Specifications
- Power consumption: 290W
- Power supply: 100~240V, 50/60Hz
- Fuse: F4A 250V
- Dimensions: 414 x 324 x 221mm
- Weight: 9.7kg
- Order code: EQLED024 – Black Housing, EQLED024A – White Housing
Product Overview
The Fusion 260ZR is a lighting fixture designed for professional use. It
features a black or white housing and comes with various accessories including
omega clamps, a power cable, and a user manual.
Safety Advice
- For your own safety, please read this user manual carefully before your initial start-up.
- Keep this equipment away from rain, moisture, and liquids.
- Take care when using this equipment as it operates at high voltage and there is a risk of electric shock.
- The manufacturer will not accept liability for any damages caused by the non-observance of this manual or any unauthorized modification to the equipment.
- If the lens gets damaged, such as cracks or deep scratches that impair the output, it must be replaced.
Operating Determinations
- Only operate the equipment as described in this manual to avoid damage and voiding the warranty.
- Incorrect operation may lead to dangers such as short-circuits, burns, and electric shocks. Ensure your own safety and the safety of others.
- Incorrect installation or use can cause serious damage to people and/or property.
Installation
- Before installing the fixture, ensure that the supporting structure (e.g., truss) can hold a minimum of 10 times the fixture’s weight without deformation.
- Secure the fixture with a secondary safety attachment, such as an appropriate safety cable, during installation.
- Avoid standing directly below the fixture when mounting, removing, and/or servicing.
- Overhead installation requires experience and qualifications to calculate working load limits and ensure the safety of the installation. If you lack relevant experience and qualifications, do not attempt the installation yourself.
5. The installation should be checked annually by a qualified person.
FAQ
-
Q: Can the Fusion 260ZR be used outdoors?
A: It is recommended to keep the equipment away from rain, moisture, and liquids. Therefore, outdoor use may not be suitable unless appropriate weather protection measures are taken. -
Q: How often should the lens be replaced?
A: The lens should be replaced if it gets damaged, such as cracks or deep scratches that impair the output. Regular inspection is recommended to ensure optimal performance. -
Q: Can I install the fixture myself without any experience or qualifications?
A: Overhead installation requires experience and qualifications to ensure safety. If you lack relevant experience and qualifications, it is recommended to seek professional assistance.
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR
INITIAL START-UP!
- Before your initial start-up, please make sure that there is no damage caused during transportation.
- Should there be any damage, consult your dealer and do not use the equipment.
- To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual.
- Please note that damages caused by user modifications to this equipment are not subject to warranty.
CAUTION!
KEEP THIS EQUIPMENT AWAY FROM RAIN, MOISTURE AND LIQUIDS CAUTION!
TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!!
IMPORTANT
The manufacturer will not accept liability for any resulting damages caused by
the non-observance of this manual or any unauthorised modification to the
equipment.
- Never let the power cable come into contact with other cables. Handle the power cable and all mains voltage connections with particular caution!
- Never remove warning or informative labels from the unit.
- Do not open the equipment and do not modify the unit.
- Do not connect this equipment to a dimmer pack.
- Do not switch the equipment on and off in short intervals, as this will reduce the system’s life.
- Only use the equipment indoors.
- Do not expose to flammable sources, liquids or gases.
- Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable.
- Make sure that the available mains supply voltage is between 100~240V AC, 50/60Hz.
- Make sure that the power cable is never crimped or damaged. Check the equipment and the power cable periodically.
- If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not connect power or switch it on immediately.
- The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature.
- Never touch the fixture during operation as it may be hot.
- If the equipment is dropped or damaged, disconnect the mains power supply immediately and have a qualified engineer inspect the equipment before operating again.
- If your product fails to function correctly, stop use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Pro Light dealer for service.
- Only use fuses of same type and rating.
- Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS.
- This lighting fixture is for professional use only – it is not designed for or suitable for household use. The product must be installed by a qualified technician in accordance with local territory regulations. The safety of the installation is the responsibility of the installer. The fixture presents risks of severe injury or death due to fire hazards, electric shock and falls.
- Warning! Risk Group 2 LED product according to EN 62471. Do not view the light output with optical instruments or any device that may concentrate the beam.
- WARRANTY : One year from date of purchase.
OPERATING DETERMINATIONS
If this equipment is operated in any other way, than those described in this
manual, the product may suffer damage and the warranty becomes void. Incorrect
operation may lead to danger e.g: short-circuit, burns and electric shocks
etc.
Do not endanger your own safety and the safety of others!
Incorrect installation or use can cause serious damage to people and/or
property.
This fixture falls under Protection Class 1, therefore it has to be connected
to a mains socket with a protective earthing connection.
Risk group 2, RG-2: CAUTION!
Do not stare at exposed LED in operation as it may damage/be harmful to the
eyes. Avoid looking directly into the light source.
CAUTION!
The maximum ambient temperature (Ta) of 40° must not be exceeded.
CAUTION!
If the lens gets damaged ie. cracks or deep scratches so the output is
impaired then it must be replaced.
Product overview & technical specifications
Fusion 260ZR
The Fusion 260ZR LED Wash features 19 x 12W quad-colour LEDs (RGBW) outputting
gentle pastels to rich saturated colours. Arranged in 3 concentric circles the
LEDs offer many different programming options to create stunning colour and
pattern effects as well as providing a comprehensive wash coverage. The unit
is
also equipped with a 6°- 50° motorised zoom.
- 19 x 12W quad-colour LEDs (RGBW)
- Adjustable beam angle: 6°- 50°
- 6° – 40,098 Lux @ 2m (full on), 50° – 6,316 Lux @ 2m (full on)
- 4.5kHz refresh rate
- Motorised zoom
- Pixel zone mapping
- DMX channels: 2/8/17 or 25 selectable
- Auto, sound active and master/slave modes
- Pan/tilt auto correction
- 16-Bit pan/tilt positioning
- Pan: 540°, Tilt: 270°
- 0 – 100% dimming and variable strobe
- Supplied with quick release omega clamps
- Square hole spacing on omega clamp receivers allows for clamps to be mounted in all orientations
- 4 push button menu with LCD display
- PowerCON input/output
- 3-Pin XLR input/output
- Fan cooled
Specifications | Fusion 260ZR |
---|---|
Power consumption | 290W |
Power supply | 100~240V, 50/60Hz |
Fuse | F4A 250V |
Dimensions | 414 x 324 x 221mm |
Weight | 9.7kg |
Order code | EQLED024 – Black Housing EQLED024A – White Housing |
Technical specifications
- LCD display
- Function buttons
- 3-Pin DMX input
- 3-Pin DMX output
- PowerCON input
- PowerCON output
- Fuse F4A 250V
- Power switch
- Carry handles
In the box
- 1 x fixture,
- 2 x omega clamps,
- 1 x power cable
- & 1 x user manual
Installation
- Before installing the fixture, the supporting structure (ie. truss) must be able to hold a minimum of 10 times the fixtures weight without any deformation (eg. 15kg – 150kg point load).
- The fixture must be secured with a secondary safety attachment when being installed (ie. an appropriate safety cable). Never stand directly below the fixture when mounting, removing, and/or servicing.
- Overhead installation requires experience and qualifications to calculate working load limits, the material being used at the installation area and periodic safety inspections of the fixture and installation material. If you do not have the relevant experience and/or qualifications please do not attempt the installation yourself. The installation should be checked annually by a qualified person.
The Equinox Fusion 260ZR can be operated in a number of mounting positions as
shown in the diagram above, hanging upside-down from the ceiling or truss,
mounting sideways on truss or stood upright on a flat level surface. Always
use a safety wire as an extra safety precaution to prevent damage/injury in
the event a clamp fails (see the next page for clamp installation).
Never use the carry handles for secondary attachments.
Installation
- Fasten each clamp to the omega clamps with a bolt and lock nut through the hole in the omega clamp.
- Align and insert the omega clamp quick-lock fasteners with the respective holes on the bottom of the unit.
- Tighten both locking fasteners clockwise on each omega clamp ensuring they’re fully secure.
- Mount the fixture onto your truss system via the clamps and tighten to ensure secure.
- Pull the safety cable through the safety cable holes located on the metal base plate on the underside of the fixture and around the truss.Operating instructions
Operating instructions
Control Panel Menu
- The LCD control panel situated on the front of the fixture allows the user to access the menu system to adjust the fixtures settings.
- When the unit has been powered on the display will show “Equinox Fusion 260ZR”, “Motor Reset… Please Wait…” whilst the unit performs its motor reset. The fixture will then return to its home screen.
- Pressing the “ENTER” button once will take the user to the fixtures main menu. Using the “UP” and “DOWN” buttons you can then navigate between the different options in the main menu. Pressing the “ENTER” button on one of these options allows you to access the sub menu where you can use the “UP” and “DOWN” buttons to select option/value required. Once the option/value has been selected press the “ENTER” button once more to confirm the setting.
- To exit out of any of the above options, press the “MENU” button.
Main Menu – Defaults are in grey
-
DMX address:
To access the DMX address mode, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “DMX Address” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required DMX address. Press the “ENTER” button to confirm the setting. -
DMX channel mode:
To access the DMX channel mode, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Channel Mode” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required DMX channel. Press the “ENTER” button to confirm the setting. -
Show mode:
To access the show modes, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Show Mode” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required show mode. Press the “ENTER” button to confirm the setting.
Show 3 & 4 are forward facing show modes. -
Master/slave mode
To access the master/slave modes, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Master/Slave” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to set the required mode. Press the “ENTER” button to confirm the setting. -
Sound mode
To access the sound mode setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Sound” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “ON” and “OFF”. Press the “ENTER” button to confirm the setting. -
Sound sensitivity
To access the sound sensitivity setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Sound Sensitivity” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “000” and “100”. Press the “ENTER” button to confirm the setting. -
Manual control:
To access manual control mode, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Manual Control” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select the various options. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “000” – “255”. Press the “ENTER” button to confirm the setting. -
Pan invert:
To access the pan invert setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Pan Invert” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “No” and “Yes”. Press the “ENTER” button to confirm the setting. -
Tilt invert
To access the tilt invert setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Tilt Invert” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “No” and “Yes”. Press the “ENTER” button to confirm the setting. -
DMX fail
Sets what the fixture does when the DMX signal is lost. To access the DMX fail setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “DMX Fail” on the LCD display. Now press the “ENTER” button and use the “UP” and “DOWN” buttons to choose between “Blackout”, “Hold” or “Show mode”. Press the “ENTER” button to confirm the setting. -
Display backlight:
To access the display backlight setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Display Settings” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select “Backlight”.Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “Off” and “On”. Press the “ENTER” button to confirm the setting. -
Display invert
To access the display invert setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Display Settings” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select “Invert”.Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “No” and “Yes”. Press the “ENTER” button to confirm the setting. -
Calibration:
Calibration settings for the fixture.
To access the units calibration menu press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Calibration”. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select the various options. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “000” – “255”.
Press the “ENTER” button to confirm the setting.
Please note: Calibration settings are set when the fixture is manufactured. This can be changed manually for home position adjustment. Performing a factory reset will not change these settings. -
System information
To display the fixtures system information, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “System Information” on the LCD display The unit will now display the fixtures current run time, total run time, temperature and software version. -
Auto test:
Tests all functions and motors in the fixture.
To access the auto test mode, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Auto Test” on the LCD display. Press the “ENTER” button and the fixture will initiate auto test.
Please note: Auto test will automatically stop when exiting the auto test menu. -
Motor reset:
Resets all the fixtures motors.
To access the motor reset setting, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Motor Reset” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “Yes” and “No”. Press the “ENTER” button to perform the motor reset when yes is selected. -
Factory Reset:
Resets all the fixtures factory settings.
To access the factory setting reset, press the “ENTER” button and use the “UP” and “DOWN” buttons to show “Factory Reset” on the LCD display. Press the “ENTER” button and use the “UP” and “DOWN” buttons to select between “Yes” and “No”. Press the “ENTER” button to perform the factory reset when yes is selected.
2 channel mode
Channel | Value | Function |
---|
CH1
| 000-015| No function
016-075| Show 1
076-135| Show 2
136-195| Show 3 (single colours only)
196-255| Show 4 (forward facing show)
CH2| 000| Blackout
001-255| Sound sensitivity (low-high)
8 channel mode
Channel | Value | Function |
---|---|---|
CH1 | 000-255 | Pan adjustment 0-540° |
CH2 | 000-255 | Tilt adjustment 0-270° |
CH3 | 000-255 | Zoom (narrow-wide) |
CH4 | 000-255 | Master dimmer (0-100%) |
CH5 | 000-255 | Red dimmer (0-100%) |
CH6 | 000-255 | Green dimmer (0-100%) |
CH7 | 000-255 | Blue dimmer (0-100%) |
CH8 | 000-255 | White dimmer (0-100%) |
17 channel mode
Channel | Value | Function |
---|---|---|
CH1 | 000-255 | Pan adjustment 0-540° |
CH2 | 000-255 | Pan fine |
CH3 | 000-255 | Tilt adjustment 0-270° |
CH4 | 000-255 | Tilt fine |
CH5 | 000-255 | Pan/tilt speed (fast-slow) |
CH6 | 000-255 | Zoom (narrow-wide) |
CH7 | 000-255 | Master dimmer (0-100%) |
CH8 | 000-015 | No function |
016-254 | Strobe (slow-fast) | |
255 | No function | |
CH9 | 000-255 | Red dimmer (0-100%) |
CH10 | 000-255 | Green dimmer (0-100%) |
CH11 | 000-255 | Blue dimmer (0-100%) |
CH12 | 000-255 | White dimmer (0-100%) |
CH13
| 000-015| No function
016-075| Show 1
076-135| Show 2
136-195| Show 3 (single colours only)
196-255| Show 4 (forward facing show)
CH14| 000-255| Sound sensitivity (low-high)
CH15
| 000-015| No function
016-122| Colour macros
123-181| Colour & Zoom Program 1
182-240| Colour & Zoom Program 2
241-255| Colour Change (Sound)
CH16| 000-255| Colour program speed (slow-fast)
CH17| 000-127| No function
128-255| Reset (hold for 5 seconds)
25 channel mode
Channel | Value | Function |
---|---|---|
CH1 | 000-255 | Pan adjustment 0-540° |
CH2 | 000-255 | Pan fine |
CH3 | 000-255 | Tilt adjustment 0-270° |
CH4 | 000-255 | Tilt fine |
CH5 | 000-255 | Pan/tilt speed (fast-slow) |
CH6 | 000-255 | Zoom (narrow-wide) |
CH7 | 000-255 | Master dimmer (0-100%) |
CH8 | 000-015 | No function |
016-254 | Strobe (slow-fast) | |
255 | No function | |
CH9 | 000-255 | Red circle 1 dimmer (0-100%) |
CH10 | 000-255 | Green circle 1 dimmer (0-100%) |
CH11 | 000-255 | Blue circle 1 dimmer (0-100%) |
CH12 | 000-255 | White circle 1 dimmer (0-100%) |
CH13 | 000-255 | Red circle 2 dimmer (0-100%) |
CH14 | 000-255 | Green circle 2 dimmer (0-100%) |
CH15 | 000-255 | Blue circle 2 dimmer (0-100%) |
CH16 | 000-255 | White circle 2 dimmer (0-100%) |
CH17 | 000-255 | Red circle 3 dimmer (0-100%) |
CH18 | 000-255 | Green circle 3 dimmer (0-100%) |
CH19 | 000-255 | Blue circle 3 dimmer (0-100%) |
CH20 | 000-255 | White circle 3 dimmer (0-100%) |
CH21 | 000-015 | No function |
016-075 | Show 1 | |
076-135 | Show 2 | |
136-195 | Show 3 (single colours only) | |
196-255 | Show 4 (forward facing show) | |
CH22 | 000 | Blackout |
001-255 | Sound sensitivity (low-high) | |
CH23 | 000-015 | No function |
016-122 | Colour macros | |
123-181 | Colour & Zoom Program 1 | |
182-240 | Colour & Zoom Program 2 | |
241-255 | Colour Change (Sound) | |
CH24 | 000-255 | Colour program speed (slow-fast) |
CH25 | 000-127 | No function |
128-255 | Reset (hold for 5 seconds) |
DMX setup
Setting the DMX address
The DMX mode enables the use of a universal DMX controller. Each fixture
requires a “start address” from 1- 512. A fixture requiring one or more
channels for control begins to read the data on the channel indicated by the
start address. For example, a fixture that occupies or uses 7 channels of DMX
and was addressed to start on DMX channel 100, would read data from channels:
100, 101, 102, 103, 104, 105 and 106. Choose a start address so that the
channels used do not overlap. E.g. the next unit in the chain starts at 107.
DMX 512
DMX (Digital Multiplex) is a universal protocol used as a form of
communication between intelligent fixtures and controllers. A DMX controller
sends DMX data instructions form the controller to the fixture. DMX data is
sent as serial data that travels from fixture to fixture via the DATA “IN” and
DATA “OUT” XLR terminals located on all DMX fixtures (most controllers only
have a data “out” terminal).
DMX linking
-
DMX is a language allowing all makes and models of different manufactures to be linked together
and operate from a single controller, as long as all fixtures and the controller are DMX compliant. -
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line, at the beginning, at the end, or anywhere in the middle.
-
When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit, no matter where it is located in the DMX chain.
DATA cable (DMX cable) requirements (for DMX operation)
This fixture can be controlled via DMX-512 protocol. The DMX address is set on
the back of the unit. Your unit requires either a standard 3-pin or 5-pin XLR
connector for data input/output,
see images below.
Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
- Please quote: 3-Pin:
- 5-Pin:
- CABL10 – 2m CABL185 – 2m
- CABL10 – 2m CABL185 – 2m
- CABL12 – 10m CABL188 – 10m
Also remember that DMX cable must be daisy chained and cannot be split.
Notice
Be sure to follow the diagrams below when making your own cables. Do not
connect the cables shield conductor to the ground lug or allow the shield
conductor to come in contact with the
XLRs outer casing. Grounding the shield could cause a short circuit and erratic behaviour.
Pin Configuration
3-Pin| 5-Pin
Pin 1 – Ground
Pin 2 – Negative
Pin 3 – Positive
–| Pin 4 – N/C
–| Pin 5 – N/C
Line termination
When longer runs of cable are used, you may need to use a terminator on the
last unit to avoid erratic behaviour. Using a cable terminator will decrease
the possibilities of erratic behaviour. (3-pin – Order ref: CABL90, 5-pin –
Order ref: CABL89)
5-pin XLR DMX connectors
Some manufactures use 5-pin XLR connectors for data transmission in place of
3-pin. 5-pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When
inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor
must be used. The diagram below details the correct cable conversion.
Multiple fixture power linking
Power linking
This fixture provides power linking via the power output on the rear allowing
multiple units to be connected together. The maximum number of fixtures that
can be connected is 6 fixtures @ 240V or 3 fixtures @ 120V (including the
first fixture). After the maximum number of fixtures are connected a new power
run will need to be started.
Please note : Caution should be used when power linking other fixtures to the Fusion 260ZR as the power consumption of other fixtures will vary. Fixtures fitted with lamps often require 2/3 times more current on startup, these may require their own power source.
WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate
collection systems)
- This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources.
- Household users should contact either the retailer where they purchased this product, or their local government office, for details of where and how they can take this item for environmentally safe recycling.
- Business users should contact their supplier and check the terms and conditions of the purchase contract. This product should not be mixed with other commercial wastes for disposal.
www.prolight.co.uk
Fusion 260ZR User Manual
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>