GENERAL Life HT220S Digital Room Thermostat User Manual
- June 15, 2024
- GENERAL LIFE
Table of Contents
GENERAL Life HT220S Digital Room Thermostat
GENERAL SPECIFICATIONS
HT220S is a wired room thermostat. The user can adjust the room temperature with the required temperature and get more comfortable and economical heating/cooling.
- Precise Temperature Measurement ON/OFF Control
- Heating calibration Wired Connection
- Heating/Cooling Modes TPI Algorithm
HT220S AND EQUIPMENT
TECHNICAL DATA
ROOM THERMOSTAT
ROOM THERMOSTAT PLACEMENT
Room Thermostat needs to be placed in the room that is used most frequently.
For instance; the living room or lounge. Placing the Room The thermostat in a
spot that has air circulation like the entrance of a room or side of the
window should be avoided. Also anywhere close to heating/cooling units such as
radiator, stove and spots which get direct sun lights would not be suitable.
Room Thermostat needs to be located above the floor 150 cm in height. Few
trials may be made to find the most convenient spot.
BATTERY PLACEMENT
Before starting, power off the device connected to the Room Thermostat and make sure that the energy is cut off. As shown in the picture above, press the screwdriver forward from the space shown, bend the tabs and separate the front cover. Insert 2 new AAA alkaline batteries in the battery housing with the correct battery direction. Replace both batteries at the same time. Then align the front part of your Room Thermostat to the back and squeeze it towards the back.
Low Battery Warning
When the “ ” icon appears on the screen, it means “low battery warning”. It
is recommended to replace the batteries when this warning appears.
Warning
When the product is not used for a long period (more than 15 days), remove
the batteries. Otherwise, malfunctions that may occur would be out of
warranty. Please throw your dead batteries into the waste bin for batteries.
ROOM THERMOSTAT WIRING DIAGRAM
Warning!
Operations within the heating/cooling unit or the electrical installation must
be carried out by professionally qualified persons.
ROOM THERMOSTAT TEMPERATURE CALIBRATION
Temperature sensors that are used in Room Thermostats are highly sensitive.
You may need to calibrate your Room Thermostat if you would like to get the
same temperature values as other thermometers in your living space.
- While your device is turned off, press and hold the button for 3 seconds.
- Press the button until the “ ” menu appears. To see the desired temperature, set the temperature difference by turning the button to right or left. This value can be arranged between “-8 C” and o “+8 C”.
- To save the settings and exit, press the “On/Off” button until the device turns off.
- Note : Recommended temperature calibration is “0.0 C”.
ROOM THERMOSTAT HEATING / COOLING MODES
- Your Room Thermostat has heating and cooling modes. To switch easily between heating and cooling modes
- While your device is turned off, press and hold the button for 3 seconds.
- Press the button until the “ ” menu appears.
- You can switch between “ ” (heating) and “ ” (cooling) modes by turning the button to right or left in the “ ” menu.
- To save the settings and exit, press the button until the device turns off.
- The settings you have made have been saved. Once you turn on your device, it will operate with the changed settings.
FACTORY SETTINGS RESET
- You can reset your Room Thermostat to its default factory settings.
- This operation resets the calibration setting and heating/cooling modes to the factory setting. To reset your Room Thermostat to the factory Setting:
- While your device is turned off, press and hold the button for 3 seconds.
- Press the button until the “ ” menu appears.
- While in the “ “ menu, turn the button to the right or left to select the “ “ option and press the button.
- Your device will be turned off and reset to factory settings.
TPI ROOM THERMOSTAT WORKING LOGIC
Your Room Thermostat works with the TPI algorithm. Room Thermostats using TPI
technology predict when the temperature of your home will rise above or below
the set temperature and turn the heating/cooling unit on and off accordingly.
This ensures that your home stays at the temperature you set without maximum
deviations up and down.
What is TPI?
TPI technology is designed to ensure that you get the best possible energy
efficiency from your heating/cooling system. It measures and applies the best
possible timings to deliver and maintain your home at the set temperature
level.
How does TPI work?
Thanks to the advanced artificial intelligence technology found in the
software, it adapts to the temperature change of the environment in which it
is located. By creating a general temperature map of your home, it learns how
long it takes to reach the desired room temperature and how to maintain this
temperature. In this way, it provides minimum energy consumption by
calculating how long your heating/cooling unit should work for.
What is the difference?
In non-TPI room thermostats, the heating/cooling unit works and stops
continuously until it exceeds the set temperature value. If the set
temperature drops below a certain amount, the heating/cooling unit will work
again. This creates greater temperature fluctuations and less energy control.
TPI Room Thermostats, on the other hand, provide higher savings and comfort
compared to On/Off room thermostats with the advantages it has.
Heating Mode
Your room thermostat takes the average room temperature of the last 40 seconds
as the basis. With the TPI algorithm in the product by creating a general
temperature map of your home, it learns how long it takes to reach the desired
room temperature and how this temperature is maintained. Thus, it ensures that
the room temperature remains within a certain range.
Cooling Mode
Your room thermostat takes the average room temperature of the last 40 seconds
as a basis. With the TPI algorithm in the product by creating a general
temperature map of your home, it learns how long it takes to reach the desired
room temperature and how this temperature is maintained. Thus, it ensures that
the room temperature remains within a certain range.
WHAT TO KNOW ABOUT TPI ROOM THERMOSTAT
- If the placement of the TPI Room Thermostats is changed, the learning process will restart. The learning process should be considered as 7 days.
- If the TPI Room Thermostats are de-energized (battery replacement), the learning process will restart. The learning process should be considered as 7 days.
If your heating/cooling unit has on-off connections, your Room thermostat is compatible. You can find information about your heating/cooling unit from your heating/cooling unit operating manual or your heating/cooling unit service. We recommend that the connection between your Room Thermostat and the Heating/Cooling unit should be made by professionally qualified persons. 2×0.75 mm cable is sufficient for the Room Thermostat – heating/cooling unit connection.
Connect one end of the cable pair to the room thermostat connection terminals stated in the user manual of the heating/cooling unit. Connect the other end of the cable pair to COM and NO inputs of the terminal inside the Wall Hanger of the Room Thermostat as shown in the “ROOM THERMOSTAT WIRING DIAGRAM” section. The direction of the cable ends does not matter.
DECLARATION OF CONFORMITY
The Head Office and production site are located on Fatih Mah. 1188 Sk. No:13/ confirms and declares that the product marked with CE and its specifications below is covered by the provisions of the mentioned directive.
Compatible Directives
Electromagnetic Compatibility Regulation 2014/30/EU(EN 61000-6-1:2019, EN
61000-6-3: 2021) Low Voltage Directive 2014/35/EU (EN 60730-2-9) Additional
Information: The mentioned product can be used with heating/cooling units with
on / off output and compliance with the directives only cover the product.
ISIPARK is not responsible for the entire system’s compliance with the
directives. This statement is not valid if changes are made to the product
without our approval.
WARRANTY CONDITIONS
-
The warranty period starts from the invoice date and is warranted against manufacturing defects for 5 years.
-
Devices and apparatus are delivered to the customer in working condition in our company. On-site commissioning is subject to a service fee.
-
The repair of the devices and apparatus covered by the warranty is carried out in our company factory and should be sent by a contracted transportation company.
-
In on-site services, the transportation and accommodation expenses of the service personnel belong to the customer. The shift fee during transportation is added to the service fee and collected in advance.
-
The maintenance of devices and apparatus is done in our company. For the maintenance of the devices and apparatus, the round travel fares belong to the customer.
-
In case of malfunctioning the devices and apparatus whose warranty period continues, it is tested by our company whether the malfunction is caused by a customer or manufacturer fault, and it is reported with a report issued by our company.
-
In case of detection of manufacturer-induced errors of devices and apparatus whose warranty period continues, the customer can request a replacement or repair of the devices and apparatus at full expense by the manufacturer, unless it’s higher than the product’s price.
-
If the faults of the devices and apparatus whose warranty the period continues are determined as caused by the customer, all expenses would belong to the customer.
-
Customers should be aware of damages (if there are any) to the product and warn the manufacturer from the day the warranty duration starts.
-
If customers do not warn the manufacturer with knowledge of the damage, the customer loses the rights of Article 6.
-
Malfunctions resulting from the use of devices and apparatus contrary to the matters stated in the User Manual are not covered by the warranty.
-
Devices and their apparatus are out of warranty if they are beaten, broken or scratched by the customer.
-
Damages resulting from the use of devices and apparatus belonging to other brands and models without the approval of the manufacturer are not covered by the warranty.
-
Battery leakage and errors due to rust, oxidation and liquid contact by working in acidic/humid environments are not covered by the warranty.
-
When the product is not used for a long period (more than 15 days), remove the batteries. Otherwise, malfunctions that will occur are out of warranty.
-
Damages that may occur during the transportation of devices and apparatus are not covered by the warranty. Customers can take transportation insurance.
-
Damages caused by mains voltage / faulty electrical installation are not covered by the warranty. 16- Devices and apparatuses are out of warranty for malfunctions caused by force majeure such as fire, flood, earthquake etc.
-
All of the devices and apparatuses, including all their parts, are under the warranty of our company.
-
In case of malfunction of the devices and apparatuses within the warranty period, the time spent during the repair period is added to the warranty period.
-
The repair period of the product cannot exceed 20 working days.
-
This period starts from the date of notification to the service station of the malfunction related to the product or, in the absence of a service station, to the seller, dealer, agency, representative, importer or manufacturer of the product.
-
Consumers can report the problem by; phone, fax, e-mail, registering and replying to paid letters or a similar way.
-
However, in case of a conflict, the responsibility of proof belongs to the customer.
-
If the malfunction of the product is not repaired within 20 working days, the manufacturer-producer or importer; has to allocate another product with similar features to the use of the consumer until the repair of the product is completed, Although the consumer uses his/her repair rights,
-
If the product breaks down 4 times in a year or 6 times in warranty duration these problems affect the main purpose of the product. (starting from delivery time during warranty.)
-
Exceeding the maximum time required for repair,
-
If the service station is not available, if it is determined that the repair of the defect is not possible with the report prepared (in order) by one of the sellers, dealers, agencies, representatives, importers or manufacturers, a refund or
a price discount at the rate of defect can be requested. -
The customer can make complaints and appeals to consumer courts or consumer arbitration committees.
-
The warranty document must be kept by the customer during the warranty period. If the document is lost, a second document will not be issued. In case of loss, repair and replacement of devices and apparatus will be made for a fee.
WARRANTY CERTIFICATE
Manufacturer
Title: ISIPARK İÇ DIŞ TİC. A.Ş.
Address: Fatih Mah. 1188 Sk. No:13/A Sarnıç
Gaziemir İzmir-TÜRKİYE
Tel: +90 (232) 457 99 50
Fax: +90 (232) 457 91 22
E-mail:
generallife@generallife.com.tr
Product
Type: Digital Room Thermostat
Brand: GENERAL Life
Model: HT220S
Warranty Period: 5 Years
Max. Time to Repair: 20 Days
Bandrol and Serial Number:
SIPARK reserves the right to change product specifications and user manuals. For all changes, you may visit generallife.com.tr
References