OMRON HEM-7156T Automatic Blood Pressure Monitor Instruction Manual

June 4, 2024
Omron

OMRON LOGO

Instruction Manual
Automatic Blood Pressure

Monitor
Model HEM-7156TOMRON HEM7156T Automatic Blood Pressure
Monitor

Intellisense

HEM-7156T Automatic Blood Pressure Monitor

All for Healthcare
Read the Instruction manual1 and 2 before use.

  1. Package ContentsOMRON HEM7156T Automatic Blood Pressure Monitor - FIG

  2. Preparing for a Measurement
    30 minutes before 5 minutes before: Relax and rest.****

  3. Downloading the “OMRON connect” AppOMRON HEM7156T Automatic Blood Pressure Monitor - FIG3

  4. Installing BatteriesOMRON HEM7156T Automatic Blood Pressure Monitor - FIG4

  5. Pairing Your Smart DeviceOMRON HEM7156T Automatic Blood Pressure Monitor - FIG5 Follow the instructions.
    The date and time will automatically be set when your monitor is paired with the app.

  6. Setting Date and Time Manually
    **If your monitor is paired with your smart device, the date and time are set automatically. When you need to set them manually, set year > month > day

    hour > minute.OMRON HEM7156T Automatic Blood Pressure Monitor -
FIG6**

  7. Applying the Cuff on the Left ArmOMRON HEM7156T Automatic Blood Pressure Monitor - FIG7 3 Tube side of the cuff should be 1 – 2 cm above the inside elbow.
    4 Make sure that the air tube is on the inside of your arm and wrap the cuff securely so it can no longer slip around.
    If taking measurements on the right arm, refer to:

  8. Sitting CorrectlyOMRON HEM7156T Automatic Blood Pressure Monitor - FIG8
    1 Sit comfortably with your back and arm supported.
    2 Place the arm cuff at the same level as your heart.
    3 Keep feet flat, legs uncrossed, remain still, and do not talk.

  9. *Taking a MeasurementOMRON HEM7156T Automatic Blood Pressure Monitor - FIG9 When the [START/STOP] button is pressed, the measurement is taken and saved automatically. Open the app to transfer the reading.
    If your systolic pressure is more than 210 mmHg:
    After the arm cuff starts to inflate, press and hold the [START/STOP] button until the monitor inflates 30 to 40 mmHg higher than your expected systolic pressure.
    Taking a measurement in guest mode
    The guest mode can be used to take a single measurement for another user. No readings are stored in the memory.
    sec+: press the button for at least the specified number of seconds.
    **

  10. Checking Readings 1 Appears if “SYS” is 135 mmHg or above and/or “DIA” is 85 mmHg* or above.
    Appears when an irregular rhythm* is detected during measurement.
    If it appears repeatedly, OMRON recommends consulting your physician.
    Appears when your body moves during a measurement. Remove the arm cuff, wait 2-3 minutes and try again.
    Cuff is tight enough.
    Apply cuff again MORE TIGHTLY.
    The high blood pressure definition is based on the 2018 ESH/ESC Guidelines.
    An irregular heartbeat rhythm is defined as a rhythm that is 25 % less or 25 % more than the average rhythm detected during measurement.
    Error messages or other problems? Refer to:**

  11. Using Memory Functions
    11.1 Readings Stored in Memory
    Up to 60 readings are stored. 11.2 Average of the Latest 2 or 3 Readings Taken within a 10-Minute Span
    11.3 Deleting All ReadingsOMRON HEM7156T Automatic Blood Pressure Monitor -
FIG11****

  12. Other Settings
    12.1 Disabling/Enabling Bluetooth®
    Bluetooth is enabled by default. 12.2 Restoring to the Default SettingsOMRON HEM7156T Automatic Blood Pressure
Monitor - FIG11

  13. Optional Medical AccessoriesOMRON HEM7156T Automatic Blood Pressure Monitor - FIG10 Do does not throw the air plug away. The air plug can be applicable to the optional cuff.****

  14. Other Optional Parts AC Adapter For Korea: HHP-KSM01
    For Taiwan: HHP-AM01
    For Australia and New Zealand: HHP-OH01
    For India: HHP-BH01

https://www.omronhealthcare-ap.com/

**Manufacturer| OMRON HEALTHCARE Co., Ltd.**
53, Kunotsubo, Terado-Cho, Muko, KYOTO, 617-0002 JAPAN
---|---
RESMED 60648 Ultra Mirage Non Vented Full Face Mask - Release
Cord5EU-representative| OMRON HEALTHCARE EUROPE B.V.
Scorpius 33, 2132 LR Hoofddorp, THE NETHERLANDS
www.omron-healthcare.com
Importer in EU
Asia Pacific HQ| OMRON HEALTHCARE SINGAPORE PTE LTD.
www.omronhealthcare-ap.com
Production Facility| OMRON HEALTHCARE MANUFACTURING VIETNAM CO., LTD.
No.28 VSIP II, Street 2, Vietnam-Singapore Industrial Park II, Binh Duong Industry-Services-Urban Complex, Hoa Phu Ward, Thu Dau Mot City, Binh Duong Province, Vietnam
Importer in the Republic of Korea| OMRON HEALTHCARE KOREA Co., Ltd.
A-dong 18F, 465, Gangnam-daero, Seocho-gu, Seoul, Korea
Customer Service Center(1544-5718) www.omron-healthcare.co.kr

Made In Vietnam
Issue Date  2021-11-05