Single lever basin and bidet mixer
B11010 Basin Tap Chrom
B.1
B11010 0010 10
B11010 0020 10
B11020 0010 10
B11020 0020 10
B11010 0030 10
B11020 0030 10
B12400 0010 10| B.2
B21010 0010 10
B21010 0020 10
B21020 0010 10
B21020 0020 10
B21010 0030 10
B21020 0030 10
B22400 0010 10| B.3
B31010 0010 10
B31010 0020 10
B31020 0010 10
B31020 0020 10
B31030 0010 10
B31030 0020 10
B32400 0010 10
---|---|---
Important information
These instructions are part of the Duravit product and must be read carefully
and kept available at all times.
Target readership and qualifications
The product may only be installed by a qualified plumber.
Explanation of the key words and symbols
NOTICE
Addresses practices not related to physical injury.
| Link to the mounting instructions in this section
---|---
| Prompt for inspection (e.g. for scratches)
| Prompt to inspect for leaks and leak-tightness
| Prompt to wear gloves
| Optional settings
Technical data
Operating pressure | max. 0.5 MPa |
---|---|
Recommended | 0.3 MPa |
Test pressure
1 MPa = 10 bar = 145 PSI| 0.5 MPa
Hot water temperature| max. 60 °C
Safety instructions
Cut and crushing injuries
Wear gloves when installing the product.
Product and/or property damage
Observe the local installation regulations and any country-specific standards at all times.
Equalise pressure differences between cold and hot water connections.
Observe the manufacturer’s instructions for installation with continuous flow heaters.
Mounting instructions
1. Flushing and siliconising (diagram 01)
NOTICE
Tap unit malfunction due to dirty pipes
Flush the pipes according to the applicable standards before mounting the tap unit.
Water damage
Enclose pipes with silicone that does not contain acetic acid.
Installation
Operation
Care & maintenance
DURAVIT AG
P.O. Box 240
Werderstr. 36
78132 Hornberg
Germany
Phone +4
9 78 33 70 0
Fax +4
9 78 33 70 289
info@duravit.com
www.duravit.com
MAL_57252/19.04.6
Order no. 57252/19.04.6 We reserve the right to make technical improvements