Product information

Specifications

  • Model: EDM-200
  • Languages: ES, EN, FR, DE, NL, PT, SV, PL, IT, CS, AR

Description

The EDM-200 range extractors have been manufactured to the rigorous standards of production and quality as laid down by the international quality standards ISO 9001. All the components have been checked and all the final products have been tested at the end of the manufacturing process.

Installation

IMPORTANT: Before installing and wiring the EDM, ensure that the main supply is disconnected.

  1. Check that the product is the correct size and model.
  2. Verify that the details on the rating label are those you require, including voltage and frequency.
  3. The installation must be under the electrical standards in force in your country.

Electrical connection

This appliance is considered to be suitable for use in countries
having a warm damp equable climate as specified in IEC 60721-2-1.
It may also be used in other countries.

EDM models S and C:

For these models, use the following diagrams:

  • Fig. 4: Switching the extractor through the light switch.
  • Fig. 5: To switch the fan through an independent switch.

EDM models T, CT, and CR:

These models are fitted with an automatic shutter. The opening
of the shutter is facilitated using a thermal system that
needs a few seconds to open completely.

EDM models H and CH:

Models H and CH are provided with an electronic hygrostat which can be adjusted from 60 to 90% RH (relative humidity). They are fitted with a pull cord switch (IC) enabling override of the fan when the relative humidity level in the room is lower than the set % RH value. A variable %RH rotary switch within the fan can be adjusted after removing the grille (Fig. 8b). Alternatively, the EDM-H and CH can be powered by the light switch in preference to the pull cord switch.

Surgery

When the extractor is operated by Hygrostat, the red pilot lamp on the grille of the EDM is not on.

Case 2: Automatic operation with pull cord override facility (Fig. 10):

Automatic operation as in case 1 with the facility to override the hygrostat employing the pull cord when the humidity level in the room is lower than the selected level on the rotary switch. When the pull cord is used to power the fan, the red pilot lamp (L) turns on. When the relative humidity level in the room is higher than the level selected on the rotary switch, the automatic operation overrides the manual operations (ie pull cord or light switch), that is, the extractor cannot be stopped by either the pull cord or the light switch.

Maintenance

Regular maintenance should be carried out to ensure optimal performance of the EDM-200 extractor. Please refer to the maintenance instructions provided in the user manual.

Disposal and recycling

When disposing of the EDM-200 extractor, follow proper waste disposal guidelines and regulations. Ensure that the product is recycled or disposed of in an environmentally friendly manner.

Frequently Asked Questions (FAQ)

  1. What languages ​​are supported by the EDM-200 extractor?
  2. What are the electrical requirements for the EDM-200 extractor?
  3. How do I install the EDM-200 extractor?
  4. Can the extractor be controlled by a light switch?
  5. What is the purpose of the electronic hygrostat in models H and CH?
  • The EDM-200 range extractors have been manufactured to the rigorous standards of production and quality as laid down by the international Quality Standards ISO 9001.
  • All the components have been checked and all the final products have been tested at the end of the manufacturing process.

We recommend you check the following when receiving this product:

  1. That is the correct size.
  2. That is the correct model.
  3. That the details on the rating label are those you require: voltage, and frequency.

The installation must be under the electrical standards in force in your country.

INSTALLATION

IMPORTANT: Before installing and wiring the EDM, ensure that the main supply is disconnected.

Fig.1:S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-
FIG-1

  1. Protection grille
  2. Cable entry
  3. Flange
  4. Fixing screw
  5. Connection terminals
  6. Outlet
  7. Slot
  • The EDM can be installed on a wall or ceiling, and the discharge can be made directly to the outside or ducting (individual or shunt, fig. 2).S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-2
  • The hole to be made on the wall or the ceiling must have the following diameter: 125 mm.
  • Loosen the screw (4) fixing the grille (1). Bind the adhesive tape supplied around the outlet (6).
  • If the installation is made to an individual ducting, use standard ducting: 120 or 125 mm.
  • Ensure that there are no obstructions to the airflow and that the impeller turns freely.
  • Fix the extractor to the wall with the 4 plugs and screws supplied in the packaging.
  • The unit must be fixed in such a way that it is not stressed, to avoid noise generation or problems in the rotation of the impeller.
  • Connect the electrical wiring as explained hereafter and then mount the protection grille and fixed it by tightening the screw (4).

ELECTRICAL CONNECTION

  • This appliance is considered to be suitable for use in countries having a warm damp equable climate as specified in IEC 60721-2-1. It may also be used in other countries.
  • The EDM is an extractor designed for a single-phase supply, with voltage and frequency as indicated on the rating plate of the unit. The units are made with double electrical insulation (Class II) and therefore they do not need an earth connection.
  • The electrical installation must include a double pole switch with a contact clearance of at least 3 mm.
  • The electrical cable must be introduced to the EDM through slot (7) if the wire is within the wall, or through the cable entry (2) if the installation is with a surface-mounted cable; in this case, the cable must be introduced as shown on Fig. 3b and not as shown on Fig. 3a.S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-3
  • Once the cable has been introduced, fix it with the flange (3) and proceed to the appropriate electrical wiring depending on the EDM model.

EDM models S and C

  • For these models use the following diagrams:
  • Fig. 4: Switching the extractor through the light switch.S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-4
  • Fig. 5: To switch the fan through an independent switch.S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-5

EDM models T, CT, and CR

  • Models fitted with fixed (approx. 9 minutes) not adjustable timer (T and CT) or adjustable (CR). The timer enables the extractor to continue running during the time delay after the switch has been switched off (Fig. 6).S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-6
  • The diagram in Fig. 7 shows how to connect a unit fitted with a timer using the light switch.S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-7
  • Model CR has an adjustable timer. To adjust the timer, turn the rotary switch on the Printed Circuit Board (Fig. 8a):S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-8
  • To decrease the time delay turn it Counter Clockwise (CCW).
  • To increase the time delay turn it Clockwise (CW).

EDM models C, CT, CR, and CH

  • These models are fitted with automatic shutters.
  • WARNING: The opening of the shutter is facilitated through a thermal system that needs some seconds to open completely.

EDM models H and CH

  • Models H and CH are provided with an electronic hygrostat which can be adjusted from 60 to 90% RH (% relative humidity).
  • They are fitted with a pull cord switch (IC) enabling override of the fan when the relative humidity level in the room is lower than the set % RH value.
  • A variable % RH rotary switch within the fan can be adjusted after removing the grille (Fig. 8b).
  • Alternatively, the EDM-H and CH can be powered by the light switch in preference to the pull cord switch.

OPERATION

Case 1: Automatic operation (Fig. 9)S P-EDM-200-25-W-Bathroom-Toilet-
Extractor-Fan-FIG-9

  • In this mode, the pull cord switch is enclosed behind the grille, in the «off» position (The pilot lamp will not switch on).
  • The hygrostat causes the extractor to operate automatically when the humidity level in the room is higher than the level shown on the variable rotary switch.
  • Likewise, the extractor will stop automatically when the humidity level drops below the selected level.
  • WARNING: When the extractor is operating by hygrostat, the red pilot lamp on the grille of the EDM is not on.
  • Case 2: Automatic operation with pull cord override facility (Fig. 10).S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-10
  • Automatic operation as in case 1 with the facility to override the hygrostat through the pull cord when the humidity level in the room is lower than the selected level on the rotary switch.
  • When the pull cord is used to power the fan the red pilot lamp (L) turns on.
  • Case 3 : Automatic operation with the facility to override by a light switch (Fig. 11).S P-EDM-200-25-W-Bathroom-Toilet-Extractor-Fan-FIG-11
  • The operation of the extractor is the same as in case 2 although, the EDM is connected to the light switch (IL) instead of the pull cord.
  • In this case, leave the pullcord inside the fan in the «off» position.
  • WARNING: When the relative humidity level in the room is higher than the level selected on the rotary switch, the automatic operation overrides the manual operations (i.e.pull cord or light switch), that is, the extractor cannot be stopped by either the pull cord or the light switch.

USER INSTRUCTION

  • This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge.
  • If they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved.
  • Children shall not play with the appliance.
  • Cleaning and user maintenance shall not be done by children without supervision.

MAINTENANCE

  • The extractor needs only a periodical cleaning using a cloth lightly impregnated with a soft detergent.

AFTER-SALES SERVICE

  • We recommend you not dismantle or remove any other parts than those mentioned as any tampering would automatically cancel the S&P guarantee.
  • If you detect any fault, contact your S&P dealer.
  • S&P reserves the right to alter specifications without notice.

PUTTING OUT-OF-SERVICE AND RECYCLING

  • EEC legislation and our consideration of future generations mean that we should always recycle materials where possible; please do not forget to deposit all packaging in the appropriate recycling bins.
  • If your device is also labeled with this symbol, please take it to the nearest Waste Management Plant at the end of its serviceable life.
  • S &P SISTEMAS DE VENTILACIÓN, S.L.U.
  • C. Llevant, 4
  • Polígono Industrial Llevant
  • 08150 Parets del Vallès
  • Barcelona – España
  • Tel. +34 93 571 93 00
  • www.solerpalau.com

Documents / Resources

| S P EDM-200 25 W Bathroom/Toilet Extractor Fan [pdf] User Manual
EDM-200 25 W Bathroom Toilet Extractor Fan, EDM-200, 25 W Bathroom Toilet Extractor Fan, Bathroom Toilet Extractor Fan, Toilet Extractor Fan, Extractor Fan, Fan
---|---

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals