NIBE RPP 10 Wireless Repeater Smart Contact
Product Information
Specifications
- Product Name: RPP 10
- Model Number: UHB 2210-2 M12705
- Dimensions: 42x42x40 mm
- Maximum Load: 2,990W/13A
FAQ
- Q: What is the maximum load that can be connected to RPP 10?
- A: You can connect a maximum of 2,990W/13A to RPP 10.
- Q: How can I control RPP 10 manually?
- A: You can control RPP 10 manually using the remote control function in the app on your smartphone or on myuplink.com. Alternatively, you can use the physical button on RPP 10 to turn the power outlet on and off.
- Q: Can RPP 10 be scheduled?
- A: Yes, RPP 10 can be scheduled using your main product’s scheduling feature. Follow the guide in the main product to schedule the power outlet in RPP 10.
Product Information
RPP 10 is a wireless outlet that amplifies the signal between zones and improves the communication between your smart home products, if they are located a long way from the main product. RPP 10 has a built-in energy meter and continuously reports the energy consumption to your main product.
Functions
- RPP 10 requires the main product to have software version 2.0 or later.
- The Scheduling function requires software version 2.1.
Product Usage Instructions
Manual Control
There is a built-in function that allows you to control RPP 10 by remote control. Using the remote control function, you can turn the power outlet in RPP 10 on and off manually via the app on your smartphone and on myuplink.com. Alternatively, you can turn the power outlet on and off using the physical button on RPP 10.
Energy Meter
The energy consumption for products connected via the power outlet in RPP 10 is measured and reported. The measured value can be presented in two ways:
Scheduling
- RPP 10 can be controlled via your main product’s scheduling.
- In the main product, you follow a guide for scheduling the power outlet in RPP 10 to control the times at which the current is to be turned on and off.
Compatible Products
RPP 10 is compatible with the following products:
- 1x RPP 10
- 1x Quick guide
Connection
To connect RPP 10, follow the steps below:
- Place RPP 10 in the desired location.
- Connect the main product to RPP 10 using the provided cables.
- Ensure that the LED indicators on RPP 10 are functioning properly.
LED Indications
The LED indicators on RPP 10 provide important information. Here are the different LED indications:
- Namn enhet: Indicates that RPP 10 is in identification mode.
- Identifiera: Indicates that RPP 10 is identifying connected devices.
- Ta bort enhet: Indicates that RPP 10 is removing a connected device.
Important information
SAFETY INFORMATION
This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
This is an original manual. It may not be translated without the approval of
NIBE.
Rights to make any design or technical modifications are reserved.
©NIBE 2023.
SYMBOLS
Explanation of symbols that may be present in this manual.
- NOTE: This symbol indicates danger to person or machine.
- Caution: This symbol indicates important information about what you should observe when maintaining your installation.
- TIP: This symbol indicates tips on how to facilitate using the product.
General
RPP 10 is a wireless outlet that amplifies the signal between zones and improves the communication between your smart home products, if they are located a long way from the main product. RPP 10 has a built-in energy meter and continuously reports the energy consumption to your main product.
NOTE
- If RPP 10 loses contact with the main product, RPP 10 will try to reconnect for 60 minutes, if the reconnection fails, the power supply to the output socket in RPP 10 will be turned off.
- Therefore, do not connect equipment that is sensitive to power outages.
MAXIMUM LOAD
- You can connect a maximum of 2,990W/13A to RPP 10.
FUNCTIONS
Caution
- RPP 10 requires the main product to have software version 2.0 or later.
- The “Scheduling” function requires software version 2.1.
MANUAL CONTROL
There is a built-in function that allows you to control RPP 10 by remote control. Using the remote control function, you can turn the power outlet in RPP 10 on and off manually via the app on your smartphone and on myuplink.com. Alternatively, you can turn the power outlet on and off using the physical button on RPP 10.
ENERGY METER
The energy consumption for products connected via the power outlet in RPP 10 is measured and reported. The measured value can be presented in two ways:
- Current consumption (W)
- Total consumption (kWh)
SCHEDULING
- RPP 10 can be controlled via your main product’s scheduling.
- In the main product, you follow a guide for scheduling the power outlet in RPP 10 to control the times at which the current is to be turned on and off.
COMPATIBLE PRODUCTS
- S1155/S1255
- VVM S320
- SMO S40
- VVM S325
CONTENTS
- 1 x RPP 10
- 1 x Quick guide
Climate systems and zones
- Multiple climate systems are used when different supply temperatures are required for different parts of the system, for example when both underfloor heating and radiators are fitted in a property.
- A climate system can be divided up into several zones, which can be allocated one or more sensors or other accessories.
- A zone could be a specific room or part of larger premises.
OUTLINE DIAGRAM WITH CLIMATE SYSTEMS AND ZONES
The example shows a property with two climate systems. Climate system 1 is a radiator system with two zones. Zone 1 is the controlling zone and there are two THS 10 installed, which means that the heat pump extracts the heat from the stove more rapidly. Zone 2 is the zone displayed, which means that the temperature and humidity can be read off in the myUplink app or via myuplink.com. Climate system 2 is an underfloor heating system with one zone, which is the controlling zone.
Connection
Pairing is performed in the heat pump’s/control module’s display, select menu 5.4 – Connect wireless units.
PAIR YOUR WIRELESS ACCESSORY WITH YOUR MAIN PRODUCT
MENU 5.4 – CONNECT WIRELESS UNITS
- Here, you connect your wireless units. Press “Add unit” and follow the guide that is launched. You can also check the connected units’ battery level and signal strength.
