Gibson KG7S Gas Furnace Owner’s Manual
- June 15, 2024
- Gibson
Table of Contents
- Gibson KG7S Gas Furnace
- Product Information
- Product Usage Instructions
- WARRANTY
- FEATURES and BENEFITS
- GAS FURNACE COMPONENTS
- DIMENSIONS
- BLOWER PERFORMANCE
- MODEL IDENTIFICATION CODE
- SPECIFICATIONS
- ACCESSORIES
- GENERAL TERMS OF LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Gibson KG7S Gas Furnace
Product Information
Technical Specifications
- Product Name: KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces
- Induced Draft – 80+ AFUE Input 45,000 – 126,000 Btuh
- Installation: Freestanding in a utility room, basement, or enclosed in an alcove or closet
- Rounded corner jacket for a pleasing appliance appearance
- Design certified by CSA for application in the United States and Canada
Warranty
The product comes with a warranty. Please refer to the warranty documentation
for more details.
Features and Benefits
- Dent-free design for product durability
- Compatible with taller high SEER coils for easier handling
- Adjustable blower duct temperature at furnace start-up
- Appliance-type ignitor with a 20-year history of reliability
- Quick-connect fittings for ease of installation
- Increases cooling performance when matched with a wide range of cooling capacities
- Switches on PCB for easy troubleshooting: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes
- Captured screws to prevent losing door screws
Gas Furnace Components
Upflow/Horizontal Gas Furnace
- Main Air Limit Switch
- Inducer Assembly
- Transformer Igniter
- Blower Door Switch
- Roll-Out Switch
- Blower Assembly (behind blower panel)
- Control Board
- Gas Valve
- Pressure Switch
- Flame Sensor
- Gas Manifold
- Burner Assembly
Downflow Gas Furnace
- Main Air Limit Switch
- Inducer Assembly
- Transformer Igniter
- Blower Door Switch
- Roll-Out Switch
- Blower Assembly
- Control Board
- Gas Valve
- Pressure Switch
- Flame Sensor
- Gas Manifold
- Burner Assembly
Dimensions
K7SA Series
A | B | C | D |
---|---|---|---|
12″ | 12″ | 15″ | 16″ |
21″ | 14″ | 19″ | 22″ |
K7SK Series
A | B | C | D |
---|---|---|---|
12″ | 12″ | 15″ | 16″ |
19″ | 22″ | 23″ | 25″ |
Blower Performance – KG7SA
Model Number| Heating Input (Btuh)| Motor Speed| External Static Pressure
(Inches Water Column)| CFM Rise
---|---|---|---|---
SA045( )-23A Bottom Return| 45,000| High*| 0.1| 1260 CFM Rise
Product Usage Instructions
Installation
The high-efficiency gas furnace may be installed free-standing in a utility
room, or basement, or enclosed in an alcove or closet. Ensure proper
ventilation and follow all local building codes and regulations.
Maintenance
Regular maintenance is important to ensure the optimal performance of the gas
furnace. Refer to the user manual for detailed maintenance instructions.
Troubleshooting
If you encounter any issues with the gas furnace, refer to the troubleshooting
section of the user manual. If the issue persists, contact customer support
for further assistance.
FAQ
-
Q: Where can I install the gas furnace?
A: The gas furnace can be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet. -
Q: Is the gas furnace compatible with high SEER coils?
A: Yes, the gas furnace works well with taller high SEER coils for easier handling. -
Q: How can I increase cooling performance with the gas furnace?
A: The gas furnace can increase cooling performance when matched with a wide range of cooling capacities. Consult the user manual for more information.
KG7S (A and K Series)
High-Efficiency Upflow/Horizontal and Downflow Gas Furnaces
- Induced Draft – 80+ AFUE
- Input 45,000 – 126,000 Btuh
The high-efficiency gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in the United States and Canada.
WARRANTY
- 10-year all-parts warranty.
- 1 Year Quality Pledge to replace the unit if the heat exchanger fails within the first year of operation, to the original owner.
- Consumer product registration is required for 10 year All Parts Warranty and Quality Pledge within a limited time after the installation. See the current warranty document or visit our consumer website listed on the back of this document for warranty details.
- When registered, this product is upgraded to a limited lifetime heat exchanger warranty.
FEATURES and BENEFITS
- 100% fired and tested: All units and each component are tested on the manufacturing line.
- Best packaging in the industry: Unique corner post design assures the product will arrive to the homeowner dent-free.
- Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
- Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
- 30-second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
- 30-second post purge: Increases life of heat exchanger.
- Hot surface ignitor: Innovative application of an appliance-type ignitor with a 20-year history of reliability. Utilizes proven Smartlite® technology.
- Color-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
- High static blowers: All models are equipped with high static blowers.
- 90-second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
- Flexible category I venting system: This may be vented with the dedicated venting system or commonly vented with other category one appliances.
- High-efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
- Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra-easy motor speed selection.
- LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
- Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
- Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
- Two-piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.
GAS FURNACE COMPONENTS
DIMENSIONS
*SA Model #’s| Dimension “A”| Dimension “B”|
Dimension “C”| Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| ****
21
| ****
14
| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8
BLOWER PERFORMANCE
KG7SA
Model Number| Heating Input (Btuh)| Motor Speed| External
Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
SA045( )-23A
Bottom Return
| ****
45,000
| High* Med-High
Med-Low** Low
| 1260
955
825
655
| 26
35
40
51
| 1205
950
800
630
| 28
35
42
53
| 1145
940
760
610
| 29
35
44
55
| 1080
935
730
580
| 31
36
46
| 1025
925
690
550
| 33
36
48
| 960
860
650
520
| 35
39
51
| 890
800
600
480
| 37
42
| 825
725
530
435
| 40
46
|
56
69
| 63
77
|
57| 61| 64|
SA045( )-23A
Side Return
| ****
45,000
| High* Med-High
Med-Low** Low
| 1350
1025
885
700
| 25
33
38
48
| 1290
1015
855
675
| 26
33
39
49
| 1225
1005
815
655
| 27
33
41
51
| 1155
1000
780
620
| 29
33
43
| 1100
990
740
590
| 30
34
45
| 1025
920
695
555
| 33
36
48
| 950
855
640
515
| 35
39
52
| 885
775
565
465
| 38
43
|
59
72
|
54| 56| 60| 65|
SA054( )-23A
Bottom Return
| ****
54,000
| High* Med-High
Med-Low** Low
| 1260
955
825
655
| 32
42
48
| 1205
950
800
630
| 33
42
50
| 1145
940
760
610
| 35
43
53
| 1080
935
730
580
| 37
43
55
| 1025
925
690
550
| 39
43
| 960
860
650
520
| 42
47
| 890
800
600
480
| 45
50
| 825
725
530
435
| 48
55
|
58
73
| 62
77
| 67
83
| 75
92
|
61| 63| 66| 69|
SA054( )-23A
Side Return
| ****
54,000
| High* Med-High
Med-Low** Low
| 1350
1025
885
700
| 30
39
45
| 1290
1015
855
675
| 31
39
47
| 1225
1005
815
655
| 33
40
49
| 1155
1000
780
620
| 35
40
51
| 1100
990
740
590
| 36
40
54
| 1025
920
695
555
| 39
43
| 950
855
640
515
| 42
47
| 885
775
565
465
| 45
52
|
58
72
| 63
78
| 71
86
|
57| 59| 61| 65| 68|
SA072( )-24B
Bottom Return
| ****
72,000
| High* Med-High
Med-Low** Low
| 1685
1330
1175
930
| 32
40
45
57
| 1640
1295
1155
895
| 33
41
46
60
| 1605
1275
1125
885
| 33
42
47
60
| 1565
1245
1100
850
| 34
43
48
| 1515
1215
1075
825
| 35
44
50
| 1475
1185
1045
800
| 36
45
51
| 1415
1135
1010
770
| 38
47
53
| 1345
1070
955
740
| 40
50
56
|
63| 65| 67| 69| 72|
SA072( )-24B
Side Return
| ****
72,000
| High* Med-High
Med-Low** Low
| 1770
1400
1235
975
| 30
38
43
55
| 1720
1360
1215
940
| 31
39
44
57
| 1685
1340
1180
930
| 32
40
45
57
| 1645
1310
1155
890
| 32
41
46
60
| 1590
1275
1130
865
| 34
42
47
| 1550
1245
1100
840
| 34
43
48
| 1485
1190
1060
810
| 36
45
50
| 1415
1125
1005
775
| 38
47
53
|
62| 63| 66| 69|
SA090( )-24B
Bottom Return
| ****
90,000
| High*
Med-High** Med-Low Low
| 1610
1295
1155
880
| 41
51
58
| 1575
1260
1130
860
| 42
53
59
| 1530
1235
1100
830
| 44
54
61
| 1485
1220
1070
800
| 45
55
| 1440
1175
1035
765
| 46
57
| 1385
1135
1015
740
| 48
59
| 1340
1095
965
675
| 50| 1275
1015
920
660
| 52|
61| 66|
62
83
| 64
87
| 66
90
| 69| 72|
76| 78| 80| 99| 101|
SA090( )-24B
Side Return
| ****
90,000
| High*
Med-High** Med-Low Low
| 1690
1360
1215
925
| 39
49
55
| 1655
1325
1190
900
| 40
50
56
| 1610
1300
1155
870
| 41
51
58
| 1560
1280
1125
840
| 43
52
59
| 1510
1235
1090
800
| 44
54
| 1455
1190
1065
775
| 46
56
| 1405
1150
1015
710
| 47
58
| 1340
1065
965
695
| 50|
63|
61| 63
86
| 66
94
| 69|
72| 74| 77| 79| 83| 96|
SA072( )-35C
Bottom Return
| ****
72,000
| High* Med-High
Med-Low** Low
| 1950
1860
1300
1165
| 27| 1865
1780
1240
1115
| 29| 1790
1710
1200
1060
| 30| 1715
1635
1160
1025
| 31| 1630
1575
1120
985
| 33| 1550
1500
1065
940
| 34| 1475
1415
995
890
| 36
38
54
60
| 1390
1325
910
825
| 38
40
59
65
|
29| 30| 31| 33| 34| 36
50
57
|
41
46
| 43
48
| 44
50
| 46
52
| 48
54
|
SA072( )-35C
Side Return
| ****
72,000
| High* Med-High
Med-Low** Low
| 2030
1935
1350
1215
| 26
28
| 1940
1850
1290
1160
| 27
29
| 1860
1780
1250
1105
| 29
30
| 1785
1700
1205
1065
| 30
31
| 1695
1340
1165
1025
| 31| 1615
1560
1110
980
| 33
34
| 1535
1470
1035
925
| 35
36
52
58
| 1445
1380
945
860
| 37
39
56
62
|
40
46
52
|
40
44
| 41
46
| 43
48
| 44
50
| 48
54
|
Model Number| Heating Input (Btuh)| Motor Speed| External
Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7|
0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise|
SA072( )-35C
Side + Bottom or 2 Sides
| ****
72,000
| High* Med-High
Med-Low** Low
| 2050
1955
1365
1225
| 26
27
| 1960
1870
1300
1170
| 27
29
| 1880
1800
1260
1115
| 28
30
| 1800
1715
1220
1075
| 30
31
| 1710
1655
1175
1035
| 31
32
| 1630
1575
1120
985
| 33
34
| 1550
1485
1045
935
| 34| 1460
1390
955
865
| 37
38
56
62
|
36
51
57
|
39
44
| 41
46
| 42
48
| 44
50
| 45
52
| 48
54
|
SA090( )-35C
Bottom Return
| ****
90,000
| High*
Med-High** Med-Low Low
| 1940
1820
1290
1145
| 34| 1860
1760
1245
1110
| 36
38
54
60
| 1790
1695
1200
1070
| 37
39
56
62
| 1710
1620
1155
1035
| 39
41
58
64
| 1625
1545
1110
1000
| 41
43
60
| 1540
1466
1060
950
| 43
45
63
| 1450
1380
995
905
| 46
48
| 1355
1280
915
835
| 49
52
|
37
52
58
|
67| 73|
67| 70| 74| 80|
SA090( )-35C
Side Return
| ****
90,000
| High*
Med-High** Med-Low Low
| 2020
1895
1345
1190
| 33| 1935
1830
1295
1155
| 34| 1860
1765
1250
1115
| 36
38
53
60
| 1780
1685
1200
1075
| 37
40
56
62
| 1690
1610
1155
1040
| 39
41
58
64
| 1600
1525
1100
980
| 42
44
61
| 1510
1435
1035
940
| 44
46
64
| 1410
1330
950
870
| 47
50
|
35
50
56
| 36
51
58
|
70|
68| 71| 77|
SA090( )-35C
Side + Bottom or 2 Sides
| ****
90,000
| High*
Med-High** Med-Low
Low
| 2040
1910
1355
1205
| 33| 1955
1850
1310
1165
| 34| 1880
1780
1260
1125
| 35
37
53
59
| 1795
1700
1215
1085
| 37
39
55
61
| 1705
1625
1165
1050
| 39
41
57
63
| 1620
1540
1115
1000
| 41
43
60
| 1525
1450
1050
950
| 44
46
63
| 1425
1345
960
875
| 47
50
|
35
49
55
| 36
51
57
|
69|
67| 70| 76|
SA108( )-35C
Bottom Return
| ****
108,000
| High*
Med-High** Med-Low Low
| 2205
2050
1700
1390
| 36
39
47
58
| 2150
1995
1680
1370
| 37
40
48
58
| 2095
1955
1645
1355
| 38
41
49
59
| 2030
1895
1610
1320
| 39
42
50
61
| 1970
1840
1565
1300
| 41
43
51
62
| 1900
1775
1525
1270
| 42
45
52
63
| 1830
1700
1460
1225
| 44
47
55
65
| 1740
1610
1375
1175
| 46
50
58
|
68|
SA108( )-35C
Side Return
| ****
108,000
| High*
Med-High** Med-Low Low
| 2295
2130
1770
1445
| 35
38
45
55
| 2235
2075
1750
1425
| 36
39
46
56
| 2180
2035
1710
1410
| 37
39
47
57
| 2110
1970
1675
1375
| 38
41
48
58
| 2050
1915
1630
1350
| 39
42
49
59
| 1975
1845
1585
1320
| 41
43
50
61
| 1900
1765
1520
1275
| 42
45
53
63
| 1810
1675
1430
1225
| 44
48
56
65
|
SA108( )-35C
Side + Bottom or 2 Sides
| ****
108,000
| High*
Med-High** Med-Low
Low
| 2315
2155
1785
1460
| 35
37
45
55
| 2260
2095
1765
1440
| 35
38
45
56
| 2200
2055
1725
1425
| 36
39
46
56
| 2130
1990
1690
1385
| 38
40
47
58
| 2070
1930
1645
1365
| 39
41
49
59
| 1995
1865
1600
1335
| 40
43
50
60
| 1925
1785
1535
1285
| 42
45
52
62
| 1825
1690
1445
1235
| 44
47
55
65
|
SA126( )-45D
Bottom only or 2 openings
| ****
126,000
| High*
Med-High** Med-Low
Low
| 2255
2075
1720
1360
| 41
45
54
69
| 2200
2025
1695
1375
| 42
46
55
68
| 2125
1970
1655
1365
| 44
47
56
68
| 2065
1940
1630
1315
| 45
48
57
| 2010
1875
1580
1310
| 46
50
59
| 1935
1810
1520
1300
| 48
52
61
| 1855
1750
1455
1260
| 50
53
64
| 1755
1680
1390
1230
| 53
56
67
|
71| 71| 72| 74| 76|
SA126( )-45D
Side Return
| ****
126,000
| High*
Med-High** Med-Low Low
| 2230
2055
1705
1345
| 42
45
55
69
| 2180
2005
1680
1360
| 43
47
56
69
| 2105
1950
1640
1350
| 44
48
57
69
| 2045
1920
1615
1300
| 46
49
58
| 1990
1855
1565
1230
| 47
50
60
| 1915
1790
1505
1290
| 49
52
62
| 1835
1735
1440
1250
| 51
54
65
| 1740
1665
1375
1220
| 54
56
68
|
72| 76| 72| 75| 77|
- ( ) Can be C or N
-
- Factory Set Cooling Speed
- ** Factory Set Heating Speed
NOTES:
- Two openings are recommended for airflows above 1600 CFM if filter(s) is(are) adjacent to the furnace.
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are for reference only. These conditions are not recommended.
KG7SK
Model Number| Heating Input (Btuh)| Motor Speed| External
Static Pressure (Inches Water Column)
---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| Rise| CFM| Rise| CFM| Rise| CFM|
Rise| CFM| Rise| CFM| Rise| CFM| Rise|
CFM| Rise
SK054( )-23A
|
54,000
| High* Med-High
Med-Low** Low
| 1375
1155
790
650
| 29
35
51
| 1340
1130
775
640
| 30
35
52
| 1300
1110
765
630
| 31
36
52
| 1270
1085
750
610
| 31
37
53
| 1225
1055
730
590
| 33
38
55
| 1175
1015
700
565
| 34
39
| 1115
975
665
530
| 36
41
| 1035
910
610
480
| 39
44
57| 60| 66
62| 63| 63| 66| 68| 71| 75| 83
SK072( )-24B
|
72,000
| High* Med-High
Med-Low** Low
| 1610
1295
1155
910
| 33
41
46
59
| 1590
1275
1135
885
| 34
42
47
60
| 1575
1260
1115
860
| 34
42
48
| 1560
1250
1095
835
| 34
43
49
| 1540
1220
1065
810
| 35
44
50
| 1495
1195
1040
785
| 36
45
51
| 1460
1170
1015
765
| 37
46
53
| 1415
1120
980
735
| 38
48
54
62| 64| 66| 68| 70| 73
SK090( )-24B
|
90,000
| High* Med-High
Med-Low** Low
| 1675
1330
1180
940
| 40
50
56
| 1655
1315
1165
925
| 40
51
57
| 1640
1300
1150
900
| 41
51
58
| 1620
1280
1135
880
| 41
52
59
| 1590
1255
1115
850
| 42
53
60
| 1560
1230
1090
825
| 43
54
61
| 1520
1200
1060
795
| 44
56
63
| 1475
1150
1010
760
| 45
58
66
71| 72| 74| 76| 78| 81| 84| 88
SK108( )-35C
|
108,000
| High* Med-High
Med-Low** Low
| 2395
2190
1785
1145
| 33
37
45
| 2335
2135
1770
1110
| 34
37
45
| 2285
2115
1740
1070
| 35
38
46
| 2230
2080
1725
1035
| 36
38
46
| 2200
2030
1685
1000
| 36
39
47
| 2140
1975
1645
950
| 37
41
49
| 2080
1915
1615
905
| 38
42
50
| 2000
1810
1565
835
| 40
44
51
70| 72| 75| 77| 80| 84| 88| 96
SK126( )-45D
|
126,000
| High* Med-High
Med-Low** Low
| 2445
2195
1795
1480
| 38
43
52
63
| 2395
2170
1780
1475
| 39
43
52
63
| 2385
2140
1770
1450
| 39
44
53
64
| 2330
2120
1760
1440
| 40
44
53
65
| 2275
2090
1725
1440
| 41
45
54
65
| 2225
2030
1690
1415
| 42
46
55
| 2130
1975
1655
1405
| 44
47
56
| 2015
1855
1610
1375
| 46
50
58
66| 66| 68
- ( ) Can be C or N
-
- Factory Set Cooling Speed
- ** Factory Set Heating Speed
NOTES:
- Temperature rises in the table are approximate. Actual temperature rises may vary.
- Temperature rises shaded in gray are for reference only. These conditions are not recommended.
MODEL IDENTIFICATION CODE
SPECIFICATIONS
KG7SA MODEL NUMBERS| -045-23A| -054-23A| -072-24B| -090-24B| -072-35C|
-090-35C| -108-35C| -126-45D
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 54,000| 72,000| 90,000| 72,000| 90,000| 108,000|
126,000
Heating Capacity – Btuh| 36,000| 43,200| 57,600| 72,000| 57,600| 72,000|
86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 10 x 6| 11 x 8| 11 x 8| 10 x 10| 10 x 10| 11 x 10| 11 x
10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 –
4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1.0 – 4 – PSC| 1.0 – 4 – PSC
Motor FLA| 4.80| 4.80| 8.20| 8.20| 7.50| 7.50| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70|
40-70
Shipping Weights| 100lbs| 100lbs| 110lbs| 115lbs| 115lbs| 120lbs| 125lbs|
145lbs
KG7SK MODEL NUMBERS| -054-23A| -072-24B| -090-24B| -108-35C| -126-45D
---|---|---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 43,200| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 11 x 8| 11 x 8| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 3/4 –
4 – PSC| 1.0 – 4 -PSC
Motor FLA| 4.80| 8.20| 8.20| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 110lbs| 115lbs| 125lbs| 145lbs
ACCESSORIES
KG7S (A, K) KITS
Description| SKU
“A” Cabinet fixed speed, high efficiency, FSHE| 904872
“B” Cabinet fixed speed, high efficiency, FSHE| 904873
“C” Cabinet fixed speed, high efficiency, FSHE| 904874
“D” Cabinet fixed speed, high efficiency, FSHE| 904875
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.)| 904914
Canada LP Conversion kit (0 to 4,500 ft.)| 904915
Bottom return filter 20 per box, “A” cabinet| 903088
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036
GENERAL TERMS OF LIMITED WARRANTY
- NORDYNE will furnish a replacement for any part of this product that fails in normal use and service within the first ten years of installation, per the terms of the warranty.
- For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.
8000 Phoenix Parkway | O’Fallon, MO 63368-3827 Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in U.S.A (02/2011) 739C-0211 (Replaces 739C-0608).
GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved. www.gibsonhvac.com.