niko 25490 300 Swiss Garde Mini Wall Instruction Manual

June 16, 2024
niko

niko 25490 300 Swiss Garde Mini Wall

Product Information

Specifications

  • Edition: 03-2023
  • Art.-Nr.: 25490, 25491
  • Supply Voltage: 230 V AC
  • Relay Switching Power: max. 1000 VA cos ϕ = 0,5
  • Detection Angle: 1.5 m – 10 m
  • Detection Range: 2 m – 10 m
  • Lux Level Control: 1.5 – 5
  • Timer Control: 450 s – 23 min
  • IP Rating: IP23
  • Temperature Range: -10°C to +32°C
  • Installation Height: >1m

Product Usage Instructions

Installation Instructions

  • Before installation, check that the electric cables are not live. Installation may only be performed by qualified electricians and by national regulations.

Safety Information

  • Ensure that the electric cables are not live before installation. Only qualified electricians should perform the installation, following national regulations.

Wiring

  • The electrical circuit must be protected by a circuit breaker.
  • The external push-button switches the line conductor to the R terminal.
  • Use push-buttons without a glow lamp and keep wires short.
  • Line conductor: L
  • Neutral conductor: N
  • Relay switching output: L’
  • External push-button (optional): R

External Push-button

  • The external push button is optional.
  • The light can be switched on manually.
  • It cannot be switched off manually.

Display

  • The following statuses are indicated by the LED. Parameter changes can be made by app or the P-IR remote control (accessory).
  • When a parameter change is confirmed, the detector briefly switches off the relay output.
Status LED Indication
Start-up Duration approx. 1 min, short flashes
Parameter change 3 x short flashes
Movement detection 1 x long flash

Troubleshooting

If the current-using equipment does not switch, ensure that the switching output is not switching too frequently.

FAQ

Q: Can I install the Swiss Garde 300 Mini-Wall myself?

  • A: No, installation should only be performed by qualified electricians.

Q: Can I switch off the light manually using the external push button?

  • A: No, the light can only be switched on manually using the external push button.

Q: How do I make parameter changes to the detector?

  • A: Parameter changes can be made using the app or the P-IR remote control (accessory).

INSTALLATION INSTRUCTIONS

Product Description

  • The device detects the movements of persons by means of a passive infrared (PIR) sensor. It reacts most sensitively to movements which are tangential to the monitored area (1).
  • Movements directly towards the detector result in a reduced sensitivity of approx. -50% (1). The detector does not switch until the brightness drops below the set value (twilight threshold).
  • The switching duration is extended as long as movements of persons (entire area 1) are detected. Products which are indicated as accessories are not included in the scope of delivery.

Application

  • The detector is suitable for indoor use for lighting control.

Please observe the following during installation:

  • Install only on stable walls.
  • Mask moving objects in the monitored area by taping over the lens.
  • Do not position any luminaires below or less than 1 m adjacent to the detector (2a).
  • Do not install in direct cold (2b) or warm air flows (2c).

Safety information

  • Before installation, check that the electric cables are not live.
  • Installation may only be performed by qualified electricians and under national regulations.

Installation

  • The detector is intended for wall installation, ideally at a height of 1 to 2.5 m.
  • The diameter (Ø) of the monitored area depends on the installation height (1).

Installation details:

  • Straightforward fixing with spring clips (4).
  • Configure the device as described under item 7.

Wiring

The electrical circuit must be protected by a circuit breaker. The external push-button switches the line conductor to the R terminal. Use push-buttons without a glow lamp and keep wires short.

Line conductor L
Neutral conductor N
Relay switching output L’
External push-button (optional) R

Connection of loads

  • High inrush currents shorten the service life of the relay integrated into the detector. Please observe the technical specifications provided by the manufacturer of the lamps and lighting equipment to avoid overloading the relay (3a–b).
  • To keep circuits to a manageable size, we recommend connecting no more than 5 detectors in parallel.
  • In case of higher-than-normal switching cycle frequencies or loads, we recommend the connection of the load via an external relay/circuit breaker.
  • Where electronic ballasts are used, we recommend that the number be limited to 20 per output.

Configuration

  • The parameters are set by the app or the P-IR remote control (accessory). For further details, please consult the operating instructions for the remote control.
  • TIME: TIME is used to set the delay after the last movement. If the relay output is wired to an automatic light, set TIME to impulse mode ( ).
  • Twilight threshold: LUX allows continuous setting of the trigger threshold of the twilight sensor between day mode and night mode.
  • Detection range: SENS is used to set the detection range. This setting allows sensitivity to be adjusted if the movement detector is oversensitive.

External push-button

  • The external push button is optional. The light can be switched on manually. It cannot be switched off manually.

Display

  • The following statuses are indicated by the LED. Parameter changes can be made by app or the P-IR remote control (accessory). When a parameter change is confirmed, the detector briefly switches off the relay output.niko-25490-300-Swiss-Garde-Mini-Wall-FIG-12

Troubleshooting

  • Current-using equipment does not switch: Switching output switches too frequently:
  • Twilight threshold too high
  • Check luminaire/overcurrent protection
  • Reduce detection range/check detection area for the source of the fault
  • Tape over lens / Check distance from luminaires
  • Twilight threshold too low

Technical data

Supply voltage 230 V ~ 50 Hz
Circuit breaker maximum MCB rating 10 A*
Relay switching power max. 2300W, 10 A resistive

max. 1150VA, 5 A inductive

LED 350 W

Detection angle| 180°
Detection range| approx. 8 m radius for 2.5 m height
Lux level control| 10–2000 lx
Timer control| Impulse, approx. 10 s to 20 min
IP rating| IP44
Temperature range| -20 °C to +55 °C
Installation height| 1–2.5 m
Dimensions| Ø 37×32 mm (visible dimensions)

The MCB rating is limited by national installation rules.

Warnings regarding installation

  • The installation of products that will permanently be part of the electrical installation and which include dangerous voltages should be carried out by a qualified installer and under the applicable regulations.
  • This user manual must be presented to the user. It should be included in the electrical installation file and it should be passed on to any new owners.
  • Additional copies are available on the Niko website or via Niko customer services

CE marking

  • This product complies with all of the relevant European guidelines and regulations. For radio equipment, Niko LLC declares that the radio equipment in this manual conforms with the 2014/53/EU directive.
  • The full text of the EU Declaration of conformity is available at www.niko.eu under the product reference, if applicable.

Environment

  • This product and/or the batteries provided cannot be disposed of in non-recyclable waste.
  • Take your discarded product to a recognized collection point. Just like producers and importers, you too play an important role in the promotion of sorting, recycling, and reuse of discarded electrical and electronic equipment.
  • To finance the rubbish collection and waste treatment, the government levies recycling charges in certain cases (included in the price of this product).

Support & contact

  • nv Niko sa
  • Industriepark West 40
  • 9100 Sint-Niklaas, Belgium
  • www.niko.eu
  • +32 3 778 90 80support@niko.eu
  • Niko prepares its manuals with the greatest care and strives to make them as complete, correct, and up-to-date as possible.
  • Nevertheless, some deficiencies may subsist. Niko cannot be held responsible for this, other than within the legal limits.
  • Please inform us of any deficiencies in the manuals by contacting Niko customer services at support@niko.eu.

Documents / Resources

| niko 25490 300 Swiss Garde Mini Wall [pdf] Instruction Manual
25490 300 Swiss Garde Mini Wall, 25490, 300 Swiss Garde Mini Wall, Swiss Garde Mini Wall, Garde Mini Wall, Mini Wall, Wall
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>