Plug Play Induction Hobs Installation Guide
- June 4, 2024
- Plug Play
Table of Contents
Installation instructions
Induction hobs
Induction Hobs
** The fitting of the appliance should only be carried out by a registered
and qualified installer. Please read the safety regulations.
Pictograms use**
Important information
Electrical connection
Free space around the appliance
** This appliance must be earthed
The equipment should not be connected to the network via a multi-plug socket
or extension lead, as the safe use of the equipment can then not be
guaranteed.
Connected load**
L1(W) | L2(W) | L3(W) | Total load (W) |
---|---|---|---|
HI06471E | 3700 | 3700 | 7400 |
HI06471EP | 3700 | 7400 | |
HI06471EV | 3700 | 3700 | 7400 |
HI07471EV | 3700 | 3700 | 7400 |
HI08471EV | 3700 | 3700 | 7400 |
HI08571EV | 3700 | 3700 | 300 |
HI09571EV | 3700 | 3700 | 300 |
A (mm) | B (mm) | C (mm) | D (mm) |
---|---|---|---|
HI06471E/EP/EV | 600 | 520 | 51,5 |
HI07471EV | 700 | 520 | 51,5 |
H108471EV | 800 | 520 | 51,5 |
H108571EV | 800 | 520 | 51,5 |
H109571EV | 840 | 520 | 51,5 |
A (mm) | B (mm) | C (mm) | D ( >mm) | E ( >mm) |
---|---|---|---|---|
H106471E/EP/EV | 560 | 600 | 490 | 40 |
H107471EV | 560 | 600 | 490 | 40 |
H108471EV | 750 | 600 | 490 | 40 |
H108571EV | 750 | 600 | 490 | 40 |
H109571EV | 810 | 600 | 490 | 40 |
Placing sealing tape
Model HI06471EP
**** Electrical connection
2N 380-415V 50/60Hz – 2x 16A
2 fase-1nul /2 phases – 1 neutral
2-2N 220-240V 50Hz – 2x 16A
2 fase – 2 nullen / 2 phases – 2 neutral
1N 220-240V 50/60Hz – 1x 32A
fase-1 null/1phase -1neutral
Cross-sectional area
3×4 mm ( <2m)
3N 380-415V 50/60Hz – 3x 16A
3 fase – 1 nul / 3 phases – 1 neutral
Cross-sectional area
5×1,5 mm (<2m)
Consult the wiring diagrams on the back of the appliance/Make the required
connections on the connecting block.
**** If necessary set the hob power limiter. Consult the chapter ‘Installation/Power limiter’ in the user manual.
You can find the most recent version of the installation instructions on our website.