SCHMERSAL AZM161CC-12 Solenoid Interlock
Product Information
Specifications
- Product Name: Solenoid interlock AZM161CC-12/12RKA-M16-24V
FAQ
- Q: Can the Solenoid interlock AZM161CC-12/12RKA-M16-24V be used by private consumers?
- A: No, the Schmersal range of products is not intended for private consumers.
- Q: Who is responsible for ensuring the correct functionality of the entire machine or plant?
- A: It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
- Q: Where can I find further technical information about the Solenoid interlock AZM161CC-12/12RKA-M16-24V?
- A: You can find further technical information in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
About this document
Function
This document provides all the information you need for the mounting, set-up and commissioning to ensure the safe operation and disassembly of the switchgear. The operating instructions enclosed with the device must always be kept in a legible condition and accessible.
Target group of the operating instructions: authorised qualified personnel
- All operations described in the operating instructions manual must be carried out by trained specialist personnel, authorised by the plant operator only.
- Please make sure that you have read and understood these operating instructions and that you know all applicable legislations regarding occupational safety and accident prevention prior to installation and putting the component into operation.
- The machine builder must carefully select the harmonised standards to be complied with as well as other technical specifications for the selection, mounting and integration of the components.
- The information contained in this operating instructions manual is provided without liability and is subject to technical modifications.
Explanation of the symbols used
- Information, hint, note: This symbol is used for identifying useful additional information.
- Caution: Failure to comply with this warning notice could lead to failures or malfunctions.
- Warning: Failure to comply with this warning notice could lead to physical injury and/or damage to the machine.
Appropriate use
- The Schmersal range of products is not intended for private consumers.
- The products described in these operating instructions are developed to execute safety-related functions as part of an entire plant or machine. It is the responsibility of the manufacturer of a machine or plant to ensure the correct functionality of the entire machine or plant.
- The safety switchgear must be exclusively used in accordance with the versions listed below or for the applications authorised by the manufacturer. Detailed information regarding the range of applications can be found in the chapter “Product description”.
General safety instructions
The user must observe the safety instructions in this operating instructions manual, the country specific installation standards as well as all prevailing safety regulations and accident prevention rules.
Further technical information can be found in the Schmersal catalogues or in the online catalogue on the Internet: products.schmersal.com.
Product description
Ordering code
Product type description: AZM161 (1)-(2)(3)K(4)-(5)/(6)(7)(8)
Special versions
- For special versions, which are not listed in the ordering code, these specifications apply accordingly, provided that they correspond to the standard version.
Purpose
The solenoid interlock has been designed to prevent in conjunction with the control part of a machine, movable safety guards from being opened before hazardous conditions have been eliminated.
- Safety locking devices with the working current principle may only be used in special cases after a strict assessment of the risk of accidents is used because if there is a power failure or the main switch is pressed, the protective device opens immediately can be.
- The safety switchgears are classified according to EN ISO 14119 as type 2 interlocking devices.
- The user must evaluate and design the safety chain in accordance with the relevant standards and the required safety level.
- The entire concept of the control system, in which the safety component is integrated, must be validated to the relevant standards.
Warning about misuse
In case of improper use or manipulation of the safety switchgear, personal hazards or damages to machinery or plant components cannot be excluded. There are no residual risks, provided that the safety instructions as well as the instructions regarding mounting, commissioning, operation and maintenance are observed.
Exclusion of liability
We shall accept no liability for damages and malfunctions resulting from defective mounting or failure to comply with the operating instructions manual. The manufacturer shall accept no liability for damages resulting from the use of unauthorised spare parts or accessories. For safety reasons, invasive work on the device as well as arbitrary repairs, conversions and modifications to the device are strictly forbidden, the manufacturer shall accept no liability for damages resulting from such invasive work, arbitrary repairs, conversions and/or modifications to the device.
Technical Data
Approvals – Standards
- Certificates: cULus
- CCC
General data
- Standards: BG-GS-ET-19
- EN ISO 14119
- EN IEC 60947-5-1
- Coding level according to EN ISO 14119: Low
- Working principle: electromechanical
- Enclosure material: Plastic, glass-fibre reinforced thermoplastic, self-extinguishing
- Gross weight: 458 g
General data – Features
- Power to lock: Yes
- Manual release: Yes
- Number of actuating directions: 3
- Number of auxiliary contacts: 2
- Number of safety contacts: 4
Safety classification
- Standards: EN ISO 13849-1
- Mission time: 20 Year(s)
Safety classification – Safety outputs
- B10D Normally-closed contact (NC): 2,000,000 Operations
- B10D Normally open contact (NO): 1,000,000 Operations
Mechanical data
- Mechanical life, minimum: 1,000,000 Operations
- Actuating play in direction of actuation: 5.5 mm
- Holding force FZh in accordance with EN ISO 14119: 2,000 N
- Latching force: 30 N
- Positive break travel: 10 mm
- Positive break force, minimum: 20 N
- Actuating speed, maximum: 2 m/s
Mechanical data – Connection technique
- Termination: Cage clamps
- Cable entry: 4 x M16 x 1,5
- Cable section, minimum: 1 x 0.25 mm²
- Cable section, maximum: 1 x 1.5 mm²
- Note (Cable section): All indications including the conductor ferrules.
Mechanical data – Dimensions
- Length of sensor: 30 mm
- Width of sensor: 130 mm
- Height of sensor: 90 mm
Ambient conditions
- Degree of protection: IP67
- Ambient temperature: -30 … +60 °C
- Storage and transport temperature, minimum: -25 °C
- Storage and transport temperature, maximum: +85 °C
Ambient conditions – Insulation values
- Rated insulation voltage Ui: 250 VAC
- Rated impulse withstand voltage Uimp: 4 kV
Electrical data
- Thermal test current: 6 A
- Rated control voltage: 24 VAC/DC
- Required rated short-circuit current: 1,000 A
- Electrical power consumption, maximum: 10 W
- Switching element: NO contact, NC contact
- Switching principle: Slow action
- Switching frequency: 1,000 /h
- Material of the contacts, electrical: Silver
Electrical data – Safety contacts
- Voltage, Utilisation category AC-15: 230 VAC
- Current, Utilisation category AC-15: 4 A
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 2.5 A
Electrical data – Auxiliary contacts
- Voltage, Utilisation category AC-15: 230 VAC
- Current, Utilisation category AC-15: 4 A
- Voltage, Utilisation category DC-13: 24 VDC
- Current, Utilisation category DC-13: 2.5 A
Other data
- Note (applications): sliding safety guard
- removable guard
- hinged safety guard
Note about the safety classification
Safety consideration of the locking function
Basically suitable up to Cat. 1 / PL c.
With 2-channel usage with fault exclusion mechanism (if a fault exclusion to
the 1-channel mechanics is authorised) and suitable logic applicable up to
Cat. 3 / PL d
- (Determined values can vary depending on the application-specific parameters as well as the load.)
- If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will be reduced due to the restricted error detection under certain circumstances
Safety consideration of the locking function
If the device is used as an interlock for personal safety, a safety classification of the guard locking function is required. When classifying the interlock function, a distinction must be made between monitoring of the interlock function (locking function) and controlling the unlocking function. The following safety classification of the unlocking function is based on the application of the principle of safety energy disconnection for the solenoid supply.
Warning: The safety consideration of the unlocking function is only valid for devices with a monitored locking function Quiescent current version (see type code).
A fault exclusion for the guard locking function can be assumed by an external safety energy disconnection. In this case, the guard locking function does not have an effect on the failure probability of the unlock function. The safety level of the unlock function is determined exclusively by the external safety power shutdown.
Warning
- Fault exclusion with regard to wiring routing must be observed.
- If for a certain application the power to unlock version of a solenoid interlock cannot be used, for this exception an interlock with power to lock can be used if additional safety measure need to be realised that have an equivalent safety level.
UL notice
- Use Type 4X (Indoor Use) and 12 connector fittings. Tightening torque rating: 4.4 lb in.
Mounting
General mounting instructions
Warning: Please observe the remarks of the standards EN ISO 12100, EN ISO 14119 and EN ISO 14120.
Three mounting holes are provided for fixing the enclosure. The solenoid interlock is double insulated. The use of an earth wire is not authorised. The solenoid interlock must not be used as an end stop. Any mounting position. The mounting position however must be chosen so that the ingress of dirt and soiling in the used opening is avoided. Unused actuator openings must be sealed with slot sealing plugs.
Warning: The actuator must be permanently fitted to the safety guards and protected against displacement by suitable measures (tamperproof screws, gluing, drilling of the screw heads).
Dimensions
- All measurements in mm.
Manual release
(for set-up, maintenance, etc.)
Manual release is realised by turning the triangular key by 180° (M5 triangular key available as accessory), so that the locking bolt is pulled into the unlocking position. Please ensure that jamming by external influence on the actuator is avoided. The normal locking function is only restored after the triangular key has been returned to its original position. After being put into operation, the manual release must be secured by installing the plastic cover, which is included in delivery.
- Triangular key TK-M5 (101100887) available as accessory.
Notentsperrung (Bestellindex -N)
(Fitting and actuation only from outside the hazardous area)
Warning: The emergency unlocking should only be used in an emergency. The safety interlock must be installed and/or protected in such a way that: an unintentional opening of the tumbler is prevented by the emergency release. The emergency unlocking must be clear must be marked with the message that it is only to be used in an emergency. The enclosed sticker can be used for this be used.
To activate the emergency release in case of an emergency, the orange lever must be turned to the stop in the direction marked by the arrow. In this position, the safety guard can be opened. The lever is latched and cannot be returned to its original position. To cancel the blocking condition, the central mounting screw must be loosened to such extent that the lever can be turned back into its original position. The screw must then be re-tightened.
Escape release
(Attachment and operation only within the danger area)
To release the escape release for version T, turn the orange lever in the direction of the arrow as far as it will go. The Escape release for the TD and TU versions is carried out by pressing the red push button. The protective device can be opened in this position. The locking position is activated by turning the lever back Opposite direction or retraction of the impact button is canceled. The protective device is in the unlocked position secured against accidental closing.
Electrical connection
General information for electrical connection
Warning
- The electrical connection may only be carried out by authorised personnel in a de-energised condition.
- If the risk analysis requires safely monitored locking, those with the symbol to integrate marked contacts into the safety circuit.
Appropriate cable glands with a suitable degree of protection are to be used. Remove the walls of the mounting holes by inserting the cable entry. All plastic residues must be removed from the switch compartment.
Tip: Piercing the bore walls with auxiliary tools (e.g. screwdrivers) can cause damage.
Settle length x of the conductor:
- on cage clamps (CC) of type s or f: 5 … 6 mm
- on screw terminals (SK): 7 mm
Contact Options
Contacts shown in a de-energised condition and with the actuator inserted
Legend
- Forced opening normally closed contact
- Monitoring of guard locking in accordance with EN ISO 14119
- Pressed
- Unactuated
AZM 161ST-../.. mit Stecker
AZM 161…-G with LED
Legende
- Door closed
- Solenoid
- Door locked
Integrated contact kit 12/12 G (with LED)
Legend
- Monitoring the interlock to EN ISO 14119
- Positive break NC contact
- actuated
- not actuated
GRA PRO CONT NO type unknown Normally-open contact
GRA PRO CONT NO type unknown Normally-closed contact
The 24 V are led internally to contacts 11 and 63. The corresponding signals of the LED display can also be tapped at terminals 12 or 64.
Integrated contact kit 12/03 G (with LED)
Legend
- Monitoring the interlock to EN ISO 14119
- Positive break NC contact
- actuated
- not actuated
GRA PRO CONT NO type unknown Normally-open contact
GRA PRO CONT NO type unknown Normally-closed contact
Legend
The 24 V are led internally to contacts 13 and 63. The corresponding signals of the LED display can also be tapped at terminals 14 or 64.
Quiescent current principle| | | |
---|---|---|---|---
System status| Magnet control
Quiescent current| gelb 1#| LED
rot 2#
| gelb 3#
open the door| 24 V (0 V)| out of| an| out of
---|---|---|---|---
Door closed, actuator inserted, not locked| 24 V| an| an| out of
Door closed, actuator inserted and locked| 0 V| an| out of| an
Quiescent current principle
Quiescent current principle
System status| Magnet control
working current
| LED
gelb 1#| rot 2#| gelb 3#
open the door| 0 V 24 V)| out of| out of| out of
Door closed, actuator inserted, not locked| 0 V| an| out of| out of
Door closed, actuator inserted and locked| 24 V| an| an| an
Set up and maintenance
The safety switching device must be tested for its safety function. When installed properly and used as intended, the safety switching device works maintenance-free. In regular We recommend a visual and functional check with the following steps:
- Check the safety switching device and actuator for tightness.
- Check the integrity of the line connections.
- Removing residual dirt.
Warning
- Adequate measures must be taken to ensure protection against tampering either to prevent tampering of the safety guard, for instance by means of replacement actuators.
- Damaged or defective components must be replaced.
Disassembly and disposal
Disassembly
- The safety switchgear must be disassembled in a de-energised condition only.
Disposal
- The safety switchgear must be disposed of in an appropriate manner in accordance with the national prescriptions and legislation.
Schmersal Ltd.
- Sparrowhawk Close, WR14 1GL Malvern
The details and data referred to have been carefully checked. Images may diverge from original. Further technical data can be found in the manual. Technical amendments and errors possible.