MORRIS MDP-25600INV 25 Power Speed Uv Ion Timer Sleep Instruction Manual
- June 16, 2024
- MORRIS
Table of Contents
- MDP-25600INV 25 Power Speed Uv Ion Timer Sleep
- SAFETY INSTRUCTIONS
- INSTALLATION
- PARTS
- CONTROL PANEL
- REMOTE CONTROL
- Troubleshooting:
- PRODUCT REPAIR
- Technical data
- NOTICE ABOUT RECYCLING
- DECLARATION OF CONFORMITY
- REGISTER THE APP
- CONNECTING THROUGH THE “ADD MANUALLY” TAB
- CONTROLLING YOUR DEVICE THROUGH THE APP
- CHANGING THE NAME OF YOUR DEVICE
- DEVICE SHARING SET UP
- ADDING ADDITIONAL DEHUMIDIFIERS
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
MDP-25600INV 25 Power Speed Uv Ion Timer Sleep
MDP-25600INV
Please read this manual carefully before use this product
**USER MANUAL**
Appendix
Wifi Instructions Manual
**** This product is using the Environment friendly refrigerant R290.(ODP
value is 0,GWP value is 3.3), this refrigerant is tasteless and combustrible,
moreover,it can burn and explode under a certain conditions;so please read
this user manual carefully before using and maintenance.
SAFETY INSTRUCTIONS
Important
The room area of this product should be more than 4m? when it is used,
repaired and stored.
This product needs to be used and stored where there is no fire source
(such as electric heater at work, stove with open fire, etc.)
- This product’s refrigerant may be odorless.
- Do not use any method to speed up the defrosting process or clean the frosted part.
- Carefully read the instructions before operating the unit.
- This appliance is for indoor use only and intended for use in a domestic environment only. Any other use is not recommended by the manufacturer and may cause fire, electrical shocks or other injury to user or property.
- Rating: This unit must be only connected to AC 220-240V / 50 Hz earthed outlet.
- Installation must be in accordance with regulations of the country where the unit is used.
- If you are in anydoubt about the suitability of your electrical supply have it checked and, if necessary, modified by a qualified electrician.
- This dehumidifier has been tested and is safe to use. However, as with any electrical appliances – use it with care.
- Disconnect the power plug from the socket before dismantling, assembling or cleaning.
- Avoid touching any moving parts of the appliance.
- Never insert fingers, pencils or any other objects though the guard
- This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities. It is also not intended for use by those with a lack of experience and knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.
- Do not leave children unsupervised with this appliance.
- Donot clean the unit by spraying it or immersing it in water.
- Never connect the unit to an electrical outlet usingan extension cord. If apower outlet is not available, one should be installed by a qualified electrician.
- Neveroperate this appliance if the cord, power adapter or plug is damaged. Ensure the power cord is not stretched or exposed to sharp object/edges.
- Adamaged power supply cord should be replaced by the manufacturer or a qualified electrician in order to avoid a hazard.
- Anyservice other thanregular cleaningor filter replacement should be performed by an authorized service representative. Failure to comply could resultina voided warranty.
- Do not use the appliance for any other purposes than its intended use.
- Do not tilt the unit while in use. The unit is designed to work only in vertical position.
- This dehumidifier must always be stored and transported upright, otherwise irreparable damage may be caused to the compressor; if in doubt we suggest waiting at least 24 hours before starting the unit.
- Avoid restarting the dehumidifier unit unless 5 minutes have passed since being turned off. This prevents damage to the compressor.
- ever use the mains plug as a switch to start and turn off the dehumidifier. Use the provided ON/OFF switch located on the control panel.
- Always place the unit on adry and stable surface.
- The appliance should not be installed in laundry or wet rooms where the humidity is higher than 85% RH
- Donotdry laundry above the unit to prevent water entering the dehumidifier. Place the laundry at least 1 meter away from your dehumidifier.
- Do not place the unit next to heat sources (e.g. electrical fires, fireplaces, etc.)
- Avoid mishandling the dehumidifier. Dropping, throwing the unit can cause damage to its internals and increases the risks of operatingt.
- Donotstoreor use gasoline, petrol, paint, solvents or other flammable vapours or liquids in the vicinity of this dehumidifier or any other appliance.
- This dehumidifier must not be used in spaces where there is a high concentration of gases, solvent or other volatile organic compounds; in very dusty environments; in any domestic, commercial or industrial environment where air composition is flammable.
Energy Saving and Unit Safety Protection Tips
- Do not cover or restrict the airflow from the outlet or inlet grills. Do not operate and follow troubleshoot procedure if the self-opening louvers do not open on power on.
- For maximum performance the minimum distance from a wall or objects should be 20 cm.
- Keep the filtersor grills of the unit clean. Under normal conditions, filters or grills should only need cleaning once every three weeks (approximately).
- Since the filters remove airborne particles, more frequent cleaning may be necessary, depending on the air quality. Vacuum both mesh and carbon filters and wash the mesh filters with hot soapy water and dry them before placing them back in the unit.
Quick visual safety guide on where or when not to use your dehumidifier.
INSTALLATION
Remove any water from the water tank before starting the unit. In order to
save energy, do not open windows or doors while the unitis running. Place the
unitona hard/flat surface. On first use run the unit continuously for 24 hrs.
To reduce noise levels:
Place a piece of carpet or arubber mat under the unit to reduce any vibrations
while the unitis running.
MDP-25600INV dehumidifiers use compressor technology to extract water from the
environment. The compressor dehumidifiers are ideal for normal domestic or
office environment which are heated during the winter months with temperatures
above 12-15°C.
These dehumidifiers are easy to move around on castors and intelligent
dehumidifiers which will extract unwanted humidity while saving money due to
their humidistat and power saving logic. MDP-25600INV dehumidifiers feature an
intelligent humidistat which is adjustable in increments of 5% from 40-80% rh
insuring your room is not dried too much and power is not wasted.
Features :
Your dehumidifier belongs to the the low energy premium dehumidifiers
featuring low power consumption, power saving logic and advanced air
purification option.
- Easy to use controls.
- Low energy only uses a fraction of the electricity of similar dehumidifiers.
- Cost effective way to combat mould, condensation and damp.
- Dries laundry more efficiently than a tumble dryer.
- Designed to complement any modern space.
- Castors for improved mobility.
- Intelligent CPU controlled digital humidistat with 35-80% RH and room humidity display.
- Quiet vs turbo fan operation ensures the right balance between quiet operation and maximum dehumidification.
- 24 hours start / stop timer.
- Tank operation or permanent drainage option with splash proof tank.
- Tank full alarm & auto-stop function.
PARTS
CONTROL PANEL
| POWER:
turn on/off the appliance.
---|---
| MODE:
Select the function of the unit between A.I./PURIFIER/DEH./LAUNDRY.
The indicator will show which mode is selected.
Al desired humidity set to 55% relative humidity and the fan is automatically
adjusted depending on current humidity level and temperature. 1)The current
temperature 25 C
The current humidity level>55%, the unit is operating dehumidification under
MID fan speed ;
The current humidity level < 55%, the unit runs at MIN speed, dehumidification
operation is not carried out. The fan runs for five minutes and then stop, and
the swing will be shut down, but the display retains. The unit shall keep this
status for 30 minutes. Then the swing and the fan open to test the current
humidity to decide the working status.
2)20C <The current temperatures25 C
The current humidity level >70%, the unit is operating dehumidification under
MAX fan speed ;
70%2The current humidity level>55%, the unit is operating dehumidification
under MID fan speed;
The current humidity level < 55%, the unit runs at MIN speed, dehumidification
operation is not carried out. The fan runs for five minutes and then stop, and
the swing will be shut down, but the display retains. The unit shall keep this
status for 30 minutes. Then the swing and the fan open to test the current
humidity to decide the working status.
3)The current temperature<20 C
The current humidity level255%, the unit is operating dehumidification under
MAX fan speed;
The current humidity level < 5%, the unit runs at MIN speed, dehumidification
operation is not carried out. The fan runs for five minutes and then stop, and
the swing will be shut down, but the display retains. The unit shall keep this
status for 30 minutes. Then the swing and the fan open to test the current
humidity to decide the working status.
PURIFIER: the machine displays the current environmental humidity. In
this mode, dehumidification operation is not carried out. The wind speed can
be adjusted to operate MAX, MID or MIN wind. The air can be purified when used
with filters. The UV and ION can also be used in this mode to further improve
the quality of air emitted.
DEH.: in DEH. mode, the humidity can be adjusted in the range of 35% –
80%, and the operation of MAX, MID or MIN wind can be adjusted at the same
time;
LAUNDRY: quick drying mode. In this mode, the default humidity of the
machine is 35%, and the humidity is not adjustable. The wind speed default is
MAX wind operation. In this mode, the machine will not stop until the water
is full or the function is turned off. Long press and hold this key for 3s to
enter the networking mode, the WiFi indicator light flashes.
| SPEED:
In the dehumidification mode and fan mode, you can adjust the operation of
MAX, MID or MIN wind.
| UV &ION
UV and ION are controlled by one button. Switch different functions by
pressing the button, and the corresponding indicator will be illuminated when
the function is turned on.
| SWING/CHILD LOCK:
Short press to perform swing function, corresponding swing indicator light is
on / off. Press and hold this button for 35 to enter the child lock mode, the
child lock indicator will be illuminated and other touch buttons are invalid;
After pressing and holding this button for another 3 seconds, the child lock
indicator is off and other touch buttons are effective.
| TIMER:
Press timer to program time. “TIMER” light comes on while timer is being
programmed. Before programming make sure that the timer function has not been
activated (the light must be off). The following timer programs are available.
Delayed power-on function (the appliance is in stand-by status) USE key “and
“-” to set the time period (1~24 hours) the appliance wil start once time
reaches the set value.
b) Delayed power-off function (whilst the appliance is running).The appliance
will stop once time reaches the set value.
| SLEEP
Press SLEEP button to enter the sleep mode, the sleep indicator is on. In
sleep mode, only sleep indicator is on, other indicator lights are turned off.
The device will work at MIN fan speed and low noise. Press SLEEP button again
to quit the sleep mode.
Hold SLEEP button for 3 seconds to turn on/off the front display.
| HUMIDITY SETTING
Press up / down key to select the desired relative humidity level, default
relative humidity is 55%. Relative humidity 35% is selected, the compressor
will not stop until the water tank is full. This button is also used to change
the duration of the timer.
| Tank full
If the water tank is full, the indicator light comes on and flashes.
| INTELLIGENT DEFROST
The appliance will defrost automatically as programmed once the coil sensor
detects that the temperature is too low, the fan speed s default to MAX speed
and the defrosting indicator wil light up in the process of defrosting. If the
previous mode is SMART/SLEEP/LAUNDRY, the appliance will recover to its
previous running mode once defrosting has finished. If the previous mode is
Deh. the fan speed will become MAX speed after the defrosting unless the user
adjust the fan speed.
| HEPA and carbon filter(air purification function)
Take out the filter from the bag and install the filter according to the “up”
indication arrows’ direction. Put the carbon side facing inwards. It is
suggested to hoover the filters every 2-3 weeks and change them every 3-6
months to always keep the room fresh and odor free. Please be sure the magnets
are on the top when install the filter in the unit. The hall switch sensor
will detect the magnets and the fan speed wil be increased automatically when
install the filter.
Humidity Level & Timer 2 digit display
The led indicator performs the following functions: 1. When the unit is
plugged in, it will indicate the room humidity level 2. When the humidity
level is selected, it will indicate the set humidity 3. When the start/ stop
timer is programmed it will show the set timer. Notes: When humidity level
is outside the normal operational parameters will show LO/HI. If ambient
humidity is lower than 20%, it will show “LO”. If ambient humidity is higher
than 90%, it willshow “HI”.
REMOTE CONTROL
Press the MODE button to change SMART/DEH./FAN/LAUNDRY mode. SMART mode –
desired humidity set to 5% relative humidity and the fan is automatically
adjusted depending on current humidity level and temperature. The desired
humidity cannot be changed in this mode. Deh. mode-In DEH. Mode, the humidity
can be adjusted in the range of 35%-80% and the operation of HIGH/MID/LOW
speed wind can be adjusted. FAN mode-Select the fan speed to adjust
HIGH/MID/LOW wind. No moisture will be extracted in this mode, which when used
with filters will purify the air. The UV and ION can also be used in this mode
to further improve the quality of air emitted.
LAUNDRY mode-Press laundry button, the function is turned on or off, the dry
mode indicator is on/off. When the function is turned on, the front panel
humidity display shows 35%, and the humidity is not adjustable; in this mode.
The compressor does not stop and continues to run until the water tank is full
or you turn off this function. UV/ION: The UV and ION functions are controlled by one
button, and the control logic is as follows:
After pressing once, the UV function is turned on, the UV icon lights up, and
the ION function and ION icon is off; After pressing twice, the UV function is
turned off, the UV icon is off, and the ION function and ION icon is on; After
pressing three times, the UV and ION functions are all turned on and the icons
are lit After pressing four times, the UV and ION functions are turned off and
the icons are all off. After pressing the button again, the function logic
will repeat again as listed above.
“i-Feel” Mode- The dehumidifier willwork from the humidity reading taken by
the remote, rather than from the dehumidifier itself. To do this, the remote
sends a humidity reading to the dehumidifier each hour, whichis then compared
against the current setting, to decide whether the dehumidifier should be
operating. to activate this mode press the up and down arrows on the remote at
the same time, the icon” ” willflash to show the mode is running.
Please note: Wheni-Feelis on, the head of the remote control should be
pointed towards the dehumidifier and should be usually on more than 3 meters
away from it. .. you have adamp spotin the house and you want to monitor the
humidity in that spot or next to achild bed instead).the i-Feel mode
willfallif the remote s not positioned correctly towards the dehumidifier.
Before activating i-Feel mode please ensure that you can operate the unit
viaremote control from where the remote is placed. low battery willalso affect
the i-Feel mode.
QUICK REFERENCE GUIDE
Power Button:
Press to turn the dehumidifier on and off.
Swing Button:
Press the Swing button, the louvre swing at 45-90 degree. Press again to lock
at the current degree. Do not operate the unit if the self-opening louvres do
not open.
Timer:
Press the timer button, then use the up/down buttons to adjust the duration of
the timer (1-24 hrs, start/ stop timer).
If set while the unit is running: The number will represent the number of
hours the unit will operate before turning off. This will not be affected if
the unit enters defrost mode or the tank is emptied and reinserted.
If set while the unit is in standby: the set number represents the period
in hours after which the unit will start. To cancel the start / stop mode
press the timer button again.
Up and Down Buttons:
During the Deh. mode when the unit is displaying the current relative
humidity, these buttons can be used to adjust the desired humidity level.
The desired relative humidity can be set between 35 and 80% in 5% increments.
Al .Mode:
This is designed for maximum convenience and maintains the ideal domestic
environment humidity level of 55% while saving electricity. It is recommended
for most users.
When the humidity setting is finished, the appliance will operate according to
the target setting humidity. When it reaches the target humidity (the selected
humidity is 2% lower than the user selected humidistat setting), the
compressor stops running, the fan continues running for five minutes and then
stops, and the swing will be shut down, but the display retains. The unit
shall keep this status for 30 minutes, then the swing and the fan open, and
the fan starts running to test the current humidity. If it has reached the
setting value, the compressor starts running. If the current humidity has not
reached the setting value, the fan will be stopped after 5 minutes, swing
shuts down. and shall again keep this status for 30 minutes, to make another
cycle as listed above.
For dryer air/ laundry mode press the key and set to a lower percent value
(e.g. 35-45%).
Note: In the Deh. mode , though, if keys set humidity at 35%, and the
machine is running clothes drying mode, and it will continue dehumidifying,
even if the ambient humidity is less than 35%, and the compressor will not
shut down. This mode applies to drying clothes and other occasions. that if
permanent drainage pipe is fitted the unit will not stop operation.
Humidity set to achieve room humidity of around 35%, good for quick drying
boost on initial runor emergencies, laundry mode. Not recommended for long
normal operation in domestic/ office environment. For allowing more moisture
in the air, press the humidity control key and set toa higher percent value
(e.g. 60-70%).
Humidity set to 50-55% RH; recommended setting, great for domestic operation
and dry storage
Humidity set to 60% RH; great for personal comfort and applications where 50%
RH is considered toodry
Humidity set to 70% RH; ideal for unoccupied properties or where economical
runis needed without the need to go drier than 70% RH.
Other features and Indicators
Tank Full Light
The light will be on and the unit will beep when the tank is ready to be
emptied, or when the tank is removed or not replaced in the proper position.
The water level control switch shuts off the dehumidifier when the tank is
full, or when the tank is removed or not replaced in the proper position.
Empty and replace to resume operation.
Auto Defrost
The appliance will defrost automatically as programmed once the coil sensor
detects that the temperature is too low, the fan speed is default to MAX speed
and the defrosting indicator will light up in the process of defrosting. If
the previous mode is SMART/SLEEP/ LAUNDRY, the appliance will recover to its
previous running mode once defrosting has finished. If the previous mode is
Deh. , the fan speed will become MAX speed after the defrosting unless the
user adjust the fan speed.
Humidistat control and fan/ compressor operation
When the selected humidity is 2% lower than the user selected humidistat
setting; the dehumidifier’s compressor will be shut off automatically.
‘When the humidity is equal or higher than user selected humidity the
compressor will restart once the 3minutes delay compressor protection expires.
Auto-Restart
If the unit stops off unexpectedly due to the power cut, it will restart with
the previous function selected automatically when the power resumes.
Power
After the unit has stopped, it is not recommended to resume operation for at
least 10 minutes. This is to protect the compressor. Operation can resume
after this period lapses. When the unit is restarted there is a 3 minutes
delay before the compressor will start.
Lightweight Portable Design on castors
The dehumidifier is built to be compact and lightweight. The castors on the
bottom of the unit make it easy to move from room to room.
Your MORRIS dehumidifier is an advanced micro-CPU controlled device able of
self- diagnostics. The LCD display may also show the error and protections
codes.
Positioning the dehumidifier
A badly positioned dehumidifier will have little effect. In positioning the
dehumidifier please ensure circulation of air in not restricted around the
unit.
Allow at least 20 cm space around the unit.
This dehumidifier is designed
only for indoor residential / small office applications and any commercial or
industrial use will invalidate the warranty.
Use in an enclosed area for maximum efficiency.
Close all doors, windows to create an effective operating environment. Do not
use outdoors. your dehumidifier will begin to protect your space from the
harmful effects of excessive moisture as soon asit is turned on. Excess
moisture is dispersed throughout your home. For this reason, the dehumidifier
should be positioned in a central and clear location so that it can draw this
moist air towards it from all over the home. A warm hallway or landing is an
excellent position for your dehumidifier. If possible, leave interior
doors ajar to allow air circulation.
Alternatively, if you have a serious problem in one area you can begin by
positioning the dehumidifier there and moving it to a more central location at
a later date. For the most effective use, run your dehumidifier with external
doors and windows kept closed. Please note the unit should not be placed
directly against a radiator or other heat source.
When positioning your dehumidifier, ensure that it is placed clear of any
obstacle that may limit the air movement. Place the dehumidifier on a flat dry
surface.
Note: Do not force castors to move over carpets or uneven surfaces, nor
move the unit with water in the tank as it may tip over and spill water.
Water Drainage
When the water tank is full, the unit will stop automatically. When this
happens the tank full light will show on the control panel.
Note: Only empty the water tank when it is full or before moving or storing
the unit.
There are two ways to dispense collected water.
Use the tank
‘When the tank is full the unit will automatically stop running, and the Full
indicator light will flash.
Slowly pull out the tank. Grip tank by its handle securely, and carefully pull
out. Empty the water tank and reinsert it into the dehumidifier. The tank must
be in place and securely seated for the dehumidifier to operate again.
The dehumidifier will re-start when the tank is restored in its correct
position.
NOTES:
‘When you remove the bucket, do not touch sensors or any parts which are
situated behind the tank. Doing so may damage the product. Be sure to push the
tank gently all the way into the unit. Banging the bucket against anything or
failing to push it in securely into place may cause the unit to not operate.
Do not remove any parts from the water tank or tank enclosure. The water full
sensor will no longer be able to detect the water level correctly and water
may leak from the water tank.
2.CONTINUOUS DRAINAGE OPERATION
Your device has a drainage port that allows you to have continuous drainage.
Connect a 10mm diameter PVC pipe (provided in the package) with the drainage
port located on the back part of the unit, for continuous drainage purposes,
as below figure. Ensure the hose is directed downwards, allowing water to flow
by gravity to an external drain. Ensure that the end of the hose is lower than
the drain opening, otherwise the water will not drain and flooding may occur.
Make sure the connection
between pipe and the drain outlet is tight and does not leak. Then direct the
pipe to a suitable drainage point. This unit uses gravity fall to dispose
water hence the drain should be lower than the unit water outlet. Put the tank
back. Be sure to run the water pipe downward and let the water to flow out
smoothly. Do not kink or bend the pipe.
NOTE: When the continuous drain feature is not being used, remove the
drain hose from the outlet.
The permanent drain can be used in conjunction with a water pump(e.g. when
draining a cellar) to lift the water upwards.
Care and Maintenance
Always shut off the unit and unplug from the mains before cleaning or
performing any maintenance. When it is not in use for long periods it is
advisable to remove the plug from the power socket. Do not use chemical
solvents (such as benzene, alcohol or gasoline) as they may cause irreversible
damage to the unit. 1.Clean the Grille and Case Use water and a mild detergent
to clean the washable mesh filters.
Do not use bleach or abrasives.
Do not splash water directly onto the main unit. Doing so may cause an
electrical shock and can lead to the insulation to deteriorate, or cause the
unit to rust. The air intake and outlet grilles get soiled easily, so use a
vacuum attachment or soft brush to clean. Wipe the dehumidifier body with a
soft damp cloth or kitchen towel.
Remove the ABS frame and pull out the filters from the frame. Hoover gently
the HEPA and carbon filter once every 2-3 weeks approximately.
If the mesh filter is dirty hoover it, if it is heavily soiled wash it with
warm soapy water and dry thoroughly before reinserting it in the unit.
When filter cleaning is finished and filters are dry placed them back into the
filter frame and reassemble the unit.
NOTE: While the HEPA and carbon filter is of optional usage never run the
unit without the mesh filter frame being assembled back.
2.Clean the water tank
Every few weeks, clean the tank to prevent growth of mould, mildew and
bacteria.
Partially fill the tank with clean water and add a little mild detergent.
Swish it around and then empty the tank and rinse.
NOTE: Do not use a dishwasher to clean the tank. After cleaning and
drying the tank must be reinserted securely into dehumidifier in order to
restart operation.
End of Season Maintenance:
- Empty and clean the water tank.
- Clean the unit and the filters as per the cleaning procedure above.
- Coil the power cord on the special cord storage rest at the back of the unit
- Cover the unit and keep it in a dry place.
Frequently Asked Questions
Why doesn’t the dehu r seem to extract much water if the temperature is
low?
This is acompressor dehumidifier which works best in temperatures above 15 °C.
If the temperature is low and the air is dryer than the setting on the
humidistat the unit will not extract water. If you want to use a dehumidifier
for outside buildings, unheated properties, boats or garages please check our
desiccant range.
Why doesn’t the unit work /or stops suddenly?
The water tank may be full or displaced. To rectify: empty the tank and
carefully place the tank back in the unit. Also the unit may be running in
dehumidifying mode with a low room temperature. Please check if the room
temperature is lower than 5 °C. If so, the unit will stop working while in
dehumidifying mode. (unit may be defrosting).
The ambient operating range is between 5 °C and 35 °C with a relative humidity
ranging from 30% to 80%. For maximum efficiency use the unit between 15 °C and
32 °C.
Sometimes cold and/or hot air comes out from the air outlet grill, why?
When the unit is in dehumidifying mode it absorbs humid air from room and
freezes it to reduce the humidity.
During the cold cycle there should be cold air coming out of the unit During
the hot cycle hot dry air should be coming out of the outlet grill.
Troubleshooting:
Issue | Cause | Solution |
---|---|---|
Hot or cold air being produced | Normal Operation | When the unit is in |
dehumidifying mode it absorbs humid air from room and freezes it to reduce the
humidity. During the cold cycle there should be cold air coming out of theunit
Diming the defrost cycle hot dry air shoukl be coming out of theoutlet grill.
Unit does not operate| Is the plug properly inserted in the socket?| Insert
the plug into the socket and turn the switch on.
Is the tank full indicator lit?| Tank full. float displaced or tank not
properly inserted. Empty tank. check float and make sure the tank is properly
inserted in unit.
Front louvres do not open| Louvre motor is blocked| Check if anything is
blocking the louvre.
Try to move gently the louvre up and down while the unit if off. If the above
fails return the unit to a service centre.
Dehumidifier does not extract water| Is the unit set to a humidity level lower
than the one in the room?| Set the humidity level on the humidistat bellow
current humidity reading.
Is the temperature too low for water extraction to be
efficient?| Increase the temperature in the room or reposition the unit.
Is any intake grill or discharge blocked? Is the unit too close to walls?|
Removeobstructionsand restart the unit. Ensure a distance of at least 20cm
between the unit & walls
Airflow seems weak| Is filter dirty or clogged?| Please service the filters
regularly as per user manual.
Unit is noisy during operation| Is the unit on uneven surface?| Please place
on flat horizontal surface.
Is filter clogged?| Please service the filters regularly as per user manual.
E3or E4| Humidity sensor error| Use the unit within the prescribed humidity
range. Unplug the unit. rest and plug it back in. If error repeats. call a
service centre.
El or E2| Temperature sensor error| Use the unit within the prescribed
temperature range. Unplug the unit. rest and plug it back in. If error
repeats, call for service centre.
E5 or E6| Abnormal Coil
sensor temperature or current| Use the unit within the prescribed humidity
and temperature range. Unplug the unit, rest and plug it back in. If error
repeats, call for service centre.
Defrost light on and unit stops
regularly| Unit is defrosting| Allow the unit to automatically defrost. The
protection will clear after the unit self defrosts. Increase temperature in
the room if this repeats too often
Tank full light| Water tank full notification| Tank is full or is not in the
right position– Empty the tank and replace in the right position.
Any other malfunctions will need to be reported to the service centre. Do not
attempt unauthorised repairs as these may invalidate the warranty.
PRODUCT REPAIR
Warning: The appliance should be stored in a well-ventilated room. The
area of the room should be equal to the room area required for maintenance.
——Warning: Appliances should be stored in rooms where there is no continuous
burning fire (such as ignited gas appliances) and ignition sources (such as
electric heaters at work)
-——All operators or refrigeration circuit maintenance personnel should obtain a valid certificate issued by an industry-approved assessment agency to determine their qualification for safe disposal of refrigerants as required by the industry-approved assessment specification.
-——The maintenance and repair of the equipment can only be carried out according to the method recommended by the equipment manufacturer. If other professionals are required to assist in the maintenance and repair of the equipment, they should be supervised by personnel qualified to use flammable refrigerants.
A1 Inspection of the site
Prior to servicing with flammable refrigerants, a safety inspection must be
performed to ensure that the risk of fire is minimized. When servicing the
refrigeration system, the following precautions should be observed before
handling the system.
A.2.Operating procedure
Work should be performed under controlled procedures to ensure that the risk
caused by combustible gases or vapors during operations is lowest
A.3.General working area
All maintenance personnel and other personnel in the work area should be aware
of the nature of the work being performed and should work within a confined
space that should be avoided. The work area should be properly segregated to
ensure the safety of working conditions in the work area by controlling
combustible materials.
AA4.Checkif the refrigerant is present
Pre-operation and during operation should be monitored in the area using an
appropriate refrigerant monitor to ensure that the technicians are aware of
the presence of potentially flammable gases and that all leak detection
equipment is suitable for flammable refrigerants, such as: no spark, fully
enclosed Or intrinsically safe
A.5.Fire extinguisher placement
When performing heat-processing operations on the refrigeration system or
related components, the appropriate fire extinguisher should be located nearby
and the refrigerant injection area should be equipped with a dry powder or
carbon dioxide fire extinguisher.
A.6.Prohibition of fire
When working in connection with exposed pipelines that contain or have
contained flammable refrigerants, all forms of ignition sources that may cause
fire or danger to the station should not be used. All sources of ignition,
including smoking, are combustible The agent may be released into the
surrounding environment. It must be far away from the area where it is
installed, repaired, relocated or disposed. Before starting work, the
surrounding environment of the equipment must be inspected strictly to ensure
that there is no danger of flammability or fire,should set up the mark of “No
Smoking “.
A7.Ventilated area
Ensure that the work area is open or fully ventilated before opening the
system or performing hot work operations. Ventilation should be maintained
during operation. Ventilation will safely dilute the leaked refrigerant and
quickly release it into the atmosphere.
A.8. Inspection of refrigeration equipment
If you replace electrical components, these electrical components should be
installed in accordance with the day-to-day and night-time operating
regulations. At all times, the manufacturer’s maintenance and repair guides
should be followed. If in doubt, consult the manufacturer’s technical
department.
The following inspection items apply to the installation of flammable
refrigerant appliances:
-The charge should be determined according to the size of the room containing the refrigerant containing components;
– Ventilation equipment should operate normally and vents should be free from
obstructions;
– If an inter-refrigeration refrigeration cycle is used, check the presence of
refrigerant in the secondary circuit;
-The logo on the appliance should be clearly visible. Marks and symbols that are indelible;
– Refrigerating lines or electrical components should not be installed in
environments that contain possible housing contact elements ,unless the
electrical components are made of corrosion-resistant materials or suitable
corrosion protection measures are taken.
A.9.Inspection of Electrical Installations
The repair and maintenance of electrical components should include initial
safety inspections and component inspection procedures. If there is a defect
that compromises safety, the appliance power supply must be de-energized until
the defect is properly disposed of. If the defect cannot be completely
eliminated in the end, and must continue to operate, then appropriate
temporary solutions should be taken, report the situation to the owner of the
appliance, and warn all relevant personnel.
The initial security check should include:
– Capacitor discharge should be performed in a safe manner to avoid sparks
– No exposed electrical components and wiring during filling, recycling and
cleaning of the system
– Continuity of grounding
B.Maintenance of sealing elements
B.1 When repairing closed components, disconnect the power supply of the
device before opening the sealed cover. If there is power supply during the
maintenance process, uninterrupted leak detection should be performed on the
most dangerous parts to prevent potential dangerous situations from occurring.
B.2 In the following maintenance of electrical components, special care shall
be taken not to cause maintenance methods affecting the degree of protection
of the enclosure. Improper maintenance may result in damage to the cables,
excessive connection, improper installation of the terminals, damage to the
seals, and sealing. Cover installation error and other hazards
Ensure the installation of the equipment is safe and reliable
Ensure that the sealing or sealing material does not lose its effect of
preventing the entry of flammable gases due to aging, and the replacement
parts should comply with the manufacturer’s specifications
Note: The use of silicon-containing sealants may reduce the detection
capabilities of leak detection equipment, intrinsically safe components do not
have to be isolated before operation
C.Intrinsically safe component maintenance
If it cannot be ensured that the appliance does not exceed the limits of the
allowable voltage and current during use, no permanent inductance or
capacitive load must be used in the circuit.
The essential Ankh-type element is the only element that can continue to
operate within the flammable gas. The test instrument should be set in the
correct gear.
