infineon TLE5x09A16-D Evaluation Kit Instruction Manual

June 16, 2024
infineon

TLE5x09A16(D) Evaluation Kit
Analog AMR/GMR Angle Sensor Evaluation Kit”
Instruction Manual

About this document

Scope and purpose
This document describes the Evaluation Kit for the TLE5x09A16(D) angle sensor. The purpose of this manual is to describe the software installation process and how to use the TLE5x09A16(D) angle sensor Evaluation Kit.
Intended audience
This document is intended for anyone who wants to use the TLE5x09A16(D) Evaluation Kit

General description

This kit is based on XMC™ 4700 platform. The kit is equipped with the TLE5x09A16(D) dual die angle sensor and a FTDI chip that implements a high baud rate communication.
The EvalKit consists of:

  • Dual Die Angle Sensors Evaluation Board
  • Rotation knob (3D printed) with magnet (MTS SD-6×2.5-NI-N35SH)

The EvalKit does not contain:

  • micro USB cable

infineon TLE5x09A16 D Evaluation Kit - Figure 1The Evaluation Kit includes a GUI software application that can be downloaded from the Evaluation Kit product page

Installation

This is the installer entry point.infineon TLE5x09A16 D Evaluation Kit -
Installation

  1. Click Next to go forward with the process

  2. Please read the license agreement
    a. Check the “I accept the terms in the License Agreement” checkbox
    b. The “Next” button activates only after agreeing with the terms

  3. Directory for the software installation
    a. You may select the installation folder – recommended is to leave the default installation path
    b. You may select if a desktop icon is generated or not
    c. The hardware device may only operate on a computer that has the FTDI driver installed
    d. The Software GUI is built in .NET environment 4.5. A check is being done for compatibility and you may choose to install (if not already installed) the .NET framework 4.7 (web installer – requires connection to internet)

  4. Confirm the installation process

  5. Beginning of the installation process
    a. Windows UAC (user access control) will prompt for access confirmation
    b. Depending on the security settings, you may need administration rights on the installation machine
    c. Wait for the installation process to finish

  6. Beginning ot the FTDI driver installation process

  7. Device driver installation Wizard
    a. This wizard helps you install the software drivers that some computers devices need in order to work
    b. Click next to continue

  8. Please read the license agreement and check the “I accept this agreement” checkbox. The “Next” button activates only after agreeing with the terms

  9. Finalize the installation by clicking Finish
    a. Check the message provided by the installer. In case of errors, the Software will not be available for running

Evaluation Kit for Angle Sensors

3.1 Connection to PC and starting the application
Connect the hardware to PC using a USB to Micro-USB cable
Start the application (via shortcut on desktop or Start → All Programs → Infineon Technologies → Dual Angle Sensor Evalkit)

  1. This GUI component will show any connected devices. You may select the device and open a connection / flash the device.
    Note: Press the ´Connect´Button to go on. There are three buttons available: Connect, disconnect, refresh

  2. You may select the sensor type via the combo-box and start/stop acquisition.

  3. Sensor panel – will be displayed after valid sensor is being selected by the user.infineon TLE5x09A16 D Evaluation Kit - Angle Sensors

3.2 Connecting to the device
While connecting to the device, the animated picture with rotating gears will appear.
The software will check the firmware version and flash if it needs to be updated.
The picture will disappear when the process is omplete and the device is ready.infineon TLE5x09A16 D Evaluation Kit - Angle Sensors
2 3.3 TLE5x09A16(D) sensor panel
After selecting the sensor from the drop down list, the sensor panel will appear.
You can now start the data acquisition. All controls (Settings, Calibration Panel, Save, Clear) become available only if data acquisition is stopped.infineon TLE5x09A16 D Evaluation Kit - sensor
panel 3.4 Calibration panel
The raw signals of the analog angle sensor TLE5x09A16(D) have to be calibrated to achieve high angle accuracy.
A calibration of amplitude, offset and non-orthogonality has to be done when the sensor is used the first time (end-of-line calibration).
When the panel opens the final parameters used for angle calibration are read from the microcontroller.
In this panel the user can start the sensor calibration procedure. Every start will reset the existing calibration parameters stored on the microcontroller.
Below the circle quadrants, instruction messages are displayed.

Press Start to beginn.infineon TLE5x09A16 D Evaluation Kit - Evaluation
KitRotate the knob slowly counter clockwise.infineon TLE5x09A16 D Evaluation Kit - Evaluation Kit
2Rotate the knob slowly clockwise.infineon TLE5x09A16 D Evaluation Kit - Evaluation Kit
3Calibration finished.infineon
TLE5x09A16 D Evaluation Kit - Evaluation Kit 4

After the calibration process is complete, the user can read and save the calibration parameters stored on the microcontroller.
In the panel are displayed only the final parameters used for angle calibration. By clicking “Open Last File”, the user can access the full parameters list stored on a csv file at every “Read and Save”.
The example in Figure 4 shows the calibration parameters amplitude, offset and non-orthogonality of TLE5309(D) sensor. The X value corresponds to the cosine output while the Y value corresponds to the sine.
The GMR sensor is placed on the top and the AMR sensor on the bottom of the package. The bottom sensor is in flipped configuration compared to the top sensor in TLE5x09A16(D) dual die variants.infineon TLE5x09A16 D Evaluation
Kit - Evaluation Kit 5Files are saved in the computer: “C:\Users\\AppData\Local\InfineonDualAnalogAngleTemp” The calibration procedure is done on the microcontroller with the “Library for One Time Calibration & Compensation”.infineon TLE5x09A16 D Evaluation Kit -
Evaluation Kit for Angle Sensors 3.5 TLE5x09A16(D) sensor panel
The TLE5x09A16(D) eval kit displays real-time angle values.
After the sensor is fully calibrated, the calibrated angle value will be displayed.
The user can click and pin a cursor in the signal chart. If the checkbox “Enable Cursor Snap” is checked, the cursor will point to the nearest signal value. The cursor value is displayed in the right corner box.
The user can also zoom into the chart by using mouse scroll.infineon
TLE5x09A16 D Evaluation Kit - 3 Evaluation Kit for Angle
Sensors 3.6 Sensor config panel
This panel can be accessed while data acquisition is stopped at Settings → Sensor Config.
The user can select a predefined acquisition rate for the sensor data read. Lowering the rate will reduce the required processing power (on the microcontroller and computer).infineon TLE5x09A16 D Evaluation Kit - Sensor
config panel 3.7 TLE5x09A16(D) saved sensor acquired data
All sensor acquired data can be saved in a csv file, by pressing “Save” button from the sensor panel.infineon TLE5x09A16 D Evaluation Kit - Sensor config
panel 2

Revision history

Revision Date Changes
Rev. 1.0 2020-06-17 • Initial creation

Trademarks
All referenced product or service names and trademarks are the property of their respective owners.

Edition 2020-06-12
Published by
Infineon Technologies AG
81726 Munich, Germany
© 2020 Infineon Technologies AG All Rights Reserved.
Do you have a question about any aspect of this document?
Email:erratum@infineon.com
Document reference
IFX-lpa1591258043489

IMPORTANT NOTICE

The information given in this document shall in no event be regarded as a guarantee of conditions or characteristics (“Beschaffenheitsgarantie”) .
With respect to any examples, hints or any typical values stated herein and/or any information regarding the application of the product, Infineon Technologies hereby disclaims any and all warranties and liabilities of any kind, including without limitation warranties of non-infringement of intellectual property rights of any third party.
In addition, any information given in this document is subject to customer’s compliance with its obligations stated in this document and any applicable legal requirements, norms and standards concerning customer’s products and any use of the product of Infineon Technologies in customer’s applications.
The data contained in this document is exclusively intended for technically trained staff. It is the responsibility of customer’s technical departments to evaluate the suitability of the product for the intended application and the completeness of the product information given in this document with respect to such application.

WARNINGS
Due to technical requirements products may contain dangerous substances. For information on the types in question please contact your nearest Infineon Technologies office.
Except as otherwise explicitly approved by Infineon Technologies in a written document signed by authorized representatives of Infineon Technologies, Infineon Technologies’ products may not be used in any applications where a failure of the product or any  consequences of the use thereof can reasonably be expected to result in personal injury

Rev. 1.0
Evaluation Kit

Documents / Resources

| infineon TLE5x09A16-D Evaluation Kit [pdf] Instruction Manual
TLE5x09A16-D, TLE5x09A16-D Evaluation Kit, Evaluation Kit, Kit
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals