation within ratings does not preclude the possibility of damage from debris in the lines or from external sources. Regulators should be inspected for damage periodically and after any overpressure condition.
  2. Only personnel qualified through training and experience should install, operate and maintain a regulator. Make sure that there is no damage to or foreign material in the regulator. Also ensure that all tubing and piping is free of debris.
  3. Install the regulator so that flow is from the IN to the OUT connection as marked on the regulator body.
  4. For best drainage, orient the drain valve (key 2) to the lowest possible point on the dripwell (key 5). This orientation may be improved by rotating the dripwell with respect to the body (key 1).
  5. A clogged spring case vent hole may cause the regulator to function improperly.
  6. To keep this vent hole from being plugged (and to keep the spring case from collecting moisture, corrosive chemicals or other foreign material), orient the vent to the lowest possible point on the spring case or otherwise protect it.Inspect the vent hole regularly to make sure it is not plugged.
  7. Spring case vent hole orientation may be changed by rotating the spring case with respect to the body. A 1/4 NPT spring case vent may be remotely vented by installing obstruction-free tubing or piping into the vent. Protect the remote vent by installing a screened vent cap on the remote end of the vent pipe.
  8. For use in regulator shutdown, install upstream block and vent valves and downstream block and vent valves (if required) or provide some other suitable means of properly venting the regulator inlet and outlet pressures. Install a pressure gauge to monitor instruments on startup.
  9. Apply a good grade of pipe compound to the external pipe threads before making connections, making sure not to get the pipe compound inside the regulator.
  10. Install tubing fitting or piping into the 1/4 NPT inlet connection on the body (key 1) and into the 1/4 NPT body outlet connection.
  11. The second 1/4 NPT outlet can be used for a gauge or other use. If not used, it must be plugged. Installing a 67CF Series Regulator in an

Existing Installation
When installing a 67CF Series Regulator in an existing installation, it may be necessary to use spacers (key 34, Figure 13) to adapt the installation. If the mounting bolts are too long, place a spacer on the bolt (see Figure 13). To be sure the regulator is secure, the bolts should have at least two full threads of engagement. Startup and Adjustment Key numbers are referenced in Figures 3 through .With proper installation completed and downstream equipment properly adjusted, slowly open the upstream and downstream shutoff valve (when used) while using pressure gauges to monitor pressure.

WARNING
To avoid personal injury, property damage or equipment damage caused by bursting of pressure containing parts or explosion of accumulated gas, never adjust the control spring to produce an outlet pressure higher than the upper limit of the outlet pressure range for that particular spring. If the desired outlet pressure is not within the range of the control spring, install a spring of the proper range according to the diaphragm parts maintenance procedure.

If outlet pressure adjustment is necessary, monitor outlet pressure with a gauge during the adjustment procedure. The regulator is adjusted by loosening the locknut (key 18), if used, and turning the adjusting
screw or handwheel (key 19) clockwise to increase or counterclockwise to decrease the outlet pressure setting. Retighten the locknut to maintain the adjustment position.

Shutdown
First, close the nearest upstream block valve and then close the nearest downstream block valve (when used). Next, open the downstream vent valve. Since the regulator remains open in response to the decreasing downstream pressure, pressure between the closed block valves will be released through the open vent valve.

Maintenance

Regulator parts are subject to normal wear and must be inspected and replaced as necessary. The frequency of inspection and replacement of parts depends on the severity of service conditions and applicable codes and government regulations. Open the Type 67CF, 67CFR, 67CFS or 67CFSR drain valve (key 2) regularly to empty accumulated liquid from the dripwell (key 5).

Note
If sufficient clearance exists, the body (key 1) may remain mounted on other equipment or in a line or panel during maintenance unless the entire regulator will be replaced.

WARNING
To avoid personal injury, property damage or equipment damage caused by sudden release of pressure or explosion of accumulated gas, do not attempt any maintenance or disassembly without first isolating the regulator from system pressure and relieving all internal pressure from the regulator.

Trim Maintenance
Key numbers are referenced in Figures 3, 4 and 12.

  1. Remove four bottom plate screws (key 3) from the bottom plate (key 39) and separate the bottom plate and O-ring (key 4) from the body (key 1).
  2. Inspect the removed parts for damage and debris. Replace any damaged parts.
  3. To remove the valve cartridge assembly, grasp the end of cartridge (key 10) and pull it straight out of body (key 1). Replace with new cartridge assembly. The cartridge assembly may be disassembled and parts may be cleaned or replaced. If the soft seat (key 15) was removed, make sure it is properly snapped into place before installing the valve cartridge assembly.
  4. Check O-ring (key 14) for wear and replace, if necessary. Apply lubricant to the O-ring and place in the body. Align cartridge key to keyway in body and insert. Reinstall the O-ring (key 4), secure the bottom
    plate (key 39) with screws (key 3) and torque to 15 to 30 in-lbs / 1.7 to 3.4 Nm.

Diaphragm Maintenance

Key numbers are referenced in Figures 3 and 4.

  1. Back out the adjusting screw or handwheel (key 18) until compression is removed from the spring (key 17).

  2. Remove the spring case screws (key 3) to separate the spring case (key 7) from the body (key 1). Remove the upper spring seat (key 20) and spring (key 17).

  3. Remove the diaphragm assembly (key 16), inspect the diaphragm and replace the assembly, if necessary.

  4. Place the diaphragm assembly (key 16) on the body (key 1) as shown in Figure 3 or 4. Push down on the diaphragm assembly to make sure the valve plug (key 11) strokes smoothly and approximately 1/16 in. / 1.6 mm.
    Note
    In step 5, if installing a control spring of a different range, be sure to delete the spring range originally appearing on the label and indicate the new spring range.

  5. Stack the control spring (key 17) and upper spring seat (key 20) onto the diaphragm assembly (key 16).

  6. Install the spring case (key 7) on the body (key 1) with the vent oriented to prevent clogging or entrance of moisture. Install the six spring case screws (key 3) using a crisscross pattern and torque to 15 to 30 in-lbs / 1.7 to 3.4 Nm.
    Note
    On Types 67CS and 67CSR, lubricate the adjusting screw (key 18) thread to reduce galling of the Stainless steel.

  7. When all maintenance is complete, refer to the Startup and Adjustment section to put the regulator back into operation and adjust the pressure setting. Tighten the locknut (key 19) if used and install the closing cap (key 33) if used.

Filter Element and Trim Maintenance
Key numbers are referenced in Figures 5, 6 and 12.

  1. Remove four dripwell screws (key 3) from the dripwell (key 5) and separate the dripwell and O-ring (key 4) from the body (key 1). The filter retainer (key 9), thrust washer (key 37), filter element (key 6) and gasket (key 26) may come off with dripwell. If not, remove these parts.
  2. Inspect the removed parts for damage and debris.
  3. Replace any damaged parts. If a replacement is not available, the filter element may be cleaned.
  4. To remove the valve cartridge assembly, grasp the end of cartridge and pull it straight out of body (key 1). Replace with new cartridge assembly. The cartridge assembly may be disassembled and parts may be cleaned or replaced. If the soft seat (key 15) was removed, make sure it is properly snapped into place before installing the valve cartridge assembly.
  5. Check O-ring (key 14) for wear and replace, if necessary. Apply lubricant to the O-ring (key 14), then align cartridge key to keyway in body and insert. Reinstall the gasket (key 26), filter element (key 6), thrust washer (key 37) and filter retainer (key 9). Reinstall the O-ring (key 4), secure the dripwell with screws (key 3) and torque to 15 to 30 in-lbs / 1.7 to 3.4 N•m.

Diaphragm Maintenance
Key numbers are referenced in Figures 5 and 6. Back out the adjusting screw or handwheel (key 18) until compression is removed from the spring (key 17). Remove the six spring case screws (key 3) to separate
the spring case (key 7) from the body (key 1). Remove the upper spring seat (key 20) and spring (key 17). Remove the diaphragm assembly (key 16), inspect the diaphragm and replace the assembly, if necessary.
Place the diaphragm assembly (key 16) on the body (key 1) as shown in Figure 5. Push down on the diaphragm assembly to make sure the valve plug (key 11) strokes smoothly and approximately 1/16 in. / 1.6 mm.

Note
In step 5, if installing a control spring of a different range, be sure to delete the spring range originally appearing on the label and indicate the new spring range. Stack the control spring (key 17) and upper spring
seat (key 20) onto the diaphragm assembly (key 16). Install the spring case (key 7) on the body (key 1) with the vent oriented to prevent clogging or entrance of moisture. Install the six spring case screws (key 3) using a crisscross pattern and torque to 15 to 30 in-lbs / 1.7 to 3.4 N•m.

Note
On Types 67CFS and 67CFSR, lubricate the adjusting screw (key 18) thread to reduce galling of Stainless steel. When all maintenance is complete, refer to the Startup and Adjustment section to put the regulator
back into operation and adjust the pressure setting. Tighten the locknut (key 19) if used and install the closing cap (key 33) if used.

Parts Ordering
When corresponding with the local Sales Office about this regulator, include the type number and all other pertinent information printed on the label. Specify the eleven-character part number when ordering new parts from the following parts list.

Parts List

Key Description Part Number

Parts Kits

  • Types 67C, 67CR, 67CS and 67CSR
  • Includes valve cartridge assembly
  • (contains keys 10, 11, 12, 13, 14 and 15),
  • O-ring (key 4), diaphragm assembly (key 16)
  • and four screws (key 3)
  • Type 67C (without relief)
  • Brass stem with Nitrile (NBR) plug R67CX000012
  • Aluminum stem with Nitrile (NBR) plug (NACE) R67CX000N12
  • Type 67CR (with relief)
  • Brass stem with Nitrile (NBR) plug R67CRX00012
  • Aluminum stem with Nitrile (NBR) plug (NACE) R67CRX00N12
  • Type 67CS (without relief)
  • Stainless steel stem with Nitrile (NBR)
  • plug (NACE) R67CSX00012Emerson-Fisher-67CFR-Air-Filter-Regulator-FIG- \(2\)
  • Type 67CSR (with relief)
  • Stainless steel stem with Nitrile (NBR)
  • plug (NACE) R67CSRX0012
  • Types 67CF, 67CFR and 67CFSR
  • Includes valve cartridge assembly (contains keys 10, 11, 12, 13, 14 and 15), diaphragm assembly (key 16), O-ring (key 4), filter element (key 6), filter gasket (key 26), thrust washer (key 37) and four screws (key 3)
  • Type 67CF (without relief)
  • Brass stem with Nitrile (NBR) plug R67CFX00012
  • Aluminum stem with Nitrile (NBR) plug (NACE) R67CFX00N12
  • Type 67CFR (with relief)
  • Brass stem with Nitrile (NBR) plug R67CFRX0012
  • Aluminum stem with Nitrile (NBR) plug (NACE) R67CFRX0N12
  • Type 67CFSR (with relief)
  • Stainless steel stem with Nitrile (NBR)
  • plug (NACE) R67CFSRX012
  • Valve Cartridge Assembly Only*(1)
  • Type 67C, 67CR, 67CF or 67CFR
  • Brass stem with Nitrile (NBR) plug
  • with Nitrile (NBR) O-ring T14121T0012
  • with Silicone (VMQ) O-ring T14121T0032
  • Aluminum stem
  • with Fluorocarbon (FKM) plug T14121T0022
  • with Nitrile (NBR) plug T14121T0042
  • Aluminum stem (NACE)
  • with Nitrile (NBR) plug T14121T0052
  • with Fluorocarbon (FKM) plug T14121T0062
  • Stainless steel stem
  • with Nitrile (NBR) plug T14121T0072
  • Type 67CS, 67CSR, 67CFS or 67CFSR
  • 316 Stainless steel stem
  • with Nitrile (NBR) plug and O-rings (NACE) T14121T0092
  • with Fluorocarbon (FKM) plug and O-rings T14121T0102
  • with Nitrile (NBR) plug and
  • Silicone (VMQ) O-rings T14121T0112
  • Automatic Drain Conversion Kits
  • Includes auto-drain (key 2), four flange
  • screws (key 3), dripwell O-ring (key 4)
  • and dripwell (key 5).
  • Note: Temperature rating is 40 to 175°F / 4 to 79°C.
  • Types 67CF and 67CFR
  • Nitrile (NBR) R67ADNX0012
  • Fluorocarbon (FKM) R67ADFX0012
  • Types 67CFS and 67CFSR
  • Nitrile (NBR) R67ADNX0022
  • Fluorocarbon (FKM) R67ADFX0022

Body

  • Type 67C or 67CR, Aluminum T40643T0RG2
  • Type 67CS or 67CSR, CF3M/CF8M
  • Stainless steel GE00909X012
  • Type 67CF or 67CFR, Aluminum T80510T0012
  • Type 67CFS or 67CFSR, CF3M/CF8M
  • Stainless steel 40C1887X012
  • Type 67CFR with Smart Bleed™, Aluminum
  • Nitrile (NBR) ERAA17101A0
  • Fluorocarbon (FKM) ERAA17101A1
  • Type 67CFSR with Smart Bleed, Stainless steel
  • Nitrile (NBR) ERAA17102A0
  • Fluorocarbon (FKM) ERAA17102A1
  • 2 Drain Valve
  • Manual Type 67CF or 67CFR
  • Brass 1K418918992
  • 316 Stainless steel
  • H3946X0052
  • Type 67CFS or 67CFSR
  • 316 Stainless steel AH3946X0052
  • Automatic (only used with large capacity dripwell)
  • Type 67CFS or 67CFSR
  • Nitrile (NBR) GG00554X012
  • Fluorocarbon (FKM) GG00554X022
  • 3 Flange Screw
  • Type 67C, 67CR, 67CF or 67CFR
  • Standard spring case and spring case
  • with 1/4 NPT vent (10 required) T13526T0012
  • For wire seal
  • Zinc-plated steel (9 required) T13526T0012
  • Steel (with hole) (1 required) 14B3987X012
  • Type 67CS, 67CSR, 67CFS or
  • 67CFSR (10 required) T13526T0042
  • 4* O-ring
  • Type 67C, 67CR, 67CS or 67CSR
  • Nitrile (NBR) T14380T0012
  • Fluorocarbon (FKM) T14380T0022
  • Silicone (VMQ) T14380T0032
  • Type 67CF, 67CFR, 67CFS or 67CFSR
  • Nitrile (NBR) T14057T0042
  • Fluorocarbon (FKM) T14057T0022
  • Silicone (VMQ) T14057T0032
  • 5 Dripwell
  • Type 67CF or 67CFR, Aluminum
  • Standard T21040T0012
  • Large Capacity, manual drain GE34605X012
  • Large Capacity, automatic drain GE34606X012
  • Type 67CFS or 67CFSR,
  • CF3M/CF8M Stainless steel
  • Standard 20C1726X012
  • Large Capacity, manual drain GE34607X012
  • Large Capacity, automatic drain GE31792X012
  • 6* Filter Element
  • (Types 67CF, 67CFR, 67CFS and 67CFSR)
  • Polyethylene (5 microns) (standard) GE32761X012
  • Glass fiber (5 microns) 17A1457X012
  • 316 Stainless steel (40 microns) 15A5967X022
  • 7 Spring Case Assembly
  • Type 67C, 67CR, 67CF or 67CFR, Aluminum/Steel
  • Drilled hole vent (standard) T14070T0012
  • Single hole vent T14070T0022
  • Type 67CS, 67CSR, 67CFS or 67CFSR,
  • CF3M/CF8M Stainless steel 20C1727X012
  • 9 Filter Retainer
  • Type 67CF or 67CFR, Zinc-plated T14052T0012
  • Type 67CFS or 67CFSR, 316 Stainless steel T14052T0022
  • 10*(1) Valve Cartridge T80434T0012
  • 11*(1) Valve Plug
  • Type 67C, 67CR, 67CF or 67CFR
  • Brass stem, Nitrile (NBR) plug T14053T0012
  • Aluminum stem, Fluorocarbon (FKM) plug T14053T0022
  • Aluminum stem, Nitrile (NBR) plug T14053T0032
  • Type 67CS, 67CSR, 67CFS or 67CFSR
  • Stainless steel stem, Nitrile (NBR) plug T14053T0042
  • Stainless steel stem, Fluorocarbon (FKM) plug T14053T0052
  • 12*(1) Valve Spring
  • Type 67C, 67CR, 67CF or 67CFR
  • 302 Stainless steel T14105T0012
  • Inconel® (NACE) T14116T0012
  • Type 67CS, 67CSR, 67CFS or 67CFSR,
  • Inconel® (NACE) T14116T0012
  • 13*(1) Valve Retainer, Rynite® T14071T0012
  • 14*(1) O-ring
  • Nitrile (NBR) T14063T0012
  • Fluorocarbon (FKM) T14063T0022
  • Silicone (VMQ) T14063T0032
  • 15*(1) Soft Seat
  • Nitrile (NBR) T14055T0012
  • Fluorocarbon (FKM) T14055T0022
  • 16* Diaphragm Assembly
  • Type 67C or 67CF (without relief)
  • Nitrile (NBR) T14119T0022
  • Fluorocarbon (FKM) T14119T0042
  • Type 67CR or 67CFR (with relief)
  • Nitrile (NBR) T14119T0012
  • Fluorocarbon (FKM) T14119T0032
  • Silicone (VMQ) T14119T0052
  • Type 67CS or 67CFS (without relief)
  • Nitrile (NBR) T14119T0062
  • Fluorocarbon (FKM) T14119T0072
  • Type 67CSR or 67CFSR (with relief)
  • Nitrile (NBR) T14119T0082
  • Fluorocarbon (FKM) T14119T0092
  • Silicone (VMQ) T14119T0102
  • Spring
  • Type 67C, 67CR, 67CF or 67CFR,
  • Plated steel (standard)
  • 0 to 20 psig / 0 to 1.4 bar, Green stripe GE07809T012
  • 0 to 35 psig / 0 to 2.4 bar, Silver T14059T0012
  • 0 to 60 psig / 0 to 4.1 bar, Blue stripe T14058T0012
  • 0 to 125 psig / 0 to 8.6 bar, Red stripe T14060T0012
  • Type 67CR or 67CFR (NACE), Inconel® (NACE)
  • 0 to 35 psig / 0 to 2.4 bar, Silver stripe T14113T0012
  • 0 to 60 psig / 0 to 4.1 bar, Blue T14114T0012
  • 0 to 125 psig / 0 to 8.6 bar, Red T14115T0012
  • Type 67CS, 67CSR, 67CFS or
  • 67CFSR, Inconel® (NACE)
  • 0 to 20 psig / 0 to 1.3 bar, Green 10C1729X012
  • 0 to 35 psig / 0 to 2.4 bar, Silver stripe T14113T0012
  • 0 to 60 psig / 0 to 4.1 bar, Blue T14114T0012
  • 0 to 125 psig / 0 to 8.6 bar, Red T14115T0012
  • 0 to 150 psig / 0 to 10.3 bar, Black 10C1730X012

Adjusting Screw

  • Type 67C, 67CR, 67CF or 67CFR,
  • Zinc-plated steel
  • For standard spring case
  • Square head (standard) T14061T0012
  • Handwheel T14102T0012
  • Wire seal (not shown) T14104T0012
  • For spring case with 1/4 NPT vent,

Zinc-plated steel

  • Square head for closing cap, T14101T0012
  • Handwheel T14103T0012
  • Wire seal (not shown) T14198T0012
  • Adjusting Screw (continued)
  • Type 67CS, 67CSR, 67CFS or 67CFSR
  • Square head with or without closing cap,
  • 316 Stainless steel T14101T0022
  • Handwheel, Zinc-plated steel T14103T0012

Locknut

  • Type 67C, 67CR, 67CF or 67CFR
  • Zinc-plated steel 1A946324122
  • 316 Stainless steel 1A9463X0042
  • Type 67CS, 67CSR, 67CFS or 67CFSR
  • 316 Stainless steel 1A9463X0042
  • 20 Upper Spring Seat
  • Type 67C or 67CR only
  • 1/4 NPT Vent T14051T0042
  • Type 67C, 67CR, 67CF or 67CFR
  • Standard T14051T0012
  • 22 Pressure Gauge (not shown)
  • Type 67C, 67CR, 67CF or 67CFR, Brass
  • 0 to 30 psig / 0 to 2.1 bar / 0 to 0.2 MPa 11B8579X022
  • 0 to 60 psig / 0 to 4.1 bar / 0 to 0.4 MPa 11B8579X032
  • 0 to 160 psig / 0 to 11.0 bar / 0 to 1.1 MPa 11B8579X042
  • For all types, Stainless steel
  • 0 to 30 psig / 0 to 2.1 bar / 0 to 0.2 MPa 11B9639X012
  • 0 to 60 psig / 0 to 4.1 bar / 0 to 0.4 MPa 11B9639X022
  • 0 to 160 psig / 0 to 11.0 bar / 0 to 1.1 MPa 11B9639X032
  • 23 1/4 in. / 6.4 mm Pipe Plug (not shown)
  • Type 67C, 67CR, 67CF or 67CFR
  • Socket head, Steel 1C333528992

For all types

  • Hex head, Stainless steel 1A767535072
    24 Tire Valve (not shown)

  • Type 67C, 67CR, 67CF or 67CFR 1H447099022

  • 26* Filter Gasket

  • Type 67CF, 67CFR, 67CFS or 67CFSR

  • with Nitrile (NBR) O-ring T14081T0012

  • with Fluorocarbon (FKM) O-ring T14081T0022

  • 30 NACE Tag (not shown), 18-8 Stainless steel 19A6034X012

  • 31 Panel Mounting Nut, 303 Stainless steel 10B2657X012

  • 32 Wire Seal (not shown)

  • Type 67C or 67CR

  • 304 Stainless steel 1U7581000A2

  • 33 Closing Cap, Resin 23B9152X012

  • 34 Spacer (2 required) (Figure 13)

  • Type 67CF or 67CFR, Steel T14123T0012

  • Type 67CFS or 67CFSR, 18-8 Stainless steel T14123T0022

  • Thrust Washer

  • (Type 67CF, 67CFR, 67CFS or 67CFSR)

  • with Nitrile (NBR) O-rings T14196T0012

  • with Fluorocarbon (FKM) O-rings T14196T0022

  • 39 Bottom Plate, 316 Stainless steel

  • Type 67C or 67CR GE03520XRG2

  • Type 67CS or 67CSR GE03520X012

  • 45 Screen Vent, 18-8 Stainless steel

  • Type 67CS, 67CSR, 67CFS or 67CFSR 0L078343062Parts for Mounting on Fisher™ 2500 Series

  • Controller (Type 67CF or 67CFR)

  • Key Description Part Number

  • 35 Mounting adaptor plate, Steel (not shown) T21043T0012

  • 36 O-ring, Nitrile (NBR) (not shown) 1E591406992

  • 38 Gasket, Neoprene (CR) (not shown) 1C898603012

APPLAPPLYY LUBRICANTLUBRICANT ( (LL))

L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE)

LUBRICANT L2 = ANTI-SEIZE COMPOUND
Figure 4. Type 67CS or 67CSR Assembly

APPLY LUBRICANT (L)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE) LUBRICANT L2 = ANTI- SEIZE COMPOUND

APPLY LUBRICANT (L)

Emerson-Fisher-67CFR-Air-Filter-Regulator-FIG- \(5\)
L1 = MULTI-PURPOSE POLYTETRAFLUOROETHYLENE (PTFE)

Emerson-Fisher-67CFR-Air-Filter-Regulator-FIG- \(6\)Emerson-Fisher-67CFR-Air-Filter-Regulator-FIG-
\(7\)
LUBRICANT L2 = ANTI-SEIZE COMPOUND

Emerson-Fisher-67CFR-Air-Filter-Regulator-FIG- \(8\)

Americas
McKinney, Texas 75070 USA
T +1 800 558 5853
+1 972 548 3574

Europe
Bologna 40013, Italy
T +39 051 419 0611

Asia Pacific
Singapore 128461, Singapore
T +65 6777 8211
Middle East and Africa
Dubai, United Arab Emirates
T +971 4 811 8100

D102601X012 © 2003, 2023 Emerson Process Management Regulator Technologies, Inc. All rights reserved. 03/23. The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher™ is a mark owned by Fisher Controls International LLC, a business of Emerson Automation Solutions.

The contents of this publication are presented for informational purposes only, and while every effort has been made to ensure their accuracy, they are not to be construed as warranties or guarantees, express or implied, regarding the products or services described herein or their use or applicability. All sales are governed by our terms and conditions, which are available upon request. We reserve the right to modify or improve the designs or specifications of such products at any time without notice.

Emerson Process Management Regulator Technologies, Inc. does not assume responsibility for the selection, use or maintenance of any product. Responsibility for proper selection, use and maintenance of any Emerson Process Management Regulator Technologies, Inc. product remains solely with the purchaser.

Download PDF:Emerson Fisher 67CFR Air Filter Regulator Instruction Manual

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Emerson User Manuals

Related Manuals