Specifications

  • Model: ARTIC 8000
  • Compatibility: Most lead-acid batteries (GEL, AGM, WET, MF, CA)
  • Battery Voltage: 12V
  • Battery Capacity: 4 Ah to 160 Ah (up to 240 Ah for maintenance charge)
  • Main Power: Single phase 220-240Vac 50-60Hz

Product Usage Instructions

Start Up

  1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc…).
  2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz). The display shows the battery voltage.
  3. Select the mode by pressing the button. The charge starts automatically.
  4. During the charge, the device indicates the voltage and the charge progress using the symbol. When the battery is fully charged, the symbol is displayed.
  5. The charge can be interrupted at any time by unplugging the mains plug or pressing the button.
  6. After the charge, disconnect the charger from the mains, then disconnect the charger’s connections from the battery.

Charge Modes

Mode Battery Capacity Charging Time (20% to 80%)
CHARGE mode 12V COLD option (14.7 V / 8 A) 4 Ah 2 h
CHARGE mode 12V COLD option (14.7 V / 8 A) SLOW 8 Ah 3 h
CHARGE mode 12V COLD option (14.7 V / 8 A) 15 Ah 7 h
CHARGE mode 12V COLD option (14.7 V / 8 A) 20 Ah 2 h
CHARGE mode 12V COLD option (14.7 V / 8 A) FAST 50 Ah 5 h
CHARGE mode 12V COLD option (14.7 V / 8 A) FAST 100 Ah 9 h
CHARGE mode 12V COLD option (14.7 V / 8 A) 160 Ah 14 h

Troubleshooting

Cause Solution
Unplug clamps or terminals during the charge. Reconnect the charger to the

battery.
Battery voltage too high.| Check that it is a 12V battery.
Battery is faulty or has a very low voltage.| Change the battery.

FAQ

  • Q: What types of batteries can the ARTIC 8000 charger be used for?
    A: The ARTIC 8000 charger is ideal for most lead-acid batteries, including GEL, AGM, WET, MF, and CA batteries.

  • Q: What is the maximum battery capacity that the ARTIC 8000 charger can handle?
    A: The ARTIC 8000 charger is designed for charging 12V batteries from 4 Ah to 160 Ah (up to 240 Ah for maintenance charge).

  • Q: How do I start charging my battery with the ARTIC 8000 charger?
    A: Follow these steps:

    • Connect the charger to the battery using the proper accessory (clamps, lugs, etc…).
    • Plug the charger to the mains (single phase 220-240Vac 50-60Hz). The display shows the battery voltage.
    • Select the desired charge mode by pressing the button. The charge will start automatically.
    • During the charge, the device will indicate the voltage and the charge progress using the symbol. When the battery is fully charged, the symbol will be displayed.
    • You can interrupt the charge at any time by unplugging the mains plug or pressing the button.
    • After the charge is complete, disconnect the charger from the mains, then disconnect the charger’s connections from the battery.

ARTIC 8000

SAFETY INSTRUCTIONS

  • This manual contains safety and operating instructions. Read it carefully before using the device for the first time and keep it in a safe place for future reference. This machine should only be used for charging operations comprised within the limits indicated on the machine and in the instruction manual. The operator must respect the safety precautions.
  • In case of inadequate or unsafe use, the manufacturer cannot be held liable.
  • This unit can be used by children aged of at least 8 years and by people with reduced physical, sensory or mental capabilities or lack of experience or knowledge, if they are properly monitored or if instructions for using the equipment safely was given to them and if they have been made aware of the risks. Children must no play with the product. Cleaning and maintenance should not be performed by unsupervised children.
  • Do not use to charge small batteries or non rechargeable batteries.
  • Do not use the device if the charging cable appears to be damaged or assembled incorrectly in order to avoid any risk of short circuiting the battery.
  • The operating mode of the automatic charger and the restrictions applicable to its use are explained below in this manual.

Fire and explosion risks!
A charging battery can emit explosive gases.

  • During the charge, the battery must be placed in a well ventilated area.
  • Avoid flames and sparks. Do not smoke.

Connection / disconnection:

  • Ensure that the charger’s power supply is disconnected before plugging or unplugging the connections on the battery.
  • Always ensure the Red clamp is connected to the «+» battery terminal first. If it is necessary to connect the black clamp to the vehicle chassis, make sure it is a safe distance from the battery and the fuel/exhaust pipe. The charger must be connected to the mains.
  • After charging, disconnect the charger from the mains, then disconnect the clamp from the car body and then disconnect the clamp from the battery, in the indicated order.

Connection:

  • Class II device
  • The connection to the power supply must be carried out in compliance with national standards.

Maintenance

If the power cable is damaged, it must be replaced by the manufacturer, its after sales service or an equally qualified person to prevent danger.

Regulations:

  • Machine compliant with European directives.

  • The certificate of compliance is available on our website.

  • EAC Conformity marking (Eurasian Economic Community)

  • Equipment in compliance with British requirements. The Bri-tish Declaration of Conformity is available on our website (see home page).

  • Equipment in conformity with Moroccan standards. The declaration C (CMIM) of conformity is available on our website (see cover page).

Waste management:
This product should be disposed of at an appropriate recycling facility. Do not throw away in a domestic bin.

GENERAL DESCRIPTION

  • The ARTIC 8000 charger is ideal to charge most lead-acid batteries, often used for cars and many other vehicles. The ARTIC can be used safely for : GEL (gel electrolyte), AGM (Absorbent Glass Mat), WET, MF (Maintenance Free), CA (Calcium)…
  • The ARTIC 8000 charger is designed for charging 12V batteries (6 x 2V elements) from 4 Ah to 160 Ah et up to 240 Ah for a maintenance charge.

START UP

  1. Connect the charger to the battery using the proper accessory (clamps, lugs, etc…).
  2. Plug the charger to the mains (single phase 220-240Vac 50-60Hz). The display shows the battery voltage.
  3. Select the mode by pressing button , the charge starts automatically.
  4. During the charge, the device indicates the voltage and the charge progress using the symbol . When the battery is  fully charged, the symbol is displayed.
  5. The charge can be interrupted at any time by unplugging the mains plug or pressing the ****button.
  6. After the charge, disconnect the charger from the mains, then disconnect the charger’s connections from the battery.

CHARGE MODES

Modes description :

  • CHARGE mode «SLOW» 12V (14.4 V / 2 A) :
    This mode limits the charging current to 2 A to safely charge small batteries. Activate this option to charge small batteries (< 15 Ah).

  • CHARGE mode «FAST» 12V (14.4 V / 8 A) :
    This mode is designed for lead-acid batteries, 12V from 15 Ah to 160 Ah and up to 240 Ah for floating charge.

  • CHARGE mode 12V COLD option (14.7 V / 8 A) :
    This mode modifies the charging voltage at 14.7V to charge the battery during cold weather (less than 5°C) or for some AGM batteries or batteries with caps.

•  Estimated charge time|

12v

---|---
SLOW| FAST
Battery capacity| 4 Ah| 8 Ah| 15 Ah| 20 Ah| 50 Ah| 100 Ah| 160 Ah
Charging time 20% >>> 80%| 2 h| 3 h| 7 h| 2 h| 5 h| 9 h| 14 h

TROUBLESHOOTING

| Troubleshooting| Causes| Solutions
---|---|---|---
1| ****|

  • Short-circuit.
  • Open circuit.
  • Polarity reversal

|

  • Make sure that there is no power consumption (normal or abnormal) in the vehicle circuit.
  • Check that the clamps are properly connected.
  • After following these steps, if the indicator still does not light up, the sulfated/damaged battery must be replaced.

2

| ****| Unplug clamps or terminals during the charge.| Reconnect the charger to the battery.


3

| ****| Battery voltage too high.| Check that it is a 12V battery.


4

| ****| Battery is faulty or has a very low voltage.| Change the battery.

WARRANTY

The warranty covers faulty workmanship for 2 years from the date of purchase (parts and labour).

The warranty does not cover:

  • Transit damage.
  • Normal wear of parts (eg. : cables, clamps, etc..).
  • Damages due to misuse (power supply error, dropping of equipment, disassembling).
  • Environment related failures (pollution, rust, dust).
  • In case of failure, return the unit to your distributor together with:
    • The proof of purchase (receipt etc …)
    • A description of the fault reported

TECHNICAL TABLE

| ARTIC 8000
---|---
Reference Art.-Nr.| | 029590 (UK : 029712)
Rated power supply voltage| | ~ 220-240 VAC 50 / 60 Hz
| |
Rated power| | 130 W
 Rated output voltage| | 12 VDC
 Rated output current| | 8 A
Rated battery capacity| | 4 – 160 Ah (max. 240 Ah)
| |
Battery consumption| | < 1.5 mA
Ripple| | < 200 mV rms
 Charging curve| | IUOU
Operating temperature| | -20°C – +50°C
 Storage temperature| | -20°C – +80°C
Protection rating| | IP65
 Protection class| | Class II
Noise level| | < 50dB
Weight| | 0.95 Kg
Dimensions (L x H x P)| | 220 x 96 x 59 mm
| | EN 60335-1
| | EN 60335-2-29
 Standards| | EN 62233
CEI EN 60529
EN 50581
| | EN 55014-1
EN 55014-2
| | CEI 61000-3-2
| | CEI 61000-3-3

CONTROL PANEL STICKER

GYS-Artic-8000-Arc-Welding,-Battery-Chargers-19

  1. Selection button
  2. Écran digital
  3. Charge clamps
  4. Charge terminals
  5. Mains plug

SPARE PARTS

GYS-Artic-8000-Arc-Welding,-Battery-Chargers-20

SAS GYS
1, rue de la Croix des Landes
CS 54159
53941 SAINT-BERTHEVIN
Cedex France