APC APDU9959EU3 Power Distribution Unit (PDU) Specifications and Datasheet

June 15, 2024
APC

APC APDU9959EU3 Power Distribution Unit (PDU)

Product datasheet Specifications

  • APC Rack PDU 9000 Switched, ZeroU, 16A, 230V, (21) C13 & (3) C19, IEC309 Cord
  • APDU9959EU3

Modern data centres and IT environments require a cutting-edge solution for power distribution, and that answer is the APC APDU9959EU3 Power Distribution Unit (PDU). This PDU is a dependable and effective part of managing power resources because of its sophisticated features and specs.

Overview

  • Lead Time: Usually in Stock

For rack-mounted installations, the zero-U designed Switched PDU APDU9959EU3 offers a space-saving option. With 21 IEC 60320 C13 outlets and 3 IEC 60320 C19 outlets, it provides a flexible power distribution system that operates at 16A and 230V. A 3.00-meter IEC 60309 16A 2P + E input power cord is included with the machine, allowing for flexible placement.

Features

  • Technology for switched PDUs: The APC APDU9959EU3 is a switched PDU with advanced features for controlling and tracking power from afar. This lets users control individual outlets and make sure that power is distributed as quickly as possible.

  • The zero-U design: The PDU has a zero-U form factor, which means it doesn’t take up any rack room. This makes the best use of space in rack-mounted configurations.

  • Voltage at Input and Output: The main incoming voltage is 230V, and the output voltage is always 230V. This makes sure that the power is distributed reliably.
    Large Amount of Power: The PDU can handle a load of 3700 VA and a maximum line current of 16A. This means it can power a wide range of devices in a data centre.

  • Flexible Configuration of Outlets: The PDU has 21 IEC 60320 C13 outlets for normal devices and 3 IEC 60320 C19 outlets for high-power equipment, so it can be used with a range of power needs.

  • Protocols for communication: It has SNMP (Simple Network Management Protocol) and Redfish communication ports, which make it easy to connect to network management tools and monitor and control in real-time.

  • Smart options for mounting: The PDU can be mounted in several different ways because it is designed to be mounted vertically. Because it is mounted on the side, it is easy to add to rack setups.

  • Strong Construction and Small Size: Even though it’s built to last, the PDU is still very small, measuring 179.4 cm tall, 5.5 cm wide, and 4.6 cm deep. It only weighs 5.61 kg, so it’s a light but strong option.

  • Features for safety: The locking input power cords on the PDU make sure that connections are safe, which adds to the total safety. It also comes with a safety guide to help people use it correctly.

  • Compatible with Networks: It works with a 10/100/1000BASE-T communication network type and offers fast connections for effective power distribution monitoring and control.

  • Use in other countries: The PDU’s input link type is IEC 60309 16A 2P + E, which means it can be used anywhere in the world with voltages between 220V and 240V.

  • Certifications and following the rules: It has licenses like FCC part 15 class A, VDE, and RCM, and it follows rules like EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, and ICES-003. It follows the rules set by RoHS and Reach.

  • Service warranty and durability: You can get it fixed or replaced under the guarantee for 3 years. Adopts Schneider Electric’s Green PremiumTM pledge, which guarantees the best environmental performance and adherence to rules.

Main
  • Main Input Voltage: 230 V
  • PDU Type: Switched
  • Main Output Voltage: 230 V
  • Input Connection Type: IEC 60309 16 A 2P + E, IEC 60320 C20
  • Number Of Rack Unit: 0U
  • Cable Length: 3.00 m
  • Number Of Cables: 1
  • Communication Port Protocol: SNMP, Redfish
  • Provided Equipment: Installation guide, Locking input power cord, Rack mounting brackets, Safety guide
Batteries & Runtime
  • Communication Network Type: 10/100/1000BASE-T
Physical
  • Colour: Black
  • Height: 179.4 cm
  • Width: 5.5 cm
  • Depth : 4.6 cm
  • Net Weight: 5.61 kg
  • Mounting Location: Side
  • Mounting Preference: No preference
  • Mounting Mode: Not rack-mountable
  • USB Compatible: No
  • Mounting Position: Vertical
Input
  • Permissible Voltage : 220…240 V
  • Max Line Current: 16 A
  • Input Current Limits : 16 A
  • Load Capacity: 3700 VA
  • Network Frequency: 50/60 Hz
Output
  • Number Of Power Socket Outlets: 21 IEC 60320 C13, 3 IEC 60320 C19

Conformance

  • Product Certifications: FCC part 15 class A, VDE, RCM, EAC
  • Standards: EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, ICES-003

Environmental

  • Ambient Air Temperature For Operation : -5…60 °C
  • Relative Humidity: 5…95%
  • Operating Altitude: 0…10000 ft
  • Ambient Air Temperature For Storage: -25…65 °C
  • Storage Relative Humidity: 5…95%
  • Storage Altitude: 0.00…15240.00 m

Packing Units

  • Unit Type Of Package: 1 PCE
  • Number Of Units In Package 1: 1
  • Package 1 Height: 200.2 cm
  • Package 1 Width: 11.4 cm
  • Package 1 Length: 16.5 cm
  • Package 1 Weight: 8.59 kg

Contractual Warranty

  • Warranty: 3 years repair or replace

Sustainability

Green PremiumTM label is Schneider Electric’s commitment to delivering products with best-in-class environmental performance. Green Premium promises compliance with the latest regulations,  transparency on environmental impacts, as well as circular and low-CO2 products.

Learn more about Green Premium 

  • Transparency
  • RoHS/Reach

Well-being performance

  • Mercury Free
  • Rohs Exemption Information:Yes

Certifications & Standards

Frequently Asked Questions

What is the APC APDU9959EU3 PDU designed for?

The APC APDU9959EU3 is a Power Distribution Unit (PDU) designed for efficiently distributing power in data center and IT environments.

What is the main input voltage and output voltage of the APC APDU9959EU3 PDU?

The main input and output voltage for the APC APDU9959EU3 PDU is 230V.

How many outlets does the PDU have, and what types are they?

The PDU features 21 IEC 60320 C13 outlets for standard devices and 3 IEC 60320 C19 outlets for high-power equipment.

What is the cable length and type of input connection for the APC APDU9959EU3 PDU?

The PDU comes with a 3.00-meter IEC 60309 16A 2P + E input power cord.

Can the APC APDU9959EU3 PDU be mounted in a rack?

Yes, the PDU is designed to be rack-mounted. It has a zero-U design, making it a space-efficient solution.

Does the APC APDU9959EU3 PDU have any communication ports?

Yes, the PDU is equipped with communication ports supporting SNMP (Simple Network Management Protocol) and Redfish protocols.

What are the physical dimensions and weight of the APC APDU9959EU3 PDU?

The PDU has a height of 179.4 cm, a width of 5.5 cm, a depth of 4.6 cm, and weighs 5.61 kg.

Is the APC PDU USB compatible?

No, the APC APDU9959EU3 PDU is not USB compatible.

What is the warranty period for the APC APDU9959EU3 PDU?

The PDU comes with a 3-year contractual warranty, offering repair or replacement.

Can the APC APDU9959EU3 PDU be used in environments with varying temperatures?

Yes, the PDU is designed to operate in ambient air temperatures ranging from -5 to 60 °C during operation and -25 to 65 °C during storage.

How does the APC APDU9959EU3 PDU contribute to sustainability?

The PDU is part of Schneider Electric’s Green PremiumTM program, signifying a commitment to environmental performance, compliance with regulations, and the production of circular and low-CO2 products.

What certifications does the APC APDU9959EU3 PDU have?

The PDU holds certifications including FCC part 15 class A, VDE, RCM, and conforms to standards such as EN 55022 class A, EN 55024, EN 61000-3-2, EN 61000-3-3, and ICES-003.

Can the APC APDU9959EU3 PDU be used at varying altitudes?

Yes, the PDU is operational at altitudes ranging from 0 to 10,000 feet.

Is the APC APDU9959EU3 PDU mercury-free and compliant with RoHS/Reach regulations?

Yes, the PDU is designed with RoHS/Reach compliance and is mercury-free.

How can I dispose of the APC APDU9959EU3 PDU at the end of its life?

The product must be disposed of on European Union markets following specific waste collection guidelines and should not end up in regular rubbish bins. Refer to local regulations for proper disposal methods.

Reference:APC APDU9959EU3 Power Distribution Unit (PDU) Specifications and Datasheet- device.report

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals