Installation instructions
Induction hobs
Induction Hobs
The fitting of the appliance should only be carried out by a registered and qualified installer. Please read the safety regulations.
Preparations for installation
Pictograms used
Important information
Electrical connection
Free space around the appliance
This appliance must be earthed
The equipment should not be connected to the network via a multi-plug socket or extension Jlead, as the safe use of the equipment can then not be guaranteed.
Connected load
KIF880DS
KIF880ZT
KIF890ZT| L1 (W)
3700
3700
3700| L2 (W)
3700
3700
3700| L3 (W)
3000
3000
3000| Total load (W) 10400
10400
10400
---|---|---|---|---
Placing sealing tape
Electrical connection
Set power limiter at 7400 W; c8=1; default setting!
Consult the wiring diagrams on the back of the appliance/Make the required connections on the connecting block.
If necessary set the hob power limiter. Consult chapter ‘Installation/Power limiter’ in the user manual. The limiter is set at 7400 W by the factory.
You can find the most recent version of the installation instructions on our website.
838734 / VER 3 / 15-02-2022