CONNECT TO NETWORK
- RPP 10 must be connected to an outlet in order to connect to a network.
- If RPP 10 is flashing red (once every five seconds), it is searching for a wireless network to connect to. If no network is found, searching stops after 5 minutes. You can start a new search by pressing and holding the button on RPP 10 for 3 seconds.
- If you need to test the range of the signal, RPP 10 can be connected to the heat pump at close range and then moved further away. Wait for at least 30 minutes. The signal strength can then be read off in the heat pump’s/control module’s menu system (menu 5.4).
- To leave a network and reset RPP 10, press and hold the button for 10 seconds and wait until the red LED comes on for 5 seconds.
LOCATION
- Place RPP 10 in a free space to achieve the best range; you should therefore avoid locations such as between shelves and behind curtains.
- In a free space, RPP 10 has a maximum range of 30 m.
LED INDICATIONS
LED | Explanation |
---|---|
Red LED comes on for five seconds | Factory reset |
Red LED flashes once every five seconds | Connecting to network |
Red LED flashes once every second | The unit is overheated |
Red LED flashes three times within five seconds | Lost connection or unit is |
not connected to network
Green LED comes on| Relay ON
Green LED does not come on| Relay OFF
Program settings
MENU SETTINGS
Caution
- RPP 10 is not connected to a zone, and therefore you cannot make the same settings as with other wireless units.
MENU 5.4 – WIRELESS UNITS
- In this menu you connect wireless units, and manage settings for connected units.
- Add the wireless unit by pressing “Add unit”. For the quickest identification of a wireless unit, it is recommended that you put your master unit in search mode first.
- Then put the wireless unit in identification mode.
MENU 5.4.5 – REPEATER RPP 10
- Name unit
- Enter a name for the relevant repeater.
- Identify
- Setting range: on/off
- Delete unit
- Setting range: yes/no
Name unit: Here, you name your repeater RPP 10.
Identify: When the function is activated, the LED indicator on RPP 10
flashes green so it can be identified.
Delete unit: Here, you can choose to remove the unit.
MENU 6.2 – SCHEDULING
- In this menu, you schedule the power outlet in RPP 10 to control the times at which the current will be turned on and off.
Caution
- A schedule repeats according to the selected setting (e.g. every Monday) until you go into the menu and switch it off.
Technical specifications
RPP 10
Part No.| 067726
| |
Dimensions WxHxD| (mm)| 42x42x40
Contact Information
AUSTRIA
- KNV Energietechnik GmbH
- Gahberggasse 11, 4861 Schörfling
- Tel: +43 (0)7662 8963-0
- mail@knv.at
- knv.at
FINLAND
- NIBE Energy Systems Oy Juurakkotie 3, 01510 Vantaa
- Tel: +358 (0)9 274 6970
- info@nibe.fi
- nibe.fi
GREAT BRITAIN
- NIBE Energy Systems Ltd
- 3C Broom Business Park, Bridge Way, S41 9QG Chesterfield
- Tel: +44 (0)330 311 2201
- info@nibe.co.uk
- nibe.co.uk
POLAND
- NIBE-BIAWAR Sp. z 0.0.
- Al. Jana Pawla || 57, 15-703 Bialystok
- Tel: +48 (0)85 66 28 490
- biawar.com.pl
NETHERLANDS
- NIBE Energietechniek B.V.
- Energieweg 31, 4906 CG Oosterhout
- Tel: +31 (0)168 47 77 22
- info@nibenl.nl
- nibeni.nl
SWEDEN
- NIBE Energy Systems
- Box 14|
- Hannabadsvägen 5, 285 21 Markaryd
- Tel: +46 (0)433-27 30 00
- info@nibe.se
- nibe.se
DENMARK
- Velund Varmeteknik A/S
- Industrivej Nord 7B, 7400 Herning
- Tel: +45 97 17 20 33
- info@volundvt.dk
- volundvt.dk
GERMANY
- NIBE Systemtechnik GmbH
- Am Reiherpfahl 3, 29223 Celle
- Tel: +49 (0)5141 75 46 -0
- info@nibe.de
- nibe.de
NORWAY
- ABK-Qviller AS
- Brobekkveien 80, 0582 Oslo
- Tel: (+47) 23 17 05 20
- post@abkqviller.no
- nibe.no
SWITZERLAND
- NIBE Wärmetechnik c/o ait Schweiz AG
- Industriepark, CH-6246 Altishofen
- Tel. +41 (0)58 252 21 00
- info@nibe.ch
- nibe.ch
NIBE Energy Systems
- Hannabadsvägen 5 Box 14
- SE-285 21 Markaryd
- info@nibe.se
- nibe.eu
This is a publication from NIBE Energy Systems. All product illustrations,
facts and data based on current information at the time of publication
approval.
NIBE Energy Systems reserves the right for any factual or printing errors.
©2023 NIBE ENERGY SYSTEMS
References
- Polski producent podgrzewaczy wody i kotłów CO | Producent zasobników pionowych C.W.U | Biawar
- Wärmepumpen und effiziente Energiesysteme von KNV
- myUplink Web
- Heat pumps for sustainable energy solutions | NIBE
- Qlipcast
- Vølund Varmeteknik - varmeløsninger og varmepumper
- Polski producent podgrzewaczy wody i kotłów CO | Producent zasobników pionowych C.W.U | Biawar
- Wärmepumpen und effiziente Energiesysteme von KNV
- Vølund Varmeteknik - varmeløsninger og varmepumper
- Heat pumps for sustainable energy solutions | NIBE
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>