GENERAL LIFE SENNA 270S Digital Room Thermostat User Manual

June 16, 2024
GENERAL LIFE

GENERAL LIFE SENNA 270S Digital Room Thermostat

DIGITAL ROOM THERMOSTAT SENNA 270S USER MANUAL!!

generallife.com.tr

GENERAL SPECIFICATIONS

  • SENNA 270S is a wired room thermostat.
  • Different Mode Options (Comfort Mode and Economy Mode)
  • Precise Temperature Measurement
  • ON/OFF Control
  • Heating Calibration
  • Wired Connection
  • Heating/Cooling Modes
  • TPI Algorithm

SENNA 270S AND EQUIPMENT SENNA 270S

  • Room Thermostat
  • Alkaline Battery
  • Dowels and Screws
  • AAA AAA

TECHNICAL DATA

  • Dimensions: 85mm / 125mm / 19mm

  • Operating Current: 3V DC (2 x AAA alkaline battery)

  • Relay NO Switching Current: 2A/30VDC (Resistive load)

  • Temperature Measurement Accuracy: 0.5A/125VAC (Resistive
    load)

  • Operating Temperature Range: 0.1oC

  • Battery Life:

  • Operating Temperature:

  • Storage Temperature:

ROOM THERMOSTAT BUTTON FUNCTIONS

  1. ON/OFF and Setting Button
  2. Economy Mode
  3. Comfort Mode
  4. Heating/Cooling Modes (Press and hold for 5 seconds.)
  5. Temperature Adjustment (Increasing)
  6. Temperature Adjustment (Decreasing)

BATTERY PLACEMENT

Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off.

ROOM THERMOSTAT WIRING DIAGRAM

HEATING/COOLING UNIT

Warning! Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons.

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Temperature sensors that are used in Room Thermostats are highly sensitive. You may need to calibrate your Room Thermostat if you would like to get the same temperature values with other thermometers in your living space.

  1. While your device is turned off, press and hold the On/Off button for 3 seconds.
  2. Press the On/Off button until the menu appears.
  3. In order to see the desired temperature, set the temperature difference by pressing the Temperature Adjustment Buttons. This value can be arranged between -8oC and +8oC.
  4. To save the settings and exit, press the On/Off button until the device turns off.

Note: Recommended temperature calibration is 0.0oC.

FACTORY SETTINGS RESET

You can reset your Room Thermostat to its default factory settings. This operation resets the mode temperature values, calibration setting, and heating/cooling modes to the factory setting.

  1. While your device is turned off, press and hold the On/Off button for 3 seconds.
  2. Press the On/Off button until the menu appears.
  3. While in the menu, select the option by using + or – buttons and press the On/Off button.
  4. Your device will be turned off and reset to factory settings.

MODE SETTINGS

There are 2 modes in the Room Thermostat. These are Comfort Mode and Economy Mode. Modes work according to the pre-set temperature values adjusted by the user.

  1. Press and hold the comfort mode button for 3 seconds.
  2. Change the temperature value by pressing + or – buttons.
  3. Press the comfort mode button once to save the changes you have made.

FAQ (Frequently Asked Questions)

  • Q: How do I change the mode on the Room Thermostat?
  • A: To change the mode on the Room Thermostat, press and hold the comfort mode button for 3 seconds. Then, use the + or – buttons to adjust the temperature value. Finally, press the comfort mode button once to save the changes.
  • Q: How do I reset my Room Thermostat to factory settings?
  • A: To reset your Room Thermostat to factory settings, ensure that your device is turned off. Press and hold the On/Off button for 3 seconds. Then, press the On/Off button until the menu appears. Select the reset option using the + or – buttons and press the On/Off button to confirm. Your device will be turned off and reset to factory settings.
  • Q: How do I calibrate the temperature on my Room Thermostat?
  • A: To calibrate the temperature on your Room Thermostat, ensure that your device is turned off. Press and hold the On/Off button for 3 seconds. Then, press the On/Off button until the menu appears. Adjust the temperature difference using the Temperature Adjustment Buttons. The value can be set between -8oC and +8oC. Finally, press the On/Off button to save the settings and exit.

