DESCRIPTION
Abestorm Crawl Space NeatyFresh Max allows for the free circulation of air in
the porch and under the house. High moisture levels in the crawl spaces can
lead to the decay and rot of wooden pillars that support the house, floor,
joists, and beam pillars. Also, high humidity causes an increase in termite
activity and growth of fungi. Rust, which causes corrosion and leaks in
metallic pipes, is also factored by the level of moisture in your crawl space.
With our ventilation fan, radon gas from treated wood is expelled away. This
gas, together with other odors, can easily spread into the living room and
cause discomfort. The NeatyFresh Max fan uses a humidity switch to control the
fan to commence operation. The fan starts operating when the recorded humidity
surpasses the selected value.
Note: To eliminate chances of having the fan disabled when outdoor
temperatures fall below 35 degrees Fahrenheit, the crawl space ventilations
feature pre-installed, and factory-installed thermostats. The fan will resume
normal operations whenever the outdoor temperatures rise above 50 degrees
Fahrenheit.
Parameter
Air flow: 220CFM | Power: 120V~50/60Hz |
---|---|
Max Current: 0.60A | Thermostat: On at 50°F; OFF at 35°F |
Size: 18″x9″x2″ | You can trim the minimum mounting plate to: 14″x6″ |
Dehumidification state: Humidity range 20% to 80%
GENERAL INFORMATION
Before leaving the factory, each of the short building fans must go through a
scrupulous electrical factory test to ensure that they are free from any
malfunction. After making a purchase, thoroughly inspect the product for any
damage once you open the carton. If you notice any damage in a newly purchased
product, notify your dealer and the shipping company immediately. After that,
place a complaint to claim for a new product or a refund.
SETUP
Only qualified technicians can install all Crawl Space ventilations by
Abestorm. Ensure that you adhere to the specifications and the local codes
that governs your area before installation. In the absence of local codes,
follow the up-to-date versions of the international electrical code and
international residential codes. Incorrect installation or failure to conform
to the instructions may expose you to harm or even lead to electric shock,
fire, or personal injury. Following the manufacturer’s instructions to the
latter will reduce the risk posed by electrical equipment. For more
information on the product or queries concerning the appliance, reach the
manufacturer (company name). Before installing or performing maintenance to
the appliance. Also, ensure that it is unplugged from the power supply.
TOOLS REQUIRED
- 5/16-inch flat head or nut roller screwdriver.
- Make use of a 5/16-inch masonry drill if mounting the unit on a foundation block or brick.
- Grounding repository within a distance of 6 feet from the ventilations.
INSTALLATION
Location:
If the low-rise fan NeatyFresh Max are installed in the crawl space at the
back of an existing foundation ventilation opening, it should be at a distance
of not more than three feet from each corner.
Note:
Install the fan in the climbing space. See to it that the motor and electrical
control box face the climbing space.
- Get rid of the coverings or existing doors on the building’s ventilation holes.
- The low-rise fan should be placed above the building’s vent.
- If you mount the unit on a brick or foundation block, mark the aligning on the corners of the metallic panel. Drill a 5/16- inch hole to attach the wall anchor in the vent’s opening. Finally, use four screws to fix the climbing Neaty Fresh Max onto the wall.
the mesh or rim on the crawl space vent. Use nuts and screw washers to mount
the crawl space NeatyFresh on all corners of the metal panel.
MOUNTING PLATE TRIM DIMENSIONS
If adjustments are to be done on the mounting plate to create room for
important openings, follow the outlined trimming procedure. To avoid damaging
the power cord, take precaution when trimming the mounting plate. WIRING
DIAGRAM APPROPRIATE FOR TEMPERATURE RANGE
An Antifreeze thermostat
Note: Some models of the Abe storm low-rise fans have in-built wired
thermostat, which inhibits operation of the fan when the outdoor temperatures
fall below 35 degrees Fahrenheit. Optimal operations will commence once the
temperature rises to about 50 degrees Fahrenheit. Note: Some DE humidistat
models cannot operate whenever the freezing protection senses that the outdoor
temperatures are very low.
Note: If the unit has an antifreeze thermostat, dehumidification will not
take place unless the outdoor temperature is recorded.
WARRANTY SERVICE PLAN
The warranty is a guarantee for you. Products from Abe storm are sold
within 1 year from the manufacturing date. The products are free of
manufacturing defects, both in the process and material. If any fault is found
in the product, both in material and process, Abe storm will take full
liabilities to solve the problems as per the warranty terms. Whenever the
appliance is unavailable, the service plan will take effect from the day the
purchase was made. The service plan can only be effected within 1 year after
the date of purchase after which, it will be rendered null and void. If the
defect occurs during this period, Abestorm will replace it with a new product
or give a refund of the same.
The service plan cannot cover damage due to misuse and abuse of the product.
Nor does it cover damage from water, physical damage, incorrect voltage input,
and other reasons caused by the use of the appliance other than the intended
purpose. Collateral damage and indirect losses liable for normal wear damage
such as scratches are not guaranteed herein.
For queries on information about our distributors and re-sellers, reach our
customer service provider at sales@abestorm.com
or call us at working hours(8:00 AM to 5:00 PM CPST), Monday to Friday.
IMPORTANT NOTICE: Keep the item’s packaging in case warranty service is
required.
NeatyFresh Max
Abestorm Solutions INC.
Add: 8605 SANTA MONlCA BLVD#79525
WEST HOLLYWOOD,California,90069 USA
E-mail: sales@abestorm.com
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>