ACI Endpoint Security Group
Cisco ACI Endpoint Security Group (ESG) Design Guide
Specifications
Document Name | Cisco ACI Endpoint Security Group (ESG) Design Guide |
---|---|
Page Count | 49 |
Contents
-
Goals of this document
-
Prerequisites
-
Terminology
-
Introduction
-
Network-centric to
Application-centric Migration Story: Pseudo Co -
ESG Design Examples
-
Flexible Security Zones with
ESGs -
Detailed Design Examples
-
Cisco ACI Tenant Design Examples Using
ESGs -
FAQ
-
See Also
Goals of this document
This document aims to provide guidance on the design of Cisco
ACI Endpoint Security Group (ESG).
Prerequisites
This document assumes that the reader has a basic knowledge of
Cisco ACI technology. For more information about Cisco ACI, see the
Cisco ACI white papers
available at Cisco.com.
This document focuses on ESGs and does not cover detailed
contract configuration and design options. For more information
about contracts, see the Cisco ACI
Contract Guide.
For information about ESG configuration, see the Cisco APIC Security
Configuration
Guide, Release 6.0(x).
Terminology
This document uses the following terms:
-
TN: tenant
-
VRF: virtual routing and forwarding
-
BD: bridge domain
-
L3Out: Layer 3 Outside or external routed network
-
L3Out/External EPG: subnet-based EPG in L3Out
-
Border leaf switch: Cisco ACI leaf switch where an L3Out is
deployed -
VMware vCenter VMM domain: virtual machine manager domain on
Cisco ACI that maps to a virtual distributed switch (vDS) on VMware
vCenter -
Application-centric design and network-centric design: In a
typical network-centric design, a single EPG (security group) is
created per bridge domain. The EPG typically contains a single VLAN
ID, which is similar to a traditional network design. The network
building blocks are named in a manner that reflects the network
constructs, such as epg-vlan-10, epg-vlan-11, epgvlan-12.
Introduction
The introduction section provides an overview of the Cisco ACI
Endpoint Security Group (ESG) design guide.
Network-centric to Application-centric
Migration Story: Pseudo Co
This section explains the migration from a network-centric
design to an application-centric design using a Pseudo Co
approach.
ESG Design Examples
This section presents examples of ESG designs.
Flexible Security Zones with ESGs
This section discusses the concept of flexible security zones
using ESGs.
Detailed Design Examples
This section provides detailed examples of ESG designs.
Cisco ACI Tenant Design Examples Using
ESGs
This section showcases Cisco ACI tenant design examples that
utilize ESGs.
FAQ
Below are some frequently asked questions about Cisco ACI
Endpoint Security Group (ESG):
-
1. Q: What is the purpose of this document?
A: The purpose of this document is to provide guidance on the
design of Cisco ACI Endpoint Security Group (ESG).
-
1. Q: What are the prerequisites for this document?
A: This document assumes that the reader has a basic knowledge
of Cisco ACI technology. For more information about Cisco ACI, see
the Cisco ACI white papers available at Cisco.com.
-
1. Q: Does this document cover contract configuration and design
options?
A: No, this document focuses on ESGs and does not cover detailed
contract configuration and design options. For more information
about contracts, see the Cisco ACI Contract Guide.
-
1. Q: Where can I find information about ESG configuration?
A: For information about ESG configuration, see the Cisco APIC
Security Configuration Guide, Release 6.0(x).
See Also
For additional information, refer to related resources on
Cisco.com.
White paper Cisco public
Cisco ACI Endpoint Security Group (ESG) Design Guide
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 1 of 49
Contents
Goals of this document ……………………………………………………………………………………………………………4
Prerequisites …………………………………………………………………………………………………………………………..4
Terminology ……………………………………………………………………………………………………………………………. 4
Introduction …………………………………………………………………………………………………………………………….5
Network-centric to Application-centric Migration Story: Pseudo Co
………………………………………….5
Overview of Pseudo Company’s Cisco ACI Deployment ……………………………………………………………………..
5 Network Deployment ………………………………………………………………………………………………………………………… 6
Reference Application ………………………………………………………………………………………………………………………. 7
Endpoint Group vs Endpoint Security Group …………………………………………………………………………………….. 9
Design BlueprintSingle ESG per Application …………………………………………………………………………………..
11 Migration Steps ………………………………………………………………………………………………………………………………. 12
Step 1: Implement a single ESG for open communication between subnets (EPG
selectors) ……………………. 13 Step 2: Implement a single ESG for all endpoints of a
single application (tag selectors)……………………………. 15 Step 3: Communication
between applications (contract between ESGs) ………………………………………………… 20 Step 4:
Enforce additional application security ……………………………………………………………………………………. 21
ESG Design Examples……………………………………………………………………………………………………………24
Flexible Security Zones with ESGs ………………………………………………………………………………………………….. 24
Detailed Design Examples ………………………………………………………………………………………………………………. 26
Example 1: A security zone per VRF instance as a default zone (EPG selectors)
……………………………………. 27 Example 2: A security zone per set of subnets/VLANs (EPG
Selectors) …………………………………………………. 28 Example 3: Tag Selectors with VMM
integration …………………………………………………………………………………. 29 Example 4: Tag selectors
without VMM integration for VM endpoints using the MAC address …………………… 29
Example 5: Tag selectors without VMM integration for VM endpoints using the IP
address ………………………. 31 Example 6: Tag selectors for bare metal endpoints using
the MAC address……………………………………………. 32 Example 7: Tag selectors for bare metal
endpoints using the IP address ……………………………………………….. 33 Example 8: Tag
selectors with intermediary switches…………………………………………………………………………… 34 Example
9: IP subnet selectors ………………………………………………………………………………………………………… 35 Example 10:
ESG as a container of an application using tag selectors with a default
security zone using EPG selectors
……………………………………………………………………………………………………………………………………….. 36 Example 11: Multiple
security zones using EPG selectors with a quarantine ESG using tag
selectors………… 37 Example 12: ESG with Layer 2 multicast
……………………………………………………………………………………………. 38 Example 13: EPG Selectors and IP-based
Selectors Without a VMM Domain ………………………………………… 39
Appendix: Cisco ACI Tenant Design Examples Using ESGs ……………………………………………………40
Example 1: All in a user tenant ………………………………………………………………………………………………………… 42
Example 2: VRF instance/bridge domains/EPGs (VLANs) in tenant common while
ESGs in user tenants
………………………………………………………………………………………………………………………………………………………. 42 Example 3: VRF
instance/bridge domains are in tenant common while EPGs (VLANs) and ESGs are
in user tenants……………………………………………………………………………………………………………………………………. 43
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 2 of 49
Example 4: Shared services in the same VRF instance from tenant common
…………………………………….. 43 Example 5 Shared services in a different VRF
instance…………………………………………………………………….. 44
FAQ ………………………………………………………………………………………………………………………………………. 46 See Also
………………………………………………………………………………………………………………………………..49
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 3 of 49
Goals of this document
This document describes Cisco® Application Centric Infrastructure (Cisco ACI®)
Endpoint Security Group (ESG) use cases and deployment considerations.
Prerequisites
This document assumes that the reader has a basic knowledge of Cisco ACI
technology. For more information about Cisco ACI, see the Cisco ACI white
papers available at Cisco.com.
This document focuses on ESGs and does not cover detailed contract
configuration and design options. For more information about contracts, see
the Cisco ACI Contract Guide.
For information about ESG configuration, see the Cisco APIC Security
Configuration Guide, Release 6.0(x).
Terminology
This document uses the following terms:
TN: tenant
VRF: virtual routing and forwarding
BD: bridge domain
EPG: endpoint group a collection of endpoints attached to one or more VLANs
within a BD ESG: endpoint security group a collection of endpoints within a
VRF instance EP: endpoint residing in a Cisco ACI fabric
L3Out: Layer 3 Outside or external routed network
L3Out/External EPG: subnet-based EPG in L3Out
Border leaf switch: Cisco ACI leaf switch where an L3Out is deployed
VMware vCenter VMM domain: virtual machine manager domain on Cisco ACI that
maps to a virtual distributed switch (vDS) on VMware vCenter
Application-centric design and network-centric design:
In a typical network-centric design, a single EPG (security group) is created
per bridge domain. The EPG
typically contains a single VLAN ID, which is similar to a traditional network
design. The network building blocks are named in a manner that reflects the
network constructs, such as “epg-vlan-10, epg-vlan-11, epgvlan-12”.
In an application-centric design, one or more EPGs/ESGs are created on the
same bridge domain. The
network building blocks are named in a way that reflects the application, such
as “epg-web, epg-app, epgdb”.
Figure 1 shows the icons used throughout this document. The object handles
depict the following functions: C: Contract consumer CCI: Consumed contract
interface I: Intra EPG/ESG contract P: Contract provider
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 4 of 49
Figure 1. Cisco ACI Icons
Introduction
The document covers features up to Cisco ACI release 6.0(2). The document is
divided into several sections:
Network Centric to Application Centric Migration Story: Pseudo Co explains one
example of adopting ESGs in a Cisco ACI fabric for users new to ESGs.
ESG Design Examples explains more ESG design examples for users familiar with
ESGs. Appendix explains comprehensive Cisco ACI multi-tenant design examples.
Network-centric to Application-centric Migration Story: Pseudo Co
This section covers an EPG to ESG migration story using Pseudo Co a
(fictitious) company that has historically been using Cisco ACI in a network-
centric design with a single EPG per subnet.
See the ESG Design Examples section for other design options.
Overview of Pseudo Company’s Cisco ACI Deployment
Pseudo Co has configured several Cisco ACI tenants with numerous virtual
machine endpoints on ESXi hosts that are directly attached to the Cisco ACI
fabric.
The following figure provides a high-level overview of Pseudo Co’s Cisco ACI
fabric and the attached devices:
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 5 of 49
Figure 2. Pseudo Co’s Cisco ACI Fabric: Physical Topology
Network Deployment
Pseudo Co has deployed its Cisco ACI fabric in what is commonly described as a
network-centric design where there is a 1:1 mapping of bridge domains to EPGs.
As part of the network implementation, Pseudo Co chose to implement a VMM
domain to simplify the management of VLANs between the Cisco ACI fabric and
the ESXi hosts. The Cisco APIC VMM domain dynamically allocates VLANs to the
vDS port groups from a VLAN pool on Cisco APIC. Due to the dynamic VLAN
allocation, it is often practical to implement a naming format where the
BD_name = EPG_name. However, for the purposes of this document and to
illustrate the function of the bridge domains and EPGs, this document uses the
subnet CIDR for the bridge domain name and the VLAN ID for the EPG name:
Tenant: demo VRF: vrf-01 Bridge domains: 10.0.1.0_24 10.0.7.0_24 EPGs:
VLAN10 VLAN70 EPs: Distributed across the different network segments The
following figure represents one of Pseudo Co’s tenants:
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 6 of 49
Figure 3. Pseudo Co’s Cisco ACI Fabric: Network Segments
Reference Application
For this design guide, we will show how Pseudo Co easily converted its Cisco
ACI fabric from a network-centric design to an application-centric design. The
diagram below illustrates a multi-tier reference application (onlineboutique)
that will be used throughout this design guide.
Note: The reference application was inspired from this demo application on
GitHub.
Consumer traffic to the online-boutique application uses the frontend service
on ports 80/8080 as detailed in the accompanying table. The arrows between the
application tiers detail the expected traffic flows, which is from the
source/consumer to the target/provider.
Figure 4. Pseudo Co’s Cisco ACI Fabric: A Reference Application
The diagram below illustrates how the online boutique application has been
deployed across the different network segments (subnets) within the “demo”
tenant. Note that several application services, such as frontend, payment, and
cart, span different subnets. Spreading endpoints across different subnets
within Pseudo Co occurred because
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 7 of 49
of exponential growth in the number of endpoints required for a given application tier. Application endpoints have crossed subnet boundaries due to IP address exhaustion within a given subnet.
Figure 5. Pseudo Co’s Cisco ACI Fabric: A Reference Application Across Network
Segments
Applications such as the online boutique application that are hosted on Pseudo
Co’s network-centric Cisco ACI fabric require open communication between the
different application tiers to enable the application to function correctly.
There are several different configuration options available to enable open
communication amongst many/all EPGs on a Cisco ACI fabric:
Contract with vzAny: vzAny represents all EPGs, ESGs and external EPGs on a
VRF instance. Providing and consuming an open “permit-any” contract on vzAny
allows open communication between all endpoints on a VRF instance.
Preferred Groups Assigning multiple EPGs to a Preferred Group allows open
communication between the EPGs in the Preferred Group, with the restriction
that there can only be one Preferred Group per VRF instance.
Disable security We do not recommend this option because configuring the VRF
instance to “unenforced” mode converts the VRF instance to “permit only,”
allowing open communication between all endpoints in the VRF instance.
Disabling security implicitly disables security contracts and advanced
functionality such as service graphs.
In addition to the above options, starting from Cisco ACI release 5.2(1g), you
can use an ESG with EPG selectors to create a security group that aggregates
several EPGs. Communication within a given ESG (intra-ESG communication) is
permitted by default. The use case for EPG to ESG mapping is covered in detail
later in this section.
Pseudo Co has currently enabled open communication within a VRF instance
through the use of the vzAny, which provides and consumes the “default”
contract from the “common” tenant as illustrated in the following figure:
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 8 of 49
Figure 6. Pseudo Co’s Cisco ACI Fabric: vzAny-to-vzAny contract to permit all
inter-EPG communications
Endpoint Group vs Endpoint Security Group
It is important to compare the functionality and design considerations of
endpoint groups vs endpoint security groups. The basic building blocks of
Cisco ACI (as detailed in the Figure below) dictate that:
VRF instance: Can only exist in a single tenant. Bridge domain: Can only be
mapped to a single VRF instance and can provide routing for one or more
subnets (Secondary IP addresses). EPG: Defines a security group boundary
within a bridge domain. Admission to the EPG is defined by static
path bindings on leaf switches (interface/VLAN) or VMM binding. ESG: Defines a
security group boundary within a VRF instance. Admission to the ESG is defined
by one or
more of the following methods:
EPG SelectorsOne or more EPGs can be mapped to an ESG Tag SelectorsEndpoints
can be mapped to an ESG based on:
o MAC address o IP address o VM name o VM Tag
IP SelectorsIP addresses can be mapped to an ESG
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 9 of 49
Figure 7. Security considerations of endpoint groups vs endpoint security
groups
ESG mapping is implemented based on a hierarchical decision criterion for
switched and routed traffic as shown in the tables in the Selector Precedence
FAQ. Endpoints that match an EPG selector have a lower match priority than
endpoints that match a tag selector. The ESG decision selection allows network
administrators to move endpoints dynamically between different ESGs without
changing the network backing. For example, all endpoints contained in an EPG
can be mapped to ESG-A using an EPG selector. Specific endpoints can then be
mapped to ESG-B using higher priority tag selectors.
In summary, we recommend that you use ESGs to provide Cisco ACI segmentation
due to their ability to support flexible security design such as:
A security group defined by an ESG is not limited to endpoint classification
within a single bridge domain. Endpoints can change the security group (the
ESG) without changing the underlying network configuration,
such as the VLAN ID, nor changing the interfaces through the EPGs. Full
details of ESG classification options are covered in the ESG Design Examples
section.
While the use of contracts is equally applicable to both EPGs and ESGs, ESGs
provide an enhanced security option as they allow the grouping of endpoints
across different bridge domains within a VRF instance (as shown above).
Conversely, an EPG is tied to a single bridge domain within a VRF instance
therefore it is not possible to select endpoints across different bridge
domains. The bridge domain-to-EPG mapping can present a barrier when migrating
from a network-centric design to an application-centric design if application
endpoints span across different EPGs and bridge domains (Figure 5). ESGs
remove this restriction because they operate across a VRF instance.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 10 of 49
Design BlueprintSingle ESG per Application
The network infrastructure team at Pseudo Co chose to migrate from their
current network-centric design to an application-centric design by creating
one security zone per application. The initial design blueprint places all
endpoints of a given application into a single ESG. After an application has
been mapped to an ESG, the team will evaluate and adjust ESG membership as
required. For example, the team might move certain shared services, such as
databases, to a dedicated ESG. Moving endpoints between ESGs can be achieved
seamlessly without changing the network backing by simply adjusting the ESG
selection criteria.
Figure 8. Pseudo Co’s Cisco ACI Fabric: one ESG per application (new design)
The implementation of a single ESG per application provides network
administrators with a clear view of where applications are running on the
Cisco ACI fabric, which in turn provides the following key benefits:
Improved application visibility: Creation of a single ESG for all application
endpoints allows network administrators to understand exactly where the
application endpoints are attached to the network. The details included are as
follows:
MAC/IP address Interface VLAN encapsulation ID EPG Policy Tag VM name
(requires read/write VMM integration) Hosting server (requires read/write VMM
integration) Reporting controller (requires read/write VMM integration) VM Tag
(requires read/write VMM integration)
Security tied to applications rather than network segments: ESGs allow network
and security administrators to implement security based on applications rather
than on network segments or IP addresses. This allows for simpler network
designs as there is no longer a requirement to insert security devices into
the routing
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 11 of 49
path. Instead, Layer 4 to Layer 7 services devices can be dynamically inserted
(using service graphs) within an application or between applications.
Increased security through tightening of contracts: Cisco ACI contracts
provide stateless Layer 4
hardware-based ACL security controls between applications using
provided/consumed contracts, or within a given application using intra-ESG
contracts. After an application has been identified and its endpoints mapped
into an ESG, you can increase the security of the application by restricting
the (filter) ports referenced in the provided contract or by controlling the
direction in which TCP connections are established. That is, connections can
only be established from consumer to provider.
Isolated application groups: ESGs can be set to “enforced” mode (intra-ESG
isolation), which blocks all
traffic within the ESG, thus isolating application endpoints. Optionally, you
can add an intra-ESG contract to the ESG to permit communication on specific
ports within the ESG.
Intelligent service insertion: Layer 4 to Layer 7 services can be dynamically
inserted either in front of an
application ESG, or within an ESG. For example, an intra-ESG contract with
Service Graph can be added to an isolated ESG to redirect all intra endpoint
traffic through a Next Generation Firewalls/IPS.
Application dependency mapping: network administrators are able to leverage an
intra-ESG contract to forward all traffic within an ESG, via a service graph,
to a Layer 4 to Layer 7 services device such as a firewall. Configuring the
firewall with a “permit-any | log” rule allows the firewall to generate syslog
messages for all inter-endpoint communication within the ESG. Additionally,
traffic destined to the ESG can also be redirected, using a service graph, to
a Layer 4 to Layer 7 services device to log all traffic to the application.
Note: You can also enable Cisco ACI contract logging. However, the logging is
limited to 500pps for denied traffic and 300pps for permitted traffic.
Improved auditing capabilities: The ability to view application endpoints on
the Cisco ACI fabric provides network administrators with a streamlined
approach to auditing applications, their associated security rules, and Layer
4 to Layer 7 service integration.
Improved troubleshooting: The ability to view an application on the Cisco ACI
fabric allows network administrators to view the health of individual
applications and thus quickly and simply correlate any application performance
issues with potential network errors such as packet drops.
The following graphic details the operational information available in Cisco
APIC for a given ESG:
Figure 9. ESG visibility (Operational tab)
Migration Steps
Pseudo Co identified the following steps that are required to convert from a
network-centric design to an application-centric design:
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 12 of 49
1. Implement EPG-to-ESG mapping using an EPG selector to allow open
communication between EPGs on a given VRF instance. This removes the
requirement of the vzAny contract, allowing for more flexible security options
in the future.
2. Implement a single ESG for the online boutique virtual machine endpoints
using VM tag identifiers by way of a tag selector.
3. Allow communication using contracts between the online boutique
application ESG and other ESGs on the network.
4. Enforce additional security by selecting the protocols and ports that are
open to the online boutique application ESG.
As detailed previously, Pseudo Co implemented a simple “permit-any” contract
that is provided and consumed on vzAny. During the migration from the network-
centric design to the application-centric design, do not change the open
security control that is provided by vzAny. Failure to maintain the current
open security controls could result in application connectivity issues. At a
later stage, Pseduo Co can decide whether the open application security rules
defined in the contract are sufficient from a security standpoint. If there is
a requirement for tighter security, this can be achieved by only specifying
the protocols/ports that are required by the application.
Step 1: Implement a single ESG for open communication between subnets (EPG
selectors) Pseudo Co implemented their Cisco ACI network in a typical network-
centric design with a 1:1 mapping between bridge domains and EPGs, as shown in
Figure 3. Each bridge domain is configured with a single subnet/default
gateway for endpoints and is mapped to a single EPG that provides the VLAN
backing. The classification of endpoints into an EPG is performed by matching
traffic on an incoming leaf/interface/VLAN.
As part of the network-centric to application-centric migration Pseudo Co will
implement a single ESG that will provide open communication between all
subnets/EPGs. Refer to the following diagram:
Figure 10. Pseudo Co’s Cisco ACI Fabric: single security zone for multiple
EPGs
The mapping of multiple EPGs to a single ESG using an EPG selector is an
alternative solution to allow communication amongst multiple EPGs on a Cisco
ACI fabric. EPG-to-ESG mapping is a more flexible solution when compared to
using preferred groups. Cisco ACI supports multiple ESGs per VRF instance,
whereas there can only be one preferred group per VRF instance. Additionally,
you cannot apply a contract to the preferred group itself to allow
communication from all EPG members of the preferred group to another EPG
outside of the preferred group, whereas you can apply a contract directly to
ESGs.
The mapping of multiple EPGs to ESGs is also considered to be a better
security design compared to vzAny, as it allows network administrators to
select specific EPGs to map rather than using vzAny, which implicitly selects
all EPGs, ESGs, and external EPGs within a VRF instance.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 13 of 49
The network administrator should be aware that mapping one or more EPGs to an
ESG triggers a change in the class ID of the EPGs. Prior to mapping the EPGs
to an ESG, each EPG on a VRF instance will have a unique class ID. When
mapping EPGs to an ESG, the class ID of each mapped EPG is rewritten to that
of the ESG. Because all endpoints are now classified to an ESG with the same
class ID, all traffic is implicitly permitted without a contract. Note: The
reclassification of class IDs causes a momentary drop in network traffic. We
recommend that you perform the EPG-to-ESG mapping during a change window.
Figure 11. Pseudo Co’s Cisco ACI Fabric: EPG to ESG migration (class ID
change)
EPG selectors are also useful for more advanced migration scenarios, such as a
Cisco ACI fabric that is deployed already with contracts between EPGs, as
opposed to vzAny allowing open communication within the VRF instance. In such
a scenario, you must keep those contracts and security groupings while
migrating to ESGs from EPGs. Refer to “Endpoint Security Groups > ESG
Migration Strategy” in Cisco APIC Security Configuration Guide for detailed
steps. Configure EPG selectors The figure below shows the configuration. The
location is at Tenant > Application Profiles > Application_Profile_name >
Endpoint Security Groups > ESG_name > Selectors > EPG Selectors.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 14 of 49
Figure 12. EPG selector
Note: Any endpoints in the same VRF instance can belong to the same ESG.
However, when configuring ESG with EPG selectors, the EPGs must belong to the
same tenant as the ESG.
Step 2: Implement a single ESG for all endpoints of a single application (tag
selectors) The application owners at Pseudo Co have assigned tags to their
application virtual machines in VMware vCenter to allow for simple
identification of the workloads that make up a given application. Cisco ACI
can leverage the assigned virtual machine tags by collecting them from VMware
vCenter and then mapping them to ESG tag selectors on Cisco APIC.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 15 of 49
Figure 13. Virtual machine tag assignment
The matching of virtual machine tags in VMware vCenter to Cisco ACI tags in
Cisco APIC allows network administrators and application owners to move
virtual machines seamlessly and dynamically from their original “allnetwork-
segments” ESG (as shown in Figure 10. ) into the correct “online-boutique:all-
services” application ESG. In this step, it is focused on a single
application–Online Boutique–but the ability to create multiple ESGs within a
VRF instance allows network administrators to contain multiple applications in
the same VRF instance with one (or more) ESG per application as shown in
Figure 20.
Note: Tag selectors with Virtual Machine tags have a higher priority than EPG
selectors. This priority allows the dynamic movement of endpoints between
different ESGs on a VRF instance. Full details of selector precedence can be
found in the selector precedence order in the FAQ.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 16 of 49
Figure 14. All application endpoints in a single ESG
Classification based on tag selectors The figure below shows the configuration
object for creating tag selectors.
The location is at Tenant > Application Profiles > Application_Profile_name >
Endpoint Security Groups > ESG_name > Selectors > Tag Selectors.
The Cisco ACI tag selectors (below) match the virtual machine tags on VMware
vCenter where the Function of a virtual machine Equals a specific Tag Value.
For example: Function = tn-demo-online-boutique-currency-service this
key/value pair matches any virtual machines which provide the “currency
service” as part of the “online-boutique” application in tenant “demo”.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 17 of 49
Figure 15. Pseudo Co’s Cisco ACI Fabric: one ESG for set of EPGs with VM tags
Your configuration must meet the following prerequisites before you can use VM
tags for ESG mapping: Enable tag collection on the VMM domain. Enable micro-
segmentation on the EPGs with the VMM domain.
Prerequisite: enable tag collection on the VMM domain If you use an ESG with
VMware tag selector, you must put a check in the “Enable Tag Collection” box
for the VMM domain. The figure below shows the configuration. The location is
at Virtual Networking > VMware > Domain name > General.
Figure 16. Prerequisite: “Enable Tag Collection” on the VMM domain
Prerequisite: enable micro segmentation on the EPGs with a VMM domain If you
use an ESG with a VMware vDS VMM domain, you must put a check in the “Allow
Micro-Segmentation” box on the EPG associated to the VMM domain to allow
endpoints to be selected by the VM tag or VM name. If the EPG is mapped
directly to the ESG (EPG selector), there is no requirement to configure
“Allow MicroSegmentation” because the EPG to ESG mapping is based on the EPG
VLANs.
Putting a check in the “Allow Micro-Segmentation” box configures a PVLAN
(Private VLAN) on the port group for the EPG. When reconfiguring an existing
VMM mapped EPG, the vDS is dynamically updated with a new PVLAN pair from the
dynamic VLAN pool. If Layer 2 multicast or flooding traffic is required, see
the section Example 12: ESG with L2 multicast.
Note: The “Allow Micro-Segmentation” box is not checked by default.
The figure below shows the configuration. The location is at Tenant >
Application Profiles > Application_Profile_name > Application EPGs > EPG_name
Domains.
For network deployments where there are intermediary switches (such as blade switches) between the Cisco ACI leaf switch and the ESXi host, the network administrator must statically define the PVLAN pairs that are to be used
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 18 of 49
on the VMM domain. The allocated VLANs must also be configured on the intermediary switch. While PVLAN pairs can be dynamically allocated on Cisco ACI, this may make it difficult for the administrator to configure the same set of PVLAN pairs manually on the intermediary switches. When statically defining the PVLAN pairs on Cisco ACI, the VLAN IDs should be allocated from a static VLAN range in the VLAN pool associated to the VMM domain.
Figure 17. Prerequisite: “Allow Micro-Segmentation” on the EPGs for directly
attached hosts static VLAN allocation is recommended when intermediary
switches are deployed
Configure Tag selectors The next step is to configure an ESG with a tag
selector to define which virtual machine endpoints should belong to the ESG.
The figure below shows the configuration. The location is at Tenant >
Application Profiles > Application_Profile_name > Endpoint Security Groups >
ESG_name > Selectors > Tag Selectors.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 19 of 49
Figure 18. VM tag selector
The following VMM information is supported: VM name (Tag key: __vmm::vmname,
Tag value:
In the example below, the Cisco APIC pulled the VM names (vmm::vmname) and
vSphere VM Tags from VMware vCenter. The Cisco APIC then assigned them to the
MAC address of the VM. The Cisco APIC has then matched the vSphere tags to the
Cisco APIC tag selectors. The bridge domain and VRF instance are identified
from the Cisco APIC endpoint mapping database. Note: Cisco APIC reads tags
from VMware vCenter once per 5-minute time window
The location in the Cisco APIC GUI is at Tenant > Policies > Endpoint Tags >
Endpoint MAC.
Figure 19. Policy Tags: Endpoint MAC
Step 3: Communication between applications (contract between ESGs) After the
endpoints of an application have been grouped into a single ESG, you must
provide access to the application (using contracts) from the wider network.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 20 of 49
In the example below, the online boutique application (online-boutique:all-
services ESG) provides a service (contract provider) which is consumed by the
application-monitoring:all-services ESG, the all-network-segments ESG, and the
remote-users external EPG from any remote subnet using the “permit-to-tn-demo-
online-boutique” contract.
The online-boutique:all-services ESG also consumes services such as Active
Directory, DNS, NTP, and software updates from the core-services:all-services
ESG.
Figure 20. Pseudo Co’s Cisco ACI Fabric: contract between ESGs
The arrows indicate the expected traffic flow, which is from the consumer to the provider.
Table 1. Contract relationship
Consumer ESGs
Contract Name
Provider ESGs
epg-matched-esg:all-network-segments
permit-tn-demo-online-boutique
online-boutique:all-services
application-monitoring:all-services
permit-tn-demo-online-boutique
online-boutique:all-services
extEPG:remote-users
permit-tn-demo-online-boutique
online-boutique:all-services
online-boutique:all-services application-monitoring:all-services
permit-tn-demo-core-services permit-tn-demo-core-services
core-services:all-services core-services:all-services
By configuring contracts between ESGs, only specific inter-ESG traffic is allowed. In addition, intra-ESG traffic is permitted by default. Instead of using a “default” permit-any filter, you can use more granular filters to allow specific types of traffic only for the inter-ESG traffic. For more information, see the ACI Contract Guide.
Step 4: Enforce additional application security
Intra-ESG isolation or contract While communication within an ESG is “permit- all” by default, additional security enforcement can be applied to the ESG to either “deny-all” traffic or “permit-specific-ports” within the ESG. To “deny- all” traffic, the ESG simply needs to have Intra-ESG Isolation set to enforced. To “permit-specific-ports” an intra-ESG contract needs to be added to the ESG. The intra-ESG contract could leverage a service graph to redirect traffic to a Layer 4 to Layer 7 services device such as a next generation firewall/IPS.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 21 of 49
In the example below, all endpoints in the online-boutique:all-services ESG are able to communicate freely. However, communication between the endpoints in the application-monitoring:all-services ESG is blocked as there is no requirement for inter-endpoint communication between the monitoring servers.
Figure 21. Pseudo Co’s Cisco ACI Fabric: intra-ESG isolation
The figure below shows intra-ESG isolation configuration. By default, intra-
ESG isolation is unenforced. The location is at Tenant > Application Profiles
Application_Profile_name > Endpoint Security Groups > ESG_name > Policy > General.
Figure 22. Pseudo Co’s Cisco ACI Fabric: intra-ESG isolation (enforced)
The figure below shows the intra-ESG contract configuration. The location is
at Tenant > Application Profiles > Application_Profile_name > Endpoint
Security Groups > ESG_name > Contracts > Add Intra-ESG Contract.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 22 of 49
Figure 23. Pseudo Co’s Cisco ACI Fabric: intra-ESG contract
Service Graph with PBR for Layer 4 to Layer 7 service insertion In addition to
the hardware-based permit/deny security enforcement using contracts with
stateless filtering, you can also dynamically insert stateful Layer 4 to Layer
7 devices such as firewalls and IPS (Intrusion Prevention Systems) into the
data path, either between ESGs or within ESGs (intra-ESG).
Figure 24. Pseudo Co’s Cisco ACI Fabric: Service Graph with PBR for firewall
insertion
For more information, see the ACI Contract Guide and Cisco ACI Policy-Based
Redirect Service Graph Design White Paper.
You must consider the Layer 4 to Layer 7 services device configuration when
redirecting traffic to the Layer 4 to Layer 7 services device. In the example
below, the flexible nature of ESGs allows the logical grouping of endpoints
from different subnets into discrete security zones. The configuration on the
firewall needs to reflect the IP address information derived from the ESGs.
This can be achieved by the firewall management platform pulling ESG
membership information.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 23 of 49
Figure 25. Endpoint membership information
The following applications and plug-ins are currently available for ESG
membership advertisement:
Cisco Adaptive Security Appliance (ASA) and Cisco Firepower Threat Defense
(FTD): ACI Endpoint Update Palo Alto Networks Panorama: Panorama Plugin for
Cisco ACI (Roadmap) If your Layer 4 to Layer 7 services device is different
from those listed above, endpoints to ESG membership information can be
retrieved using the Cisco APIC API. Thus, a simple script or application could
be used to retrieve the information and create equivalent security groups on
the Layer 4 to Layer 7 services device. For more information, see the FAQ.
ESG Design Examples
This chapter shows ESG use cases with many individual examples so that you can
directly jump to the use cases of interest (Table 2 and Table 3). If you are
new to ESGs or prefer a walkthrough of a scenario-based example, read the
chapter Network Centric to Application Centric Migration Story: Pseudo Co.
The ESGs present network administrators with many flexible design options for
segmenting physical or virtual workloads as detailed in the Detailed Design
Examples section. In addition to the option of creating fine-grained,
application-focused ESGs, Cisco ACI also allows network administrators to use
ESGs to aggregate multiple EPGs (VLANs) or create subnet-based security zones
within a VRF instance. Both options are equally flexible and you can use them
concurrently. Indeed, a powerful benefit of ESGs is the ability to move
endpoints dynamically from a zone-based security environment to an
application-based security environment without modifying the network backing.
Flexible Security Zones with ESGs
1. Single security zone per VRF instance: Map all EPGs within a VRF instance
to a single ESG as a default security zone for all endpoints.
2. Multiple Security zones per VRF instance: Map a subset of EPGs to an ESG
security zone. Create one or more ESG security zones per VRF instance.
3. Security zones per application: Map individual endpoints to an ESG via Tag
selectors across any subnet or VLAN on a given VRF instance.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 24 of 49
We recommend that you use options 1 or 2 as the base configuration so that all
endpoints are covered by an ESG in one way or the other, and then use option 3
for more granular segmentation groups. The following diagrams depict each
option when deployed individually. To combine different types of selectors,
refer to the selector precedence order in the FAQ. The following figure is
explained in more detail in Example 1: A security zone per VRF as a default
zone (EPG selectors) along with Figure 29.
Figure 26. Default security zone for all subnets/VLANs in the same VRF
instance
The following figure is explained in more detail in Example 2: A security zone
per set of subnets/VLANs (EPG Selectors) along with Figure 30.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 25 of 49
Figure 27. Security zones per set of EPGs (subnets/VLANs)
The figure below shows application endpoints selected by VMware vCenter/Cisco
APIC tags. Additional examples, such as Figure 31. , are shown in detail in
the next section.
Figure 28. Security zones per application
Detailed Design Examples
The table below summarizes several different ESG examples such that the reader
can understand how the different selector options can be used. You can use all
options simultaneously as desired and as shown in the table below.
Note: If you require Layer 2 multicast within the ESGs, the selectors should
be EPG selectors or tag selectors with MAC addresses. See Example 12 for more
information.
Table 2.
Examples of ESG deployment options single selector criteria
Category
Example
Description
Base Security with EPG Example 1: A security zone per Map all EPGs to a single ESG as a default security zone of a given
selectors
VRF instance as a default zone VRF instance.
(EPG selectors)
Example 2: A security zone per Map a subset of EPGs to an ESG security zone. Create one of more
set of subnets/VLANs (EPG Selectors)
ESG security zones per VRF instance.
(Multiple security zones per VRF instance)
Granular Security with Tag selectors
Example 3: Tag selectors with VMware VM tags are pulled from VMware vCenter via VMM
VMM integration
integration.
Example 4: Tag selectors without Cisco ACI administrators assign a Cisco APIC policy tag to MAC
Map individual endpoints VMM integration for VM
addresses of each virtual machine endpoint on Cisco APIC. No tag
across any subnets or endpoints using the MAC address sync with VMware vCenter.
VLANs to an ESG as a Example 5: Tag selectors without Cisco ACI administrators assign a Cisco APIC policy tag to IP
granular security group via VMM integration for VM
addresses of each virtual machine endpoint on Cisco APIC. No tag
VMware tags or Cisco endpoints using the IP address sync with VMware vCenter.
APIC policy tags
Example 6: Tag selectors for bare Cisco ACI administrators assign a Cisco APIC policy tag to MAC
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 26 of 49
metal endpoints using the MAC addresses of each bare metal endpoint on Cisco
APIC. address
Example 7: Tag selectors for bare Cisco ACI administrators assign a Cisco APIC
policy tag to IP metal endpoints using the IP addresses of each bare metal
endpoint on Cisco APIC. address
Example 8: Tag selectors with PVLAN is required on the intermediary non-Cisco
ACI switches. intermediary switches
Granular Security with IP Example 9: IP subnet selectors Assign IP addresses
or subnets directly to an ESG. Subnet selectors
The following table shows additional examples with multiple selectors used in
conjunction with each other:
Table 3.
Examples of ESG deployment options multiple selector criteria
Example
Description
Example 10: ESG as a container of application endpoints via Tag selectors with a default security zone via EPG selectors.
An example from chapter Network Centric to Application Centric Migration Story: Pseudo Co.
Example 11: Multiple security zones via Assign a tag to endpoints that are malfunctioning or vulnerable to isolate them from EPG selectors with a quarantine ESG via each security zone. Tag selectors.
Example 12: ESG with Layer 2 multicast . An example of how to design ESGs for situations where there is L2 multicast/flood traffic.
Example 13: EPG selectors and IP-based An example of how to configure proxy ARP for IP-based selectors when the EPGs are
selectors
matched to an ESG using EPG selectors.
Example 1: A security zone per VRF instance as a default zone (EPG selectors)
Many customers start their Cisco ACI deployments with a permit-all contract
provided and consumed on vzAny, or alternatively including all EPGs in a
preferred group to allow all communication within a VRF instance, with the aim
of gradually implementing more security later. An ESG can simplify this
approach by allowing network administrators to have a simple, flexible
starting point with a better extensibility for the future. By mapping all EPGs
in the VRF instance to a single ESG using EPG selectors, the ESG acts as a
default security zone. After you create this base security zone, you can
explicitly select endpoints to be classified to other more granular ESGs.
An ESG as a default security zone acts as a fallback for all endpoints in the
VRF instance by mapping all EPGs in the VRF instance to an ESG using EPG
selectors. All endpoints shown below can talk to each other as they belong to
the same ESG. A network administrator could implement an intra-ESG contract
with a service graph PBR such that (by default) all intra-ESG traffic is
redirected to a firewall. Alternatively, you can configure the default
security zone ESG with isolation enforced, preventing intra-ESG communication
until the workloads are moved to their correct application ESG with their
associated contracts.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 27 of 49
Figure 29. Design Example: default security zone for a given VRF instance
Example 2: A security zone per set of subnets/VLANs (EPG Selectors) Instead of
creating a single default security zone for a given VRF instance as shown in
the previous example, an ESG with EPG selectors can easily create multiple
security zones within the same VRF instance without each zone being limited to
one bridge domain. In this use case, each ESG represents one enclave, such as
organization or development group, based on an organization’s security
requirements. This allows communications within each enclave without
additional configuration while, by default, blocking cross-enclave
communications. Each enclave likely contains multiple applications that
consist of a set of endpoints across bridge domains. You cannot achieve this
design using EPGs, as the endpoints are located across multiple bridge
domains.
In this example, each enclave is assigned a set of dedicated VLANs/subnets,
such as VLAN 10 and 20 for ESG subnet-group-01 and VLAN 30 and 40 for ESG
subnet-group-02. In this situation, the network administrator can easily
create an ESG for each enclave using EPG selectors.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 28 of 49
Figure 30. Design Example: multiple default security zones for a given VRF
instance
Example 3: Tag Selectors with VMM integration This is an example of ESG tag
selectors matching VM tags or VM names from VMware vCenter. For this use case,
VMM domain integration with read-write permissions is required, as opposed to
read-only. Although Cisco APIC with read-only integration retrieves VM names
and tags from VMware vCenter, such data is not associated to tenant objects
such as EPGs or ESGs. Thus, you currently cannot leverage those for ESG
selectors.
When VM tags or VM names are used for tag selectors, the following two
configurations are required on top of the tag selectors themselves.
Enable “Tag Collection” under the VMM domain itself. Enable “Allow Micro-
Segmentation” through the VMM domain association in the EPG.
This deploys PVLAN on Cisco ACI leaf switches and VMware vCenter port groups
automatically. This is
to prevent VMware virtual switches from bridging the traffic within the same
port group without forwarding the traffic to Cisco ACI.
Figure 31. Design Example: Tag selectors with VMM integration
Example 4: Tag selectors without VMM integration for VM endpoints using the
MAC address This example shows ESG tag selectors matching VM endpoints using
the MAC address. This option is applicable to those customers who have ESX
clusters without read-write VMM integration.
You can connect the VM endpoints on VMware vCenter to a Cisco ACI fabric
through a “physical” domain without vCenter VMM integration. If you are using
physical domains for VMware vCenter, you can optionally have readonly VMM
integration such that the Cisco APIC can have visibility of the VM endpoints
attachment. However, you cannot use VM tags or VM names on VMware vCenter for
ESG classification without read-write VMM integration.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 29 of 49
In the following example, the following three configuration option are
required on top of tag selectors themselves:
Manually create and assign a Cisco APIC policy tag to each MAC address on the
Cisco APIC. Manually configure PVLAN on both Cisco ACI EPGs (VLANs) and port
groups in VMware vCenter.
This prevents VMware virtual switches from bridging the traffic within the
same port group without
forwarding the traffic to Cisco ACI. (Optional) Enable proxy ARP on the EPGs.
When PVLAN is enabled, flooding or layer 2 multicast traffic is blocked within
each EPG as well as
between EPGs with PVLAN. This results in ARP not being resolved between
endpoints in those EPGs, proxy ARP resolves this limitation by Cisco ACI leaf
switches responding to the ARP requests on behalf of the target endpoint. Note
that communication between endpoints in different subnets do not need proxy
ARP because ARP requests to the Cisco ACI bridge domain SVI, which should be
the default gateway, is not blocked by PVLAN. Configure PVLAN on Cisco ACI
EPGs with physical domains manually using static ports (static path binding).
PVLAN on Cisco ACI EPGs requires one of the following configurations as well:
Enable Intra-EPG isolation Configure Intra-EPG contract You can also enable
proxy ARP along with the following options:
Enable Intra-EPG isolation, then explicitly enable proxy ARP Configure Intra-
EPG contract, then proxy ARP is implicitly enabled In this example, the first
option (Intra-EPG isolation with proxy ARP) is used.
Note: To streamline the integration process, network administrators can use
automation tools such as Ansible, Terraform, or python to read the virtual
machine MAC addresses from VMware vCenter and then create the MAC tags in the
Cisco APIC. Automation could also be used to create both the EPG/VLAN static
bindings in the Cisco APIC, and the PVLAN port groups in VMware vCenter.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 30 of 49
Figure 32. Design Example: Tag selectors without VMM integration for VM
endpoints using the MAC address
Example 5: Tag selectors without VMM integration for VM endpoints using the IP
address This example shows ESG tag selectors matching VM endpoints via IP
address. This option is applicable to those customers who have ESX clusters
without Read-Write VMM integration.
The VM endpoints on VMware vCenter can be connected to a Cisco ACI fabric
through a “physical” domain without vCenter VMM integration. Customers using
physical domains for VMware vCenter may optionally have read-only VMM
integration such that the Cisco APIC can have visibility of VM endpoints
attachment. However, VM tags or VM names on VMware vCenter cannot be used for
ESG classification without read-write VMM integration.
In this example, the following three configuration options are required in
addition to the tag selectors:
Manually create and assign a Cisco APIC policy tag to each IP address on the
Cisco APIC. Manually configure PVLAN on both Cisco ACI EPGs (VLANs) and port
groups in VMware vCenter.
This is to prevent VMware virtual switches from bridging the traffic within
the same port group without
forwarding the traffic to Cisco ACI. Enable proxy ARP on the EPGs.
For Cisco ACI switches to apply ESG security based on IP addresses, traffic
must be routed instead of
bridged. To ensure all traffic is handled as routed traffic, you must enable
proxy ARP on the EPGs.
When PVLAN is enabled, flooding or Layer 2 multicast traffic is blocked within
each EPG as well as
between EPGs with PVLAN. This results in ARP not being resolved between
endpoints in those EPGs, Proxy ARP resolves this limitation by the Cisco ACI
leaf switches responding to the ARP requests on behalf of the target endpoint.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 31 of 49
This example is very similar to Example 4: Tag Selectors without VMM
integration for VM endpoints via MAC address, except for the first point (IP
address instead of MAC address) and the third point (proxy ARP is mandatory).
Configure PVLAN on Cisco ACI EPGs with physical domains manually using static
ports (static path binding). PVLAN on Cisco ACI EPGs requires one of the
following configurations as well:
Enable intra-EPG isolation Configure intra-EPG contract Proxy ARP can also be
enabled along with the following options:
Enable intra-EPG isolation, then explicitly enable proxy ARP Configure intra-
EPG contract, then proxy ARP is implicitly enabled This example uses the first
option (intra-EPG isolation and proxy ARP).
Note: To streamline the integration process, network administrators can use
automation tools such as Ansible, Terraform, or python to read the virtual
machine IP addresses from VMware vCenter and then create the IP tags in the
Cisco APIC. You can also use automation to create both the EPG/VLAN static
bindings in the Cisco APIC and the PVLAN port groups in VMware vCenter.
Figure 33. Design Example: Tag selectors without VMM integration for VM
endpoints using the IP address
Example 6: Tag selectors for bare metal endpoints using the MAC address This
example shows ESG tag selectors matching bare metal endpoints through a Cisco
ACI policy tag statically attached to each endpoint MAC address.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 32 of 49
This is identical to Example 4: Tag selectors without VMM integration for VM endpoints via MAC address with the exception of not configuring the vDS. The PVLAN configuration is also not required on the EPG because there are no intermediary switches such as blade or virtual switches. If there are non- Cisco ACI switches between the endpoints and Cisco ACI switches, PVLANs are still required. See Example 8: Tag selectors with intermediary switches for an example use case.
Figure 34. Design Example: Tag selectors for bare metal endpoints using the
MAC address
Example 7: Tag selectors for bare metal endpoints using the IP address This
example shows ESG tag selectors matching bare metal endpoints through a Cisco
ACI policy tag attached to each endpoint IP address.
This is identical to Example 5: “Tag selectors without VMM integration for VM
endpoints via IP address” with the exception of not configuring the vDS. The
PVLAN configuration is also not required on the EPG because there are no
intermediary switches such as blade switches. If there are non-Cisco ACI
switches between the endpoints and Cisco ACI switches, PVLANs are still
required. See Example 8: “Tag selectors with intermediary switches” for an
example use case.
Note: Proxy ARP is still required, as this example is using the IP address as
the selection criteria.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 33 of 49
Figure 35. Design Example: Tag selectors for bare metal endpoints using IP
addresses
Example 8: Tag selectors with intermediary switches This is an example where
there are intermediary switches between Cisco ACI leaf switches and endpoints.
In the case of VM endpoints, those may be behind blade switches such as Cisco
UCS Fabric Interconnect or virtual switches from any virtualization solution.
In such a case, PVLANs need to be extended from the Cisco ACI leaf switch
through the intermediary switches to the vDS port groups on the virtual
switches. This is to ensure that those switches do not bridge the traffic
based on VLANs before it reaches a Cisco ACI leaf switch where ESG security is
applied.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 34 of 49
Figure 36. Design Example: Tag selectors with intermediary switches
Example 9: IP subnet selectors This is an example of how to specify IP
addresses or subnets directly under an ESG without a tag. This is useful when
all IP addresses within a specific range should belong to the same ESG.
Because this uses the IP address as the criteria, the proxy ARP requirement
mentioned in other IP address examples is also applicable here. Because of
that, if all endpoints in a bridge domain subnet or multiple bridge domain
subnets should belong to the same ESG, we recommend that you use EPG selectors
to match all EPGs in the bridge domains instead. However, EPG selectors are
not supported when the EPGs and the ESG belong to different tenants, such as
when the EPGs belong to tenant common while the ESG belongs to a user tenant.
In such a case, you can still use IP subnet selectors.
In this example, IP subnet selectors are used to classify one half of each
bridge domain subnet into one ESG and the other half to another ESG,
regardless if the endpoints are VMM-integrated or bare metal. For VM
endpoints, due to the intermediary virtual switches, PVLAN is required on the
port groups. In this example, the “Allow Microsegmentation” option with VMM
integration is used to achieve that. “Allow Micro-Segmentation” also
implicitly enables proxy ARP.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 35 of 49
Figure 37. Design Example: IP Subnet Selectors
Example 10: ESG as a container of an application using tag selectors with a
default security zone using EPG selectors The following example uses different
types of selectors together:
A security zone per VRF instance (EPG selectors) A default security zone for
the VRF instance as a catch-all group with intra-ESG isolation so that by
default no endpoints can talk to each other
A security zone per application (tag selectors with VMM integration) – To pull
endpoints from the default security zone so that they can talk to the others
in the same group or another group using contracts.
This is equivalent to an example from the Network Centric to Application
Centric Migration Story: Pseudo Co. chapter.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 36 of 49
Figure 38. Design Example: Tag selectors for ESG per application and EPG
selectors for a default security zone
Example 11: Multiple security zones using EPG selectors with a quarantine ESG
using tag selectors. The following example uses different types of selectors
together:
A security zone per subnets/VLANs (EPG selectors) As base security zones per
enclave that consist of a set of subnets or VLANs that are represented by
EPGs. Endpoints in each zone (ESG) can talk to each other by default.
Communication across each zone is explicitly allowed using contracts.
A quarantine security zone (Tag selectors with VMM integration) – To pull
malicious endpoints from each security zone to quarantine them. A quarantine
zone is configured with intra-ESG isolation to block all traffic inside the
zone (ESG).
This is using the same set of selectors (EPG and Tag) as Example 10: ESG as a
container of application via Tag selectors with a default security zone via
EPG selectors, but in the opposite way. In this example, by default, endpoints
belong to a respective security zone (ESG) with appropriate security settings
based on the network distribution (subnets/VLANs) while tags are used to
revoke security policies allowing communications from certain endpoints.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 37 of 49
Figure 39. Multiple security zones using EPG selectors with a quarantine ESG
using tag selectors.
Example 12: ESG with Layer 2 multicast When Layer 2 multicast is required for
endpoint communication within an ESG, such as cluster keepalive or multicast
DNS, the configuration options shown below interfere with the requirements, as
those options block flooding and Layer 2 multicast traffic.
Intra-EPG isolation Intra-EPG contract “Allow Micro-Segmentation” with a VMM
domain Note: Intra-EPG isolation/contract blocks flooding and Layer 2
multicast traffic between EPGs and within EPGs that have these settings.
However, with “Allow Micro-Segmentation,” the scope of impact is VLANs instead
of the entire EPG.
This means that selectors that require these configurations cannot be used in
such a situation.
Selectors that can be used for Layer 2 multicast, in other words selectors
that do not need any of the above configurations, are:
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 38 of 49
EPG selectors Tag selectors with MAC addresses The details of each selector
are explained below.
EPG Selectors These selectors do not require any of the configuration options
mentioned above that interfere with Layer 2 multicast forwarding.
Refer to Example 1 or Example 2.
Tag Selectors with MAC Address These selectors can meet the requirement of
Layer 2 multicast when a PVLAN is not required. That is, when there are no
intermediary switches in between the leaf switch and the endpoint.
Refer to Example 6: Tag Selectors for bare metal endpoints via MAC address.
Tag Selectors with VM Tags or VM Names These selectors cannot be used because
these require “Allow Micro-Segmentation” with a VMM domain.
IP-based Selectors Such as IP Subnet Selectors or Tag Selectors with an IP
Address These selectors cannot be used because these require proxy ARP on the
EPGs, which is configured using intraEPG isolation, intra-EPG contracts or
“Allow Micro-Segmentation” with a VMM domain.
Example 13: EPG Selectors and IP-based Selectors Without a VMM Domain As shown
in the following examples, proxy ARP is required when using IP addresses as
the criteria for selectors:
Example 5: Tag selectors without VMM integration for VM endpoints via IP
address Example 7: Tag Selectors for bare metal endpoints via IP address
Example 9: IP Subnet Selectors To enable proxy ARP, example 5 listed the
following options:
Enable intra-EPG isolation, then enable proxy ARP Configure intra-EPG
contract, then proxy ARP is implicitly enabled Note: In addition to the two
options above, “Allow Micro-Segmentation” for VMM integration also enables
proxy ARP implicitly for the VLANs deployed for the VMM integration. In such a
case, the consideration mentioned below in this example is not applicable.
There is a consideration with these two options when EPG selectors are used
because when EPGs are matched to an ESG, all security configurations including
these two must be performed using the ESG instead of individual EPGs. This
emanates from the philosophy of the ESG: decouple network and security to keep
configuration and design easy to understand and maintain. The problem is when
intra-ESG isolation is enabled in the ESG, all traffic within the ESG is
blocked even though users can now enable proxy ARP under the matched EPGs. On
the other hand, intra-ESG contract in the ESG enforces contract rules on
traffic within the same ESG, but proxy ARP is not enabled under the hood
unlike intra-EPG contract.
To overcome these problems, the following configuration options should be
applied when both EPG selectors and IP-based selectors are used
simultaneously.
1. Enable intra-EPG isolation and proxy ARP on the EPGs.
2. Enable intra-ESG isolation on the ESG.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 39 of 49
a. This ensures that the EPG configuration in Step 1 is not overridden by the
ESG in Step 4. 3. Enable an intra-ESG contract with permit all, such as the
default filter on the ESG.
a. This allows open communication within the ESG, which is blocked otherwise
by Step 2. 4. Match the EPGs to the ESG using EPG selectors. The following
figure illustrates this example with these configuration options:
Figure 40. Considerations when EPG selectors and IP-based selectors are used
simultaneously
Appendix: Cisco ACI Tenant Design Examples Using ESGs
This appendix explains the options to distribute Cisco ACI components (VRF
instance/bridge domain/EPG/ESG) across tenants for a given VRF instance. It is
primarily focused on when ESGs are used for security, but most of the concepts
are applicable regardless of the ESGs.
The table below summarizes the Cisco ACI tenant design examples in this
section. The following subsections explain each example in detail.
Table 4.
Cisco ACI tenant Design Examples
Category
Examples
Tenant Design
Network and Example 1: All are in a user tenant
security
Example 2: VRF instance/bridge
distributions domains/EPGs (VLANs) are in tenant
across tenants common while ESGs are in user tenants
A VRF instance, bridge domains, EPGs and ESGs are in a user tenant
Strict separation between network and security. All network – a VRF instance,
bridge domains, and EPGs (VLANs) are in tenant common Security – ESGs are in
user tenants
Example 3: VRF instance/bridge domains Loose separation between network and security.
are in tenant common while EPGs
Basic network – a VRF instance, bridge domains are in tenant common
(VLANs) and ESGs are in user tenants EPGs (VLANs) and ESGs (security) are in user tenants
Shared
Example 4: Shared services are in the This is applicable when the same VRF instance in tenant common is
services
same VRF instance from tenant common shared across multiple user tenants
across tenants
A VRF instance and bridge domains are in common tenant
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 40 of 49
Example 5: Shared services are in a different VRF instance
EPGs and ESGs are in user tenant2
Regardless of the network and security distributions across tenants, deploy
shared services in its own dedicated VRF instance and configure explicit VRF
instance route leaking to provide connectivity. A VRF instance, bridge
domains, EPGs and ESGs are in user tenant1 A VRF instance and an L3Out are in
user tenant2
The following table summarizes the supported ESG selectors for each tenant design option:
Table 5. Cisco ACI tenant design options and supported ESG selectors
VRF
Bridge Domain EPG
ESG
Supported Selectors
Tenant common Tenant common Tenant common Tenant common Tag Selector (Ep MAC) Tag Selector (Ep IP) Tag Selector (BD Subnet) Tag Selector (Static Endpoint) Tag Selector (VM name) Tag Selector (VM Tag) IP Subnet Selector EPG Selector
Tenant common Tenant common Tenant common User Tenant
Tag Selector (Ep MAC)1 Tag Selector (Ep IP)1 IP Subnet Selector
Tenant common Tenant common User Tenant
User Tenant
Tag Selector (Ep MAC) Tag Selector (Ep IP) Tag Selector (Static Endpoint) Tag Selector (VM name) Tag Selector (VM Tag) IP Subnet Selector EPG Selector
Tenant common User Tenant User Tenant User Tenant
User Tenant User Tenant
User Tenant User Tenant
Tag Selector (Ep MAC) Tag Selector (Ep IP) Tag Selector (BD Subnet) Tag
Selector (Static Endpoint) Tag Selector (VM name) Tag Selector (VM Tag) IP
Subnet Selector EPG Selector
Tag Selector (Ep MAC) Tag Selector (Ep IP) Tag Selector (BD Subnet) Tag
Selector (Static Endpoint) Tag Selector (VM name) Tag Selector (VM Tag) IP
Subnet Selector EPG Selector
Footnote 1: Policy Tags in the user tenant can be assigned to the MAC or IP address in tenant common by specifying the name of the bridge domain or VRF instance in tenant common. However, if the user tenant has a bridge domain or VRF instance with the same name, the policy tag is assigned to the MAC or IP address in the bridge domain or VRF instance in the user tenant.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 41 of 49
Example 1: All in a user tenant
This example is one of the most common use cases, where all of objects: a VRF
instance, bridge domains, EPGs and ESGs are in a user tenant. Contracts
between ESGs are also in the same user tenant.
Figure 41. Intra-tenant design logical diagram (a VRF instance, bridge
domains, EPGs and ESGs are in a user tenant)
Example 2: VRF instance/bridge domains/EPGs (VLANs) in tenant common while
ESGs in user tenants
This example has ESGs in a user tenant whereas the VRF instance, the bridge
domains and the EPGs are in the common tenant. Contracts between ESGs are
defined in the same user tenant. An EPG selector cannot be used in this
example because the EPGs must belong to the same tenant as the ESG for EPG
selector.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 42 of 49
Figure 42. Intra-tenant design logical diagram (a VRF instance, bridge
domains, and EPGs are in the common tenant)
Example 3: VRF instance/bridge domains are in tenant common while EPGs (VLANs)
and ESGs are in user tenants
This example has EPGs and ESGs in a user tenant whereas the VRF instance and
the bridge domains are in the common tenant. Contracts between ESGs are
defined in the same user tenant.
Figure 43. Intra-tenant design logical diagram (a VRF instance and bridge
domains are in the common tenant)
Example 4: Shared services in the same VRF instance from tenant common
This example has EPGs and ESGs in each of the user tenants whereas the VRF
instance and the bridge domains are in the common tenant. Although this
example uses an inter-tenant contract, this example still allows intra-VRF
instance communication by using a VRF instance in the common tenant. Thus,
there is no need to configure route leaking. Inter-tenant intra-VRF instance
contracts between ESGs must be defined in either the common or provider
tenant. If the contract is defined in the provider tenant, the contract must
be exported to the consumer tenant (Figure 45).
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 43 of 49
Figure 44. Inter-tenant ESG contract with network constructs in the common tenant (the contract is in the common tenant)
Figure 45. Inter-tenant ESG contract with network constructs in the common
tenant (the contract is in the provider tenant)
Example 5 Shared services in a different VRF instance
This example has an L3Out in tenant common or a user tenant that has an inter-
tenant inter-VRF instance contract with another user tenant that has a VRF
instance, bridge domains, EPGs, and ESGs. Inter-tenant interVRF instance
contracts between the L3Out external EPG and ESGs need to be defined in either
the common or provider tenant. If the contract is defined in the provider
tenant, the contract must be exported to the consumer tenant (Figure 47).
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 44 of 49
Figure 46. Inter-tenant ESG contract with shared L3Out in the common tenant (the contract is in the common tenant)
Figure 47. Inter-tenant ESG contract with shared L3Out in another user tenant
(the contract is in the provider tenant)
Inter-VRF instance route-leaking is required for this example. The location is
at Tenant > Networking > VRFs > VRF_name > Inter-VRF Leaked Routes for ESG.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 45 of 49
Figure 48. Inter-VRF instance route leaking configuration (from tn-demo/vrf-01 to tn-shared-services/vrf-01)
Figure 49. Inter-VRF instance route-leak configuration (from tn-shared-
services/vrf-01 to from tn-demo/vrf-01)
FAQ
This section covers frequently asked questions.
Q. What if there are intermediary switches between servers and Cisco ACI leaf
nodes? A. See the “Example 8: Tag Selectors with intermediary switches
section”.
Q. Can I configure contracts between ESGs and EPGs? A. No. When using ESGs,
all security should be handled in ESGs, and EPGs should be used only for
network
constructs such as VLAN. When migrating EPGs to ESGs, EPG selectors can be
used. EPG selectors enable you to inherit contracts from matched EPGs to the
ESG such that communications between the matched EPGs that migrated to the ESG
and other EPGs that have yet to migrate to ESGs are allowed during the
migration phase. Refer to the following documents for details of ESGs and
contracts:
“Endpoint Security Groups > Contracts” in the Cisco APIC Security
Configuration Guide “Endpoint Security Groups > ESG Migration Strategy” in the
Cisco APIC Security Configuration Guide
Q. What are the minimum Cisco APIC version requirements for ESG selectors? A.
ESG selectors covered in this document are supported beginning in the
following releases:
EPG Selector Cisco APIC release 5.2(1) Tag Selector – Cisco APIC release
5.2(1)
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 46 of 49
IP Subnet Selector – Cisco APIC release 5.0(1) See “Endpoint Security Groups >
Selectors” In the Cisco APIC Security Configuration Guide as well.
Q. What is the scalability of ESG? A. Refer to the Endpoint Security Groups
(ESG) section in the Verified Scalability Guide for Cisco APIC
Q. How do ESGs help with TCAM resource utilization compared to EPGs? A. The
amount of TCAM resources on switches that are consumed by contracts with EPGs
or ESGs is the same
when the number of EPGs/ESGs and contracts are the same. However, ESGs provide
you with more flexible options to create security groupings such as
aggregating multiple EPGs into one ESG and consume/provide contracts from the
single ESG instead of multiple EPGs. As a result, using ESGs may help you
optimize the usage of TCAM resources on switches.
Q. What is the ESG selector precedence? A. The tables below list the
priorities. This is also documented in “Endpoint Security Groups > Precedence
of
Selectors” in the Cisco APIC Security Configuration Guide.
Table 6.
Precedence for switched traffic
Precedence 1
2 3
Selector Tag Selector (Endpoint MAC Tag) Tag Selector (Static Endpoint) Tag Selector (VMM Endpoint MAC Tag) EPG Selector
Table 7.
Precedence for routed traffic
Precedence
Selector
1
Tag Selector (Endpoint IP Tag)
IP Subnet Selector (host IP)
2
Tag Selector (BD subnet)
IP Subnet Selector (subnet)
3
Tag Selector (Endpoint MAC Tag)
Tag Selector (Static Endpoint)
4
Tag Selector (VMM Endpoint MAC Tag)
5
EPG Selector
Q. What is the difference between read-only and read/write VMM domains? A. VMware vCenter VMM domain has the following integration options:
In a read/write VMM domain (default option) the network admin simply maps an
EPG to a VMM domain. The network controller (Cisco APIC) selects an unused
VLAN from a VLAN pool, adds the VLAN to all host facing ports, and configures
a port group on the VMware vDS with the EPG name and the correct VLAN ID
through VMware vCenter’s public API in the same way that Ansible/Terraform
does. This approach mitigates the risk of VLAN mismatches between the physical
network and the vDS. ESG tag selectors with VM tags or VM names from VMware
vCenter can be used only in this mode.
In a read-only VMM domain the configuration in Cisco APIC does not get
propagated to VMware vCenter to keep a clear configuration domain separation
whilst still providing the network admin on Cisco APIC the visibility of the
port groups, VLANs and VMs on the VMware vCenter. In this mode, the network
admin configures an EPG with a given VLAN ID on all host facing ports, the
network admin then informs the VMware vCenter admin of the VLAN ID such that
the admin can create a port group on the vDS with the same VLAN ID.
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 47 of 49
Q. How do security devices such as firewalls and IPS, which are inserted into
the traffic path, identify security
groups in an application-centric design where subnets might not be used as the
security group boundary?
A. The following application and plug-ins are currently available for ESG
membership advertisement:
Cisco Adaptive Security Appliance (ASA) and Cisco Firepower Threat Defense
(FTD): Cisco ACI Endpoint Update
Palo Alto Networks Panorama: Panorama Plugin for Cisco ACI (Roadmap)
If your Layer 4 to Layer 7 services device is different from those listed
above, endpoints to ESG membership information can be retrieved using the
Cisco APIC API. Thus, you can use a simple script or application to retrieve
the information and create equivalent security groups on the Layer 4 to Layer
7 services device.
The following API query retrieves all endpoints and associated IP addresses
from a specific ESG:
https://{{apic}}/api/mo/uni/tn-{{tenantName}}/ap-{{appProfileName}}/esg{{esgName}}.json
?query-target=subtree&target-subtree-class=fvCEp&rspsubtree=children&rsp-
subtree-class=fvIp
The Cisco APIC response includes each endpoint connected to the ESG, and
(where available) the endpoint IP address:
{ “fvCEp”: { “attributes”: { “annotation”: “”, “baseEpgDn”: “uni/tn-demo/ap-
network-segments/epg-192.168.52.x_24”, “bdDn”: “uni/tn-
demo/BD-192.168.52.x_24”, “childAction”: “deleteNonPresent”, “contName”:
“email-service”, “dn”: “uni/tn-demo/ap-online-boutique-hx/esg-all-
services/cep-
00:50:56:A1:81:D3”, “encap”: “vlan-1206”, “esgUsegDn”: “”, “extMngdBy”: “”,
“fabricPathDn”: “topology/pod-1/paths-102/pathep-[hx-dev-01-fi-b]”,
“hostingServer”: “10.237.98.148”, “id”: “0”, “idepdn”: “”, “lcC”:
“learned,vmm”, “lcOwn”: “local”, “mac”: “00:50:56:A1:81:D3”, “mcastAddr”:
“not-applicable”, “modTs”: “2023-04-12T11:55:42.679+01:00”, “monPolDn”: “”,
“name”: “00:50:56:A1:81:D3”, “nameAlias”: “”, “reportingControllerName”: “hx-
dev-01-vc01.uktme.cisco.com”, “status”: “”, “uid”: “0”, “userdom”: “all”,
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 48 of 49
“uuid”: “”, “vmmSrc”: “dvs”, “vrfDn”: “uni/tn-demo/ctx-vrf-01” }, “children”:
[ {
“fvIp”: { “attributes”: { “addr”: “192.168.52.31”, “annotation”: “”,
“baseEpgDn”: “uni/tn-demo/ap-network-segments/epg-
192.168.52.x_24”, “bdDn”: “uni/tn-demo/BD-192.168.52.x_24”, “childAction”:
“deleteNonPresent”, “createTs”: “2023-04-12T12:00:43.000+01:00”,
“debugMACMessage”: “”, “esgUsegDn”: “”, “extMngdBy”: “”, “fabricPathDn”:
“topology/pod-1/paths-102/pathep-[hx-dev-01-
fi-b]”, “flags”: “”, “lcOwn”: “local”, “modTs”:
“2023-04-12T12:00:42.684+01:00”, “monPolDn”: “”, “rn”: “ip-[192.168.52.31]”,
“status”: “”, “uid”: “0”, “userdom”: “all”, “vrfDn”: “uni/tn-demo/ctx-vrf-01”
} } } ] } }
See Also
Cisco APIC Security Configuration Guide, Release 6.0(x)
ACI Segmentation and Migrations made easier with Endpoint Security Groups
(ESG)
Cisco ACI White Papers
© 2023 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
Page 49 of 49