GENERAL SPECIFICATIONS

SENNA 270S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economic heating/cooling.Different Mode Options (Comfort Mode and Economy Mode)

  • Precise Temperature Measurement
  • Heating Calibration
  • Heating/Cooling Modes
  • ON/OFF Control
  • Wired Connection
  • TPI Algorithm

SENNA 270S AND EQUIPMENT

TECHNICAL DATA

Dimensions 85mm / 125mm / 19mm
Operating Current 3V DC (2 x AAA alkaline battery)
Relay NO Switching Current 2A/30VDC (Resistive load)

0.5A/125VAC (Resistive load)

Temperature Measurement

Accuracy

| 0.1oC
Operating Temperature Range| (5oC) – (30oC)
Battery Life| 1 Year (2 x AAA)
Operating Temperature| (-10oC) – (+50oC)
Storage Temperature| (-20oC) – (+60oC)

ROOM THERMOSTAT  Buttons Functions

1 ON/OFF and Setting Button
2 Economy Mode
3 Comfort Mode
4 Heating/Cooling Modes (Press and hold for 5 seconds.)
5 Temperature Adjustment (Increasing)
6 Temperature Adjustment (Decreasing)

Screen Indicators

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-4

ROOM THERMOSTAT PLACEMENT

Room Thermostat needs to be placed in the room which is used most frequently. For instance; the living room or lounge. Placing the Room Thermostat in a spot that has air circulation like the entrance of a room or the side of a window should be avoided. Also anywhere close to heating/cooling units such as radiator, stove, and spots which get direct sun lights would not be suitable. Room Thermostat needs to be located above the floor 150 cm in height. Few trials may be made to find the most convenient spot

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-5

BATTERY PLACEMENT

Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off.

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-6

As shown in the picture above, press the screwdriver forward from the space shown, bend the tabs, and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back

Low Battery Warning : When the “ ” icon appears on the screen, it means “low battery warning”. It is recommended to replace the batteries when this warning appears. Warning: When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that may occur would be out of warranty. Please throw your dead batteries into the waste bin for batteries

ROOM THERMOSTAT WIRING DIAGRAM

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-8

Warning

Operations within the heating/cooling unit or the electrical installation must be carried out by professionally qualified persons.

ROOM THERMOSTAT TEMPERATURE CALIBRATION

Temperature sensors that are used in Room Thermostats are highly sensitive. You may need to calibrate your Room Thermostat if you would like to get the same temperature values as other thermometers in your living space.

  • While your device is turned off, press and hold the “On/Off”button for 3 seconds.
  • Press the “On/Off” button until the “ ” menu appears. In order to see the desired temperature, set the temperature difference by pressing the “Temperature Adjustment Buttons”. This value can be arranged between “-8oC” and “+8oC”.
  • To save the settings and exit, press the “On/Off” button until the device turns off.
    Note : Recommended temperature calibration is “0.0oC

FACTORY SETTINGS RESET

You can reset your Room Thermostat to its default factory settings.  This operation resets the mode temperature values, calibration setting, and heating/cooling modes to the factory setting. To reset your Room Thermostat to factory setting:

  • While your device is turned off, press and hold the “On/Off”button for 3 seconds.
  • Press the “On/Off” button until “ ” menu appears.
  • While in the “ ” menu, select the “ ” option by using “+” or “-” buttons and press the “On/Off” button.
  • Your device will be turned off and reset to factory settings.

MODE SETTINGS

There are 2 modes in the Room Thermostat. These are Comfort Mode \ “ ” and Economy Mode “ ”. Modes work according to the pre-set temperature values adjusted by user. In order to change the comfort mode temperature value;

  • Press and hold the comfort mode button for 3 seconds.
  • Change the temperature value by pressing the “+” or “-“ buttons.
  • Press the comfort mode button once to save the changes you have made or wait 10 seconds In order to change the economy mode temperature value;
  • Press and hold the economy mode button for 3 seconds.
  • Change the temperature value by pressing the “+” or “-” buttons.
  • Press the economy mode button once to save the changes you have made or wait 10 seconds. You can use the “+” and “-” buttons to use the Room Thermostat manually.

TPI ROOM THERMOSTAT WORKING LOGIC

Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI technology predict when the temperature of your home will rise above or below the set temperature and turn the heating / cooling unit on and off accordingly. This ensures that your home stays at the temperature you set without maximum deviations up and down

  • What is TPI?
    TPI technology is designed to ensure that you get the best possible energy efficiency from your heating/cooling system. It measures and applies the best possible timings to deliver and maintain your home at the set temperature level.

  • How does TPI work?
    Thanks to the advanced artificial intelligence technology found in the software, it adapts to the temperature change of the environment in which it is located. By creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how to maintain this temperature. In this way, it provides minimum energy consumption by calculating how long your heating/cooling unit should work for.

  • What is the difference?
    In non-TPI room thermostats, the heating/cooling unit works and stops continuously until it exceeds the set temperature value. If the set temperature drops below a certain amount, the heating/cooling unit will work again. This creates greater temperature fluctuations and less energy control. TPI Room Thermostats, on the other hand, provide higher savings and comfort compared to On/Off room thermostats with the advantages it has.

Heating Mode

Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is maintained. Thus, it ensures that the room temperature remains within a certain range.

TPI ROOM THERMOSTAT HEATING MODE WORKING GRAPHIC

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-15

Cooling Mode

Your room thermostat takes the average room temperature of the last 40 seconds as a basis. With the TPI algorithm in the product by creating a general temperature map of your home, it learns how long it takes to reach the desired room temperature and how this temperature is
maintained. Thus, it ensures that the room temperature remains within a certain range.

TPI ROOM THERMOSTAT COOLING MODE WORKING GRAPHIC

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-16

WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT

  • If the placement of the TPI Room Thermostats is changed, the learning process will restart. The learning process should be considered as 7 days.
  • If the TPI Room Thermostats are de-energized (battery replacement), the learning process will restart. The learning process should be considered as 7 days.

FREQUENTLY ASKED QUESTIONS

  • Is my Room Thermostat compatible with my heating/cooling unit?
    If your heating/cooling unit has on-off connections, your Room Thermostat is compatible. You can find information about your heating/cooling unit from your heating/cooling unit operating manual or from your heating / cooling unit service.

  • How will I connect my Room Thermostat to the heating/cooling unit?
    We recommend that the connection between your Room Thermostat and the Heating/Cooling unit should be made by professionally qualified persons. 2×0.75 mm cable is sufficient for the Room Thermostat – heating/cooling unit connection. Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of the heating/cooling unit. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Wall Hanger of the Room Thermostat as shown in the “ROOM THERMOSTAT WIRING DIAGRAM” section. The direction of the cable ends does not matter.

DECLARATION OF CONFORMITY

The Head Office and production site is located on Fatih Mah. 1188 Sk. No:13/A Sarnıç – Gaziemir – İZMİR – TÜRKİYE confirms and declares that the product marked with CE and its specifications below is
covered by the provisions of the mentioned directive.

  • Brand: GENERAL Life
  • Product Name: SENNA 270S
  • Product Type:: Digital Room Thermostat
  • Compatible Directives: Electromagnetic Compatibility Regulation 2014/30/EU (EN 61000-6-1:2019, EN 61000-6-3: 2021) Low Voltage Directive 2014/35/EU (EN 60730-2-9)
  • Additional Information: The mentioned product can be used with heating/cooling units with on / off output and compliance with the directives only covers the product. ISIPARK is not responsible for the entire system’s compliance with the directives. This statement is not valid if changes are made to the product without our approval

WARRANTY CONDITIONS

  1. The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years.
  2. Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
  3. The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company. In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
  4.  The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
  5.  In case of malfunctioning of the devices and apparatus whose warranty period continues, it is tested in our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
  6. In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
  7. In the event that the faults of the devices and apparatus whose warranty period continues are determined as caused by the customer, all expenses would be belong to the customer.
  8. Customers should be aware of damages (if there is any) of the product and warn manufacturer from the day the warranty duration starts.If customer do not warn the manufacturer with knowledge of the damage, the customer loses the rights of article 6.
  9. Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
  10. Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.
  11. Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
  12. Battery leakage and errors due to rust, oxidation, and liquid contact by working in acidic/humid environments are not covered by the warranty.
  13. When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
  14. Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
  15. Damages caused by mains voltage / faulty electrical installation are not covered by the warranty
  16. Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake, etc.
  17. All of the devices and apparatuses, including all their parts, are under the warranty of our company.
  18. In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repairment period is added to the warranty period. The repair period of the product cannot exceed 20 working days. This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer, or manufacturer of the product. Consumers can report the problem by; phone, fax, e-mail, registered and reply paid letter or a similar way. However, in the case of a conflict, the responsibility of proving belongs to the customer. If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed.
  19.  Although the consumer uses his/her repair rights,
  20. If the product breaks down 4 times in a year or 6 times in warranty duration these problems affect the main purpose of the product. (starting from delivery time during warranty.) –
  21. Exceeding the maximum time required for repair,
  22. In the event that the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the seller, dealer, agency, representative, importer or manufacturer, a refund or a price discount at the rate of defect can be requested..
  23. The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
  24. The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.

WARRANTY CERTIFICATE

  • Manufacturer
  • Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç
  •  Tel: +90 (232) 457 99 50 Fax: +90 (232) 457 91 22
  • E-Mail: generallife@generallife.com.tr Authorised Signatory:
  • Company Stamp:

Product

  • Type: Digital Room Thermostat Brand: GENERAL Life
  • Model: SENNA 270S
  • Guarantee Period: 5 Years
  • Max. Time to Repair: 20 Days Banderole and Serial Number:

GENERAL-LIFE-SENNA-270S-Digital-Room-Thermostat-FIG-17

Isıpark reserves the right to change product specifications and user manuals. *For all changes, you may visit generallife.com.tr

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals