Gibson KG7S Gas Furnace Owner’s Manual

June 15, 2024
Gibson

Gibson KG7S Gas Furnace

Gibson-KG7S-Gas-Furnace-product

Product Information

Technical Specifications

  • Product Name: KG7S (A and K Series) High Efficiency Upflow/Horizontal and Downflow Gas Furnaces
  • Induced Draft – 80+ AFUE Input 45,000 – 126,000 Btuh
  • Installation: Freestanding in a utility room, basement, or enclosed in an alcove or closet
  • Rounded corner jacket for a pleasing appliance appearance
  • Design certified by CSA for application in the United States and Canada

Warranty
The product comes with a warranty. Please refer to the warranty documentation for more details.

Features and Benefits

  • Dent-free design for product durability
  • Compatible with taller high SEER coils for easier handling
  • Adjustable blower duct temperature at furnace start-up
  • Appliance-type ignitor with a 20-year history of reliability
  • Quick-connect fittings for ease of installation
  • Increases cooling performance when matched with a wide range of cooling capacities
  • Switches on PCB for easy troubleshooting: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes
  • Captured screws to prevent losing door screws

Gas Furnace Components

Upflow/Horizontal Gas Furnace

  • Main Air Limit Switch
  • Inducer Assembly
  • Transformer Igniter
  • Blower Door Switch
  • Roll-Out Switch
  • Blower Assembly (behind blower panel)
  • Control Board
  • Gas Valve
  • Pressure Switch
  • Flame Sensor
  • Gas Manifold
  • Burner Assembly

Downflow Gas Furnace

  • Main Air Limit Switch
  • Inducer Assembly
  • Transformer Igniter
  • Blower Door Switch
  • Roll-Out Switch
  • Blower Assembly
  • Control Board
  • Gas Valve
  • Pressure Switch
  • Flame Sensor
  • Gas Manifold
  • Burner Assembly

Dimensions

K7SA Series

A B C D
12″ 12″ 15″ 16″
21″ 14″ 19″ 22″

K7SK Series

A B C D
12″ 12″ 15″ 16″
19″ 22″ 23″ 25″

Blower Performance – KG7SA

Model Number| Heating Input (Btuh)| Motor Speed| External Static Pressure (Inches Water Column)| CFM Rise
---|---|---|---|---
SA045( )-23A Bottom Return| 45,000| High*| 0.1| 1260 CFM Rise

Product Usage Instructions

Installation
The high-efficiency gas furnace may be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet. Ensure proper ventilation and follow all local building codes and regulations.

Maintenance
Regular maintenance is important to ensure the optimal performance of the gas furnace. Refer to the user manual for detailed maintenance instructions.

Troubleshooting
If you encounter any issues with the gas furnace, refer to the troubleshooting section of the user manual. If the issue persists, contact customer support for further assistance.

FAQ

  • Q: Where can I install the gas furnace?
    A: The gas furnace can be installed free-standing in a utility room, or basement, or enclosed in an alcove or closet.

  • Q: Is the gas furnace compatible with high SEER coils?
    A: Yes, the gas furnace works well with taller high SEER coils for easier handling.

  • Q: How can I increase cooling performance with the gas furnace?
    A: The gas furnace can increase cooling performance when matched with a wide range of cooling capacities. Consult the user manual for more information.

KG7S (A and K Series)
High-Efficiency Upflow/Horizontal and Downflow Gas Furnaces

  • Induced Draft – 80+ AFUE
  • Input 45,000 – 126,000 Btuh

The high-efficiency gas furnace may be installed free-standing in a utility room, basement, or enclosed in an alcove or closet. The rounded corner jacket provides a pleasing “appliance appearance.” Design certified by CSA for application in the United States and Canada.

WARRANTY

  • 10-year all-parts warranty.
  • 1 Year Quality Pledge to replace the unit if the heat exchanger fails within the first year of operation, to the original owner.
  • Consumer product registration is required for 10 year All Parts Warranty and Quality Pledge within a limited time after the installation. See the current warranty document or visit our consumer website listed on the back of this document for warranty details.
  • When registered, this product is upgraded to a limited lifetime heat exchanger warranty.

FEATURES and BENEFITS

  • 100% fired and tested: All units and each component are tested on the manufacturing line.
  • Best packaging in the industry: Unique corner post design assures the product will arrive to the homeowner dent-free.
  • Low Boy Height: Easy to apply in low ceiling applications, works well with taller high SEER coils, easier to handle and install.
  • Tubular primary heat exchanger: Heavy gauge aluminized steel heat exchanger assures a long life.
  • 30-second blower delay at start-up: Assures a warm duct temperature at furnace start-up. Adjustable blower-off settings (60, 90, 120 and 180 seconds).
  • 30-second post purge: Increases life of heat exchanger.
  • Hot surface ignitor: Innovative application of an appliance-type ignitor with a 20-year history of reliability. Utilizes proven Smartlite® technology.
  • Color-coded wire harness: Designed to fit the components, all with quick-connect fittings for ease of service and replacement.
  • High static blowers: All models are equipped with high static blowers.
  • 90-second cooling cycle blower-off delay (TDR): increases cooling performance when matched with a NORDYNE coil.
  • Flexible category I venting system: This may be vented with the dedicated venting system or commonly vented with other category one appliances.
  • High-efficiency blower kits: Maximize efficiencies. On select units, a SEER improvement of up to 1 point is realized.
  • Multi-speed direct drive blower: Designed to give a wide range of cooling capacities. Switches on PCB, provide ultra-easy motor speed selection.
  • LP convertible: Simple burner orifice and regulator spring change for ease of convertibility.
  • Diagnostic lights for easy troubleshooting without counting flashes: Dedicated light for flame signal strength and 2 lights in combination to indicate all other fault codes with easy-to-recognize states without counting flashes.
  • Integrated control board: Incorporates connections for electronic air cleaner and humidifier.
  • Two-piece door design: Enhances furnace appearance and uses captured screws to prevent losing door screws.

GAS FURNACE COMPONENTS

Gibson-KG7S-Gas-Furnace-fig- \(1\) Gibson-KG7S-Gas-
Furnace-fig- \(2\)

DIMENSIONS

*SA Model #’s| Dimension “A”| Dimension “B”| Dimension “C”| Dimension “D”
---|---|---|---|---
045-23A| 14 1/4| 10 3/4| 12 5/8| 12 7/8
054-23A
072-24B| 17 1/2| 11 3/4| 15 7/8| 16 1/8
090-24B
072-35C| ****

21

| ****

14

| 19 3/8| 19 7/8
090-35C
108-35C
126-45D| 24 1/2| 15 1/4| 22 7/8| 23 1/8

Gibson-KG7S-Gas-Furnace-fig- \(3\) Gibson-KG7S-Gas-
Furnace-fig- \(4\)

BLOWER PERFORMANCE

KG7SA

Model Number| Heating Input (Btuh)| Motor Speed| External Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise|


SA045( )-23A

Bottom Return

| ****

45,000

| High* Med-High

Med-Low** Low

| 1260

955

825

655

| 26

35

40

51

| 1205

950

800

630

| 28

35

42

53

| 1145

940

760

610

| 29

35

44

55

| 1080

935

730

580

| 31

36

46

| 1025

925

690

550

| 33

36

48

| 960

860

650

520

| 35

39

51

| 890

800

600

480

| 37

42

| 825

725

530

435

| 40

46

|
56

69

| 63

77

|
57| 61| 64|


SA045( )-23A

Side Return

| ****

45,000

| High* Med-High

Med-Low** Low

| 1350

1025

885

700

| 25

33

38

48

| 1290

1015

855

675

| 26

33

39

49

| 1225

1005

815

655

| 27

33

41

51

| 1155

1000

780

620

| 29

33

43

| 1100

990

740

590

| 30

34

45

| 1025

920

695

555

| 33

36

48

| 950

855

640

515

| 35

39

52

| 885

775

565

465

| 38

43

|
59

72

|
54| 56| 60| 65|


SA054( )-23A

Bottom Return

| ****

54,000

| High* Med-High

Med-Low** Low

| 1260

955

825

655

| 32

42

48

| 1205

950

800

630

| 33

42

50

| 1145

940

760

610

| 35

43

53

| 1080

935

730

580

| 37

43

55

| 1025

925

690

550

| 39

43

| 960

860

650

520

| 42

47

| 890

800

600

480

| 45

50

| 825

725

530

435

| 48

55

|
58

73

| 62

77

| 67

83

| 75

92

|
61| 63| 66| 69|


SA054( )-23A

Side Return

| ****

54,000

| High* Med-High

Med-Low** Low

| 1350

1025

885

700

| 30

39

45

| 1290

1015

855

675

| 31

39

47

| 1225

1005

815

655

| 33

40

49

| 1155

1000

780

620

| 35

40

51

| 1100

990

740

590

| 36

40

54

| 1025

920

695

555

| 39

43

| 950

855

640

515

| 42

47

| 885

775

565

465

| 45

52

|
58

72

| 63

78

| 71

86

|
57| 59| 61| 65| 68|


SA072( )-24B

Bottom Return

| ****

72,000

| High* Med-High

Med-Low** Low

| 1685

1330

1175

930

| 32

40

45

57

| 1640

1295

1155

895

| 33

41

46

60

| 1605

1275

1125

885

| 33

42

47

60

| 1565

1245

1100

850

| 34

43

48

| 1515

1215

1075

825

| 35

44

50

| 1475

1185

1045

800

| 36

45

51

| 1415

1135

1010

770

| 38

47

53

| 1345

1070

955

740

| 40

50

56

|
63| 65| 67| 69| 72|


SA072( )-24B

Side Return

| ****

72,000

| High* Med-High

Med-Low** Low

| 1770

1400

1235

975

| 30

38

43

55

| 1720

1360

1215

940

| 31

39

44

57

| 1685

1340

1180

930

| 32

40

45

57

| 1645

1310

1155

890

| 32

41

46

60

| 1590

1275

1130

865

| 34

42

47

| 1550

1245

1100

840

| 34

43

48

| 1485

1190

1060

810

| 36

45

50

| 1415

1125

1005

775

| 38

47

53

|
62| 63| 66| 69|


SA090( )-24B

Bottom Return

| ****

90,000

| High*

Med-High** Med-Low Low

| 1610

1295

1155

880

| 41

51

58

| 1575

1260

1130

860

| 42

53

59

| 1530

1235

1100

830

| 44

54

61

| 1485

1220

1070

800

| 45

55

| 1440

1175

1035

765

| 46

57

| 1385

1135

1015

740

| 48

59

| 1340

1095

965

675

| 50| 1275

1015

920

660

| 52|
61| 66|
62

83

| 64

87

| 66

90

| 69| 72|
76| 78| 80| 99| 101|


SA090( )-24B

Side Return

| ****

90,000

| High*

Med-High** Med-Low Low

| 1690

1360

1215

925

| 39

49

55

| 1655

1325

1190

900

| 40

50

56

| 1610

1300

1155

870

| 41

51

58

| 1560

1280

1125

840

| 43

52

59

| 1510

1235

1090

800

| 44

54

| 1455

1190

1065

775

| 46

56

| 1405

1150

1015

710

| 47

58

| 1340

1065

965

695

| 50|
63|
61| 63

86

| 66

94

| 69|
72| 74| 77| 79| 83| 96|


SA072( )-35C

Bottom Return

| ****

72,000

| High* Med-High

Med-Low** Low

| 1950

1860

1300

1165

| 27| 1865

1780

1240

1115

| 29| 1790

1710

1200

1060

| 30| 1715

1635

1160

1025

| 31| 1630

1575

1120

985

| 33| 1550

1500

1065

940

| 34| 1475

1415

995

890

| 36

38

54

60

| 1390

1325

910

825

| 38

40

59

65

|
29| 30| 31| 33| 34| 36

50

57

|
41

46

| 43

48

| 44

50

| 46

52

| 48

54

|


SA072( )-35C

Side Return

| ****

72,000

| High* Med-High

Med-Low** Low

| 2030

1935

1350

1215

| 26

28

| 1940

1850

1290

1160

| 27

29

| 1860

1780

1250

1105

| 29

30

| 1785

1700

1205

1065

| 30

31

| 1695

1340

1165

1025

| 31| 1615

1560

1110

980

| 33

34

| 1535

1470

1035

925

| 35

36

52

58

| 1445

1380

945

860

| 37

39

56

62

|
40

46

52

|
40

44

| 41

46

| 43

48

| 44

50

| 48

54

|
Model Number| Heating Input (Btuh)| Motor Speed| External Static Pressure (Inches Water Column)|
---|---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8|
CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise|
SA072( )-35C

Side + Bottom or 2 Sides

| ****

72,000

| High* Med-High

Med-Low** Low

| 2050

1955

1365

1225

| 26

27

| 1960

1870

1300

1170

| 27

29

| 1880

1800

1260

1115

| 28

30

| 1800

1715

1220

1075

| 30

31

| 1710

1655

1175

1035

| 31

32

| 1630

1575

1120

985

| 33

34

| 1550

1485

1045

935

| 34| 1460

1390

955

865

| 37

38

56

62

|
36

51

57

|
39

44

| 41

46

| 42

48

| 44

50

| 45

52

| 48

54

|


SA090( )-35C

Bottom Return

| ****

90,000

| High*

Med-High** Med-Low Low

| 1940

1820

1290

1145

| 34| 1860

1760

1245

1110

| 36

38

54

60

| 1790

1695

1200

1070

| 37

39

56

62

| 1710

1620

1155

1035

| 39

41

58

64

| 1625

1545

1110

1000

| 41

43

60

| 1540

1466

1060

950

| 43

45

63

| 1450

1380

995

905

| 46

48

| 1355

1280

915

835

| 49

52

|
37

52

58

|
67| 73|
67| 70| 74| 80|


SA090( )-35C

Side Return

| ****

90,000

| High*

Med-High** Med-Low Low

| 2020

1895

1345

1190

| 33| 1935

1830

1295

1155

| 34| 1860

1765

1250

1115

| 36

38

53

60

| 1780

1685

1200

1075

| 37

40

56

62

| 1690

1610

1155

1040

| 39

41

58

64

| 1600

1525

1100

980

| 42

44

61

| 1510

1435

1035

940

| 44

46

64

| 1410

1330

950

870

| 47

50

|
35

50

56

| 36

51

58

|
70|
68| 71| 77|
SA090( )-35C

Side + Bottom or 2 Sides

| ****

90,000

| High*

Med-High** Med-Low

Low

| 2040

1910

1355

1205

| 33| 1955

1850

1310

1165

| 34| 1880

1780

1260

1125

| 35

37

53

59

| 1795

1700

1215

1085

| 37

39

55

61

| 1705

1625

1165

1050

| 39

41

57

63

| 1620

1540

1115

1000

| 41

43

60

| 1525

1450

1050

950

| 44

46

63

| 1425

1345

960

875

| 47

50

|
35

49

55

| 36

51

57

|
69|
67| 70| 76|


SA108( )-35C

Bottom Return

| ****

108,000

| High*

Med-High** Med-Low Low

| 2205

2050

1700

1390

| 36

39

47

58

| 2150

1995

1680

1370

| 37

40

48

58

| 2095

1955

1645

1355

| 38

41

49

59

| 2030

1895

1610

1320

| 39

42

50

61

| 1970

1840

1565

1300

| 41

43

51

62

| 1900

1775

1525

1270

| 42

45

52

63

| 1830

1700

1460

1225

| 44

47

55

65

| 1740

1610

1375

1175

| 46

50

58

|
68|


SA108( )-35C

Side Return

| ****

108,000

| High*

Med-High** Med-Low Low

| 2295

2130

1770

1445

| 35

38

45

55

| 2235

2075

1750

1425

| 36

39

46

56

| 2180

2035

1710

1410

| 37

39

47

57

| 2110

1970

1675

1375

| 38

41

48

58

| 2050

1915

1630

1350

| 39

42

49

59

| 1975

1845

1585

1320

| 41

43

50

61

| 1900

1765

1520

1275

| 42

45

53

63

| 1810

1675

1430

1225

| 44

48

56

65

|
SA108( )-35C

Side + Bottom or 2 Sides

| ****

108,000

| High*

Med-High** Med-Low

Low

| 2315

2155

1785

1460

| 35

37

45

55

| 2260

2095

1765

1440

| 35

38

45

56

| 2200

2055

1725

1425

| 36

39

46

56

| 2130

1990

1690

1385

| 38

40

47

58

| 2070

1930

1645

1365

| 39

41

49

59

| 1995

1865

1600

1335

| 40

43

50

60

| 1925

1785

1535

1285

| 42

45

52

62

| 1825

1690

1445

1235

| 44

47

55

65

|
SA126( )-45D

Bottom only or 2 openings

| ****

126,000

| High*

Med-High** Med-Low

Low

| 2255

2075

1720

1360

| 41

45

54

69

| 2200

2025

1695

1375

| 42

46

55

68

| 2125

1970

1655

1365

| 44

47

56

68

| 2065

1940

1630

1315

| 45

48

57

| 2010

1875

1580

1310

| 46

50

59

| 1935

1810

1520

1300

| 48

52

61

| 1855

1750

1455

1260

| 50

