inDEM Atecnica GUN 300 Complete Swing Gate Kit Instruction Manual

June 15, 2024
inDEM

inDEM Atecnica GUN 300 Complete Swing Gate Kit

inDEM-Atecnica-GUN-300-Complete-Swing-Gate-Kit-product-
image

Product Information

Specifications

  • Product Name : GUN-V1-20222104
  • Series : GUN
  • Models : 300, 400, 600

Description

  • 1. Swing gate operator
  • 2. Photocell
  • 3. Photocell base
  • 4. Lock
  • 5. Electronic control unit
  • 6. Signal receiver
  • 7. Flashing

Installation
To install the swing gate operator, follow these steps

  1. Fix the operator securely.
  2. Mount the photocell and its base.
  3. Install the lock.
  4. Connect the electronic control unit and the signal receiver.
  5. Attach the flashing light.

Maintenance

The maintenance of the equipment should only be carried out by a specialist technician authorized by the manufacturer. Follow these guidelines for maintenance

  • Ensure that the equipment is powered off before performing any maintenance or control operations.

Technical Data

  • GUN-V1-20222104
  • Series : GUN
  • Models : 300, 400, 600

Frequently Asked Questions (FAQ)

  • Q: Can I install the swing gate operator myself?
    A: It is recommended to have a specialist technician authorized by the manufacturer perform the installation to ensure proper functionality and safety.

  • Q: Can I perform maintenance on the equipment without a specialist technician?
    A: No, the maintenance should only be carried out by a specialist technician authorized by the manufacturer to ensure safety and proper functioning of the equipment.

TERMINOLOGY AND SYMBOLS USED IN THIS MANUAL

  • INSTALLATION AREA : the area required to perform installation in which the presence of persons is hazardous for the persons themselves (Appendix I, 1.1.1 Directive 98/37/EEC).
  • EXPOSED PERSON any person located in full or in part in a hazardous area (Appendix I, 1.1.1 – Directive 98/37/EEC).
  • INSTALLER person responsible for installation, operation, adjustment, maintenance, cleaning, repair and transporting of the device (Appendix I, 1.1.1 – Directive 98/37/EEC).
  • RESIDUAL HAZARD risks which cannot be eliminated or sufficiently reduced as part of the design process.

Warning :This symbol is used to mark information, instructions and procedures which if ignored could lead to death and serious injury and which could create a long-term health and environmental hazard.
Caution : This symbol is used to mark information, instructions and procedures which if ignored can cause serious damage to the machine or to the product.
Information : The symbol is used to mark important information which if ignored could void your warranty.

CE CONFORMITY DECLARATION

  • (machinery Directive 98/37/CE, Attached II, part B)
  • declares that the product:
  • GUN 300-400-600
  • Is suitable with requirement of the Directive 89/392/CEE and next modifications
  • Is suitable with following requirement of other Directives CE
  • 89/336/CEE (electromagnetic compatibility) and next modifications
  • 73/23/CEE (low tension) and next modifications
  • declare moreover that they have been applied the following harmonized norms:
  • EN 292 1/2 – Emergency of the machinery -general principles of planning
  • EN 60335-1 – Emergency of the apparatuses electrical workers of domestic use – general norms
  • EN55014-1 – Conduct Emissions – irradiated power

SAFETY STANDARDS AND INSTALLER OBLIGATIONS

INFORMATION
Installers must proceed as follows to conform with safety standards

  • Wear protective clothing (accident-prevention footwear, goggles, gloves and helmet);

  • Do NOT wear clothing or jewellery that may become trapped (ties, bracelets, necklaces, etc).
    A motorised gate is a machine and as such must be installed in accordance with health and safety standards and legislation. Before installation a risk analysis for the installation site must be performed by professionally qualified personnel in accordance with current legislation for motorised gates (refer to EN 12453 and EN 12445). In countries outside the EU refer to national regulations and legislation as well as the standards specified.

  • Only professionally qualified personnel should install the product.

  • Installation, electrical connections and settings must conform with current legislation.

  • Carefully read the instruction manual before installation

  • Incorrect installation may be a source of hazards

  • Packaging must be disposed of in accordance with current legislation. Do NOT litter the environment

  • Check that the product and packaging are undamaged before starting installation

  • Do NOT install the product in areas where there is a risk of explosion. Gas, powders and flammable fumes represent a health hazard

  • Check that all safety measures are taken and that people are protected from areas posing a risk of crushing, cutting, trapping and any other hazard, in accordance with current legislation for motorised gates

  • The installation area must be cordoned off to prevent access by unauthorised personnel

  • Protection devices must be installed following risk analysis of the site. Check that the protection devices are marked and that they function in accordance with current legislation

  • The data required by applicable legislation must be clearly visible on the installation

  • Check that the mains power available is compatible with the data on the identification plate before connecting the operator to the mains power supply. A suitable differential overload switch must be installed upstream of the operator

  • The manufacturer of the operator declines all responsibility if components are used which are incompatible with correct and safe use.

  • The installer must provide the user with all the information need to operate the device with particular attention given to manual operation in the event of an emergency and any residual risks.

WARNINGS FOR THE USER

  • The instructions and warnings given below are a vital and integral part of the product. The instructions and warnings must be given to the user and then read carefully because they include important warnings for use and maintenance. The instructions must be kept and given to all future users.
  • The operator must be used exclusively for the purpose for which it is designed. All improper use is forbidden and hazardous.
  • Keep away from moving mechanical parts. Keep away from the operating range of the device during operation. Do not try to obstruct the movement of the device as such action may be hazardous.
  • Keep children away from the operating range of the device at all times.
  • Keep remote control and other control units in a safe place to prevent use by children or unauthorized people.
  • In the event of any faults disconnect the operator from the mains power supply using the main switch. Do not try to repair the main unit. Contact the installer or other specialist assistance centre. Failure to follow these instructions may result in hazardous situations.
  • All maintenance, including cleaning, must be performed by qualified personnel.
  • Follow the manufacturer’s instructions and refer to specialist personnel to perform routine maintenance, particularly verification of correct functioning of protection devices, to ensure correct and efficient functioning of the operator.
  • All repairs and maintenance must be recorded on the maintenance record and then made available to the user.

INSTALLATION

GUN OPERATOR MOUNTING

  • The GUN operator has been made in RIGHT and/or LEFT version depending on the leaf on which it will be installed. The leaves must be considered from the internal side (garden).
  • The GUN operator is easily installed on any type of gate, as long as the gate is well balanced.
  • The GUN operator has been constructed for gate wings that do not exceed 350 kg in weight and 3,5 meters in length.
  • Fix the large plate to the column respecting the measurements shown in the table and position the cylinder perfectly horizontal (check with a sprit-level) and with respect to Its axis (Fig. A).
  • Fix the gear-motor to the large plate “1” using the pin and grub-screw supplied.
  • GUN OPERATOR MOUNTING Completely extend the stainless steel tube “ 3 ” up to the end of its stroke, then screw it back for one turn (at least 1 cm) to make the gate wing close perfectly.
  • Fix the small plate “ 4 ” to the end of the operator using the pin and grub-screw supplied. Fix the small plate to the gate wing, keeping the operator horizontal (check with a sprit-level).
  • Position the mechanical doorstops in both the open and closed positions (Fig. B).
  • MANUAL OR EMERGENCY MANOEUVRE: Operate unlocking device “ 2 ” using the key supplied.

inDEM-Atecnica-GUN-300-Complete-Swing-Gate-Kit-image04 inDEM-Atecnica-GUN-300-Complete-Swing-Gate-Kit-
image05

 TECHNICAL DATA

  • Power supply: 230 Vac
  • Absorbed power: 180 W
  • Absorbed current: 1,3A
  • Rod speed: 1,8 cm/s
  • Usable stroke: 300-400-600 mm
  • Maximum length per lea: 3 m
  • Maximum weight per leaf :350 Kg
  • Housing protection :IP 44
  • Termic  Protection : 150°
  • Cycles/h : 18
  • Operating temperature :-45°C ÷ +70°C
  • Lubrification : permanent grease
  • Capacitor :10pF
  • Motor Weight :6 Kg

SYSTEM DIAGRAM

inDEM-Atecnica-GUN-300-Complete-Swing-Gate-Kit-image07

DESCRIPTION
1 Swing gate operator
2 Photocell
3 Photocell base
4 Lock
5 Electronic control unit
6 Signal receiver
7 Flashing

MAINTENANCE

Warning : The maintenance of the equipment shall be carried out only by a specialist technician and authorized by the manufacturer. Any operation of the maintenance or control of the equipment shall be carried out in the absence of voltage.

  • Ordinary maintenance: every time you need for it, and in any event every 6 months, it is recommended to check the functioning of the equipment.
  • Extraordinary maintenance: if may be necessary major interventions on the equipment, it is recommended that the removal of the same, to allow the repair in the laboratory by technicians on the manufacturer or authorized.

The manufacturer is raised from any liability for the failure to comply with the rules described above.

CABLES CONNECTION

CABLES FUNCTION REFERENCE TABLE

Cable colour “D” right gate operator “S” left gate operator
Gray Common Common
Black Pull Piston rod (Opening) Pull back Piston rod (Closing)
Brown Pull back Piston rod (Closing) Pull Piston rod (Opening)
Yellow-Green Ground Ground

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals