Traulsen UPT328-L 32 Inch 1 Left Hinged Door Refrigerated Sandwich Prep Table Owner’s Manual
- June 4, 2024
- Traulsen
Table of Contents
Traulsen UPT328-L 32 Inch 1 Left Hinged Door Refrigerated Sandwich Prep Table
THE SERIAL TAG
The serial tag is a permanently affixed label on which is recorded vital electrical and refrigeration data about your Traulsen product, as well as the model and serial number. This tag is located in the right interior compartment on all standard models.
a – READING THE SERIAL TAG:
- Serial = The permanent ID# of your Traulsen unit
- Model = The model # of your Traulsen unit
- Volts = Voltage
- Hz = Cycle
- PH = Phase
- Total Current = Maximum amp draw
- Minimum Circuit = Minimum circuit ampacity
- Lights = Light wattage
- Heaters = Heater amperage (Hot Food units only)
- Refrigerant = Refrigerant type used and refrigerant charge
- Design Pressure = High & low side operating pressures
- Agency Labels = Designates agency listings
RECEIPT INSPECTION
All Traulsen products are factory tested for performance and are free from defects when shipped. The utmost care has been taken in crating this product to protect against damage in transit.
You should carefully inspect your unit for damage during delivery. If damage is detected, you should save all the crating materials and make note on the carrier’s Bill Of Lading describing the damage. A freight claim should be filed immediately. If damage is subsequently noted during or immediately after installation, contact our customer care team to file a freight claim. There is a fifteen (15) day limit to file freight damage with the carrier. Under no condition may a damaged unit be returned to Traulsen without first obtaining written permission (return authorization). You may contact Hobart/Traulsen customer care at 800-333-7447 to request a return or file a claim.
INSTALLATION
a – LOCATION:
Select a proper location for your unit, away from extreme heat or cold.
Allow enough clearance between the unit and the side wall in order to make use
of the stay open feature at 1200 (self-closing feature operates up to 900 ).
The door(s) must be able to open a minimum of 900 in order to make use of the
maximum clear door width.
NOTE: Do not install the cabinet without legs, casters or front ventilated utility base.
b – PACKAGING:
All Traulsen units are shipped from the factory bolted to a sturdy wooden pallet and packaged in a durable cardboard container. The carton is attached to the wooden skid with the use of large staples. These should first be removed to avoid scratching the unit when lifting off the crate.
To remove the wooden pallet, first if at all possible, we suggest that the cabinet remain bolted to the pallet during all transportation to the point of final installation. The bolts can then be removed with a 5/8” socket wrench by tipping or otherwise raising the unit to allow access to them. Avoid laying the unit on its front, side or back for removal of the pallet.
NOTE: Traulsen does not recommend laying the unit down on its front, side or back. However, if you must please be certain to allow the unit to remain in an upright position afterwards for 24 hours before plugging it in so that the compressor oils and refrigerant may settle.
c – INSTALLING/ADJUSTING LEGS OR CASTERS:
6” High legs are supplied standard for all Traulsen compact undercounter and
prep table units. These are shipped from the factory inside a cardboard box
which is secured inside the cabinet. Casters in lieu of legs are supplied as
an optional accessory for all compact undercounter and prep table models.
The casters are “stem” type, and do not require the use of any bolts. When
ordered casters are shipped in a separate box.
WARNING: THE CABINET MUST BE BLOCKED AND STABLE BEFORE INSTALLING LEGS OR CASTERS.
Raise up and block the cabinet a minimum of 7” from the floor and thread the
legs into the threaded holes on the bottom of the cabinet’s.
Thread optional casters into the threaded holes on the bottom of the cabinet
in the same way. Casters with brakes should be installed at the front.
Level the cabinet using a level or pan of water in the bottom of the cabinet.
On units with legs, turn the adjustable feet in or out to level the cabinet
side-to-side and front-to-back. Units with casters should be placed on level
floors.
NOTE: Traulsen units are not designed to be moved while on legs. If the unit requires moving, a pallet jack or forklift should be used to prevent damage.
d – SHELF CLIPS FOR DOOR MODELS:
Shelves and shelf clips are shipped with the unit. For each shelf, insert four
(4) shelf clips into the pilaster slots at the same height. The shelf clips
have a small projection on top which holds the shelf position and prevents it
from slipping forwards. After installing shelf clips on pilasters, place
shelves on clips.
e – CORD & PLUG:
All UHT, ULT, UPT & UST models are supplied with a cord and plug attached. It is shipped coiled at the bottom of the cabinet, secured by a nylon strip. For your safety and protection, all units supplied with a cord and plug include a special three-prong grounding plug on the service cord. Select only a dedicated electrical outlet with grounding plug for power source.
NOTE: Do not under any circumstances, cut or remove the round grounding prong from the plug, or use an extension cord.
f – POWER SUPPLY:
The supply voltage should be checked prior to connection to be certain that proper voltage for the cabinet wiring is available (refer to the serial tag to determine correct unit voltage, see page 1). Make connections in accordance with local electrical codes. Use qualified electricians.
Use of a separate, dedicated circuit is required. Size wiring to handle
indicatedload and provide necessary over current protector in circuit (see
amperage requirements on the unit’s serial tag).
i – INSTALLING THE STAINLESS STEEL TOP-UHT
All 27”, 32, 48, and 60” wide compact undercounter models can be supplied with
an optional stainless steel top. This must be installed on-site, to do so
please follow the directions below.
-
Peel Off backing and install foam tape (provided) around entire perimeter of the top of the unit.
-
A flange is assembled underneath at the front of the counter top.
This flange has two screw holes. Screw the two 1/4-20×5/8” screws (provided through the holes in this front flange into the threaded holes in the front of the top edge of the unit. -
Using the five 10-16×1/2” screws provided, screw the bottom of the rear cover plate to the upper rear of the cabinet.
-
If the optional polyethylene cutting board top is provided, there are four threaded pins which screw into the four threaded holes in the work top. The four holes in the polyethylene cutting board top fit around the heads of the four pins.
OPERATION
a – PRESTART CHECKS:
The compressor must float freely before connecting to electrical power.
The compressor motor is provided with rubber vibration isolator mounts (no
springs). No bolts need to be loosened. Check all exposed refrigeration lines
to make sure they are not dented or kinked. Check for tubing shifts due to
shipping that would cause operating noise, wear, or leaks. Check that
condenser fan rotates freely
The refrigeration system should be checked for proper operation before product is stored in the cabinet.
b – TEMPERATURE CONTROL:
The temperature is set at the factory but local conditions may necessitate slight adjustment.
The temperature control shown in below is located on the front side of the
evaporator housing. To adjust, turn the adjustment screw with a screwdriver a
small amount at a time; turning clockwise lowers the temperature. An “OFF”
position is fully counterclockwise and interrupts power to the compressor and
condenser fan only, not the entire refrigerator.
ULT32 freezer model is equipped with a knob that has a number ranging from 0
to 9. Turning the knob clockwise lowers the temperature, turning the knob
counterclockwise raises the temperature. O is the “OFF” position. The
temperature range of adjustments is -5 to 5 F degrees.
c – DEFROST CONTROL:
Frozen food storage cabinets are equipped with a defrost timer that provides a
20 minute defrost cycle every 6 hours (four defrost cycles per day).
c – DEFROST CONTROL: (continued)
This control can be adjusted to set when the next defrost cycle will start. To adjust the defrost time control, use a coin on the outside slot in the rim of the timer and turn clockwise until the compressor turns off. Continue turning coin clockwise until the compressor restarts. The next defrost cycle will start in about 5 hours 40 minutes. On all models ULT27, ULT48 and ULT60, the defrost time control is located on the front side of the evaporator housing, behind the temperature control adjustment screw. On earlier models ULT48 and ULT60, the defrost time control was accessed through a small round opening on the outside rear of the unit.
ULT32 freezer model requires no adjustment. The defrost occurs every 4 hours. It is time initiated and temperature terminated with a time safety backup.
d – REFRIGERATING PRODUCT:
A thermometer is provided inside all UHT, ULT, UPT & UST models. Allow the
cabinet to reach normal operating temperature before loading.
UHT, ULT, UPT & UST Series will satisfactorily refrigerate an assorted load of
food items. Allow space between articles to permit free aircirculation. Do not
overload at any one time with warm food products and expect immediate results.
A certain amount of time is required to remove heat from items before
operating temperatures can be attained.
The system is designed for storage of refrigerated or frozen product.
Opening the door or drawer will increase the temperature in the cabinet and will require a certain amount of time to recover. Also after peak service periods or after warm product is loaded the refrigerator will require a certain amount of time for the temperature to return to the normal operating range.
e – PANS & DIVIDER BARS-TOP RAIL:
Sandwich Prep models are provided with 1/6 size plastic pans and metal divider bars. When 18 one sixth size pans are ordered, four standard and one wide pan divider/supports are provided to achieve appropriate pan separation. When 24 one-sixth size pans re ordered, six standard and one wide pan divider bars are provided to achieve appropriate pan separation. All other arrangements use all standard width pan divider bars.
f – DIVIDER BARS-DRAWERS:
Drawer models are provided with metal divider bars standard. All 27” wide models are supplied with 2 bars, 32” wide models are supplied with 2 narrow bars and 1 wide bar and 60” wide models are supplied with 2 bars and 1 hook divider bar, per drawer.
CARE AND MAINTENANCE
a – CLEANING THE EXTERIOR:
Exterior stainless steel should be cleaned with warm water, mild soap and a soft cloth. Apply with a dampened cloth and wipe in the direction of the metal grain.
Avoid the use of strong detergents and gritty, abrasive cleaners as they may tend to mar and scratch the surface. Do NOT use cleaners containing chlorine, this may promote corrosion of the stainless steel.
b – CLEANING THE INTERIOR:
For cleaning the interior, the use of baking soda as described in section V. a is recommended. Use on breaker strips as well as door and drawer gaskets.
All door models interior fittings are removable without tools to facilitate cleaning.
Depending on the level of cleaning, drawer models interior fittings may
require a tool to facilitate cleaning. The drawer frame may be removed without
tools by simply pulling out and upward. For deeper cleaning the back panel
shown in the bubble drawing will require a Phillips screwdriver to be removed.
For additional deeper cleaning you may also remove the air duct by removing
the thumb screws and rotating them in counter clockwise motion.
c – CLEANING THE CONDENSER COIL:
Check the condenser coil periodically. The operating environment will affect
the required frequency of cleaning. Air must be able to freely circulate
through
the condenser. This surface must be kept free of dirt and grease for proper
system operation. Remove the lower rear panel on the rear of the equipment
cabinet. Carefully clean dirt and lint from the condenser coil using a vacuum
cleaner or soft brush; do not use a wire brush. Replace the lower rear panel.
Reconnect electrical power supply
d – CONDENSATE REMOVAL SYSTEM CARE:
The evaporator coil, condensate loop and condensate pan, when needed, can all
be flushed with fresh water by a qualified service technician. This should be
part of any routine maintenance program and can prolong the lifeof the
equipment.
Condensate removal is provided by evaporation at the lower rear portion of the
equipment cabinet and does not need a drain. Periodic cleaning of the
condensate removal box, remove the lower panel at the rear of the equipment
cabinet. Clean the condensate removal box by wiping it out with a clean damp
cloth, using care with the condensate loop inside. Replace the lower rear
panel. Reconnect electrical power supply.
WARNING: DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT.
MISC. OPERATIONS
a – REHINGING THE DOOR:
The door(s) on all UHT, ULT, UPT & UST models can be easily rehinged in the
field. To begin, open the door to its maximum position. Support the nonh nged
end of the door so minimum movement occurs when the bolts from the lower hinge
plate are removed. Remove the lower hinge plate and then
the door from the top hinge bracket. The hinge plate pin and plastic bushing
will remain in the top hinge plate.
Lay the door down on a padded flat surface while being careful not to allow the lower hinge plate and mechanism stem to slide out the bottom of the door.
NOTE: The lower hinge plate is under spring tension. Grasp the lower
hinge plate while keeping a firm grip on the plate, carefully slide it out the
bottom of the door just far enough to allow the plate to rotate a full 3600 .
Unwind the tension of the spring by carefully allowing the hinge plate to
rotate a full 3600 several times.
Slide the hinge plate and hinge mechanism stem out the bottom of the door.
b – PREPARING FOR EXTENDED SHUT DOWN:
NOTE: Remove the brass bushing from the bottom of the door only if spring replacement is necessary. Both the spring and bushing will need to be new parts
NOTE: When installing, make sure the lower hinge plate and hinge mechanism stem are rotated no more than six (6) full turns while applying tension to the spring.
To reinstall the door, position the lower hinge plate into the position of being open 900 to the cabinet. Place the top hinge plate pin in the hole in the top of the door and support the other end of the door for minimal movement. Start the bolts in the lower hinge plate and tighten the bolts enough to hold the door in place. Remove the block from under the end of the door. Adjust the door.
If the refrigerator is not to be used for an extended period of time, disconnect the electrical power supply and open the doors. As soon as the cabinet has warmed up to room temperature, wipe out the interior. Leave the doors open and check again to make sure that no moisture has collected on any parts. To restart refrigerator, follow instructions under PRESTART CHECKS and OPERATION.
c – ADJUSTING THE DOOR:
Occasionally the door(s) may require alignment adjustment. To do so, first
open the door and loosen the hinge plate screws enough to move the hinges if
desired, but the door is held in place. Center the door in the opening. Next
level the top hinge plate and tighten the screws. Finally, level the lower
hinge plate and tighten the screws.
d – DOOR & DRAWER GASKET(S) REPLACEMENT:
Remove the old gasket by pulling it out from the gasket retainer. Next, install the four corners of the new gasket by pushing straight in on the gasket until it is hooked behind the gasket retainer. Be careful not to stretch the gasket as it will not return to its original length. Starting at the center of one edge, push the gasket straight in until it is hooked behind the gasket retainer. Proceeding from this point out to the corners, continue pushing the gasket straight into the gasket retainer. Proceed doing the same to each of the remaining edges until the gasket is completely installed.
TROUBLE SHOOTING GUIDE
PROBLEM | POSSIBLE SOLUTION |
---|---|
1. Condensing unit fails to start. | a. Check if cord & plug has been |
disconnected.
b. Check thermostat temperature setting.
2. Condensing unit operates for prolonged periods or con- tinuously.| a.
Are doors or drawers closed properly?
b. Dirty condenser or filter. Clean properly.
c. Evaporator coils iced. Needs to defrost.
3. Food Compartment is too warm.| a. Check door(s) or drawers and gasket(s)
for proper seal.
b. Check if a large quantity of warm food was recently added or the door or
drawer was kept open for a long period of time. Allow adequate time for the
cabinet to recover its normal operating temperature.
c. Thermostat setting to high. Readjust per instructions.
d. Check that condensing coil is clean.
4. Food Compartment is too cold.| a. Check if a large quantity of very cold
or frozen food has recently been added. Allow adequate time for the cabinet to
recover its normal operating temperature.
b. Adjust the thermostat to a warmer setting.
5. Condensation on exterior surface.| a. Check door(s) or drawer(s)
alignment and gaskets for proper seal.
b. Condensation on the exterior surface of the unit is perfectly normal
during periods of high humidity.
6. Compressor hums & does not start.| a. Call for service.
SERVICE ASSISTANCE
Before calling for service, please check the following:
- Is the electrical cord plugged in?
- Is the fuse OK or circuit breaker on?
- Clean condenser coil
- Is the power switch on?
If after checking the above items and the unit is still not operating properly, please contact an authorized Traulsen service agent. You may obtain the name of a service agent from the Service Directory page of our web site: www.traulsen.com. Please note, you will be required to register for a login name and pass code to access our directory. If service is not satisfactory, please contactour in-house service department at:
Traulsen
4401 Blue Mound Road
Fort Worth, TX 76106
800-825-8220
Traulsen reserves the right to change specifications or discontinue models without notice.
b – SERVICE SUPPORT INFORMATION:
To purchase replacement parts or to speak to service support for Traulsen and most Hobart refrigeration units please contact our Ft. Worth facility by phone at 800-825-8220 or fax to 817-740-6748 (parts) or 817-740-6757 (service).
Note: When calling for spare parts or service support, please make sure you have model and serial number of unit available.
To source service support locally follow instructions below for nearest authorized service agent. Please note, you will be required to register for a login name and pass code to access our directory
- Log onto www.traulsen.com
- Select Contact Us/Dealer Directory (top right of screen)
- Click on Service Directory tab
- Select state by using the drop down box
- Select Go
c – WARRANTY REGISTRATION:
The warranties for your new Traulsen unit may be registered with us by contacting our Ft. Worth facility directly by phone at 800-825-8220 or you may register on- line. Please note, you will be required to register for a login name and pass code to access our on line registration.
- Log onto www.traulsen.com
- Select Contact Us/Dealer Directory (top right of screen)
- Select Warranty Registration (lower right of screen)
- Fill out information requested
- Select Submit to complete unit warranty registration
WARRANTIES
Warranties
STANDARD DOMESTIC WARRANTY
TRAULSEN warrants new equipment to the original purchaser, when installed
within the United States against defective material and workmanship for one
(1) year from the date of original installation. Under this warranty, TRAULSEN
will repair or replace, at its option, including service and labor, all parts
found to be defective and subject to this warranty. The compressor part is
warranted for an additional four (4) years. During this period TRAULSEN will
supply replacement compressor(s) if deemed defective, however all
installation, recharging and repair costs will remain the responsibility of
the owner.
This warranty does not apply to damage resulting from fire, water, burglary,
accident, abuse, misuse, transit, acts of God, terrorism, attempted
repairs,improper installation by unauthorized persons, and does not apply to
food loss.
For Traulsen units purchased with a remote feature, standard warranty will
apply only to those components contained within the unit to the point of
connection of the refrigeration lines leading to the remote condense
THERE ARE NO ORAL, STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN,
INCLUDING BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF MERCHANTABILITY OR
FITNESS FOR ANY PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION ON THE
FACE HEREOF. TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL
OR SPECIAL DAMAGES, GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS
SALE, OPERATION OR USE, AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE
ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE
EQUIPMENT OR ITS SALE, OPERATION OR USE OTHER THAN AS STATED HEREIN.
INTELA-TRAUL® CONTROL WARRANTY
TRAULSEN warrants to the original purchaser of the INTELA-TRAUL® control when
installed as part of the Refrigeration/Hot Food Equipment manufactured and
sold by TRAULSEN, to be free of defects in material andworkmanship under
normal service and use for a period of two (2) years from the date of
installation. Under this warranty statement, TRAULSEN will repair or exchange
at TRAULSEN’S discretion, F.O.B. factory, any part of said control, which
proves to be defective. Inspection by the TRAULSEN Service Department of parts
claimed defective shall be final in determining warranty status. The warranty
is to include repair or exchange of any defective In Warranty control or
part(s) of said control for:
Part(s) – Any TRAULSEN INTELA-TRAUL® supplied part(s) found to be defective.
Labor – The labor charges from a TRAULSEN certified service agent to effect
the repair or exchange of the defective part(s).
“Defective Part Return” – All claimed defective part(s) must be returned to
TRAULSEN for defect validation within 30 days from the date of the repair.
Failure to return all claimed defective part(s) to TRAULSEN will invalidate
the warranty claim, this warranty statement, and forfeit payment for those
repairs effected.
This warranty does not apply to damage resulting from fire, water, burglary,
accident, abuse, misuse, transit, acts of God, terrorism, attempted repairs,
improper installation by unauthorized persons, and does not apply to food
loss, and will not apply if said equipment is located outside The United
States.
G-SERIES MICROPROCESSOR CONTROL WARRANTY
TRAULSEN warrants to the original purchaser of the G-Series Microprocessor
control when installed as part of the Refrigeration Equipment manufactured and
sold by TRAULSEN, to be free of defects in material and workmanship under
normal service and use for a period of one (1) year from the date of
installation. Under this warranty statement, TRAULSEN will repair or exchange
at TRAULSEN’S discretion, F.O.B. factory, any part of said control, which
proves to be defective. Inspection by the TRAULSEN Service Department of parts
claimed defective shall be final in determining warranty status. The warranty
is to include repair or exchange of any defective In Warranty control or
part(s) of said control for:
Part(s) – Any TRAULSEN G-Series Microprocessor Control supplied part(s) found
to be defective.
Labor – The labor charges from a TRAULSEN certified service agent to effect
the repair or exchange of the defective part(s).
Defective Part Return” – All claimed defective part(s) must be returned to
TRAULSEN for defect validation within 30 days from the date of the repair.
Failure to return all claimed defective part(s) to TRAULSEN will invalidate
the warranty claim, this warranty statement, and forfeit payment for those
repairs effected.
This warranty does not apply to damage resulting from fire, water, burglary,
accident, abuse, misuse, transit, acts of God, terrorism, attempted repairs,
improper installation by unauthorized persons, and will not apply to food
loss, and will not apply if said equipment is located outside The United
States.
INTERNATIONAL COMMERCIAL WARRANTY
TRAULSEN warrants to the original purchaser the Refrigeration Equipment
manufactured and sold by it to be free from defects in material and
workmanship under normal use and service for a period of one (1) year from
date of shipment. Under this warranty, TRAULSEN will reimburse the purchaser
for the replacement of any part of saidequipment (excluding dryers &
refrigerant gas) which then proves to be defective. This warranty does not
apply to damage resulting from fire, water, burglary, accident, abuse, misuse,
transit, acts of God, terrorism, attempted repairs, improper installation by
unauthorized persons, and will not apply to food loss.
TRAULSEN’S standard warranty does not apply to Export Sales. Rather, for a
period of one (1) year from date of original installation not to exceed
Fifteen (15) months from date of shipment from factory, TRAULSEN:
will replace, F.O.B. factory, any defective parts normally subject to
warranty.
will not cover the cost of packing, freight or labor such costs being the sole
responsibility of the dealer
THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR
IMPLIED AND CONSTITUTES TRAULSEN’S FULL OBLIGATION AND LIABILITY.
WARRANTIES NOT AVAILABLE ON REMOTE MODELS.
X. SERVICE PARTS LIST
Note: Part numbers listed are for standard products as currently manufactured. For products manufactured as other than standard, please contact the factory.
ITEM | DESCRIPTION | PART NUMBER |
---|---|---|
C ASTERS | 6” CASTER – 60” MODELS | CASTER 5SET6 |
6” CASTER – 27”, 32” & 48” MODELS | CASTER 5SET4 | |
4” CASTER – 60” MODELS | CASTER 60SET3 | |
4” CASTER – 27”, 32” & 48” MODELS | CASTER SET4IN | |
3 1/2” CASTER – 60” MODELS | CASTER SET4 | |
3 1/2” CASTER – 27” , 32” & 48” MODELS | CASTER SET3IN | |
2 1/2” CASTER – 27” MODELS | CASTER SET2IN | |
HINGE | REPLACEMENT HINGE | SER-60248-00 |
REPLACEMENT HINGE CARTRIDGE | SER-60249-00 | |
SHELVES | SHELF – 27” MODELS | SHELF CPW1 |
SHELF – 32” MODELS | SHELF CPW2 | |
SHELF – 48” MODELS (UPPER) | SHELF48 UPPER | |
SHELF – 48” MODELS (LOWER) | SHELF48 LOWER | |
SHELF – 60” MODELS (UPPER) | SHELF60 UPPER | |
SHELF – 60” MODELS (LOWER) | SHELF60 LOWER | |
SHELF CLIP | SHELF CLIP – ALL MODELS | SER-60269-00 |
THERMOMETER | THERMOMETER – ALL MODELS | SER-60268-00 |
TOP, BACKSPLASH | BACKSPLASH TOP – 27” MODELS | CU27TOP BSWO |
BACKSPLASH TOP – 32” MODELS | CU32TOP BSWO | |
BACKSPLASH TOP – 48” MODELS | CU48TOP BSWO | |
BACKSPLASH TOP – 60” MODELS | CU60TOP BSWO | |
DRAWER 27 COMPACT | DRAWER ASSEMBLY | 550-10234-00 |
DRAWER TOP | 550-10214-00 | |
DRAWER BOTTOM | 550-10233-00 | |
DRAWER FACE ASSEMBLY TOP | 550-10216-00 | |
DRAWER FACE ASSEMBLY BOTTOM | 550-10216-01 | |
DRAWER FRAME ASSEMBLY TOP/BOTTOM | 550-10135-01 | |
DRAWER SUPPORT LEFT | 550-10231-00 | |
DRAWER SUPPORT RIGHT | 550-10232-00 | |
DRAWER SLIDING RAIL LEFT | 550-10230-00 | |
DRAWER SLIDING RAIL RIGHT | 550-10230-01 | |
DRAWER CROSSRAIL | 550-10215-00 | |
DRAWER GASKET TOP | 341-60099-02 | |
DRAWER GASKET BOTTOM | 341-60099-03 | |
DRAWER ROLLER | 344-41808-01 | |
DIVIDER | 701-60774-00 | |
DRAWER 32 COMPACT | DRAWER ASSEMBLY | 550-10236-00 |
DRAWER TOP | 550-10222-00 | |
DRAWER BOTTOM | 550-10235-00 | |
DRAWER FACE ASSEMBLY TOP | 550-10224-00 | |
DRAWER FACE ASSEMBLY BOTTOM | 550-10224-01 | |
DRAWER FRAME ASSEMBLY TOP/BOTTOM | 550-10209-01 | |
DRAWER SUPPORT LEFT | 550-10231-00 | |
DRAWER SUPPORT RIGHT | 550-10232-00 | |
DRAWER SLIDING RAIL LEFT | 550-10230-00 | |
DRAWER SLIDING RAIL RIGHT | 550-10230-01 | |
DRAWER CROSSRAIL | 550-10223-00 | |
DRAWER GASKET TOP | 341-60099-04 | |
DRAWER GASKET BOTTOM | 341-60099-05 | |
DRAWER ROLLER | 344-41808-01 | |
DIVIDER NARROW | 701-61258-03 | |
DIVIDER WIDE | 701-61258-04 | |
DRAWER 60 COMPACT | DRAWER ASSEMBLY FIRST OPENING | 550-10239-00 |
DRAWER ASSEMBLY SECOND OPENING | 550-10239-01 | |
DRAWER TOP | 550-10214-02 | |
DRAWER BOTTOM | 550-10233-00 | |
DRAWER FACE ASSEMBLY TOP | 550-10216-00 | |
DRAWER FACE ASSEMBLY BOTTOM | 550-10216-01 | |
DRAWER FRAME ASSEMBLY TOP | 550-10135-03 | |
DRAWER FRAME ASSEMBLY BOTTOM | 550-10135-01 | |
DRAWER SUPPORT LEFT FIRST OPENING | 550-10231-00 | |
DRAWER SUPPORT RIGHT FIRST OPENING | 550-10237-00 | |
DRAWER SUPPORT LEFT SECOND OPENING | 550-10238-00 | |
DRAWER SUPPORT RIGHT SECOND OPENING | 550-10232-00 | |
DRAWER SLIDING RAIL LEFT | 550-10230-00 | |
DRAWER SLIDING RAIL RIGHT | 550-10230-01 | |
DRAWER CROSSRAIL | 550-10215-00 | |
DRAWER GASKET TOP | 341-60099-02 | |
DRAWER GASKET BOTTOM | 341-60099-03 | |
DRAWER ROLLER | 344-41808-01 | |
DIVIDER WITH HOOKS | 601-61110-00 | |
DIVIDER | 701-60774-00 |
HOURS OF OPERATION:
Monday thru Friday 7:30 am – 4:30 pm CST
Traulsen
4401 Blue Moud Road Fort Worth, TX 76106
Phone800-825-8220 Fax
817-740-6757
Website:www.traulsen.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>