If the replacement component can only use components specified by the
manufacturer, other ccomponents may cause the refrigerant that is leaking in
the air to catch fire.
D.Cable
Check the cable for wear, corrosion, overpressure, vibration, sharp edges or
other adverse environmental effects. This inspection should aiso consider the
impact of aging or the continuous vibration of the compressor and fan on the
cable manufacturing.
E. Inspection of flammable refrigerants
Inspection refrigerant leakage should be done in an environment where there is
no potential source of ignition and should not be detected using a halogen
probe (or any other detector using an open flame)
F.Leak detection method
For systems containing flammable refrigerants, the following methods for
detecting leaks are acceptable:
Electronic leak detectors can be used for the detection of flammable
refrigerants, but the sensitivity may not be sufficient or may require
recalibration (the instrument calibration should be performed in a
refrigerant-free environment) to ensure that the leak detector does not become
a potential The ignition source, and applies to the measured refrigerant, the
leak detector should be set to the lowest flammable concentration of the
refrigerant (in percent), calibrated with the used refrigerant and adjusted to
the appropriate gas concentration test range (max. 25%)
The leak detection fluid is suitable for most refrigerants, but do not use
oxygenated solvents to prevent oxygen and refrigerant from reacting and
corroding the copper pipeline If leakage is suspected, all open flames should
be removed from the site or extinguished If a leak occurs where welding is
required, all refrigerant should be recovered, or the refrigerant should be
completely isolated away from the leak (using shut-off valves). Before welding
and during welding, use oxygen-free. Nitrogen (OFN) purifies the entire system
G.Remove and vacuum
When performing maintenance or other operations on the refrigeration circuit,
routine procedures should be followed, but the flammability of the refrigerant
should also be considered. Follow these procedures:
-Clear refrigerant
-Purge the line with inert gas
-Vacuum
– purge the pipe again with inert gas
– cutting pipelines or welding
Refrigerant should be recycled to a suitable storage tank. The system should
be purged with oxygen-free nitrogen to ensure safety. This process may need to
be repeated several times.
This operation must not be performed with compressed air or oxygen.
In the purging process, the system is filled with oxygen-free nitrogen to
reach the working pressure under the vacuum state, and then the oxygen-free
nitrogen is discharged to the atmosphere. Finally, the system is evacuated to
a vacuum, and the process is repeated until the refrigerant in the system is
completely removed. After the last charge of anaerobic nitrogen, the gas is
released to atmospheric pressure and the system can then be welded. Such as
pipe welding operations, the above operation is very necessary
Make sure there are no ignition sources near the outlet of the vacuum pump and
that it is well ventilated.
H. Charge the refrigerant program
As asupplement to regular procedures, add the following requirements:
-Ensure that when using the refrigerant charging equipment, no inter-contamination between different refrigerants will occur, and the piping for charging the refrigerant should be as short as possible to reduce the residual amount of refrigerant therein
-Tanks should be kept vertically upward
– Ensure that the cooling system has been grounded before filling the
refrigerant
– Label the system after filling (or when it has not been completed)
– Must pay attention not to overcharge
The pressure test was performed with oxygen-free nitrogen before recharging
the system.
After the filling was completed, a leak test was performed before the test
operation. A leak test should be conducted when leaving the area
I. Retired
Before proceeding with this procedure, technicians should be fully familiar
with the equipment and all its features and recommend the practice of safe
recovery of refrigerants. To recycle the recovered refrigerant, analyze the
refrigerant and oil samples before performing the work. Before testing, ensure
that you have the necessary power supply.
a> Familiar with the equipment and operation
b> Disconnect the power
c> Before proceeding with this procedure, ensure that:
– If necessary, mechanical operating equipment should facilitate the operation
of refrigerant storage tanks
– All personal protective equipment is effective and can be used correctly
– The entire recycling process should be conducted under the guidance of
qualified personnel Recycling equipment and storage tanks should meet the
appropriate standards
d> If possible, vacuum the cooling system
e> If the vacuum state is not reached, extraction should be performed from
multiple places to extract the refrigerant in each part of the system
Ensure that the volume of the tank is sufficient before beginning recovery
g> Start and operate the recycling equipment according to the manufacturer’s operating instructions
h> Do not talk about tanks being overfilled. (Liquid injection volume does not exceed 80% of the tank volume)
i> The maximum working pressure of the tank must not be exceeded even for a short period of time
j> After the tank filling is completed and the working process is completed, ensure that the tank and equipment are quickly removed and all shutoff valves on the equipment are closed
k > The recovered refrigerant must not be injected into another refrigeration system until it has been purified and tested
J.Recycling
The refrigerant in the system needs to be removed during maintenance or scrap. It is recommended that the refrigerant be completely removed.
When loading the refrigerant into the tank, use only a dedicated refrigerant tank. It is necessary to ensure that the capacity of the tank is compatible with the amount of refrigeration injection in the entire system. All are tanks intended to be used for refrigerant recovery and are identified with this refrigerant (ie refrigerant recovery dedicated tanks). Tanks should be fitted with pressure relief and shut-off valves and in good condition. If possible, empty storage tanks should be evacuated and kept at room temperature before use.
The recovery equipment should maintain a good working condition, and the equipment operation instructions should be provided for easy reference. The equipment should be suitable for the recovery of flammable refrigerants. In addition, there must be qualified weighing instruments that can be used normally. The hose should be connected using a leak- free, releasable joint and keep it in good condition. Before using the recycling equipment, check whether it is in a good condition, whether it is well maintained, and all the electrical components are sealed to prevent the fire from leaking once the refrigerant leaks. If in doubt, consult the manufacturer.
Recovered refrigerant should be contained in the used storage tank, attached with shipping instructions and returned to the chiller manufacturer. Do not mix the refrigerant in the recovery equipment, especially the storage tank.
If you remove the compressor or remove the compressor oil, make sure that the compressor is evacuated to a suitable level to ensure that there is no residual flammable refrigerant in the lubricant. Evacuation is performed before the compressor returns to the supplier. Only use electric heating to heat the compressor housing to speed up this process. When the oil is discharged from the system, safety should be ensured.
Technical data
Model No.: | MDP-25600INV |
---|---|
Dehumidify capacity: | 25L/DAY (30°C RH80%) 14L/DAY (26.7°C RH60%) |
Rated Voltage: | AC 220-240V |
Rated Frequency: | 50Hz |
Max. power input | 350W |
Rated Input power: | 245W |
Tank Capacity: | 5L |
Air Volume: | 210/180/145m°/h |
Noise Level: | 35dB(A) |
Refrigerant : | R290/110g |
Net weight: | 13.3kgs |
Suction pressure: | 0.7Mpa |
Discharge pressure: | 3.2Mpa |
NOTICE ABOUT RECYCLING
**** Your product s designed and manufactured with high quality materials and
components which can be recycled and reused.
This symbol means that electrical and electronic equipment, at their end-of-
life should be disposed of separately from your household waste.
Please dispose of this equipment at your local community waste collection/
recycling centre.
In the European Union there are separate collection systems for used
electrical and electronic products.
Please help us to conserve the environment we live in!
DECLARATION OF CONFORMITY
** Herewith, we state that this product, complies with the requirements of
below directives:
EMC-Directive: 14/30/EU
Low Voltage Directive: 14/35/EU
ROHS directive: (EU)15/863
CE Marking: 93/68 /EEC
The detailed declaration of conformity can be found at
www.morris.gr
WIFI INSTRUCTIONS MANUAL BEFORE YOU START**
- Ensure your router provides a standard 2.4ghz connection.
- If your router is dual band ensure that both networks have different network names (SSID).
- The provider of your router / ISP will be able to provide advice specific to your router.
- Place the dehumidifier as close as possible to the router during setup.
- Once the app has been installed on your phone, turn off the data connection, and ensure your phone is connected to your router via wifi.
DOWNLOAD THE APP TO YOUR PHONE
Download the “TUYA SMART LIFE” app, from your chosen app store. Alternatively,
you could also download the “TUYA Smart” app which is also compatible, but has
some slight differences in the layout.
REMARK: Alternatively, you can use the TUYA Smart application, which has a
similar layout and functions
REGISTER THE APP
- Click on the register button at the bottom of the screen
- Press “Agree” to the Privacy Policy.
- Enter either your mobile phone number or email address to receive a verification code, and press next
- 0nce you have received the verification code, enter it and create a password in the lower box before pressing confirm.
Remark: the verification code shall be sent to you either by sms or by e-mail message, depending on the registration method you have selected above.
CONNECTION METHODS AVAILABLE FOR SETUP
This smart device has two different setup modes, “Add Manually” and “Search by
Device” Before starting the setup, please ensure that your dehumidifier is
placed as close as possible to your wifi-router.
ENTERING CONNECTION MODE
To enter connection mode on your dehumidifier, press and hold WIFI button for
3″ until you hear the sound. The WIFI indication will start flashing
CONNECTING THROUGH THE “ADD MANUALLY” TAB
Before initiating the connection, make sure the WIFIis ON and that the relative indication is flashing. If not, press again and keep pressed for 3 seconds the WiFi button, while also ensure your phone is connected to the wifi network.
- Open app and click “+” to add device
- Tap on the top left the “Add Manually” option. On the left side scroll down to “Small Home Appliances. Select the type of device as “Dehumidifier”
- Ensure the wifi light on the dehumidifier is flashing quickly (if not, hold the wifi button for 3 seconds, then press the button at the bottom of the screen to confirm.
- Select your home network, enter your wifi password and press confirm.
- This will then transfer the settings to the dehumidifier. Wait until the connextion has been completed succesfully. If the connection fails, retry. If the connection is still failing please review the troubleshooting section for further help.
Once the connection has been completed, your device will appear on the screen. Press DONE button to complete the process.
CONNECTING USING THE “SEARCH FOR DEVICE” TAB
Before initiating the connection, make sure the unit is switched on, with the
connection light flashing. If not, press the WiFi button again and keep it
pressed for 3 seconds, while also ensure that your phone is connected to the
wifi network.
-
Turn on Bluetooth.
-
Ensure the connection light on the dehumidifier is flashing. Add discovering device.
-
Click “+” to add device. Make sure that access location is enabled.
-
You should be seeing the name of your home network, to which your mobile device should already be connected as well. Enter the password in the relative field and press Confirm. Important:Only 2.4GHz Wi-Fi networks are supported.
-
The connecting of the device will start.
If this fails, retry. If the connection is still failing review the trouble shooting section help. -
Once the connecting is completed, press the “Done” button to complete the linking.
CONTROLLING YOUR DEVICE THROUGH THE APP
Now that your dehumidifier is linked up to your network, you can control it
from your phone.
From the main control screen you can turn your device on and off by sliding on
the power icon on the upper side of the device.Press the top left button to go back to the last page.There are
four tabs at the bottom of the main menu of the application allowing you to
swap between Home, Scene, Smart, Me options Press the button on top right to enter the Device Details Page
PROFILE TAB
The profile tab gives you the option to edit both your details, and use the
added features of the unit.
When further settings can be set, three dots appear on the screen (…)
CHANGING THE NAME OF YOUR DEVICE
Tap on the pencil icon on the top right corner.
The top option allows you to change the name of the device to something
relevant to the use of the product.
Click “Location” and assign a
location to the dehumidifier. Example: Bedroom 1, Dining Room etc. and tap
save.
Use the arrow on top left to return to the operation screen.
SHARE DEVICE
This allows you to share access to the controls of your dehumifier with
friends and family.
DEVICE SHARING SET UP
The person you add will need to have the TUYA’s APP installed on their phone.
Open the APP and choose the appliance. Tap the ‘pen’ icon in the top right
corner of the screen.
Tap ‘Share Device’ to enter the number of the person you want to include or
tap the phone icon to select the persons phone number from your contacts.
Tap “Confirm” to complete the addition.
REMARK: The invitation for the
device sharing must be sent to the details of an existing registered user at
TUYA Smart Life.
DEVICE SHARING CANCELLATION
Tap ‘Shared Devices’ to delete the number of the person you want to cancel Tap
“Confirm” to complete the addition. here can only be one user operating the
dehumidifier at a time. The APP needs to be closed on all other devices to
enable the sharing to work.
NOTE: If someone else sets up
their phone on the same dehumidifier without using the “Share Device” ,the
original phone will be disconnected and the dehumidifier will disappear from
the device
Open the “TUYA SMART LIFE” APP to select the dehumidifier (when using one
mobile phone to control multiple appliances, you need to select the
dehumidifier to be operated).
There are two ways to turn on/off the dehumidifier.
- Press the power button and the button color changed to green, it indicates that the dehumidifier on.
- Press power button again to turn off the dehumidifier.
Select the dehumidifier to be operated and enter the operation interface.
If the power slider is
highlighting OFF, this indicates that the dehumidifier is in the OFF/Standby
setting.
- Tap the ON icon and the dehumidifier will turn on.
- You can now control the dehumidifier.
- To turn the dehumidifier off again tap the OFF icon and the dehumidifier will revert to the dark screen.
HUMIDITY SETTING:
The required humidity can be set from 35-80%.
Tap the ‘Set Humidity’ button and then scroll through to set the required
humidity then press OK to return to themain screen.
When the set humidity is lower than
the relative humidity, the dehumidifier begins to operate.
If the set humidity is above the relative humidity the dehumidifier will be in
standby mode and will not operate until the relative humidity increases above
the set humidity.
The current humidity is shown on the left of the main screen. The current room
temperature is displayed at the bottom of the screen. MODE
Mode can be set to Smart, Deh., Fan, Laundry.
Press the ‘Mode’ icon to set the
required operating mode.
Smart Mode : Maintains the room at an ideal domestic environment humidity
of 55% relative humidity (RH) while saving electricity. The compressor will
work until the desired humidity is reached and will then stop.
The desired humidity cannot be changed in this mode.
Deh.Mode: in Deh. mode, the
humidity can be adjusted in the range of 35%-80%, and the operation of high,
mid or low wind can be adjusted at the same time. FanMode: This mode only uses
the fan-No moisture will be extracted while this mode is in operation.
Filters like the “UV” and “ Plasma loniser” can be used in this mode to
improve the quality of the air processed and emitted through the unit. The
operation of high, mid or low wind can be adjusted.
Laundry Mode: quick drying mode. In this mode, the default humidity of the
machine is 35%. The machine will not stop until the water is full or the
function is tumed off.
SPEED BUTTON:
Pressing this button to change the wind speed in the Deh. Mode and Fan Mode.
IONIZER BUTTON (Plasma lonisation Function)
Pressing this button turns on the “Plasma lonizer” function. The ionizer
can refresh the air while killing viruses, dust mites, mould, and airborne
allergens.
To turn off this function, press
the button again.
UV BUTTON(for Air Purification)
Pressing this button turns on the “UV” function.
The germicidal UV light improves the air quality by destroying germs,
bacteria, and fungi
To turn off the “UV”, press the
button again.
HUMIDITY INDICATOR
This turns the colour changing humidity indicator on the front of the unit on
and off. The indicator will turn on automatically when the appliance is turned
on.
You can turn off the light by pressing the Humidity Indicator Button and enter
the device in SLEEP mode.
‘OSCILLATING BUTTON
Press this button to turn on the “OSCILLATING” function,
To turn off this function, press the button again.
SLEEP BUTTON
Press the SLEEP button to activate the SLEEP mode.
The indicator light will illuminate.
Press the SLEEP button again to quit the SLEEP mode, then the device will work
as per the last setting before the SLEEP mode.
CHILD LOCKBUTTON
Press this button to enter the child lock mode, the child lock indicator
lights up, and all touch button touches are invalid; after pressing this
button again, the child lock indicator light is off, and all touch button
touches are effective again. TIMER (SCHEDULE)
In the main APP screen, scroll down to find the Schedule button under the
dehumidifier controls.
Press this button to set smart timer.
The timer in the APP has far more functionality than the timer button on the
unit.
Press the button to add a ‘Schedule’, then press “Add Schedule’ at the bottom.
Select whether you want the unit to turn Off for On.
You can then set down to the minute when you want the unit to turn off or on.
You can also set the timer to
‘Repeat’ the operation for specific/multiple days.
When you have finished your desired settings, press ‘Save’ to confirm and go
back to the main APP screen.
You can also set up a Timer Schedule when the unit is in the Off/Standby
setting.
Press Schedule and follow instructions above.
To remove a set schedule, if you have Android long press on the schedule,
while in I0S slide left and press ‘ Delete’ when the confirmation prompt comes
up.
Important Note: Make sure the Smartphone or Tablet Clock that you are
using has the right time you are providing from the connection network to the
Internet. Possible delay or non-activation of the timer maybe caused by an
incorrect time setting on the device you are using.
ADDING ADDITIONAL DEHUMIDIFIERS
YYou have the ability of adding additional devices to be controlled by this
application. This feature is particularly convenient in case you have more
than one of our dehumidifiers, orin case you have other TUYA powered smart
appliances in your possesion, since it allows you to control them all at the
same time.
From the “Devices” page of the APP
press add device symbol “+” on the top right corner and follow the below
listed steps to pair the new appliance.
Choose/confirm which WiFi to connect to.
Note: your phone may pick up other WiFi signals(eg.neighbours) so you
will need to choose. Make certain that the device to be
added is already in “Wifi connectivity” status. In case of a MORRIS
dehumidifier, revert to the connectity section in the previous pages. In case
of another TUYA powered smart device please revert to its own connectivity
manual.
The phone will now connect to the dehumidifier. Ensure you have a good strong
signal from your WiFi router.
Note: The Wii indicator on the
dehumidifier screen may disappear during this pairing process. Once complete
the screen showing the device has been successfully added will appear.
Rename the dehumidifier if desired.
Tap “Done” to continue.
Your Devices list will then show the additional dehumidifier that you have
paired
TROUBLESHOOTING
- Check whether the device is powered on and is in the correct standby mode, if not please refer to the Changing between connection types section.
- Ensure the wifi password has been entered into the app correctly ( Case sensitive)
- Check that the phone is connected to the wifi you are connecting the device to.
- Ensure the network you are connecting it to is 2.4Ghz (5Ghz wifi networks are not supported), and that there is a strong wifi signal to the item.
- Check the settings on the router. Encryption should be WPA2-PSK and authorisation type should be set to AES
- If you are unable to connect through the quick connection method, please try following the guide for connecting the AP Mode.
DISCLAIMER:
All above instructions and illustrations are offered based upon the layout of
TUYA’s Smart Life application at the date of publishing.
Actual layout of the application, its graphics, or exact menus at the time of
installation may differ.
This is the result of the applications constant updating so as to improve the
user experience, resolve potential bugs, or even add more features.
In case of any difficulty, please check our web-page for an updated version,
or contact our after sales department.
Exclusive Distributor
Amiridis-Savvidis S.A.
87A, 17is Noemvriou Str
P.C.55535 | Pylea | Greece T: 2310 944944
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>