53

64

| 1755

1680

1390

1230

| 53

56

67

|
71| 71| 72| 74| 76|


SA126( )-45D

Side Return

| ****

126,000

| High*

Med-High** Med-Low Low

| 2230

2055

1705

1345

| 42

45

55

69

| 2180

2005

1680

1360

| 43

47

56

69

| 2105

1950

1640

1350

| 44

48

57

69

| 2045

1920

1615

1300

| 46

49

58

| 1990

1855

1565

1230

| 47

50

60

| 1915

1790

1505

1290

| 49

52

62

| 1835

1735

1440

1250

| 51

54

65

| 1740

1665

1375

1220

| 54

56

68

|
72| 76| 72| 75| 77|

  • ( ) Can be C or N
    • Factory Set Cooling Speed
  • ** Factory Set Heating Speed

NOTES:

  1. Two openings are recommended for airflows above 1600 CFM if filter(s) is(are) adjacent to the furnace.
  2. Temperature rises in the table are approximate. Actual temperature rises may vary.
  3. Temperature rises shaded in gray are for reference only. These conditions are not recommended.
KG7SK

Model Number| Heating Input (Btuh)| Motor Speed| External Static Pressure (Inches Water Column)
---|---|---|---
0.1| 0.2| 0.3| 0.4| 0.5| 0.6| 0.7| 0.8
CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise| CFM| Rise

SK054( )-23A

|

54,000

| High* Med-High

Med-Low** Low

| 1375

1155

790

650

| 29

35

51

| 1340

1130

775

640

| 30

35

52

| 1300

1110

765

630

| 31

36

52

| 1270

1085

750

610

| 31

37

53

| 1225

1055

730

590

| 33

38

55

| 1175

1015

700

565

| 34

39

| 1115

975

665

530

| 36

41

| 1035

910

610

480

| 39

44

57| 60| 66
62| 63| 63| 66| 68| 71| 75| 83

SK072( )-24B

|

72,000

| High* Med-High

Med-Low** Low

| 1610

1295

1155

910

| 33

41

46

59

| 1590

1275

1135

885

| 34

42

47

60

| 1575

1260

1115

860

| 34

42

48

| 1560

1250

1095

835

| 34

43

49

| 1540

1220

1065

810

| 35

44

50

| 1495

1195

1040

785

| 36

45

51

| 1460

1170

1015

765

| 37

46

53

| 1415

1120

980

735

| 38

48

54

62| 64| 66| 68| 70| 73

SK090( )-24B

|

90,000

| High* Med-High

Med-Low** Low

| 1675

1330

1180

940

| 40

50

56

| 1655

1315

1165

925

| 40

51

57

| 1640

1300

1150

900

| 41

51

58

| 1620

1280

1135

880

| 41

52

59

| 1590

1255

1115

850

| 42

53

60

| 1560

1230

1090

825

| 43

54

61

| 1520

1200

1060

795

| 44

56

63

| 1475

1150

1010

760

| 45

58

66

71| 72| 74| 76| 78| 81| 84| 88

SK108( )-35C

|

108,000

| High* Med-High

Med-Low** Low

| 2395

2190

1785

1145

| 33

37

45

| 2335

2135

1770

1110

| 34

37

45

| 2285

2115

1740

1070

| 35

38

46

| 2230

2080

1725

1035

| 36

38

46

| 2200

2030

1685

1000

| 36

39

47

| 2140

1975

1645

950

| 37

41

49

| 2080

1915

1615

905

| 38

42

50

| 2000

1810

1565

835

| 40

44

51

70| 72| 75| 77| 80| 84| 88| 96

SK126( )-45D

|

126,000

| High* Med-High

Med-Low** Low

| 2445

2195

1795

1480

| 38

43

52

63

| 2395

2170

1780

1475

| 39

43

52

63

| 2385

2140

1770

1450

| 39

44

53

64

| 2330

2120

1760

1440

| 40

44

53

65

| 2275

2090

1725

1440

| 41

45

54

65

| 2225

2030

1690

1415

| 42

46

55

| 2130

1975

1655

1405

| 44

47

56

| 2015

1855

1610

1375

| 46

50

58

66| 66| 68

  • ( ) Can be C or N
    • Factory Set Cooling Speed
  • ** Factory Set Heating Speed

NOTES:

  1. Temperature rises in the table are approximate. Actual temperature rises may vary.
  2. Temperature rises shaded in gray are for reference only. These conditions are not recommended.

MODEL IDENTIFICATION CODE

Gibson-KG7S-Gas-Furnace-fig- \(5\)

SPECIFICATIONS

KG7SA MODEL NUMBERS| -045-23A| -054-23A| -072-24B| -090-24B| -072-35C| -090-35C| -108-35C| -126-45D
---|---|---|---|---|---|---|---|---
Input – Btuh (a)| 45,000| 54,000| 72,000| 90,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 36,000| 43,200| 57,600| 72,000| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 10 x 6| 11 x 8| 11 x 8| 10 x 10| 10 x 10| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 1.0 – 4 – PSC| 1.0 – 4 – PSC
Motor FLA| 4.80| 4.80| 8.20| 8.20| 7.50| 7.50| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 30-60| 35-65| 35-65| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 100lbs| 110lbs| 115lbs| 115lbs| 120lbs| 125lbs| 145lbs
KG7SK MODEL NUMBERS| -054-23A| -072-24B| -090-24B| -108-35C| -126-45D
---|---|---|---|---|---
Input – Btuh (a)| 54,000| 72,000| 90,000| 108,000| 126,000
Heating Capacity – Btuh| 43,200| 57,600| 72,000| 86,400| 100,800
AFUE| 80.0| 80.0| 80.0| 80.0| 80.0
Blower D x W| 10 x 6| 11 x 8| 11 x 8| 11 x 10| 11 x 10
Motor H.P. – Speed – Type| 1/3 – 4 – PSC| 1/2 – 4 – PSC| 1/2 – 4 – PSC| 3/4 – 4 – PSC| 1.0 – 4 -PSC
Motor FLA| 4.80| 8.20| 8.20| 13.75| 13.75
Rated Ext. SP – In. W.C.| 0.5| 0.5| 0.5| 0.5| 0.5
Temperature Rise Range – ºF| 30-60| 35-65| 35-65| 40-70| 40-70
Shipping Weights| 100lbs| 110lbs| 115lbs| 125lbs| 145lbs

ACCESSORIES

KG7S (A, K) KITS

Description| SKU
“A” Cabinet fixed speed, high efficiency, FSHE| 904872
“B” Cabinet fixed speed, high efficiency, FSHE| 904873
“C” Cabinet fixed speed, high efficiency, FSHE| 904874
“D” Cabinet fixed speed, high efficiency, FSHE| 904875
“A” Cabinet variable speed, high efficiency, VSHE| 904876
“B” Cabinet variable speed, high efficiency, VSHE| 904877
“C” Cabinet variable speed, high efficiency, VSHE| 904878
“D” Cabinet variable speed, high efficiency, VSHE| 904879
“A” Cabinet downflow sub base kit| 902974
“B”, “C”, “D” Cabinet downflow sub base kit| 904911
U.S. LP Conversion kit (0 to 10,000 ft.)| 904914
Canada LP Conversion kit (0 to 4,500 ft.)| 904915
Bottom return filter 20 per box, “A” cabinet| 903088
Bottom return filter 20 per box, “B” cabinet| 904916
Bottom return filter 20 per box, “C” cabinet| 904917
Bottom return filter 20 per box, “D” cabinet| 904918
Side return filter kit| 541036

Gibson-KG7S-Gas-Furnace-fig- \(6\)

GENERAL TERMS OF LIMITED WARRANTY

  • NORDYNE will furnish a replacement for any part of this product that fails in normal use and service within the first ten years of installation, per the terms of the warranty.
  • For complete details of the Limited Warranty, including applicable terms and conditions, see your local installer or contact the NORDYNE warranty department for a copy.

8000 Phoenix Parkway | O’Fallon, MO 63368-3827 Specifications and illustrations are subject to change without notice and without incurring obligations. Printed in U.S.A (02/2011) 739C-0211 (Replaces 739C-0608).

GIBSON is a pending or registered trademark of Electrolux Home Products Inc. and used under a license from Electrolux Home Products, Inc. © Nortek Global HVAC, LLC. All Rights Reserved. www.gibsonhvac.com.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Gibson User Manuals

Related Manuals