SKS Kontakttechnik MLS WS 100/2,5 BA452 Measuring Leads Owner’s Manual
- June 15, 2024
- SKS Kontakttechnik
Table of Contents
SKS MLS WS 100/2,5 BA452 Measuring Leads
Product Information
Specifications
- Product Name: MLS WS 100/2,5
- Operating Instruction Article Number/Color: BA452 / Black, Red, Blue, Yellow, Green, Brown, Gray, White, Violet, Yellow Green
- Measuring Leads: Safety measuring lead to IEC 61010 standard
- Connectors: 4mm diameter safety connectors with onward connection capability (4mm socket)
- Contact Spring: Nickel-plated copper beryllium
- Lead Insulation: Highly flexible, double insulated stranded lead
- Grip Sleeve: Shatter-proof
- Color Indicator: Built-in for easy identification of insulation damages
- Safety System: 4mm safety system
- Rated Voltage: AC/DC 1000V
- Measurement Category: IEC 61010 CAT II
- Rated Current: 32A (consider derating curve)
- Plug Material: Brass, nickel plated
- Housing Material: PA (Polyamide)
- Inflammability Class: V-2 (according to UL 94)
Product Usage Instructions
- Step 1: Connection
-
- Identify the measurement points where you need to connect the measuring leads.
2. Ensure that the device or circuit you are measuring is powered off.
3. Insert the 4mm diameter safety connectors at either end of the measuring leads into the corresponding sockets or terminals of the device or circuit.
4. Make sure the connections are secure and tight to ensure accurate measurements.
- Step 2: Measurement
-
- Turn on the power to the device or circuit you are measuring.
2. Select the appropriate measurement range on your measuring instrument or device.
3. Place the measuring leads in a position where they are not interfering with other components or circuits.
4. Read the measurement value on your measuring instrument or device.
-
Step 3: Safety Precautions
When working with electrical systems, it is important to follow these safety precautions: -
- Always wear appropriate personal protective equipment (PPE) such as insulated gloves and safety glasses.
2. Do not touch exposed conductors or live parts while conducting measurements.
3. Ensure that the measuring leads are not damaged or frayed before use.
4. Avoid using the measuring leads in wet or damp conditions.
5. Keep the measuring leads away from heat sources or open flames to prevent damage.
Frequently Asked Questions (FAQ)
-
What is the rated voltage for the MLS WS 100/2,5 measuring leads?
The rated voltage for the MLS WS 100/2,5 measuring leads is AC/DC 1000V. -
What is the maximum rated current for the measuring leads?
The maximum rated current for the measuring leads is 32A. However, please consider the derating curve for prolonged use at high currents. -
Can the measuring leads be used in wet conditions?
It is recommended to avoid using the measuring leads in wet or damp conditions to prevent damage and ensure safety. -
What is the material of the plug connectors?
The plug connectors of the measuring leads are made of brass and nickel plated for durability and conductivity.
SPECIFICATION
-
description Safety measuring lead to IEC 61010 standard, at either end 4 mm diameter safety connector with onward connection capability (4mm socket). Nickelplated copper beryllium contact spring. Highly flexible, double insulated stranded lead, shatter-proof grip sleeve and lead. Built in color indicator for easy indentification of insulation damages.
-
operating instruction BA452
-
*article-no. / colour** 9340881xx
-
**drawing
**
- technical data
- rated voltage AC/DC 1000 V
- measurement cat. acc. to IEC 61010 CAT II
- rated current (consider derating curve) 32 A
- material plug brass, nickel plated
- housing material PA
- temperature range acc. To IEC61010(1) -15 °C to +70 °C
- inflammability class acc. to UL 94 (only valid for basic material of housing) V-2
- cable length 100 cm
- conductor size 2,5 mm²
- cable material PVC