Johnson Controls LC-200S IR Detector Instructions

June 16, 2024
Johnson Controls

Johnson Controls LC-200S IR Detector

Johnson-Controls-LC-200S-IR-Detector-product-image

Specifications:

  • RANGE: 12 m (40 ft)
  • HORIZONTAL COVERAGE: 1100mm (3333ft)
  • ALARM DURATION: 2 s
  • SELF-DIAGNOSTICS: –
  • LED WALK TEST MICROWAVE FREQUENCY SOLID STATE RELAY: YES
  • EOL RESISTANCE: YES
  • CREEP ZONE DEVICE: YES
  • CASE TAMPER: YES
  • BACK TAMPER: NO
  • ANTI-MASKING PULSE COUNTER: –
  • RFI PROTECTION: 30 V/m
  • HEAT COMPENSATION: YES
  • FULLY DIGITAL SWIVEL OPTION POWER SUPPLY: YES
  • COVER MATERIAL: ABS
  • PET IMMUNITY: YES
  • OPERATING TEMPERATURE: 22.1°C (71.8°F)
  • HUMIDITY: 93% RH
  • DIMENSIONS: 114 x 63 x 40 mm

Product Usage Instructions

  1. Introduction:
    The LC-200S is an IR detector equipped with white light protection, digital signal analysis, high RFI protection, and pet immunity up to 15 kg.

  2. Installation:

  3. Using a thin screwdriver, loosen the bottom screw and open the cover.

  4. Remove the board from the base by levering the ABS cover.

  5. Drill the stopper on the base of the cover at the desired fastening location (or use the optional swivel that is not IMQ certified).

  6. Recommended height is 2.1 m.

  7. Slide the cable in through the back slot and out the top hole.

  8. Wire the terminals following the connections shown in Connection and Setup.

  9. Connection and Setup:
    Follow the instructions below for connection and setup:

    • Jumper PULSE: closed = 2 pulses; open = 1 pulse
    • Jumper LED: closed = LED ON; open = LED OFF
    • Jumpers T – A – EOL open = NC contacts without resistors (not for UL/ULC applications)
    • Jumpers T – A – EOL closed = DEOL supervision with internal resistors
    • SUPPLY: power supply 9-15 VDC / 25 mA. Note: For UL/ULC installations, the detector shall be provided with a minimum of 4 hours of standby power from either a listed compatible control unit or power supply. Use only resistive loads on the outputs.

FAQ:

  • Q: What is the range of the LC-200S detector?
    A: The range of the LC-200S detector is 12 meters (40 feet).

  • Q: Does the LC-200S have pet immunity?
    A: Yes, the LC-200S is immune to pets weighing up to 15 kg.

  • Q: What is the operating temperature of the LC-200S?
    A: The operating temperature of the LC-200S is 22.1°C (71.8°F).

LC-200S IR DETECTOR

INTRODUCTION

  1. LC-200S is the detector for all security installations needing an excellent product that is easy to install, suitable for any residential installation and does not require special attention for programming. No special care is required for the detector. It can simply be installed and turned on.
  2. LC-200S detectors are equipped with lenses designed by Johnson Controls and are manufactured by Fresnel Technologies, Inc.
  3. LODIFF® optic creation technology combined with POLY IR® materials make it a product of the highest quality and efficiency.
  4. LC-200S detector is pet immune (feature not evaluated by UL/ULC) and has a 12 m (40 ft) range at a 100-degree angle.
  • White Light Protection
    The detector digitally filters white light components.

  • High RFI Protection
    The detector has very high RFI immunity due to the complete lack of traditional amplifiers.

  • Ultraviolet Stabilization POLY IR®4 Lens Material

    • The lens is printed with POLY IR® material.
    • This materials offers a better combination of transmittance, environmental stability and color than any other polymer on the market. Materials are available for the 8-14 micron infrared region. LODIFF® and POLY IR® are registered trademarks of Fresnel Technologies, Inc.
  • Digital Signal Analysis
    This detector is equipped with a traditional PIR with a processor that converts the analysis into digital format for optimum performance in all situations.

  • Pet Immunity
    Thanks to a new lens design and the digital analysis system, all of our detectors are immune to pets weighing up to 15 kg.

  • LODIFF® Fresnel Lens Technology

    • This lens series is made by tiling LODIFF® lens pieces.
    • These lenses offer significantly improved performance over the typical constant-bandwidth Fresnel lens. LODIFF® and POLY IR® are registered trademarks of Fresnel Technologies, Inc.

INSTALLATION

  • Using a thin screwdriver, loosen the bottom screw and open the cover (see Fig 1)
  • Remove the board from the base by levering the ABS cover (see Fig 2)
  • Drill the stopper on the base of the cover at the desired fastening location (or use the optional swivel that is not IMQ certified)
  • Recommended height is 2.1 m
  • Slide the cable in through the back slot and out the top hole
  • Wire the terminals following the connections shown in “Connection and Setup”

Johnson-Controls-LC-200S-IR-Detector-01 \(8\)

NOTE: Do not partially or completely cover the detector’s field of vision NOTE: the pet function is not IMQ certified

CONNECTION AND SETUP

  • Jumper PULSE: closed = 2 pulses; open = 1 pulse
  • Jumper LED: closed = LED ON; open = LED OFF
  • Jumpers T – A – EOL open = NC contacts without resistors (not for UL/ULC applications)
  • Jumpers T – A – EOL closed = DEOL supervision with internal resistors
  • SUPPLY: power supply 9-15 VDC / 25 mA. Note: For UL/ULC installations the detector shall be provided with minimum of 4 hours of standby power from either a listed compatible control unit or power supply. Use only resistive loads on the outputs. Johnson-Controls-LC-200S-IR-Detector-01 \(10\)

Technical Characteristics

Technical Characteristics|
---|---
RANGE| 12 m (40 ft)
HORIZONTAL COVERAGE| 100°
LENSES| LODIFF® Fresnel Lens POLY IR®4 material
LED| red
ALARM DURATION| 2 s
SELF-DIAGNOSTICS| –
LED WALK TEST| YES
MICROWAVE FREQUENCY| –
SOLID STATE RELAY| YES
EOL RESISTANCE| YES
CREEP ZONE DEVICE| YES
CASE TAMPER| YES
BACK TAMPER| NO
ANTI- MASKING| –
PULSE COUNTER| YES
RFI PROTECTION| 30 V/m
HEAT COMPENSATION| YES
FULLY DIGITAL| YES
SWIVEL OPTION| YES
POWER SUPPLY| 9-15 VDC / 25 mA
COVER MATERIAL| ABS
PET IMMUNITY| YES
OPERATING TEMPERATURE| -10°C to +40°C UL/ULC tested: 0°C to 49°C
HUMIDITY| 93% RH
DIMENSIONS| 114 x 63 x 40 mm

Johnson-Controls-LC-200S-IR-Detector-01 \(11\)

LC-200S complies with requirements EN 50131-2-2 Grade 2, EN 50131-2-2 Class II

  • Installation must be carried out by trained personnel according to professional standards.
  • The manufacturer accepts no responsibility if the product is tampered with by unauthorized persons.
  • The alarm system should be checked for proper operation at least once a month. However, a reliable electronic alarm system does not prevent intrusion, robbery, fire or
    anything else but merely decreases the risk of such situations occurring.

FCC Warning

NOTE

  • This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
    • Reorient or relocate the receiving antenna
    • Increase the separation between the equipment and receiver
    • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected
    • Consult the dealer or an experienced radio/TV technician for help.
  • Warning! Changes or modifications to this equipment not expressly approved by the party responsible for compliance (Tyco Safety Products Canada Ltd.) could void the user’s authority to operate the equipment.

This device complies with part 15 of the FCC rules. Operations are subject to the following two conditions:

  1. This device may not cause harmful interference and
  2. This device must accept any interference received, including interference that may cause undesired operation.

This Class B digital apparatus complies with Canadian ICES-003.
© 2022 Johnson Controls. All rights reserved.
JOHNSON CONTROLS is a registered trademark. Unauthorized use is strictly prohibited.

Read User Manual Online (PDF format)