REAL-EL RS-8 Protect Power Strip Surge Protector User Manual

June 16, 2024
REAL-EL

REAL-EL RS-8 Protect Power Strip Surge Protector

Technical Specifications

  • Input voltage (max): ~250 V
  • Operation frequency: 50 Hz
  • Total power of connected load not more than: kW
  • Maximum energy absorption of pulse interference: J
  • Maximum load current: A
  • Input plug type: CEE 7/7
  • Output socket type: &(( PPt
  • Cable length: m
  • Dimensions: mm

Product Information
Congratulations on purchasing the REAL-EL surge protector! The RS-8 Protect surge protector is designed for connection of electrical appliances to the electrical network and their protection from a pulse overvoltage. It features a cable made of pure copper without the use of alloys, sockets with grounding and protective shutters, and a built-in surge protection device.

Safety Precautions

  • Do not exceed the maximum input voltage specified.
  • Do not use the surge protector if it is damaged or shows signs of wear.
  • Do not attempt to repair the surge protector yourself.
  • Connect the surge protector to a grounded electrical network.

Product Usage Instructions

Connection

  1. Plug the surge protector into a grounded electrical outlet.
  2. Connect your electrical appliances to the surge protector’s sockets.
  3. Make sure the total power of the connected load does not exceed the specified limit.

Operation

  1. Make sure the surge protector’s power switch is in the “Off” position.
  2. Turn on the surge protector by flipping the power switch to the “On” position.

Disconnection

  1. Turn off and unplug all connected electrical appliances.
  2. Turn off the surge protector by flipping the power switch to the “Off” position.
  3. Unplug the surge protector from the electrical outlet.

FAQ

Q: Can I use the surge protector with appliances that have a higher power rating?
A: No, you should not exceed the maximum power rating specified for the surge protector. Using appliances with a higher power rating may cause damage to the surge protector or the
appliances.

Q: Can I repair the surge protector myself if it gets damaged?
A: No, you should not attempt to repair the surge protector yourself. Opening or repairing the surge protector by yourself may result in electric shock or further damage to the unit. Please contact technical support or a qualified technician for assistance.

Q: How long is the cable of the surge protector?
A: The cable length of the surge protector is m.

Q: Where can I find technical support for the surge protector?
A: You can find technical support for the surge protector at www.real- el.com.

Congratulations on purchasing the TM REAL-EL surge protector!
Please read this User’s Manual before using the unit and retain this User’s
Manual in a safe place for future reference.

COPYRIGHT
© 2022. ENEL GROUP OU.
This Manual and information contained in it are copyrighted.
All rights reserved.

TRADEMARKS
All trademarks are the property of their legal holders.

NOTICE OF RESPONSIBILITY RESTRICTION
Despite the exerted efforts to make this Manual more exact, some discrepancies may occur. The information in this Manual is given on “as is” terms.
The author and the publisher do not bear any liability to a person or an organization for loss or damage which has arisen from the information contained in this Manual.

PACKAGE CONTENTS

  • Power strip surge protector- 1 pc
  • Warranty card/User’s manual – 1 pc

APPLICATION
The RS-8 Protect surge protector is designed for connection of electrical appliances to the electrical network and their protection from an pulse overvoltage.

FEATURES

  • Cable made of pure copper without the use of alloys
  • Double-pole switch
  • Sockets with grounding and protective shutters
  • Impact-resistant body made of fire-resistant plastic

SAFETY PRECAUTIONS

  • Do not connect the surge protector to the electrical network with overrating voltage.
  • Do not connect the load to the surge protector with the total power, which exceeds the power indicated in specifications of this device.
  • Do not use the surge protector in places with possible ingress of liquid,moisture, dust and high temperature exposure.
  • Do not open and do not make any repairs by yourself.
  • Connect the surge protector to the grounded electrical network.

CONNECTION

  • Connect equipment to surge protector sockets.
  • Connect the surge protector to 230 V electrical network, turn on the master switch.

OPERATION

  • Do not overload the surge protector by connection of several powerful devices.
  • On operation of the automatic fuse due to the overload, turn on the surge protector once more in 5-10 minutes after reduction of the total connected load to a permissible limit. For this purpose, turn the power switch.
  • If high-voltage impulses or intolerable high voltage occurs at the surge protector input, the built-in emergency protection can disconnect the surge protector completely. The surge protector operation with the partial or complete resource loss of the surge protector components is intolerable.

TECHNICAL SPECIFICATIONS

Parameters Value and measurement unit
Input voltage (max) ~250 V
Operation frequency 50 Hz
Total power of connected load not more than 3,68 kW
Maximum energy absorption of pulse interference 350 J
Maximum load current 16 A
Input plug type CEE 7/7
Output socket type 8 x CEE 7/3
Cable cross-section 3 x 1,5 mm2
Cable length 1,8; 3; 5 m
Dimensions 100 x 40 x 210 mm

Notes:

  • Technical specifications given in this table are supplemental information and cannot give occasion to claims.
  • Technical specifications and package contents are subject to change without notice due to improvement of TM REAL-EL production.

Model: RS-8 Protect
Manufacturer: ENEL GROUP OU, Katusepapi tn 6, Lasnamäe district, Tallinn city,Harju county, 11412, Estonia. Made in China.
® Registered Trademark of ENEL GROUP OU. Estonia.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals